Ranger Catalogue
Ranger
Power Quality Analyzers & Data Loggers
V o l t s ● a m p s ● Wa t t s
Va r s ● P ow e r Fa c t o r
P h a s e A n gl e ● h a r m o n i c s ● f l i ck e r
iNTERHARMONICS
1
PM7000 POWER QUALIT Y RECORDING ANALYZER
Each Unit Includes








Five Fused Voltage probes 600V
Cat IV Pollution Level 2
Four 24" 6000A/400.0A Flexible
Current Clamps (max conductor size 8")
Pronto for Windows Analysis Software
Operation Manual on CD
Bluetooth Adapter for laptop or PC
12 Volt Charger & Carrying Case
1 year warranty
NO Cost lifetime upgrades for
Software & Firmware
10 Reasons to Consider Ranger PM7000
1. Input leads fusing is - STANDARD, because for us, SAFETY is NUMBER 1—EXCLUSIVE
Also, Isolation, both, between channels AND for Communications
2. Compliant to IEEE 1453 Flicker Specification released May 2005. ONLY Ranger loggers can
provide the required "NEW" Instantaneous Flicker (see page 13) Output for the
ENTIRE LENGTH OF RECORDING with FLICKER FLAG
VALIDATION FOR SHORT & LONG TERM FLICKER
3. RECORDS 32 Detail Channels simultaneously with single cycle resolution on changes,
BECAUSE of our: EXCLUSIVE PATENTED “SINGLE CYCLE ADAPTIVE STORE"
4. High speed sampling on ALL inputs including 4 Currents and 4 Voltages.
5. Auto-ranking of waveform capture greatest disturbances—Ranger EXCLUSIVE
6. 128 Meg on board memory. USB Memory Device auto write, is standard (very powerful)
7. Wireless communications to remote PC or PDA allows utility personnel access to PM7000
display, without suiting up as required by NFPA 70. Check out our ITIC/CBEMA event display.
8. Supports IEEE100, IEEE1459 & power triangle power math methods, making available
"Distortion Power" (IEEE100), "Non-Fundamental Apparent Power" & "Fundamental Positive
Sequence Reactive Power" (IEEE1459) - for sizing Power Factor Correction capacitors.
9. Interharmonics Option-PM7000 is the best instrument on the market-we’re the experts,
Page 14 & 15
10. Phasor Diagram Display of individual harmonics, NOT just the fundamental
2
P M 7 0 0 0 S P E C I F I C AT I O N S
Input Voltage FOUR FUSED 0-600 Vac Safety Banana Leads
Configurations On Board Storage of over 200 configs
Input Current Four Sensors 2 ranges 6000A or 400.0A
Data Retention Flash Memory: During recording sequential data is saved to Flash memory. Waveform capture data is held in RAM and transferred to Flash memory when recording .
Channels 32 Channels Single Cycle Adaptive Store™ for
detail data and troubleshooting,
Accuracy < 0.25% excluding sensors, +/- 2LSDs
(in target ranges)
Programmable
Math Channels
Recorded using
Adaptive Store
For extra detail
and/or
troubleshooting
Waveform
Capture
Wave Allocation
Wave Sets
Recording
Memory
Recording
Mode and Rate
Fixed Functions
Recorded on
(selected)
Intervals (Max,
Min, Avg)
>492 CHANNELS
User Interface Via Remote Screen: PC via Bluetooth,
USB or Ethernet (optional) Running
PMScreens or Pronto.
Menus include setup, configuration, & real
time data review.
AC 1 Phase: RMS, Stray Voltage RMS Hi Res <
35V,Real power, VARS, Apparent Power, Phase
angle, Power Factor (Real & Displacement),
Frequency, Instantaneous Flicker Sensation, Flicker
Displays PMScreen: Over Bluetooth to program and
Flag, (Pst, Plt already recorded)
display Power & Energy, Waveforms, HarAC 2 Phase: Real Power, VARS, Apparent
monics, Phasors, Harmonic Phasors, Trends,
Power, Power Factor
Statistics, list of channels & more
AC 3 Phase: Real Power, VARS, Apparent Power,
Power Factor, Voltage Unbalance (Conventional &
Sequential Components),
Communications Bluetooth: Wireless interface (isolated)
Current Unbalance
USB: Serial interface to PC
(isolated > 2.5kV)
Harmonics: Total Harmonic Value, % Total
Ethernet:
- Optional
Harmonic Distortion, Odds, Evens, Triplens and
individual harmonics with direction, K-Factor
Power Requirements: Powered from V1 input
Interharmonics, optional
(90-660 VRMS, 15W Max) OR from
Basic Maths: Channel X * Constant, Channel X/
charger input @ 12Vdc, 6W Max.—Auto
Channel Y,Filtered Channel X, Internal Temperature,
Switching
On Charge, Battery Volts
Battery Capacity: 1600mAhrs
Sample Rate: 8 channels at up to~ 1.2288Ms/s
( Five HI-Temp NiMH batteries)
(~20,480 samples / cycle)
Charge Method: From V1 input or from
Waves allocated across trigger functions
12V Wall Charger (auto switching) Battery
Ride Through: 10 minutes at a time
Dependent of length of capture, pre/post buffers
A/D Converter Resolution: 24 bit (top 16 bits used norPM7000S —Sample rate per cycle ~ 320
mally)
PM7000H —Sample rate per cycle ~ 2560
Resolution Programmable to 0.1 Vac and 0.1 Aac
PM7000T —Sample rate per cycle ~ 20,480
(0.01V high res mode)
128MB Flash memory for all files
Environmental Operating & Storage Temp:
32MB RAM for waveform capture data 64MB
-10º F to 140º F
working RAM Firmware (program memory)
Case Type: Pelican 1150 Box
2MB Flash upgradeable
User Preferences - Stored in non-volatile RAM/
Dimension: 9" x 7.5" x 4.3"
EEPROM
Weight: 7.7 LBS
IP Rating: IP67 (immersion for limited time)
Point Store: Selectable from single cycle rate to once
every 12 hours
Certification IEC 61010 (600V Category IV. Pollution
Adaptive Store: Extended recording with
level 2,1000V Cat III if PSU fuses resingle cycle (half cycle?) resolution on changes.
moved), CE Fused voltage leads (lead fuses
Statistics closed (at least) every 5 minutes.
500mA, 1000V, 50kA rupture current),
General Store: Statistics to IEC EN50160 via
GS38 compliant
PC Software
Internal Fusing: PSU (x2), Charger input,
Waveforms: Examined RANKED and stored in real
Battery stack Internal Thermal Fuse
time at full speed—Exclusive
IEC61326 (EMC), IEC61000-4-15,
IEEE1453 (Flicker)
Voltage & Current RMS (8 inputs), THD/Harmonic
Value (8 inputs), Power (kW, VAR, AP, PF)
Computer For Pronto Software: Windows 9x, ME, NT,
Individual Harmonics 2-51 ( 8 * 50 signals)
Requirements XP , Vista & Windows 7
(127th with Interharmonics option)
General Store avg. adjustable 1 sec— 1 hour
Applicable Patents 6424277, 0230712, 4910692
3
P M S C R E E N P RO G R A M M I N G D I S P L AYS — P M 7 0 0 0
4
P M7000 PM Sc reen p rogr am min g Ex amples
Fo r “ R E A L T I M E ” C o m p l i a n c e & E v e n t P r e s e n ta t i o n s
5
PM3000 Pow er Quality Meter Socket Logger
Each Unit Includes
 PM3000HF Power Quality & Harmonic Logger
 Three 24" 3000A/400.0A Flexible Current Clamps
(max conductor size 8")
 Four Fused Voltage Input Cables, 9-Pin Serial Download Cable
 Two Neutral Common Jumpers, 12 Volt Charger
 Pronto for Windows Analysis Software
 Operation Manual on CD, Training Video, Carrying Case
 NOW Available - Optional Bluetooth and DC Measurement
FEATURES
 Patented Single Cycle Adaptive Storage
 15 pre-stored configurations are set for 3 phase, 2 phase, and sin-
gle phase hook ups with several math channels pre–configured
One Meg memory provides single cycle event resolution over
for power, harmonic & Flicker measurements
recording periods of 30 days with all 16 channels recording Standard
 Fused voltage leads and internally fused voltage inputs protect
expensive equipment - Standard
 Graphical touchscreen interface provides straightforward,
user-friendly operation
 Exclusive - Capable of storing up to 127 configuration or data
files
 Resident on-line HELP guides users through configuration
and hook up
 Built in connection wizard ensures correct hook up, provides
suggestions upon detecting errors and determines if current sen Records and displays up to 16 channels of voltage, current,
sor is properly orientated
power, power factor, VAR’s, phase angle, frequency, THD, K
Factor-Standard
 Phasor Diagram Display to ensure correct hook up and show the
phase relationship of individual harmonics
 Records & Displays Harmonics: Odd, Even, Triplens and
 RS232, with MODBUS ASCII and modem compatible Data
Individual with direction to the 15th
Storage includes an additional internal flash memory for field
 RECORDS & DISPLAYS Instantaneous Flicker Sensaprogrammable upgrades
tion over the entire recording session, as well as programmable time periods for long & short term flicker—Ranger /  Safety Benefit: Very small size, will fit in most panels and allow
Pronto Exclusive
the door to be closed
 Battery back up provides 10 minutes resettable timed ride Lowest Cost 3 Phase Power Quality & Harmonic Logger on the
through in case of power outage
market today—rugged, compact, portable case is lockable
 Powered independently by AC measurement circuits or DC
power supply for voltages below 50 volts
SPECIFICATIONS
Input Voltage Four 0-525 Vac/DC Inline shrouded 4mm banana plugs
and fused dolphin clips
Recording 3840 samples per second; Single Cycle True RMS response
time; 16 bit simultaneously sampling all channels
Input Current Three 24" 3000A/400.0A (software selectable) Flexible Current
Memory
Clamps Included, or with optional conventional 0-0.5 Vac/DC
Recording
current clamp voltage output. Various DC Probes available.
Mode and Rate
Channels 16
Accuracy Volts and wide range current < 0.25% True RMS
Narrow range current < 1% True RMS
Data Retention
Resolution Programmable to 0.1 Vac and 0.1 Aac
0.01V, 0.01A high resolution mode
Math AC 1 Phase: RMS, Stray Voltage RMS Hi Res < 35V,
Channels Real power, VARS (fund), Apparent Power,
Power Factor, Phase angle, Frequency
AC 2 Phase: Real Power, VARS (fund), Apparent Power,
Power Factor
AC 3 Phase: Real Power, VARS, (fund), Apparent Power,
Power Factor, Voltage Unbalance, Current Unbalance
(Conventional & Sequential Components)
Harmonics: Value and / or percentage of total harmonic
distortion, odd, even, triplens and individual harmonics
with direction to the 15th.
Records & Displays Instantaneous Flicker Sensation
over the entire recording session, as well as programmable
time periods for long & short term flicker— Ranger / Pronto
Exclusive
1MB Ram - Standard / Approximately 4MB uncompressed
Adaptive Store: Unique store management enables extended
recording & Single Cycle resolution on significant signal
changes
Point Store: Selectable from Single Cycle rate to once
every 12 hours
Back-up battery provides 3 month’s retention @ 77ºF (25ºC)
Power Requires 50-525 Vac off of Phase A voltage measurement or
separate power supply
Battery: 4 AA NiMh Batteries & 1 Lithium battery
Communica- Serial Ports: RS232, (up to 230.4K baud); isolation>2.5kV
tions Protocol: MODBUS ASCII
Computer Requirements for Pronto Software: Windows 9x,
ME, NT, XP, Vista & Windows 7: 486DX66 or higher; 250MB
hard drive:16MB RAM
Display Backlit LCD graphic touchscreen display 2.5" x 1.35"
Case Pelican 1120 Guard Box: Dimensions 8" x 6.5" x 3.5"
Weight 2.5lbs. without leads and clamps / Complete Kit 8 Lbs.
Operating -4º F (-20º C) to 140º F (60º C)
Temp
Certification IEC 61010, Cat. III, Pollution Degree 2; CE
6
S i x R E A S O N S TO CO N S ID E R R A N GE R P M 3 0 00 Ha rm on i c L og ge r
1. INPUT LEAD FUSING IS - STANDARD, BECAUSE FOR US, SAFETY IS NUMBER 1
2. COMPLIANT TO IEEE 1453 FLICKER SPECIFICATION
RELEASED MAY 2005 - ONLY RANGER LOGGERS CAN PROVIDE THE
REQUIRED "NEW" INSTANTANEOUS FLICKER OUTPUT FOR THE
ENTIRE LENGTH OF RECORDING UP TO 14 DAYS (see page 13)
WHILE RECORDING ALL 16 CHANNELS AVAILABLE
3. RECORDS 16 CHANNELS SIMULTANEOUSLY FOR 2 WEEKS WITH SINGLE CYCLE
RESOLUTION ON CHANGES BECAUSE OF OUR:
EXCLUSIVE PATENTED "SINGLE CYCLE ADAPTIVE STORE"
4. HARMONIC DIRECTION SHOWS IF HARMONICS ARE:
UPSTREAM OR DOWNSTREAM FROM THE POINT OF MEASUREMENT
5. STORES UP TO 127 CONFIGURATIONS ON BOARD
ELIMINATES THE NEED TO PROGRAM ON SITE
JUST CHOOSE A CONFIGURATION, PRESS LOAD & START
6. PHASOR DIAGRAM DISPLAY TO ENSURE CORRECT HOOK UP AND SHOW THE PHASE
RELATIONSHIP OF INDIVIDUAL HARMONICS, NOT JUST THE FUNDAMENTAL
P M 3 0 0 0 H F D I S P L AY S C R E E N E X A M P L E S
Comes with 15 Pre-Stored Configurations. Just choose through the communication port OR
program your own, with the Included PMScreen Software
Graphical LCD Touchscreen (backlit) Display Interface
PRONTO Software is included with all PM Products, AND
LIFETIME UPGRADES for software & firmware at NO COST
7
PM2000 Power Quality Meter Socket Loggers
PM2000F Power Quality Meter Socket Logger OR
PM2000F-300BT Power Quality Meter Socket Logger
(for socket class 320)
Each Unit Includes:
 Pronto for Windows Analysis Software
 Infrared USB Download Cable
 Neutral Blade & Neutral Clip Lead
 LED Legend Card, 12 Volt Charger & Carrying Case
PM2000F-300BT
 Operation Manual and Training Videos on CD
 Bluetooth standard on the PM2000F-300BT, Optional on the PM2000F
FEATURES
 Patented Single Cycle Adaptive Storage - One Meg memory
provides single cycle event resolution over recording periods of 30
days with all 16 channels recording— Standard
 FIVE externally visible status LEDs (4-bi-color)
 Twelve pre-stored configurations are set for split phase hook ups with
several math channels pre–configured for power, harmonic, and
Flicker measurements
 Infrared Optically Isolated Noncontacting RS232, with MODBUS
ASCII
 Rogowski coil technology ensures the most accurate current readings  Records and displays up to 16 channels of voltage, current, power,
power factor, VAR’s, phase angle, frequency, THD Harmonic Readouts on all voltage and current channels - Standard
in a low current measurement situation
Accurate current readings to zero amps
 RECORDS & DISPLAYS Instantaneous Flicker Sensation
over the entire recording session, as well as programmable time
periods for long & short term flicker—Ranger / Pronto Exclusive
 Data storage includes an additional internal flash memory for field
programmable upgrades
 Battery back up provides 10 minutes resettable timed ride-through
in case of power outage
 Works with 1S, 2S, & 12S Meter Sockets
 PM Meter Software to show digital display of all 16 channels
 PM Wave Software shows waveform of all input channels
 PM Screen Software for virtual screen display, configuration, and
operation (launched through Pronto for Windows) - Standard
 Measures voltage L1 to L2 (we don’t calculate it), L1 to neutral,
L2 to neutral, Measures current in L1 and in L2—Standard
 Compact size Marwell socket case
SPECIFICATIONS
Input Voltage Three 0-300 Vac True RMS
Input Current Two 0-220 Amp Rogowski Type Rigid Coil
Sensors Industry Exclusive feature:
Allows extremely low level accurate current
sensing down to 0 Amps
Input Current Two 0-300 Amp Rogowski Type Rigid Coil
PM2000F- Socket Class 320
300BT
Channels 16
Accuracy Voltage < 0.25% True RMS of Reading
Current < 0.5% True RMS of Reading
Resolution Fixed to 0.1 Vac and 0.1 Aac
Math AC 1 Phase: RMS, Real Power, VARS (fund),
Channels Apparent Power, Power Factor, Phase angle,
Frequency
AC Split Phase: Real Power, VARS (fund),
Apparent Power, Power Factor
Records & Displays Instantaneous Flicker
Sensation over the entire recording session,
as well as programmable time periods for long &
short term flicker—Ranger / Pronto Exclusive
Harmonics: Total Harmonic Value,
% Total Harmonic Distortion
Other Math Option: Channel X * Constant,
Channel X / Channel Y, Filtered Channel X,
Internal Temperature, On Charge, Battery Volts
Memory 1MB Ram - Standard / Approximately 4MB uncompressed
Recording 3840 samples per second; Single Cycle True RMS
response time; 16 bit simultaneously sampling all
channels
Recording Mode Adaptive Store: Unique store management enables
and Rate extended recording & Single Cycle resolution on
significant signal changes
Point Store: Selectable from Single Cycle rate to
once every 12 hours
Data Retention Back-up battery provides 2 month’s retention @ 77ºF (25ºC)
Power Requires 100-300 Vac from L1 to L2 voltage
measurement or separate power supply
Battery: 4 AA NiMh Batteries & 1 Lithium battery
Customer Replaceable
Communications Serial Ports: Infrared Optically Isolated, non-contacting
RS232, (up to 115.2K baud)
Protocol: MODBUS ASCII
Computer Requirements for Pronto Software:
Windows 9x, ME, NT, XP, Vista & Windows 7
486DX66 or higher, 250MB hard drive: 16MB RAM
Bluetooth: Wireless Bluetooth standard on the
PM2000F-300BT, Optional on the PM2000F
Case Marwell Socket
Weight 2.6 lbs.
Operating Temp -22° F (-30° C) to 140° F (65º C)
8
FIVE REASONS TO CONSIDER RANGER
PM2000F Meter Socket Logger
ONLY Meter Socket Logger Compliant to
IEEE 1453 Flicker specification released May 2005
1. ONLY RANGER LOGGERS CAN PROVIDE THE REQUIRED "NEW"
INSTANTANEOUS FLICKER OUTPUT FOR THE
ENTIRE LENGTH OF RECORDING UP TO 14 DAYS (see page 13)
WHILE RECORDING ALL 16 CHANNELS AVAILABLE..
2. WE DO NOT COMPUTE L1 TO L2, WE MEASURE IT….
3. WE USE AIRCORE ROGOWSKI COIL CT’S IN THE SOCKET AND CAN ACTUALLY
READ DOWN TO 0 AMPS AND UP TO 220 AMPS. UP TO 300 AMPS WITH THE
4. RECORDING AUTOMATICALLY STARTS AFTER 1 MINUTE –
NO ROOM FOR HUMAN ERROR.
5. RECORDS 16 CHANNELS SIMULTANEOUSLY FOR 2 WEEKS WITH SINGLE
CYCLE RESOLUTION ON CHANGES BECAUSE OUR
EXCLUSIVE PATENTED "SINGLE CYCLE ADAPTIVE STORE"…..
GIVES UNPRECEDENTED DETAIL
PM2000HF VIRTUAL DISPLAY SCREEN EXAMPLES
12 Pre-stored Configurations
Just choose through the infrared communication port or program your own, with the
included PMScreen Software
9
Ranger PM1000
Single Phase Power Quality Analyzer and Flicker Meter
Each Kit Includes
PM1000 Power Quality, Harmonic and Flicker Analyzer
 24" 1000 Amp Flexible Current Clamps
(max conductor size 8")
 Infra Red USB Download Cable
 Mains Input Cable
 Pronto for Windows Analysis Software
 Manual on CD
 Protective Boot
 Carrying Bag

FEATURES
The PowerMaster 1000 Single Phase Logger is a 3-channel data logging system built into an easy to carry
housing. It is ideal for responding to residential voltage complaints and power consumption problems.
It monitors line to neutral and neutral to earth voltages and one current signal that accepts Rogowski coils or
traditional current clamps. Flicker Measurements are made to IEC 61000-4-15. Data is retrieved via an infra-red
or (optional) Bluetooth serial port. Date and time, recording length, recording mode, sample rate, math channel
usage and more can be configured from a laptop or personal computer via the serial port.
SPECIFICATIONS
Input Voltage: 2 channels, 0-270 Vac, Live to Neutral
and Neutral to Earth
Input Current: 1 channel, ranges 0-1000 A rms and 0-50
A rms. Sensing using a flexible Rogowski Coil. Also
works with standard CT’s
Channels: 16
Accuracy: Volts and wide range current < 0.25% True
RMS +/-2 LSB’s excluding sensors.Narrow range current
< 1% True RMS excluding sensors
Resolution: Programmable to 0.1 Vac and 0.1 Aac or
0.01V and 0.01A high resolution mode
Maths Channels:
AC 1 Phase: RMS, Stray Voltage RMS Hi Res < 35V,
Real power W, Reactive Power VARS (fund), Apparent
Power VA, Power Factor PF, Phase Angle, Frequency,
Instantaneous Flicker Sensation, Short Term & Long
Term Perceptibility, Flicker Flag
Harmonics: Total Harmonic Value, % Total Harmonic
Distortion
Other Maths Option: Channel X * Constant, Channel X /
Channel Y, Filtered Channel X,
Internal Temperature, On Charge, Battery Volts
Sampling: Continuous sampling at 64 samples per cycle;
Recording: Single cycle True RMS response time; 16 bit
simultaneously sampling all signals
Recording Mode and Rate:
Adaptive Store: Unique store management enables extended recording & single cycle resolution on significant
signal changes
Point Store: Selectable from single cycle rate to once
every 12 hours
Memory: 1 MB RAM
Data Retention: Back-up battery provides 1 month’s retention @ 25ºC (77ºF) from a full charge
Safety & Standards: IEC 61010 (300V Cat III, Pollution
level 2), CE, IEC 61326 (EMC), IEC 61000-4-15
Internal fusing: PSU, Battery stack, fused voltage lead
Communications:
User Interface: 3 status LEDs (Power on, Voltage in spec,
Recording /Memory)
Serial Port: Serial infra red port, (up to 115.2K baud);
isolation >2.5 kV and/or Bluetooth (wireless)
Protocol: MODBUS ASCII
Computer Requirements for Pronto Software: Windows
98, ME, NT4, XP, 2000, Windows 7, Pentium class processor or higher, 32 MB RAM,
Case: Rectangular box enclosed in a protective boot. Dimensions: 215 mm x 116 mm x 45 mm including boot.
Weight: 900 gm including boot
Operating Temp: -10º C (14º F ) to 60ºC (140º F )
10
Synergy Systems
Meter Socket Interface Series
The MSI series of meter socket interfaces are designed to allow safe and simple connection of recorder
products to commercial and industrial revenue meter sockets.
The unit incorporates integrated current transformers for direct current sensing, as well as voltage readings
for 3 and 4 wire configurations on a wide variety of meter bases.
Features
 3 voltages and neutral available
 Current outputs mV/A or mA/A
 Compatible with 200/320 amp services
 Direct connect to 12S and 15S meters compatible with both ringed or ringless bases
 Custom configurations available upon request
Safety
 Water Resistant
 Voltages fuse protected
 CTs are open circuit protected
TWO PIECE DESIGN ALLOWS ONE DATA LOGGER INTERFACE TO CONNECT
TO A VARIETY OF METER SOCKETS
Data Logger Interface
Model
Meter Socket Adapter
12S or 15S
DL3
DL6
Interfaces to
PM3000, PM7000
PM6000
Output Type
Banana/BNC
Fixed Cables
Cable Length
10ft *
10ft
Note: * units come with 4 banana to banana for voltage
connections and 3 BNC to BNC for current connection
Socket Adapter
Model
SA212
Configurations
Meter Form
SA312
Current Range
3 Phase 4 Wire
12S
14S, 15S, 16S, 17S
600 VAC
200 AAC
320 AAC
200 AAC
0.5 to 200 0.5 to 280 0.5 to 200
AAC
AAC
AAC
CT Ratio
1000:1
Accuracy
1% of Reading

SA315
3 Phase 3 Wire
Voltage Rating
Max Current
SA215
DL6—For use with a
Ranger PM6000
Contact us for custom configurations
320 AAC
0.5 to 280
AAC
DL3—For use with a
Ranger PM3000/PM7000
11
Pronto — Sof tware for R angers
However clever the Ranger instrument is, however much information it collects, however accurate is the data,
of most interest to you the user is the answer to ‘how easy is it to make use of my data?’
The answer lies with Pronto. Our software Pronto first came out in 1985. From the start emphasis was placed
on making Pronto easy to use, useful and reliable. By the year 2000 Pronto had reached its fifth
generation. Pronto for Windows has benefited particularly all users who wish to make full use of the
Microsoft ® Windows Operating System.
Pronto and Adaptive Store make a strong partnership. Here’s a scenario.
‘Start a Ranger recording. (That’s easy as well). We make sure the factory default set up is a most useful one
and in this case the logger will record for 7 days. At the end of the recording download to Pronto and see the
data take form in the graphs or reports you choose. Clear instructions guide you the first time. Note the detail
you are getting, down to a single cycle. Zoom in and out. Label points.
Note the many parameters that have been recorded for you by the Ranger.
There are fewer cries of " I wish I had remembered to set up to record…."
Look at your data values, perhaps the maximums or minimums are not what you expected. Now, even after
your recording is finished, you may choose to produce out of limit (exception) reports. They can now depend
upon the results your Ranger has just given you.’
Rangers with Pronto and Adaptive Store will look after you.
For the final answer to your question, ‘how easy is it to make use of my data?’ watch our 54 minute video on
‘How to use Pronto’. It comes with your Ranger kit.
You will find the world of Power Quality opening up in an exciting way.
Pronto For Windows data analysis & reporting software
File Management Tools



Templates for Viewing Data



Pronto for Windows Explorer

Sample Graphical Data of Voltage & Current
Exceedence Report - Multiple Reports
Generated after recording is concluded










Waveform Capture Analysis
(PM7000 Only)
Harmonic Analysis of Waveform Events
(PM7000 Only)
FEATURES



Logger Configuration Saved with
Data for Retrieval at any time
Unlimited Traces on Screen
Titles, Subtitles & Legends for
Text & Data
Text Annotation
Arrow Pointer for Text
Cut & Paste Graphs to emails and
any Word Processing Program
Font Selection of Size & Type.
