Cε LD 5208 Weighing Indicator

Cε LD 5208 Weighing Indicator
LD 5208 Weighing Indicator
April 2006
B
BA
AS
SIIC
C FFE
EA
AT
TU
UR
RE
ES
S
○
Approved for 10,000divisions
○
Up to 28 measurements per second
○
Excitation for up to 10 strain gauge load cells,
1100Ω each or 4 strain gauge load cells, 350Ω
(minimum input impedance 35Ohm)
The LD5208 is our proposal for
simple and accurate weighing.
The indicator features large crystal
liquid display, compact ergonomic
enclosure for table top or wall mount
use, and battery operation to allow the
use in portable scales or remote
locations.
User friendly, simple and fast in
operation, fully configurable and
easily adapted to your needs, this
indicator is a cost-effective and
reliable solution for a variety of
weighing applications.
A
AP
PP
PLLIIC
CA
AT
TIIO
ON
NS
S
Legal for trade applications
◦
◦
◦
◦
All types of bench and floor scales,
○
Large, 6 digit LCD (20mm) display with backlight.
○
6 keys membrane keyboard with tactile feedback
○
Single or dual interval
○
Analogue and digital filtering
○
Standard RS232 for PC or printer connection
○
ABS plastic table top enclosure
○
Mains adapter powered and by internal
rechargeable battery
○
Auto power off
O
OP
PE
ER
RA
AT
TIIN
NG
GK
KE
EY
YS
S
○
On / off
○
Zero scale
○
Tare key (sets/resets indicator to net mode)
○
Tare recall (displays tare in use)
○
Print key (initiates printouts and adds to total)
○
Total key (displays totals and number of weighings)
Weighbridges
Silo – weight indication and data collection
Computer based weighing systems
S
ST
TA
AN
ND
DA
AR
RD
DS
SU
UP
PP
PLLY
Y iinncclluuddeess::
○ User manual
EEU
U--TTYYPPEE AAPPPPRRO
OVVAALL D
DKK00119999..2277
○ 230 Vac Mains adapter / charger
Cε
RETAIL SCALES , INDUSTRIAL WEIGHING, WEIGHING ELECTRONICS, SOFTWARE, PROCESS AUTOMATION AND SYSTEMS , BULK HANDLING AND BAGGING, ENGINEERING PROJECTS
LD 5208 Weighing Indicator
APPROVALS
ACCURACY CLASS
DISPLAY – KEYBOARD
DISPLAY
STATUS ANNUNCIATORS
KEYBOARD
DECIMAL POINT SETTING
DISPLAY STEP
DISPLAY DIGITS
A/D CONVERTER
TYPE
CONVERSION RATE
SENSITIVITY
ANALOGUE SIGNAL RANGE
RESOLUTION
LINEARITY & STABILITY
LINEARITY
LONG TERM STABILITY
TEMPERATURE COEF.
EU-Type approval for 10,000 divisions (approval Nr.: DK 0199.27) &
III
OIML R76
6 digit, 7 segment, LCD 24 mm
No motion, zero, tare in use, net, in, low, high
6 key membrane keyboard with tactile feedback
Between any digit of the weight display
1, 2, 5, 10, 20, 50, 100, 200 (set-up selectable)
4, 5 (set-up selectable)
Sigma-Delta ratiometric with analogue and digital filtering (FIR & post flitering, rolling average)
3 up to 28 measurements per second (set-up selectable)
0.4µV/VSI for approved scales, 0.1µV/VSI for non-approved scales
-0.25 to 1.75mV/V (-1.25mV to – 8.75mV) or -0.25 to 3.5mV/V (-1.25mV to – 17.5mV)
Internal 550,000 counts, display : 99,000 dd (selectable, in accordance with regulations)
Within 0.002 % of full scale
0.005 % of full scale per year
o
o
Deadload ≤ 2ppm / C, Span ≤ 2ppm / C
SCALE CALIBRATION AND FUNCTIONS
CALIBRATION
Digital calibration (dead load and span) and scale parametrization via keyboard dialogue menu .
The weight display can be set to any capacity and resolution with 5 digits (subject to application
and regulations).
Electronic calibration can be also performed via the m V/V output values of load cells.
WEIGHING FUNCTIONS
Automatic zero tracking, no-motion detection, auto-zero on power-up, zero,
tare (max tare effect = -Max), multiple test functions
FULL SCALE RANGE
The two most significant decades of the digital display are programmable from 1 up to 99 for the
full scale range. Single or dual interval, auto-switching between the different display steps.
MEMORIES
Serial EEPROM for the storage of calibration data
LOAD CELL CONNECTION
NUMBER OF LOAD CELLS
EXCITATION
CONNECTION TECHNIQUE
INTERFACES
SERIAL COM. PORT 1
Up to 10 strain gauge load cells, 1100 Ω each (or 4 load cells 350Ω each)
+5V alternating polarity or +5VDC (set-up selectable), with sense
6-wire technique
RS232C, setup selectable, 2400-9600 baud, 7-8 data bits, no or even parity
Data output selectable (continuous weight output, printer output, print on demand)
POWER SUPPLY
Mains adapter 230VAC 50/60Hz
Internal Pb 6V/3,5AH
ENVIRONMENTAL CONDITIONS / CONSTRUCTION
EMC
According to OIML R76 and EN 45501 requirements
OPERATING TEMPERATURE -10oC to +40oC
STORAGE TEMPERATURE
-10oC to +70oC
HUMIDITY
40% to 90% RH (non condensing)
ENCLOSURE
Plastic, sealed to IP40. Dimensions (in mm): 2600(L)x 170(H)x 110(W)
LEON ENGINEERING (Head Office):
TSOKA 8, THESI XIROPIGADO,
19600 MANDRA, GREECE
Tel: +302107770936, +302107702998
Fax: +302107758925
Email-address: info@leon-engineering.com
http://www.leon-engineering.com
W
Weeiigghhiinngg SSoolluuttiioonnss oouutt ooff tthhiiss W
Woorrlldd
We reserve the right to modify above specifications without prior notice
RETAIL SCALES , INDUSTRIAL WEIGHING, WEIGHING ELECTRONICS, SOFTWARE, PROCESS AUTOMATION AND SYSTEMS , BULK HANDLING AND BAGGING, ENGINEERING PROJECTS