RH-6340_rev A_NWP-1-532.qxd

RH-6340_rev A_NWP-1-532.qxd
INSTALLATION INSTRUCTIONS
Shown with RH-212
Sold Separately
MODEL: Dillon
RH-6340
1
REV.A
Restoration Hardware
Balance Pressure Shower Set
Specification Diagram
Shown with RH-212
Sold Separately
BOTTOM OF SHOWER
All Threaded Connections are 1/2” NPT
Dimensions are in Inches and Approximation of a Typical Installation
2
Technical support: 1-866-417-5207
Customer Service: 1-877-747-4671
RH-6340 REV A
Common tools needed:
Plumbers
Putty
Pipe
Wrench
Adjustable
Wrench
Pipe
Cutter
Assorted
Screwdrivers
Thread
Sealant
Perforated
Strap and
Clamp
Installation Instructions
We Recommend Installation by a Licensed Plumbing Professional
1. Valve Assembly
•
•
•
Position VALVE (1) with the “S” in the up position
The VALVES (1) 1/2” NPT inlets are colored blue for COLD SUPPLY (2) and red for HOT SUPPLY (3).
7
Apply thread sealant to the supply fittings and firmly tighten into
VALVE (1) inlets. Under normal soldering conditions the removal
of inlet filter/seat and mixing cartridge is not necessary; however, if
brazing and / or induction heating is used removal is required.
Whenever possible, it is best to perform all solder/brazing operations on piping prior to attachment to VALVE (1).
•
•
•
•
•
•
VALVE (1) and / or SUPPLY (2,3) must be secured to CROSS
BRACE (4) using PERFORATED STRAP (5) or equivalent.
Position VALVE (1) to finished wall as mentioned on specification
diagram.
5
6
4
3
Apply thread sealant to SHOWER RISER (6) and attach to VALVE
(1) outlet port marked “S”.
1
Secure SHOWER RISER (6) to CROSS MEMBER (4) using PERFORATED STRAP (5) or equivalent.
Apply PLUG (7) for test. Turn on both water supplies to valve and
check for leaks. Note: Water pressure must be applied to both hot
and cold inlet ports for proper valve operation.
After inspection turn off water supply.
2
3
Technical support: 1-866-417-5207
Customer Service: 1-877-747-4671
RH-6340 REV A
2. Setting The Temperature Limit Stop
•
•
Remove the all-thread NIPPLE (1) and RETAINING SCREWS (2) RETAINING PLATE (4) and STEM
(5) from the valve COVER (9).
Remove the LIMIT STOP (6) see figure 2. Do not remove the MECHANICAL STOP (7). (If for any
reason the MECHANICAL STOP (7) is removed refer to Cartridge Removal and Replace section
below.)
•
•
From the CLOSED position, rotate the CARTRIDGE STEM (10) counter-clockwise until the desired
temperature is achieved.
Place the LIMIT STOP (6) on the CARTRIDGE STEM (10) against the STOP BLOCK (15) located on
COVER (9). Rotate the CARTRIDGE STEM (10) several times to make sure the stop is at the desired
temperature setting.
•
Replace the STEM (5), RETAINING PLATE (4) and RETAINING SCREWS (3) and all-thread NIPPLE
(1) onto valve COVER (9). (NOTE: For stem to be fully seated into cartridge, all-thread nipple and locking nut must be tightly secured against retaining plate.)
•
Proceed to the VALVE TRIM INSTALLATION.
13
9
10
8
7
6
11
2
12
15
5
4
1
4
Technical support: 1-866-417-5207
Customer Service: 1-877-747-4671
RH-6340 REV A
2a. Cartridge Removal And Replacement
•
•
•
•
•
Remove the all-thread NIPPLE (1), RETAINING SCREWS (2), RETAINING PLATE (4) and STEM (5)
from the valve COVER (9).
Remove the LIMIT STOP (6) and MECHANICAL STOP (7)
Remove the COVER SCREWS (8), COVER (9) and cover O-RING (10).
Carefully slide the CARTRIDGE (10) out of valve BODY (13). (If filter removal is necessary refer to
Cleaning the Filter described in Trouble Shooting Section.)
Replace CARTRIDGE (10) ensuring that the cartridge’s O-RINGS (11) are in place and lubricated with
plumbers (non-petroleum) grease. The “H” and “C” on the side of the CARTRIDGE (10) indicates the cartridges proper orientation to the appropiate inlet supply line.