Color Selection for Text & Graphs
User Information Screen
Local Data Logger Network Support
Remote Data Logger Network Support
Notebook
Export data to spreadsheets
38.4 K Baud up to 921 K Baud
Configure Logger
Zooming Tools
Frame
Pan
Exception Zooming
Limits (value or %)
Reporting Tools
Exceedence Reports
Customer Statistics
Tabular Listings
Custom Reports
Context-Sensitive, On-Line
Help System
Used with all Ranger &
Adaptive Store Products
12
Flicker in the r anger pm series
What is Flicker?
Flicker is the name given to changing light intensity caused by fluctuations in the voltage. It is the second most
common power quality problem, causing both irritation and possible medical
consequences to users exposed to its effects.
Why are the Ranger Power Masters the best analyzers for
measuring and analyzing Flicker?
Rangers calculate and record the Instantaneous Flicker Sensation, Short Term Perceptibility,
and Long Term Perceptibility. (These are known as Pfs, Pst and Plt respectively.)
A Pfs measurement of 1 is the point at which 50% of the human population becomes aware of the flicker.
A Pst of 1 describes the point at which 50% of the population actually becomes irritated by the flicker while Plt
indicates the irritation caused by irregular flicker effects over a longer period.
In Ranger PM Products all three parameters are derived using the IEEE 1453 and IEC 61000-4-15
model for human behavior.
The measurement process meets all the Flicker Tests specified in both Standards, and in
addition meets the linearity tests being proposed by CIGRE for the highest class of instruments.
CONFORMS TO
IEEE 1453
Our Software
Displays & Prints
Instantaneous
Flicker Sensation
For the Entire Length
of
Recording
A Ranger / Pronto
Exclusive
Ask our
competitors to show
you if they can do this
for 7 days with 16
channels recording
simultaneously
Detailed Flicker Report—For a complete 7 day recording period
The above Graph is the True RMS value of the Voltage Channel being tested for FLICKER.
The Instantaneous FLICKER
(or Flicker Sensation, a Ranger Exclusive) Graph, shows there is
continuous Flicker present on the voltage being tested for 7 days.
The Short Term Flicker Graph is based on a 10 minute time period
(Programmable time period, with PM Products Only)
The Long Term Flicker Graph is based on a 2 hour time period
(Programmable time period, with PM Products Only)
13
RECORDING INTERHARMONICS —PM7000
Interharmonics are available to be recorded as individuals (specified by Harmonic if an integer number or by
frequency), and/or as Interharmonic or Harmonic Groups and Sub-groups. They may be referenced to the
appropriate fundamental grouping if desired. In all there are 12 selection methods:
Interharmonics are recorded in the PM7000 as Detail Troubleshooting Channels using the Adaptive Store
or Point Store methods. The Interharmonics Function Group selection screen is populated with the twelve
selection possibilities. Choosing any of these functions leads to a choice of relevant parameters, signal and
harmonic etc., thus complete flexibility is available.
Today more and more companies are concerned with interharmonics. Interharmonic frequencies are not
integer multiples of the fundamental frequency (i.e.- 120hz = 2nd harmonic on a 60hz system), but are all
other frequencies that are between the multiples (i.e.- 122hz, 75hz).
Interharmonics exist alongside the fundamental and other harmonics. They cause irregular distortion and
can cause strange effects in sensitive equipment .
InterHarmonics Calculations
Harmonics, Harmonics Groups and Sub-groups; InterHarmonics, InterHarmonics Groups and Sub-groups
are all available and calculated according to IEC61000-4-30 (which calls IEC 61000-4-7).
IEC 61000-4-7 calls for a Transform input time of ~200ms (10 cycles at 50Hz or 12 cycles at 60Hz) and
hence the bandwidth is nominally 5Hz. The diagram below shows the 60Hz case:
Note that as shown in the diagram the spectrum is in fact continuous, and not just a series of lines. However the transform methods usually used for computational convenience only yield results at the above
line intervals (50Hz, 60Hz or 5Hz), so the spectrum is often represented as a line spectrum.
Having resolved the spectrum into 5Hz elements, the authors of the Standards defined various groupings
of 5Hz elements to describe harmonic energy in the chunks appropriate to different applications.
(See the IEC 61000-4-7 Standard for further application information).
14
RECORDING INTERHARMONICS —CONTINUED
The groupings are of six types (A) to (F), as shown below:
These are:
(A) Individual Harmonics. This grouping is just the single line at an integer harmonic frequency.
(In this case the 2nd Harmonic, 120Hz.)
(B) Harmonic Sub-groups comprising integer harmonics plus the two adjacent Interharmonics.
This grouping shows the 3rd Harmonic Sub-group around 180Hz.
(C) Harmonic groups. These Groups comprise all the energy from half-way between the harmonic below the nominal to half-way above. The components at 210 and 270Hz are halved so that between them, the Groups centered on (e.g.) the 3rd and 4th harmonics (which both have contributions from the Interharmonic line at 210Hz)
use 100% of all the available components.
The above three groupings are centered on actual harmonics. In addition to individual Interharmonics ((D) below) there
are also two groupings centered halfway between harmonics to deliberately exclude harmonics themselves:
(D) Individual Interharmonics. This grouping is just the single line at a non-integer harmonic frequency.
(In this case at 45Hz.). [Individual Interharmonics are sometimes indexed as the Nth Interharmonic of the Mth
harmonic group, in this case 0:9 (9th Interharmonic of the Zeroth harmonic = 0 * 60 Hz + 9 * 5Hz = 45Hz).
Because of the need to accommodate 50 and 60 Hz in the PM7000 and the possibility of this indexing being
ambiguous, the frequency itself is used.]
(E) Interharmonic Sub-groups. These Sub-groups contain the lines not included in the Harmonic Sub-groups.
The Sub-group shown (E) comprises the 70 Hz to 110 Hz contributions, and for the PM7000 this is described
as the Sub-group below the 2nd Harmonic.
(F) Interharmonic Groups. These Groups contain all the lines between integer harmonics. The Group shown (F)
has contributions from 185 to 235 Hz, and in the PM7000 nomenclature is described as the Group below
the 4th Harmonic.
Notice how the Interharmonic Sub-group and Group contributions complement the Harmonic Sub-group and Individual
Harmonics respectively.
Parameter values for group and sub-groups combinations are calculated from the Root Sum Squares of the relevant individual Interharmonics, and each final result is filtered with 1.5sec time constant first order filter.
.
15
R e c o m m e n d e d R a n ge r Ac c e s s o r i e s
Condensation Protection Kit For Ranger PM3000 and PM7000
The combination of a Baja Bag and Zorb It provide the best possible solution for keeping your Ranger PM3000 and PM7000 from just about any
abuse from Mother Nature. The Baja bag is made of 19 oz. vinyl sides
and a heavy-duty 30 oz. bottom and close with their Dry Seal ™ roll-top
Closure Reliable Protection: Dry Seal ™ roll-top Closure ensures the best watertight
seal possible. The Zorb-It™ is a unique, patented, double-action™ agent for the positive control of moisture and humidity. It is no mere desiccant. The Zorb-It formulation has been
proven effective in the toughest industrial environments around the world. We suggest you put one of
these inside the lid of your PM3000 or PM7000.
PM Series precision current clamps
Model Shown
Part # PM0245
Applications
 5A secondary current transformers
(CTs) monitoring
 Measuring in breaker panels
 Industrial loads
 HVAC
 Residential and commercial sites
 Data logging and recording
Features
 Small, compact size





Measurement range of 1 mA to 10A Current Range
Large jaw opening accommodated conductors
up to 250MCM
Designed for DMMs, loggers, recorders and
oscilloscopes
Available with mA or mV output signals
Conforms to EN 61010, 600V Cat. III
PM Series Long Life Flexible Current Sensors
Applications
 Will work where a standard CT won't fit
 Flexible AC Probes offer excellent linearity and a True RMS output that is insensitive to any DC components.
Features
 Two AA batteries (included) will power
these units for a minimum of 2000 hours in
continuous operation
 No-clip connector






Internal electrostatic shield
No core saturation or damage if overloaded
EN 61010, 1000V Cat. III (sensor); EN
61010, 600V Cat. III (module)
Two Standard units
24" 5000A / 400A and 12" 2000A / 200A
Safety BNC Connector
Other sizes & ranges are available
Contact us for special range & length availability
Portable utility / equipment shelf “the Utilishelf”
FOR USE IN THE FIELD TO INTERROGATE ELECTRIC METERS, OR DOWNLOAD
EQUIPMENT MONITORING DEVICES ON:
 Meter enclosures
 Pedestal Mounted Meters
 Transformer
 Switchgear
16
Was this manual useful for you? yes no