Exceptional performance
The Keysight Technologies, Inc. 11970 Series harmonic mixers are general purpose mixers
employing a dual-diode design to achieve very flat frequency response and low conversion
loss. Each mixer is calibrated across its full band:
11970K* 18 to 26.5 GHz
11970A 26.5 to 40 GHz
11970Q
11970U
33 to 50 GHz
40 to 60 GHz
11970V
11970W
50 to 75 GHz
75 to 110 GHz
This series of mixers has been designed for a local oscillator frequency of 3 to 6.1 GHz.
Accurate absolute amplitude measurements can be made by using the mixer’s conversion
loss calibration chart. The SWR of the waveguide input is typically 2.2:1 to further
minimize measurement uncertainty. The combination of high gain-compression level and
low conversion loss provides the maximum dynamic range for measuring input signals.
* 11970K is excluded from PXA support
03 | Keysight | 11970 Series Harmonic Mixers - Data Sheet
Easy to use
The excellent frequency response and low conversion loss are
achieved without external dc bias or tuning stubs. Since bias and
tuning stubs are not required, manual operation is simplified, and
the complexity of hardware and software for automatic systems
is greatly reduced. The repeatability of amplitude measurements
is also enhanced. The dual-diode design of the mixers further
simplifies measurements by suppressing the odd-order harmonics
by more than 20 dB, which makes identification of the mixing
products easier.
Frequency extension for the Kaysight E4407B,
8560E/EC Series, 8566B, and 71000 Series
and PSA Series spectrum analyzers
The 11970 Series harmonic mixers are fully compatible with the
Keysight E4407B, 8560E/EC Series, 8566B (requires a preamplifier), 71000, and PSA Series spectrum analyzers. Accurate
frequency and amplitude measurements are made directly from
the spectrum analyzer’s display after calibration using the mixer’s
calibration chart.
Frequency extension for the Keysight N9030A
PXA Series signal analyzer
Figure 1. The 11970 Series mixers have separate LO input
and IF output ports
The 11970 Series harmonic mixers (11970K excluded) are also
compatible with the N9030A PXA Series highperformance signal
analyzer. The PXA offers optional external mixing (Option EXM),
enabling it to work with the 11970 Series and other external
mixers for frequency extension. An external diplexer is required
because the PXA external mixing has a single SMA LO/IF port,
whereas the 11970 Series mixers have separate LO and IF ports.
Recommended diplexers can be purchased from Keysight as
N9029AE13, or from OML Inc. as DLP.313B.
Rugged
The rugged Keysight 11970 Series mixers will survive input
levels up to 100 milliwatts (+20 dBm) with no damage to the
mixer diodes. They will withstand shocks up to 30 G’s and the
vibration required by MIL-STD 28800C, Type III, Class 3 tests
Keysight 8560E/EC
Series spectrum
analyzer
Extended
frequency
8560E/EC
Series
IF input
SMA cable
1st LO output
SMA cable
Spectrum analyzer
LO
Keysight 11970 Series
harmonic mixer
Keysight PSA Series spectrum analyzer
Extended frequency PSA Series
IF Input/1st LO output
SMA cable
Mixer
IF diplexer
SMA cable
Keysight E4407B
spectrum analyzer
Extended frequency
E4407B ESA-E Series
IF
Keysight N9030A
PXA Series signal analyzer
Extended frequency PXA Series
LO
SMA barrel
RF input
Keysight 11970 Series
harmonic mixer
04 | Keysight | 11970 Series Harmonic Mixers - Data Sheet
Specifications
Specifications describe the device’s warranted performance over the temperature range 0 to 55° C (except where noted).
IF range
DC to 1300 MHz
LO amplitude range
+14 to +18 dBm1
Calibration accuracy
(with IF of 321.4 MHz or 322.5 MHz)
11970A/Q/U
±2.0 dB with LO amplitude range of +14.5 to +16 dBm;
±3.0 dB with LO amplitude range of +16 to +18 dBm
±2.6 dB with LO amplitude range of +14.5 to +16 dBm;
±3.2 dB with LO amplitude range of +16 to +18 dBm
11970V/W
Nominal RF input SWR
11970A/Q/U
11970V/W
< 2.2:1
< 2.6:1
Bias requirements
None.
Nominal odd-order suppression
11970A/Q/U
11970V/W
> 20 dB
> 15 dB
Maximum CW RF input level
+20 dBm (100 mW)
Maximum peak pulse power
+24 dBm (250 mW) with < 1 μs pulse (average power +20 dBm)
Conversion loss, dB
50
W
45
V
40
35
30
K
25
20
18
Q
A
26.5
33
U
40
50
60
75
Input frequency, GHz
Nominal frequency response & conversion loss
110
Nominal performance, as noted in the following tables, while not warranted, provides information useful in applying the device
11970 Series tested with Keysight PSA spectrum analyzers
Keysight model
number
Frequency
range
(GHz)
LO
harmonic
number
Maximum
conversion
loss (dB)
Nominal spectrum
analyzer noise (dBm)
1 kHz BW
Frequency
response
(dB)
Temperature
Coefficient
28 °C—55 °C
11970K
18 to 26.5
6–
24
–105
±1.9
–3
11970A
26.5 to 40
8–
26
–102
±1.9
–5
11970Q
33 to 50
10–
28
–101
±1.9
–7
11970U
40 to 60
10–
28
–101
±1.9
–7
11970V
50 to 75
14–
40
–92
±2.1
–3
11970W
75 to 110
18–
46
–85
±3.0
–1
1. An LO power of between 14.5 to 16 dBm at the mixer’s LO input is necessary to achieve the given frequency response and spectrum analyzer amplitude accuracy specifications. When LO
power varies between 14 to 18 dBm at the mixer’s LO input, add ±1 dB to the frequency response and spectrum analyzer amplitude accuracy specification.
05 | Keysight | 11970 Series Harmonic Mixers - Data Sheet
11970 Series tested with Keysight PXA spectrum analyzers
Keysight model
number
Frequency
range
(GHz)
LO
harmonic
number1
Maximum
conversion
loss (dB)
Nominal spectrum
analyzer noise (dBm)2
1 kHz BW
Frequency
response
(dB)
Nominal gain
compression
(dBm)
11970A
26.5 to 40
6–/8–
26
–110/–108
±1.9
–5
11970Q
33 to 50
8–/10–
28
–108/–106
±1.9
–7
11970U
40 to 60
10–
28
–106
±1.9
–7
11970V
50 to 75
12–/14–
40
–96/–94
±2.1
–3
11970W
75 to 110
18–
46
–88
±3.0
–1
Keysight model
number
Flange
Weight
X
Y
Z
11970K
UG-595/U
WR-42
0.17 kg
0.36 lb
36 mm
1.4 in
51 mm
2.0 in
90 mm
3.5 in
11970A
UG-599/U
WR-28
0.14 kg
0.32 lb
36 mm
1.4 in
51 mm
2.0 in
71 mm
2.8 in
11970Q
UG-383/U
WR-22
0.14 kg
0.32 lb
36 mm
1.4 in
51 mm
2.0 in
76 mm
3.0 in
11970U
UG-383/U-M
WR-19
0.14 kg
0.32 lb
36 mm
1.4 in
51 mm
2.0 in
76 mm
3.0 in
11970V
UG-385/U
WR-15
0.14 kg
0.32 lb
36 mm
1.4 in
51 mm
2.0 in
76 mm
3.0 in
11970W
UG-387/U
WR-10
0.14 kg
0.32 lb
36 mm
1.4 in
51 mm
2.0 in
76 mm
3.0 in
Ordering Information
11970K*
18 to 26.5 GHz mixer
11970A
26.5 to 40 GHz mixer
11970Q
33 to 50 GHz mixer
11970U
40 to 60 GHz mixer
11970V
50 to 75 GHz mixer
11970W
75 to 110 GHz mixer
Options
11970X-009
Mixer connection kit containing three 1-meter SMA
cables, wrench, and allen driver.
Note: X = K, A, Q, U, V or W
11970X-C01
Improved EMC radiated susceptibility.
Note: X = K, A, Q, U, V or W
N9029A-E13**
Ordering convenience for one OML INC.
LO/IF diplexer with cables and adapter
* Not compatible with N9030A PXA
** Required if the 11970 mixer is used with the Keysight PXA
Warranty and Service
Standard warranty for 11970 mixers is 12 months
Standard warranty for N9029A-E13 diplexer is 3 months, provided by OML, Inc.
1. When used with 11970 Series mixer in A-, Q-, or V-band, the PXA’s LO harmonics are automatically switched between two different numbers as listed to optimize
conversion loss.
2. If the LO harmonics are switched, the noise levels for the signal analyzer/mixer combination will change, corresponding to the different LO harmonic numbers.
06 | Keysight | 11970 Series Harmonic Mixers - Data Sheet
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of
the PCI Industrial Computer Manufacturers Group.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com/find/externalmixers
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
0800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-07-10-14)
This information is subject to change without notice.
© Keysight Technologies, 2013 - 2014
Published in USA, August 3, 2014
5968-1445E
www.keysight.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising