- No category
advertisement
◉
Touch to zoom
® Undercounter Dishwasher PRODUCT MODEL NUMBERS DU400SWK DU600PWK DU620PWK DU800SWK DU810SWK DU810SWL DU811SWK DU811SWL DU840SWK DU840SWL DU850SWK DU850SWL DU890SWK DU890SWL DU900PWK DU909PWK DU910PWK DU911PWK OVERALL DIMENSIONS DU915PWK DU920PWK DU930PWK DU940PWK DU941PWK DU943PWK DU945PWK DU948PWK DU950PWK DU951PWK DU955PWK DU960PNK DU960PWK DU963PWK DUL100PK DUL200PK GU970PNL 23-7/8" (60.6 cm) 24" (61 cm)* 33-7/8" (86 cm) min. * to front of door frame Electrical: 120-volt, 60-Hz, AC-only, 15- or 20-amp. electrical supply. Use copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended. Water: A hot water line with 20-120 psi (138-862 kPa) water pressure. Water temperature must be 120°F (49°C) at dishwasher. Use 3/8" O.D. copper tubing with compression fitting or flexible stainless steel braided fill line (1/2" minimum plastic tubing is optional but not recommended). Use a 90° elbow with 3/8" N.P.T. external pipe threads on one end to connect to water inlet valve. Do not solder within 6" (15.2 cm) from water inlet valve. Drain: Use the new drain hose supplied with your dishwasher. If this is not suitable, use a new drain hose with a maximum length of 12 feet (3.7 m) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the drain connector of the dishwasher. Must have a high drain loop 20 inches (50.8 cm) above the subfloor or floor. Connect drain hose to waste tee or disposer inlet above drain trap in house plumbing and 20 inches (50.8 cm) minimum above the floor. An air gap must be used if the drain hose is connected to house plumbing lower than 20 inches (50.8 cm) above subfloor or floor. Use 1/2" minimum I.D. drain line fittings. Corner installation: Allow 2" (5,1 cm) minimum between corner wall and dishwasher opening. Grommet is required for electrical cable or power supply cord hole cut in a metal cabinet. 20-3/4" (52.7 cm) CABINET OPENING DIMENSIONS 24" (61 cm)** * Measured from the lowest point on the underside of countertop. ** Minimum, measured from narrowest point of opening. 34" (86.4 cm) min.* 24" (61 cm) 6"(15.2 cm) 6"(15.2 cm) 4" (10.2 cm) 4" (10.2 cm) 4" (10.2 cm) 10" (25.4 cm) 2-1/2" (6.4 cm) 2-1/2" (6.4 cm) Do NOT install dishwasher over carpeted floor. Accepts custom door panels: DU800SWKU, DU810SWKU, DU811SWKU Accepts custom door and access panels: DU840SWKU, DU890SWKU, Other models require trim kits in order to add custom panels. The panels must be made to the dimensions supplied with the trim kit. 2" (5.1 cm) 5" (12.7 cm) 5" (12.7 cm) Water line should enter through the left side of opening in shaded areas. Minimum 1/2" (12,7 mm) hole. 2" (5.1 cm) Power supply line should enter through the right side of opening in shaded areas. Power supply line hole-direct wired: 3/4" (1.9 cm) Power supply line hole-with plug: 1-1/2" (3.8 cm) Drain hose should enter through cabinet in shaded areas. Drain hose size: 1-1/2" (3.8 cm) CUSTOM FRONT PANEL DIMENSIONS 7/32" (5.6 mm) door panel (front view) Note: Access panel is wider than door panel. door panel (side view) 18 21/32" (47.4 cm) maximum weight is 8 lbs (3.6 kg). Heavy duty door springs required for door panels weighing more than 4 lbs (1.8 kg). 4 7/16" 11.3 cm (top view) Cut door panel to clear access panel when door is in open position . side view 23 5/16" (59.2 cm) 3/8" (9.5 mm) 1" (25.4 mm) access panel (front view) All edges routed to 7/32" (5.6 mm) thickness. Note: This panel is wider than the door panel. door opened Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. door pivot 7/32" (5.6 mm) thick 7/32" (5.6 mm) 22 31/32" (58.3 cm) door closed access panel frame access panel 1/4" (6.4 mm) min. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. 3385181 07-23-03
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement