Telescopic Automatic

Telescopic Automatic
H275AE / H275AEL
MAINTANANCE ADVICE
Heat damages batteries. Avoid placing them near a heat source. The maximum
performance is achieved at an operating temperature of 20∫C.
Bollard
Telescopic
Automatic
Flammable gas may be generated by the batteries. Please do not install them in
spark-risk areas.
When installed in closed areas, please provide adequate ventilation.
Batteries are made in high-impact ABS plastic resin.
The contact with an organic solvent atmosphere or adhesive material may damage
them.
INSTALLATION AND OPERATING
INSTRUCTIONS
Items supplied
1 Bollard
Connect terminals in correct sense, avoid direct welding. Use a welder with a
maximum power of 1000W for 3 seconds.
1 control box
Allowed operating temperature range: -15∫C to 50∫C.
1 Remote
controller
Recommended operating temperature range: 5∫C to 35∫C.
Use impact absorbing material in case of installing batteries in vibration and impact
risk areas.
Clean the batteries with a damp cloth. Never use oil, solvents or fuel.
Never attempt to dismantle the battery, since it contains sulphuric acid, a highly
corrosive product. . In case of contact with the acid, rinse immediately with plenty of
clean, flowing water and seek immediate medical attention.
2 magnetic loops
Do not dispose the batteries in a fire.
To avoid damages to the equipment, please do not mix old and new batteries nor
batteries with different characteristics.
Date : 10 / 2010. V02
Maintain the terminals isolated to avoid electrical shocks.
1 Connection
cable ( 15 m ),
from box to
bollard
1 Anti-theft ALLEN key
Failure to meet any of the (installation) requirements releases the manufacturer from any
responsibility for the operation of the bollard and voids the guarantee.
Optional with LED blue
Parts of the bollard
Cast metal base plate
Remote controller
Manhole
cover
Piston
visible element of the bollard when up.
Made in polished stainless steel.
Manoeuvre connection box
all the electronic elements for the bollards
control are fitted inside of it. See point 3.
Stainless steel core
(main element of the bollard. Made in stainless steel and complies
with IP67. Inside, a linear actuator can be found, which is
responsible for the vertical movement of the bollard. The core is
fixed to the built-in box at the lower part).
Built-in box
Connection cable (15 m)
Made in stainless steel supplied with legs to make clamping to
concrete easier. Solid and high-resistance piece.
It is supplied with a 15m hose with an end
ready to be connected to the bollard.
A 75mm diameter drain pipe comes
out of the bottom and into the drains.
-1-
1
6
Installation
Operation of the Bollard
650
A
1. Normal mode:
1100
The bollard is operated using the remote control, both for lowering and raising it. The vehicle need not
be on the magnetic loop situated in front of the bollard.
250
B
The vehicle must be positioned over the magnetic loop situated in front of the bollard. Once it is in
place, pressing the remote control lowers the bollard. When the vehicle has passed over the bollard and
the other magnetic loop the bollard comes back up automatically, with no need to press the control.
(If a vehicle is going in the wrong direction the bollard does not work).
A. Make a square hole into the ground measuring
650x650mm and a depth of 1100mm.
The bollard is delivered in a closed set.
B. Install a 90mm drain tube in the base of the hole.
If it is not possible, a drain layer must be provided.
2
2. Automatic raising mode in one traffic direction:
Ø90
3. Automatic raising mode in two traffic directions:
The vehicle must be positioned over the magnetic loop situated in front of the bollard. Once it is in
place, pressing the remote control lowers the bollard. When the vehicle has passed over the bollard and
the other magnetic loop the bollard comes back up automatically, with no need to press the control.
(Works with vehicles going in both directions).
Once the concrete is set connect the bollard to the control box.
Note: In the absence of any information from the customer, bollards are configured in normal
mode, and the customer can change this configuration whenever they wish.
Control box connection,
(see point 3).
H
I
K
J
Timer control mode:
L
This activates the timer in order to restrict or allow traffic within specific time slots.
ELECTRIC CONNECTION
H. Remove the square cast iron cover by
unfastening the 4 Allen locking bolts.
Optional connections:
M
- Traffic lights (red and green).
- Fitting for opening or closing the bollard using an external control (button, entry control, interphone,
etc.).
- LED connection to the bollard (bollards fitted with LED only).
K. Coil the supplied cable connector ejected
from the staple (align the centring slot of the
male connector to the female connector).
-2-
-7-
Remote controllers configuration.
850
In case extra remote controllers are supplied, they will have to be configured with the bollard. Its
configuration will be made in the bollardís control box. Steps:
2
Unscrew the antenna cable.
Remove the cover by
sliding it upwards.
I
250
E
G
ELECTRICAL CONNECTION
ELECTRICAL CONNECTION
10/20
Ø150
H
D
250
1
Ø63
F
IMPORTANT
5
C
C. Make a drainage for water evacuation.
F. Place the closed bollard in the hole on top of the base.
D. Make a concrete base to ensure the ground is even and the
bollard can be placed on top. Leave the central part of the base free
to evacuate rainwater (through drainage).
G. Connect the corrugated tube to the side hole of the built-in
box, so that no concrete can penetrate into the box. The corrugated
tube should be inserted max. 1 or 2 cm. to avoid any contact with
the mobile part of the bollard.
E. The corrugated tube from the control box to the bollard must be
placed 250mm from the ground.
H. Fill the base with draining rocks.
I. Fill the hole with concrete (avoid the concrete being too liquid so that
3
the drain hole is not obstructed).
Press the red button for 2 seconds until a ìbeepî is heard.
J. To unlock the connector (fixed by a staple),
pull up. It will eject easily.
I. Remove the manhole cover, loosen the 4 Allen
screws to reach the corrugated tube (connection
cable from the bollard to the control box).
On the remote control being set up, press the top button until
a bleep sounds to save the code of the bollard. After a few
seconds 2 bleeps in succession will be heard, and the remote
control can then be used with no problem.
“c l i c k ”
These programming instructions are also shown on each remote
control box.
M. Secure the cable to the bracket located on the
side perpendicular to the housing bracket to avoid
the friction of the cable.
L. Once coiled, put the cable back onto the staple
by slightly pressing down until you hear a click.
-6-
-3-
3
Connections in the control box
Connections of the control box:
The control box will be installed on the wall.
If it is installed outdoors, we recommend you
to install it inside a vandal proof box.
Accessories for wall fixing.
BOLLARD GENERAL
SWITCH
Detail of fixing accessories
assembling.
OPERATION OF THE BOLLARD
normal mode:
(jumper between common and normal)
1-way automatic mode:
(jumper between common and 1-way)
2-way automatic mode:
(jumper between common and 2-way)
timed operation:
(jumper between timer and timer)
BOLLARD OPERATION SELECTOR
position for normal operation: SELECTOR UP
stop position: SELECTOR CENTRED
manual lowering position: SELECTOR DOWN
Set-up:
Optional traffic light
LED hose connection
(bollards with LED only)
Optional outside
control (button,
interphone, entry
control)
Motor hose
connection
Magnetic loop no. 1 connection
Magnetic loop no. 2 connection
230V single-phase
power supply.
After making all the connections, turn the switches in the electrical box on, first the GENERAL and then the one for the BOLLARD.
While the bollard switch is off it cannot be either raised or lowered.
When the box is connected to the power, the bollard resets itself automatically. If it does not do so, contact the manufacturer.
Raise and lower the bollard several times to make sure the mechanism works properly.
4
Installing the magnetic lasso
Make holes (A) in the form of two 2 x 2-metre
rectangles to house the magnetic safety strips,
2000
2000
DIRECTION OF TRAVEL
separated from one another by a distance of
BOLLARD
1500mm, in the centre of which the bollard is
quick-setting compound, mortar or epoxy resins.
SAFETY LOOP
SAFETY LOOP
The magnetic loops must be connected to the
electrical box at the terminals shown.
750
magnetic loop cable
750
(A)
Note:
Under no circumstances must the loop cable be
mixed up with live cables, either for the bollard
itself or for other installations in the same area.
concrete
-4-
-5-
2000
2000
installed. The hole should be covered with
Was this manual useful for you? yes no