differential probe p9000
DIFFERENTIAL PROBE P9000
LR8410
For Hioki Memory HiCorders
and HiLoggers
MR8875
MR8870
Delivering Greater Flexibility to
Waveform Recording
Easily Connect to Hioki Memory HiCorders and HiLoggers for High
Voltage Testing
•
•
•
•
1/2 the size and weight of legacy differential probe Model 9322
1000V AC/DC (CAT III 1000V / CAT IV 600V) 1000:1, 100:1
Wide operating temperature range of -40°C to 80°C
3-way power supply (AC adapter, USB, external DC power supply)
New 1/2 the size of legacy model
product Easily use with 3-way power supply
Legacy
product
•The AC adapter was too large…
•The setup was a bit much just to measure
200 V AC…
• CATIII 1000V measurement with a compact probe
• Use WAVE mode to observe instantaneous waveforms
• Use AC-RMS mode to observe RMS waveforms
• Principal applications…
1. High-voltage battery circuits in vehicles such as
EVs and HEVs
2. High-voltage circuits in solar power installations
and other alternative energy systems
3. Commercial power circuits, for example 480
Vrms circuits
4. High-voltage surge noise from inver ters,
motors, and solenoids, etc.
■ Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
P9000-01
P9000-02
Waveform monitor output only Waveform monitor output/AC RMS value output (switchable)
Wave mode frequency characteristics: DC to 100 kHz, -3 dB
Measurement
Frequency characteristics: DC RMS mode frequency characteristics: 30 Hz to 10 kHz; response
functions
to 100 kHz, -3 dB
time: 300 ms (rising) or 500 ms (falling)
Model : DIFFERENTIAL PROBE P9000
Division ratio
Model No. (Order Code) (Note)
P9000-01
P9000-02
1000:1 or 100:1 (user selectable)
DC amplitude accuracy ±0.5% f.s. (f.s. = 1.0 V; voltage division ratio: 1000:1) (f.s. = 3.5 V; voltage division ratio: 100:1)
(For the Memory HiCorder series, Wave only)
(For the Memory HiCorder series, Wave/RMS)
Connect to a Memory HiCorder’s analog input terminal. Must be powered by an AC
adapter, USB bus power, or other suitable power source.
■ WAVE mode: Record actual waveforms using DC coupling, AC-RMS mode: RMS value of the
output AC waveform
■ A Female BNC/Wire Conversion Cable (special-order) option is available for connecting the
probe to a data logger’s terminal block. Power can also be supplied from a Memory HiCorder’s
logic terminal.
■ Use a commercially available USB cable to power the probe from a USB bus [USB (A type male)
to USB (Micro B type male)]
■ Hioki can also provide a three-branch cable that splits power from an AC adapter or USB cable
on a special-order basis. Please contact your Hioki distributor for more information.
RMS amplitude accuracy ±1% f.s. (30 Hz to 1 kHz non-inclusive, sine wave), ±3% f.s. (1 kHz to 10 kHz, sine wave)
Input resistance, capacity Between H and L: 10.5 MΩ, 5 pF or less (at 100 kHz)
Max. allowable input 1000 V AC/DC
Max. rated voltage to earth 1000 V AC/DC (CAT III)
Operating temperature -40 ˚C (-40 ˚F) to 80 ˚C (176˚F)
(1) AC Adapter Z1008 (100 to 240 V AC, 50/60 Hz), 6 VA (including AC adapter) or
0.9 VA (probe only)
Power supply
(2) USB bus power (5 V DC, USB Micro-B receptacle), 0.8 VA
(3) External power supply (2.7 V to 15 V DC)
Dimensions and mass 128 mm (5.04 in)W × 36 mm (1.42 in)H × 22 mm (0.87 in)D, 170 g (6.0 oz)
Input: 70 cm (2.30 ft) ; output: 1.5 m (4.92 ft)
Cord length
Instruction manual ×1, alligator clips ×2, carrying case ×1
Accessories
Options
Test Pin Set L4932 is required when using the Small Alligator Clip Set L4934.
100 to 240 V AC
Input cables
Power supplies
AC ADAPTER Z1008
EXTENSION CABLE TEST PIN SET
SET L4931
L4932
Expands the length of the Attaches to the tip of the
cable with banana plug,
banana plug cable, CAT
1.5 m (4.92 ft) length
IV 600V, CAT III 1000V
L1011-10
2.4 m (7.87 ft) length, covert BNC to
wire
Special order cables
Output cables
CONVERSION CABLE L1011
30 cm (0.98 ft) length, covert BNC
to wire
CONVERSION CABLE
SMALL ALLIGATOR
ALLIGATOR CLIP SET BUS BAR CLIP
CLIP SET L4934
L4935
SET L4936
Attaches to the tip of
MAGNETIC ADAPTER TEST PIN SET
SET L4937
L4938
Attaches to the tip of the Attaches to the tip
Attaches to the tip of the Attaches to the tip
the L4932, L9207-10/
banana plug cable, CAT of the banana plug
DT4911, L9206, CAT III banana plug cable, CAT of the banana plug
IV
600V,
CAT
III
1000V
cable,
CAT
III
600V
III 1000V
cable, CAT III 600V
300V, CAT II 600V
BREAKER PIN
SET L4939
Attaches to the tip
of the banana plug
cable, CAT III 600V
GRABBER CLIP 9243
Attaches to the tip of the
banana plug cable, CAT III
1000 V, 196 mm (7.72 in)
length
Please contact your local HIOKI distributor
USB Bus Power Cable
Supplies power from a USB
Standard Type A receptacle
USB A/Micro-B Cable
Three-branch Cable
Supplies power from a USB Standard Type Splits AC adapter output into
A receptacle via a USB Micro-B plug
three separate plugs
Note: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.
HIOKI (Shanghai) SALES & TRADING CO., LTD.
TEL +86-21-63910090 FAX +86-21-63910360
http://www.hioki.cn / E-mail: [email protected]
DISTRIBUTED BY
HIOKI SINGAPORE PTE. LTD.
TEL +65-6634-7677 FAX +65-6634-7477
HEADQUARTERS
E-mail: [email protected]
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 FAX +81-268-28-0568
HIOKI KOREA CO., LTD.
http://www.hioki.com / E-mail: [email protected] TEL +82-2-2183-8847 FAX +82-2-2183-3360
E-mail: [email protected]
HIOKI USA CORPORATION
TEL +1-609-409-9109 FAX +1-609-409-9108
http://www.hiokiusa.com / E-mail: [email protected]
All information correct as of Nov. 8, 2016. All specifications are subject to change without notice.