•
•
•
•
•
5
Once the CARTRIDGE (10) is installed, it is very important to confirm that the cartridges rear posts are
correctly locked into the BODY (13) mating hole.
Replace the cover O-RING (12), COVER (9) and tighten COVER SCREWS (8) firmly into place.
To set the MECHANICAL STOP (7) rotate clockwise the CARTRIDGE STEM (10) until it stops.
Warning: Do not forcefully rotate stem closed.
Place the MECHANICAL STOP (7) onto CARTRIDGE STEM (10) as shown in figure 1.
Replace LIMIT STOP (6) as described above in Setting the Temperature Limit Stop.
Technical support: 1-866-417-5207
Customer Service: 1-877-747-4671
RH-6340 REV A
3. Valve Trim Installation
(Perform these steps after finished wall has been completed)
•
•
•
•
•
The STEM (3) must be trimmed to 1-7/8” from finished wall. Remove STEM (3) by loosening NUT (2)
and removing NIPPLE (1), NUT (2) and STEM (3). Trim STEM (3) to previously mentioned dimension.
The NIPPLE (1) must be trimmed 3/4” less than STEM (3).
Fasten STEM (3) and NIPPLE (1) onto VALVE (4). Use NUT (2) to lock NIPPLE (1) into place. Rotate
STEM (3) to ensure there is no binding. If binding, loosen NIPPLE (1) until STEM (3) moves freely and
does not wobble.
Align cover PLATE (5) and slide onto valve NIPPLE (1). Install BUSHING (8).
Insert WASHER (9), then O-RING (10) into the backside of ESCUTCHEON (8) and place over NIPPLE
(1) and flush against cover PLATE (5). Thread BUSHING (6) onto NIPPLE (1). Secure HANDLE (7) by
first engaging the STEM (3) and then threading onto BUSHING (8). Any adjustments for rotational alignment must be made by tightening cartridge. DO NOT loosen cartridge. Factory torque of 14 ft.lbs. must be
maintained.
4
2
1
10
3
9
6
7
5
8
6
Technical support: 1-866-417-5207
Customer Service: 1-877-747-4671
RH-6340 REV A
4. Showerhead Installation
(RH-212 not included)
(Balanced pressure shower with Speakman Ultra Showerhead kit.)
•
•
•
•
•
•
Slide SHOWER ARM (2) through the FLANGE (3).
2
Apply thread sealant to both ends of ARM (2) and
thread into fitting inside finished wall.
1
Turn on water supply, check for leaks and make any
final adjustments required.
Open valve and flush shower line of debris.
Slide FLANGE (3) against wall.
3
Attach SHOWERHEAD (1) to end of ARM (2).
5. Test Installed Shower Set
•
•
Turn on the shower valve by rotating the handle counter-clockwise.
Water mixing temperature to handle rotation is as follows:
•
7
0 to 1/4 = cold
•
1/4 to 1/2 = warm
Technical support: 1-866-417-5207
•
1/4 to 1/2 = warm
1/2 to 3/4 = hot
1/2 to 3/4 = hot
Customer Service: 1-877-747-4671
RH-6340 REV A
6. Trouble Shooting
* WARNING: At no time try to stop dripping by applying extreme force or overtightening the handle.
8
Technical support: 1-866-417-5207
Customer Service: 1-877-747-4671
RH-6340 REV A
Care and Cleaning
The lustrous finish on your Restoration Hardware Bathware fixture should
be treated with care. Improper handling or cleaning can damage the surface
of any metal finish. Use a soft cloth to wipe clean. Avoid harsh abrasive
cleaner. Water contains lime and other mineral deposits that will be left on
the surface after the water has evaporated. You can prevent these deposits
from forming by always wiping the fixture dry immediately after use.
Technical Support and Customer Service
For technical support in the installation of your Restoration Hardware
Bathware fixture, please call 1-866-417-5207 weekdays between the hours
of 7:00am and 4:00pm PST.
For other questions regarding your order, to order additional components of
the Restoration Hardware Bathware Collection, to order replacement parts,
or to address warranty issues, please contact Restoration Hardware
Customer Service at 1-877-747-4671.
9
EN-1711
RH-6340 REV A
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising