Intech Product Guide 2011

Intech Product Guide 2011
TABLE OF CONTENTS
New Release Products from Intech Instruments!
Page
3
Transmitters: Loop powered and 4 wire powered
NEW XU Series - Universal Input Transmitters: Temperature, mA, mV & V, Potentiometer
4
LP Series - 2 wire Loop Powered Transmitters: Temperature, DC, Bridge, Resistance, Potentiometer, AC current
5
PI Series - Plug-in Transmitters: Temperature, DC, Frequency, Bridge, Resistance, Potentiometer, Set point alarm, Maths
6
XI 4~20mA DC Isolator Series: XI-P 4~20mA Input Powered Isolators and XI-L 4~20mA Loop Powered Isolators
7
XJ22, Dual Transmitter: 2 Wire Universal Input, Loop Powered Dual Transmitter
7
LPI-F 2 wire Loop Powered Frequency Transmitter: Flow meters and other devices with low level output
8
Transmitters: Frequency, Differential pressure, pH, DO2, Humidity, Light.
TW Series Frequency Transmitters: 4~20mA to Frequency for direct conversion into a PLC digital input. Frequency to frequency divider
9
LPN Series - Differential Pressure Transmitters: 7 ranges from mm WG to KPa/psi
11
LPI Series - Electrochemical Transmitters: pH, DO2
11
IN-HWD Humidity Indicator Transmitter: Humidity wet & dry tank.
12
LPN-H Humidity & Temperature Transmitters: Two 2 wire Loop Powered Transmitters
12
TWN-LUX: Light intensity Transmitter
13
Converters, Generators, Switches, Filters, Calibrators, Instrument Power
Supplies
Signal Transmitters / Controllers: Prescaler. Current loop limiter. Digital Isolator. Valve controllers. Line filter. Pulse amplifier.
10
IN-GEN, LPN-OVP: Signal Generator, Over Voltage protection.
13
PSW Instrument Power Supplies: DC Output Switch Mode Power Supplies.
14
D to A converter TW-DA and 2100-RL2: (2 channel digital input to 2 relay output – compatible with 2100-A16 digital outputs)
15
NEW IN Series - Process Indicators
IN-P, Multifunction Indicator
IN-R, IN-RT, IN-RTB: Large Display Tachometer, Flow Rate with Totalizer, Flow Rate and Batching Controller.
LPI-LCD-5, Panel Mount Indicator: Loop powered
16
17
17
Intech Micro Multiplexers and I/O Remote Stations- 2100 Series Multiplexers
2100-M standard multiplexers: Pt100, mA, mV & V;
IN-ICM: Clock and reset isolators
18
2100-A16 configured as an Intelligent multiplexer: Pt100 or Pt1000, TC, mA, mV & V. Each input channel individually configurable
19
2100-AO configured as a PLC Analogue output multiplexer
20
NEW 2300 Series - Stand-alone Analogue and Digital Input / Output Remote Stations
22
2100-D Digital input & relay output Remote Station
24
2100-R2 Relay output expansion: Relay output expansion for the 2100-A16 or 2100-A4.
2100-AO Analogue and digital I/O Remote Station
2100-A16 Remote Station: Pt100 or Pt1000, Thermocouple, mA, mV & V. Each input channel individually configurable plus digital I/O & AO
24
25
26
2100-A4 Remote Station: Pt100, Thermocouple, Thermistor, mA, mV & V. Each input channel individually configurable plus digital I/O & AO
27
Serial and Ethernet Converters
2100-IS: Isolated and 2100-NS Non Isolated: RS232 to 422/485 converters.
21
USB485: USB to RS485 Non Isolated converter.
21
2100-4S: Isolated RS422 to 485 converter.
21
2100-NET: Ethernet to RS232, 422 & 485 converter.
21
Mini Packs PC Recorder Kits – includes MicroScan Recorder Lite plus Intech Micro I/O
Remote Station(s)
Mini Pack 8: 8 channel Recorder - Voltage/Current/Thermocouple/RTD/Multi
28
Mini Pack 16: 16 channel Recorder - Pt100 or Pt1000, Tc, mA, mV & V, digital inputs plus alarm outputs and analogue retransmission
28
Mini Pack 32: 32 channel Recorder - Pt100 or Pt1000, Tc, mA, mV & V, digital inputs plus alarm outputs and analogue retransmissions
28
Schematic showing connection of 2100 series plus controllers to PC and PLC
29
MicroScan Recorder and SCADA Software
MicroScan Recorder features.
30
MicroScan Mimic features: Mimics plus support for controllers, PLC’s, Network, and MicroScan Tool Box special function generator.
31
MicroScan listed with all options: Version 5.
MA5 MicroScan Mobile Alarming 5 software: Alarms & queries transmitted to: mobile phone text messages, email, factory PA.
32
33
Shimaden Lite: Free software for Shimaden controllers and indicators with comms
33
Tel-Link Radio Modems: Enables MicroScan wireless data links
34
ZigBee: New Technology for MicroScan wireless data links
35
Mini Data Loggers and Logger Software
HR series: RTD Pt100/Pt500/Pt1000, Thermocouple, Humidity, pH, Water level, mA, mV & V, single and multi channel.
36
Data loggers & OmniLog: Data management software for TruTrack data loggers.
37
GP-MC: Multi purpose data logger.
38
LCD series: Handheld temperature data logger with liquid crystal display; Humidity, Thermocouple, RTD Pt100/Pt500/Pt1000 and Pressure.
39
NEW Environmental Monitoring Systems: Small & Medium Weather Sensor Transmitters: 4~20mA output signals.
40
pH Probes plus pH and DO2 transmitters
42
Intech Instruments Ltd - Conditions of Sale
44
2
W!
E
N
Latest Product Releases from Intech Instruments!
W!
E
N
XU Universal Input Transmitters





Programmable with simple software via USB connection.
No power required during programming.
No calibration required for range changes.
Fully isolating 3750Vac.
High accuracy 0.1%.
For more information please see page 4 >>
Process Indicators
The IN Series Process Indicators are a new addition to the Intech product range.
Each model features:

Simple setup and calibration

On screen step by step instructions

5 buttons for easy operator interface

Option to add up to 6 relay outputs

Analogue output retransmission option

Serial RS485/RS232 port option with Modbus RTU (excluding IN-R)

Wide range of Power Supply options
For more information please refer to page 16 and 17 >>
Intech Micro 2300 Series I/O Remote Stations
The Intech Micro 2300 series is a system of modular I/O Remote Stations, that add an even
lower cost option to Intech’s already extensive intelligent I/O Remote Station family, which
connect automatically to the Intech MicroScan V5 logging plus SCADA software package.
The 2300 series I/O stations are made up of stand-alone Digital and Analogue Input/Output
stations. Communications between the computer running MicroScan V5 and the 2300 series
stations is RS485 (1 pair cable) multi drop as standard with an option for TCP.
All the models use 24Vdc power supply.
For more information please refer to pages 22, 23 and 28 >>
HR Series loggers updated
New release (mark 4) of the HR Series data loggers with user
replaceable battery and HUGE storage capacity.
(Excludes WT-HR)
For more information please refer to pages 36 and 37 >>
Environmental Monitoring Systems / 4~20mA Weather Sensor
Transmitters
Intech now have available a modular range of environmental monitoring systems, as well as
weather sensor transmitters with industrial standard 4~20mA output signals available in both
individual and fully mounted systems.
For more information please refer to pages 40 and 41 >>
3
XU UNIVERSAL INPUT TRANSMITTERS
XU2 (2 Wire) Universal Input
INTECH INSTRUMENTS
W!
E
N
• Programmable via USB (requires XU-USB key).
• No power supply or calibration required during
programming.
• 2 wire 4~20mA output. Loop powered.
• 3750Vac isolation.
MODEL
XU2
•
•
•
•
•
High accuracy 0.1%.
Reverse Polarity Protected.
Heartbeat Status LED.
Compact DIN Rail Mount Enclosure.
Available Standard or Special
Calibration.
DESCRIPTION
Single Universal Input Transmitter
Input types: mV, V, & mA.
RTD Pt100 / Pt1000.
Thermocouple (T/C).
Potentiometer.
Output:
2 wire 4~20mA.
XU2
For Ordering Code &
Specification Refer Web:
www.intech.co.nz/xu2
XU-USB USB Programming Key
XU2HI & XU2HN (2 Wire) Head Mount
•
•
•
•
•
•
Single Temperature (RTD/Thermocouple) Input In-Head Transmitter
Programmable via USB (requires XU-USB key).
No power supply or calibration required during programming.
2 wire 4~20mA output. Loop powered.
High accuracy 0.1%.
Reverse Polarity Protected.
MODEL
XU2HI
XU2HI & XU2HN
DESCRIPTION
Single Temperature Input Transmitter
For mounting in a probe head. Isolating.
Isolation:
3750Vac.
Heartbeat Status LED.
Input types: RTD Pt100 / Pt1000.
Thermocouple (T/C).
Output:
2 wire 4~20mA.
Single Temperature Input Transmitter
For mounting in a probe head. Non-isolating.
Input types: RTD Pt100 / Pt1000.
Thermocouple (T/C).*
Output:
2 wire 4~20mA.
XU2HN
For Ordering Code &
Specification Refer Web:
www.intech.co.nz/xu2h
www.intech.co.nz/xu2h
XU-USB USB Programming Key
Note: Thermocouple I/P is not recommended on Non-Isolated Transmitters* unless care is taken with system design.
Note:
The same XU-USB Programming Key
can be used to program any of the XU
Series Transmitters - just change the
included adaptor plug for DIN or In-head!
XU4 (4 Wire) Universal Input
•
•
•
•
•
•
•
•
•
Programmable via USB (requires XU-USB key).
No power supply or calibration required during programming.
3750Vac isolation.
High accuracy 0.1%.
Reverse Polarity Protected.
Heartbeat Status LED.
Compact DIN Rail Mount Enclosure.
Available Standard or Special Calibration.
Universal ac/dc Power Supply; 20~265Vac and 21~265Vdc.
MODEL
XU4
XU4
DESCRIPTION
Single Universal Input Transmitter
Input types: mV, V, & mA.
RTD Pt100 / Pt1000.
Thermocouple (T/C).
Potentiometer.
Output types: Current - e.g. 4~20mA.
Voltage - e.g. 0~10V
For Ordering Code &
Specification Refer Web:
www.intech.co.nz/xu4
XU-USB USB Programming Key
Note: The XJ22 Dual Universal Input Transmitter is also available. Please find more information on page 7 >>
4
LOOP POWERED TRANSMITTERS
•
•
•
•
•
INTECH INSTRUMENTS
LP - Series ( 2 wire)
Output, 4~20mA loop powered.
2 kV isolation for LPI series.
0.1% accuracy.
40~200mV output test signal.
LED indication of loop current.
LPN-R-H
LPN-R-H
MODEL
DESCRIPTION
For Ordering Code &
Specification Refer Web Page:
LPI-D-F
DC to DC isolating signal transmitter.
Fixed input range, either 0~10V or 4~20mA.
www.intech.co.nz/lpi-d
LPI-D-P
DC to DC isolating signal transmitter.
Programmable input ranges, from 0~10mV to 150V
and, from 0~200uA to 50mA.
www.intech.co.nz/lpi-d
LPI-B
Bridge to DC isolating signal transmitter.
Programmable input ranges from 0~1mV to 800mV.
www.intech.co.nz/lpi-b
Bridge
LPI-K
Resistance to DC isolating transmitter.
Programmable input ranges from 0~10 ohms to 2k ohms.
www.intech.co.nz/lpi-k
Resistance
LPI-P
Potentiometer to DC isolating transmitter.
Programmable input span from 0~10% to 0~100%.
Elevated zero or suppressed span.
Resistance range from 0~1000 ohm to 0~1 Meg ohm.
www.intech.co.nz/lpi-p
Potentiometer to DC non-isolating transmitter.
Programmable input span from 0~20% to 0~100%.
Resistance range from 0~1000 ohm to 0~1 Meg ohm.
www.intech.co.nz/lpn-p
Differential RTD to DC isolating transmitter.
Programmable ranges from -200~0~20 to 500°C/F.
Standard input Pt100, others by request.
www.intech.co.nz/lpi-n
RTD to DC isolating transmitter.
Pt100, others by request.
Fixed ranges from -200~0~20 to 500°C/F.
www.intech.co.nz/lpi-r
RTD to DC isolating transmitter.
Pt100, others by request.
Programmable ranges from -200~0~20 to 500°C/F.
www.intech.co.nz/lpi-r
LPN-P
LPI-N
LPI-R-F
LPI-R-P
LPN-R-X1
LPN-R-X2
LPN-R-H
LPI-T-F
LPI-T-P
LPI-CT-X1
LPI-CT-X2
RTD to DC non-isolating transmitter.
Programmable ranges from -100~0~30 to 600°C/F.
Standard input Pt100, others by request.
Single RTD to DC non-isolating transmitter.
Dual RTD to DC non-isolating transmitters.
RTD (Pt100) to DC non-isolating transmitter.
For mounting in a probe head.
Programmable ranges from -100~0~30 to 600°C/F. Pt100 input.
Double mounting screw holes are at 40mm or 33mm centres.
Option for DIN Rail Mount Foot.
DC signal
Potentiometer
RTD
www.intech.co.nz/lpn-r
www.intech.co.nz/lpn-r-h
Thermocouple to DC isolating transmitter.
Fixed ranges from -100~0~200 to 1700°C/F.
Available for type K, J, N, R, S, T.
www.intech.co.nz/lpi-t
Thermocouple to DC isolating transmitter.
Programmable ranges from -100~0~ 200 to 1700°C/F.
Available for type K, J, N, R, S, T.
www.intech.co.nz/lpi-t
AC current to DC isolating transmitter.
Selectable input, 0~1 amp ac or 0~5 amp ac.
Special ranges on request.
Single LPI-CT transmitter.
Dual LPI-CT transmitters.
www.intech.co.nz/lpi-ct
Thermocouple
AC current
5
PLUG-IN TRANSMITTERS
INTECH INSTRUMENTS
PI - Series ( 4 wire)
•
•
•
•
•
•
•
Input and output ranges are field programmable.
Bi-polar - Input and output signals.
1.6kV isolation.
0.1% accuracy.
Plug-in-DIN rail mount base.
Special calibration available.
Power supply;
85~264Vac/dc or 22~85Vac/dc selectable;
10~28Vac/dc optional.
MODEL
DESCRIPTION
For Ordering Code &
Specification Refer Web Page:
PI-D
DC to DC isolating signal transmitter.
Programmable input ranges from 0~10mV to 150V, 0~200uA to 50mA.
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
On board 20Vdc power supply for primary transmitter.
www.intech.co.nz/pi-d
DC signal
Frequency to DC isolating signal transmitter.
Programmable input ranges from 0~0.4 Hz to 40 kHz.
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
On board 12Vdc 50mA power supply for primary signal.
www.intech.co.nz/pi-f
Frequency
Bridge to DC isolating signal transmitter.
Programmable input ranges from 0~1mV to 1000mV
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
On board precision 10 volt 30mA power supply for bridge excitation.
www.intech.co.nz/pi-b
Bridge
Maths function, DC to DC isolating transmitter with 3 inputs.
Programmable V and mA input ranges.
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
32 predetermined programmable math functions.
120 point user defined curve fitting.
www.intech.co.nz/pi-m
PI-F
PI-B
PI-M
PI-RAC
PI-K
PI-P
PI-N
PI-R
PI-T
PI-S
6
RS232 adapter cable for connecting the PI-M to a computer.
Uses Windows Notepad or Excel in conjunction with Windows Hyper
Terminal.
Maths
function
www.intech.co.nz/pi-rac
Resistance to DC isolating transmitter.
Programmable input ranges from 0~10 ohms to 20k ohms.
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
www.intech.co.nz/pi-k
Resistance
Potentiometer to DC isolating transmitter.
Resistance range from 0~200 ohms to 0~1M ohms.
Programmable input span from 0~10% to 0~100%.
Elevated zero or suppressed span available.
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
www.intech.co.nz/pi-p
Potentiometer
Differential RTD to DC isolating transmitter.
Programmable ranges from -200~0~20 to 500°C/F.
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
Standard input Pt100, others by request.
www.intech.co.nz/pi-n
Differential
RTD
RTD to DC isolating transmitter.
Programmable ranges from -200~0~20 to 500°C/F.
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
Standard input Pt100, others by request.
www.intech.co.nz/pi-r
RTD
Thermocouple to DC isolating transmitter.
Programmable ranges from -100~0~200 to 1700°C/F .
Programmable output ranges from 0~500mV to 12V, 0~1mA to 20mA.
Available for type K, J, N, R, S, T.
www.intech.co.nz/pi-t
Thermocouple
Set point alarm unit. Two set points, two relay outputs.
Programmable input ranges from 0~5V to 10V, 0~10mA to 50mA.
The action of the two alarm relays is selectable, high, low, window &
differential.
Selectable N/O-N/C contacts. Adjustable time delay of 0.2~30 sec.
www.intech.co.nz/pi-s
Set point
alarm
XI-L Loop Powered Isolators
•
•
•
•
•
•
•
•
Isolating 4~20mA Input to 4~20mA Output Transmitter.
Input to Output Isolation 1kV.
High Accuracy 0.1%.
Loop Powered.
Reverse Polarity Protected.
Compact DIN Rail Mount Enclosure.
Available with 1, 2 or 4 transmitters per Enclosure.
Easy to Install.
MODEL
DESCRIPTION
XI-L1
One Isolator
XI-L2
Dual Isolators
XI-L4
Quad Isolators
XI-L1
XI-L4
XI-L2
For Ordering Code &
Specification Refer Web Page:
INTECH INSTRUMENTS
XI 4~20mA ISOLATOR SERIES
www.intech.co.nz/xi-l
XI-P Input Powered Isolators
•
•
•
•
•
•
•
•
•
•
4~20mA Input Powered to 4~20mA Output Isolation Transmitter.
Ideal for isolating a typical 4~20mA loop.
Also good for Line Filtering at the Receive end of Line.
No Power Supply Needed - Input Powers Output.
Input to Output Isolation 1kV.
High Accuracy.
Reverse Polarity Protected.
Compact DIN Rail Mount Enclosure.
Available with 1, 2 or 4 transmitters per Enclosure.
Easy to Install.
MODEL
DESCRIPTION
XI-P1
One Isolator
XI-P2
Dual Isolators
XI-P4
Quad Isolators
XI-P1
XI-P2
XI-P4
For Ordering Code &
Specification Refer Web Page:
www.intech.co.nz/xi-p
XJ22 DUAL TRANSMITTER
XJ22 (2 Wire) Universal Input
• Field Programmable Bi-Polar Input Ranges.
•
•
•
•
•
•
•
2 wire 4~20mA dual outputs. Loop powered.
2.0 kV isolation.
0.1% accuracy.
Reverse Polarity Protected.
LED indication of loop current.
Compact DIN Rail Mount Enclosure.
Available Standard or Special Calibration.
MODEL
XJ22
DESCRIPTION
Dual Transmitter
Input types; mV, V, & mA.
RTD Pt100.
Differential RTD.
Thermocouple (T/C).
Bridge/Strainguage.
Potentiometer.
Resistance.
Outputs;
2 wire 4~20mA.
For Ordering Code &
Specification Refer Web Page:
www.intech.co.nz/xj22
XJ22
Also see our XU Series USB
Programmable Universal Input
Transmitters on Page 4 <<
7
FREQUENCY TO DC
LOOP POWERED TRANSMITTERS
INTECH INSTRUMENTS
LPI-F ( 2 wire)
•
•
•
•
•
Output, 4~20mA loop powered.
2kV isolation.
0.1% accuracy.
40~200mV output test signal.
LED indication of loop current.
Frequency to DC isolating signal transmitter.
Programmable ranges from 0~15Hz to 0~10kHz.
Input,
2 wire.
Sine, Square, Pulse.
Uni-polar or bi-polar.
Minimum input signal;
Maximum input signal;
Output,
(Signals <2Vpp Bipolar only).
10mVpp @ 100Hz. 100mVpp @ 1kHz. 1Vpp @ 10kHz.
100V pp. (100Hz max for contact closure)
2 wire, 4~20mA loop powered.
800 ohms at 24Vdc.
MODEL
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
LPI-F-D
DIN rail mount unit.
LPI-F-E
Field mount enclosure.
www.intech.co.nz/lpi-f
Typical connection for LPI-F / Isolating.
Frequency input
LPI-F
Power supply
4~20mA output
Field transmitter with a self generating
pulse output;
E.g. Trimec DP490 flow meter
Controller,
Scada input,
PLC input.
Typical connection for LPI-F / Isolating
Power supply
Pulsed
Reed switch
Solid state relay
Proximity switch, NPN
Proximity switch, PNP
8
Hz to 4~20mA
LPI-F
Power supply
4~20mA output
Controller,
Scada input,
PLC input,
MODEL
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
TWI-FO
Isolating DC to frequency interface.
Converts a 4~20mA signal to a frequency for direct
conversion into a PLC digital input.
LED indication of Hz output.
1.6kV isolation.
Power supply;
11~28Vdc.
Standard input;
4~20mA, others by request.
Standard output;
10~1010 Hz, others by request.
TWN-FO
Non-isolating DC to frequency interface.
As above.
4~20mA to Hz
Converter
www.intech.co.nz/tw-fo
INTECH INSTRUMENTS
DC TO FREQUENCY TRANSMITTERS
TW - Series
Typical connection for TWN-FO / Non-Isolating
TWN-FO
4~20mA
PLC
24Vdc
Digital input
0Vdc
Pulsed output
Two wire transmitter
Typical connection for TWI-FO / Isolating
Power supply
4~20mA
TWI-FO
PLC
24Vdc
Digital input
0Vdc
Pulsed output
Two or three wire transmitter
FREQUENCY TO FREQUENCY TRANSMITTERS
TW - Series
MODEL
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
TWI-FF
Isolating frequency input, divided, to open collector
frequency output interface.
LED indication of Hz output.
1.6kV isolation.
Power supply; 11~28Vdc.
Division factor; 2 to 4096 in 12 binary steps.
2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2028, 4096.
Input;
5~30Vdc, square wave. (max 100kHz)
www.intech.co.nz/tw-ff
Output;
Open collector 30Vdc, 100mA Maximum.
Square wave, (max 5kHz)
50:50 mark space ratio.
TWN-FF
Non-isolating frequency input, divided, to sink / source
100mA @ 24Vdc frequency output interface.
As above.
Hz to Hz
Divider
Typical connection for TWN-FF / Non-Isolating
Pulsed input
TWN-FF
PLC
24Vdc
Digital input
0Vdc
Divided pulsed output
Field transmitter with a solid state output;
E.g.
Mag flow meter
Trimec DP490 flow meter
Proximity switch
Power supply
Typical connection for TWI-FF / Isolating
Pulsed input
TWI-FF
Divided pulsed output
4K7
PLC
24Vdc
Digital input
0Vdc
Field transmitter with a solid state output;
E.g.
Mag flow meter
Trimec DP490 flow meter
Proximity switch
9
SIGNAL TRANSMITTERS / CONTROLLERS
INTECH INSTRUMENTS
MODEL
DESCRIPTION
IN-588A
Prescaler.
Primarily designed for use with flow transducers or other
devices with frequency output signals.
Current Use;
50mA Typical, regardless of P/S voltage.
(90mA if Relay Output is Used).
Prescaling Range; Divides Input Signal From 1 to 10,000,000.
Temperature Range;
0~50°C. (Storage Temp -20~80°C).
Operating Humidity;
5~85% RH Max. Non-condensing.
IN-CLL
Current loop limiter.
This unit is designed to limit the current that can flow in a
0/4~20mA loop.
Power supply;
Loop powered.
Loop volts;
3~32Vdc.
Volt drop over unit;
3 volts.
Adjustable range;
1~22mA.
For Ordering Code &
Specification Refer Web Page:
www.intech.co.nz/in-588a
www.intech.co.nz/in-cll
www.intech.co.nz/in-oid
IN-OID
Optical isolator for digital signals.
Input;
5Vdc, 12Vdc, 15Vdc, 24Vdc, 110Vdc, 24Vac.
Output;
Open collector 30Vdc, 100mA maximum.
Isolation;
3kV.
IN-VCC
Current controller for control valves.
Power supply;
24Vac, 16VA.
Valves;
Sporlan or similar.
Input;
4~20mA.
Output;
0~420mA.
www.intech.co.nz/in-vcc
www.intech.co.nz/phasecut
Phase chopped voltage valve controller.
Power supply;
24Vac, 50VA.
Phasecut Valves;
Staefa or similar.
Input;
4~20mA.
Output;
0~20V phase chopped.
www.intech.co.nz/in-lf
IN-LF
Line filter.
Voltage;
Output;
210~250Vac. (Others by request).
Max. load = 3 amps.
www.intech.co.nz/tw-ffa
TW-FFA
10
Flow pulse amplifier. (was IN-FFA).
Power supply; 5~32Vdc.
Input;
Flow meter impeller or mV; ac or dc frequency.
Output;
Square wave, 200mA / 24Vdc. 10kHz max.
INTECH INSTRUMENTS
PRESSURE TRANSMITTERS
LPN - Series
• 4~20mA loop powered.
• Temperature compensation.
• IP67 enclosure.
MODEL
DESCRIPTION
LPN-DP-100mm
Differential pressure transmitter.
Differential range within ±20 to ±125 mm WG
100mm
LPN-DP-250mm
Differential pressure transmitter.
Differential range within ±100 to ±250 mm WG
250mm
LPN-DP-1000mm
Differential pressure transmitter.
Differential range within ±250 to ±1000 mm WG
1000mm
LPN-DP-40kPa
Differential pressure transmitter.
Differential range within ±10 to ±40 kPa.
40kPa
LPN-DP-100kPa
Differential pressure transmitter.
Differential range within ±40 to ±100 kPa.
100kPa
LPN-DP-3/15 psi
Pressure transmitter.
Range, 3 to 15 PSI.
3/15 psi
LPN-DP-Bar
Absolute pressure transmitter.
(atmospheric).
Range, 900 to 1100 mbar absolute.
www.intech.co.nz/lpn-dp
Bar
ELECTROCHEMICAL TRANSMITTERS
LPI - Series
• 4~20mA loop powered.
• LCD display.
• 2kV isolation.
MODEL
•
•
•
•
0.1% accuracy.
40~200mV output test signal.
LED indication of loop current.
IP67 enclosure.
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
LPI-pH
LPI-DO2
pH voltage to DC isolating transmitter with LCD display.
pH milli volt input and Pt100 temperature compensation.
Slope and offset adjustments for on-site calibration.
www.intech.co.nz/lpi-ph
DO2 voltage to DC isolating transmitter with LCD display.
0~30 milli volt input.
Range, 0~8.26 ppm oxygen.
Slope and offset adjustments for on-site calibration.
www.intech.co.nz/lpi-do2
For pH probes available for use with the LPI-pH, refer to pages 42 and 43 >>
0
pH
0
mV at 25°C
+413
ACID
H+
1
2
3
NEUTRAL
7
4
5
6
7
0
ALKALINE
OH-
8
9
10
11
14
12
13
14
-413
11
HUMIDITY INDICATOR / TRANSMITTER
IN-HWD
INTECH INSTRUMENTS
W!
NE
• Humidity and Temperature Indicator/Transmitter.
• This unit is used with a wet and dry sensor system (e.g. WDT-DW).
• The IN-HWD uses a microprocessor with formulae and look-up tables to obtain
better than 1% accuracy for relative humidity over the range of 0~100°C.
• Note: The IN-HWD (rev 2) replaces both the 2100-A4-HWD and the older IN-HWD.
MODEL
DESCRIPTION
For Ordering Code & Specification:
IN-HWD
Input, 1x wet bulb and 1x dry bulb.
Standard;
RTD Pt100, 3 wire DIN (0~100ºC).
Output, 1x humidity and 1x temperature.
2 channels: 4~20mA.
Resolution; 0.025% Full scale. 12 bit.
Indicator;
Dual LED screens for humidity and temperature.
Alarm/Control; 4x 5A Relay Outputs.
Standard Power Supply; 85~265Vac / 95~370Vdc.
S
Serial Port RS485 or RS232 (specify). Includes Modbus RTU.
www.intech.co.nz/in-hwd
Low Voltage Power Supply; 15~48Vac / 10~72Vdc.
LV
HUMIDITY WET AND DRY TANK
WDT-DW
•
•
•
•
MODEL
Humidity tank with wet and dry sensors.
For the measurement of relative humidity, RH%.
Commonly used with the IN-HWD Humidity Indicator / Transmitter.
Constructed of 316 stainless steel.
DESCRIPTION
WDT-DW
WDT-WICK
For Ordering Code & Specification:
Sensors;
RTD, Pt100, Band 5. 4.8ø x 150. Others by request.
Fill port;
1/8”BSP nipple.
Overflow port; 1/8”BSP nipple.
Mount;
Wall or duct mount.
Cable;
4 metres.
www.intech.co.nz/wdt-dw
Spare wick for wet bulb sensor.
HUMIDITY TRANSMITTERS
LPN-H-D
LPN-H Transmitters
•
•
•
•
Dual output, 4~20mA loop powered.
Outputs, %RH and Temp.
Monolithic IC humidity sensor.
Pt100 RTD sensor.
MODEL
LPN-H-Flange
DESCRIPTION
LPN-H-D
For Ordering Code & Specification:
Humidity and temperature transmitter, 220mm Duct Mount.
Dual output, each loop powered.
Temperature;
4~20mA = 0~100°C.
Humidity;
4~20mA = 0~100% RH.
www.intech.co.nz/lpn-h
LPN-H-Flange Optional 100mm flange for LPN-H-D
LPN-H-W
Humidity and temperature transmitter, Wall Model.
Dual output, each loop powered.
Temperature;
4~20mA = 0~100°C.
Humidity;
4~20mA = 0~100% RH.
Calibration canisters for LPN-H.
LPN-H-84
LPN-H-75
LPN-H-43
LPN-H-33
LPN-H-8
LPN-H-W
Calibration canister with 84% RH salt solution.
Calibration canister with 75% RH salt solution.
Calibration canister with 43% RH salt solution.
Calibration canister with 33% RH salt solution.
Calibration canister with 8% RH salt solution.
Calibration system for LPN-H series Humidity sensors.
The LPN-H-Ref system is designed to allow in situ calibration
of LPN-H-W and LPN-H-D humidity Transmitters.
The LPN-H-Ref system consists of corrosion resistant stainless steel canisters containing humidity regulating salt solutions that replace the black protective filter on the sensor.
Important Note:
1. It is essential that the humidity sensor is mounted vertically with the filter at the bottom to prevent spillage.
12
IN-GEN
• Multifunction generator.
• Outputs instrument signals.
• Use with your own multimeter.
MODEL
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
www.intech.co.nz/in-gen
IN-GEN
Power supply;
50~150 ohms;
0~20mA;
0~100mV;
0~8 volts;
9 volt battery.
Simulates Pt100, (-100~100°C)
Simulates 0~20mA. max 320 ohms.
Simulates thermocouple signals.
Simulates 0~8 volts.
INTECH INSTRUMENTS
HAND HELD SIGNAL GENERATOR
OVER VOLTAGE PROTECTION UNIT
LPN-OVP
• Over Voltage protection unit for instrument signals.
• Used extensively for lightning protection.
MODEL
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
www.intech.co.nz/lpn-ovp
Leakage Current;
10μA @ 24Vdc.
Transient cut-off voltage;
32V standard
(Other ranges available on request).
Added line resistance;
28 ohms for the loop.
LPN-OVP-D
LPN-OVP-E
LPN-OVP-G
Din rail mount.
IP67 enclosure, c/w glands.
Spare set of 3 discharge tubes.
LIGHT INTENSITY TRANSMITTER
TWN-LUX
MODEL
DESCRIPTION
For Ordering Code &
Specification Refer Web Page:
www.intech.co.nz/twn-lux
TWN-LUX
Light intensity transmitter.
Power supply; 12~24Vdc.
Range;
0~1000 lux, adjustable to 0~10 lux.
Dual outputs; 1 x 4~20mA and 1 x 0~10Vdc.
13
INSTRUMENT POWER SUPPLIES
PSW
INTECH INSTRUMENTS
The PSW-2 is an isolated switch mode power supply that can supply a wide range of DC output voltages, from
5V to 30V, up to 200mA continuously, and operates over a wide range of input voltages. Due to recent
advancements in Switch Mode Power Supply technology, special techniques have been developed that make
the PSW-2 both very low noise (typically less than 1mV) and high precision.
Both line and load regulation is better than 0.1% over all conditions. (Within specified ranges.) These attributes
make the PSW-2 better than most comparable linear power supplies, while adding features such as DC input
and voltage step-up capability, eg; 12Vdc input can be stepped up to 24Vdc output. (PSW-2-L version).
•
•
•
•
•
•
•
•
•
•
PSW-2
MODEL
PSW-2
PSW-2-L
Output Adjustable from 5V to 30V.
Output Current of 200mA.
Low Noise.
Precision Regulation.
Isolated Output Floats Close to Earth Potential.
Short Circuit Tolerant.
High Accuracy 0.1%.
Universal ac/dc Power Supply.
Compact DIN Rail Mount Enclosure.
Available Standard or Special Calibration.
DESCRIPTION
Output Voltages;
5, 8, 9, 10, 12, 15, 24, 30, Special.
Input Power Supplies;
High (100~264Vac/dc).
Medium (23~90Vdc).
For Ordering code & Specifications
Refer Web Page:
www.intech.co.nz/psw-2
12~28Vac / 10~30Vdc input.
The PSW-10 is an isolated switch mode power supply that can supply a wide range of DC output voltages, from
5V to 30V, up to 1A continuously, and operates over a range of input voltages. Due to recent advancements in
Switch Mode Power Supply technology, special techniques have been developed that make the PSW-10 both
very low noise (typically less than 1mV) and high precision.
Both line and load regulation is better than 0.1% over all conditions. (Within specified ranges.) These attributes
make the PSW-10 better than most comparable linear power supplies.
•
•
•
•
•
•
•
•
•
•
PSW-10
MODEL
PSW-10
14
Output Adjustable from 5V to 30V.
Output Current of 1A.
Low Noise.
Precision Regulation.
Isolated Output Floats Close to Earth Potential.
Short Circuit Tolerant.
High Accuracy 0.1%.
Universal ac/dc Power Supply.
Compact DIN Rail Mount Enclosure.
Available Standard or Special Calibration.
DESCRIPTION
Output Voltages;
5, 8, 9, 10, 12, 15, 24, 30, Special.
Input Power Supply;
100~264Vac/dc.
For Ordering code & Specifications
Refer Web Page:
www.intech.co.nz/psw-10
DIGITAL INTERFACE UNIT
• Boosts current capacity for equipment with only transistor or Reed relay outputs.
• Two isolated relay outputs, each with change-over contacts.
• DIN rail mount.
Ideal to boost the output capacity of the 2100-A16 to 250 volts.
MODEL
2100-RL2
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
Digital interface unit.
Power supply; 24Vdc.
Input;
Two solid state or relay contacts.
Output;
Two relays, each with change-over contacts.
250Vac.
2 amps.
30Vac.
2 amps.
Typical connection for 2100-RL2
www.intech.co.nz/2100-rl2
INTECH INSTRUMENTS
2100-RL2
Two digital inputs
Solid-state or Reed relay.
Two relay outputs
c/o contacts.
Power supply 24Vdc
Controller.
PLC input.
Computer input.
Alarms.
2100-RL2
DIGITAL TO ANALOGUE CONVERTER
TW-DA
• Isolated digital inputs to analogue output in binary steps.
• Bi-polar digital inputs.
• DIN rail mount.
Ideal for a digital PLC that requires a 4~20mA output.
For Ordering Code &
Specification Refer Web Page:
MODEL
DESCRIPTION
TW-DA
Isolated digital to analogue converter
Power supply; 24Vdc.
Input;
Solid state or relay contacts.
Selectable to any of the following;
2 digital inputs gives 4 output steps. 33.3% per step.
3 digital inputs gives 8 output steps. 14.3% per step.
4 digital inputs gives 16 output steps. 6.67% per step.
5 digital inputs gives 32 output steps. 3.22% per step.
6 digital inputs gives 64 output steps. 1.59% per step.
Input voltage;
6~30Vdc.
The same 24 volt power supply may be used to power both the
input and the output, but this would void the input/output isolation.
Code;
Binary. N/O = 0. N/C = 1.
Output;
Selectable by jumpers to any of the following,
4~20mA, 0-20mA, 2-10Vdc, 0-10Vdc.
Typical connection for TW-DA
Using 4 digital inputs
Non–isolating mode.
Digital outputs from;
Controller,
PLC, Etc.
www.intech.co.nz/tw-da
TW-DA
4~20mA output
Controller
PLC input
VSD unit
Power supply 24Vdc
15
MULTIFUNCTION INDICATOR
INTECH INSTRUMENTS
W!
E
N
IN-P
The IN-P is a Multifunctional Indicator which not only interfaces smoothly with a wide range of PLC and
monitoring systems, but also as a stand alone unit for single and multi input Indication - Alarm - Control.
Features;
• Simple setup and calibration.
• On Screen Step by Step Instructions.
• 5 Buttons for easy Operator Interface.
• Option to add up to 6 Relay Outputs.
• Analogue Output Retransmission option.
• Serial RS485/RS232 port option with Modbus RTU.
Ethernet port option with Modbus TCP.
• Wide Range of Power Supply options from 10V to 265V.
• Multiple functions available for customising to your application.
www.intech.co.nz/in-p
MODEL
IN-P
DESCRIPTION
Multifunction Indicator.
6 Digit LED Display.
6 Set Points.
Standard Power Supply; 85~265Vac / 95~370Vdc
PRC1
1x 4~20mA input + 24Vdc excitation
PRC2
2x 4~20mA input + 24Vdc excitation
PRC4
4x 4~20mA input + 24Vdc excitation
PRC8
8x 4~20mA input + 24Vdc excitation
TC1
1x Thermocouple input Types B, J, K, N, R, S, T
TC4
4x Thermocouple input Types B, J, K, N, R, S, T
RTD1
1x RTD Pt100 input
RTD4
4x RTD Pt100 input
OPTIONS
R2
2x 5A Relay Outputs
R4
4x 5A Relay Outputs
R6
6x 5A Relay Outputs
A
Analogue Output Retransmission
4~20mA
WS232
Serial Port RS232
Includes Modbus RTU
WS485
Serial Port RS485
Includes Modbus RTU
WE
Ethernet Port
Ascii or Modbus TCP
LV
Low Voltage Power Supply; 15~48Vac / 10~72Vdc
FUNCTIONS (Select One)
A
Standard indicator with alarm/control functions
B
Auto or manual scanner with alarms
C
Maths functions, (i) √, (ii) Difference, (iii) Average, (iv) Hi / Lo Select
D*
Hold, Tare, Reset (External switches connect to rear terminals)
E*
Flow Rate + Totalising
F*
Energy display & totaliser (flow x ∆T)
G
Step controller
H*
Auto / Manual Station
I
Retransmission
J
Other Functions – please specify
K
Data Logging
* Available on channel one only.
16
IN-P
PROCESS INDICATORS
W!
E
N
Common Features;
• Simple setup and calibration.
• On Screen Step by Step Instructions. • Analogue Output Retransmission option.
• 5 Buttons for easy Operator Interface. • Serial RS485/RS232 port option with Modbus RTU (excluding IN-R).
• Options to add up to 6 Relay Outputs. • Wide Range of Power Supply options from 10V to 265V.
MODEL
DESCRIPTION
IN-R
Large Display Tachometer Indicator
4 Digit Large LED Display.
Microprocessor Based for Wide Range Calibration.
Inputs: 0~30V, magnetic pickup, NPN, PNP, TTL, Namur.
4 Set Points with delay.
4 LED’s for Alarm indication.
Standard Power Supply; 85~265Vac / 95~370Vdc
www.intech.co.nz/in-r
IN-RT
Flow Rate Indicator with Totaliser
6 Digit LED Display.
Inputs: 0~30V, magnetic pickup, NPN, PNP, TTL, Namur.
4 Set Points with delay.
Standard Power Supply; 85~265Vac / 95~370Vdc
www.intech.co.nz/in-rt
IN-RTB
Flow Rate and Batching Controller
Dual 6 Digit LED Displays.
View Flow Rate & total simultaneously.
Inputs: 0~30V, magnetic pickup, NPN, PNP, TTL, Namur.
5 Set Points annunciator LED’s.
Standard Power Supply; 85~265Vac / 95~370Vdc
www.intech.co.nz/in-rtb
INTECH INSTRUMENTS
IN Series
IN-R
IN-RT
OPTIONS
2
2x 5A Relay Outputs
4
4x 5A Relay Outputs
6
6x 5A Relay Outputs
A
Analogue Output Retransmission
Available in 4~20mA or 0~10V (specify when ordering)
S
Serial Port RS485 or RS232 (specify). Includes Modbus RTU
Note: Not available for the IN-R
LV
IN-RTB
Low Voltage Power Supply; 15~48Vac / 10~72Vdc
LOOP POWERED INDICATOR
LPI-LCD-5
Panel Mount Indicator. Loop powered
MODEL
DESCRIPTION
LPI-LCD-5
Panel mount. Loop powered.
Input;
4~20mA, 2 wire.
Display;
5-digit LCD of 12.5mm height.
Volts Drop;
3.9V @ 20mA.
Scaling;
Programmable between -19999 to 30000.
Max Resolution;
50,000 counts.
Accuracy;
±0.02% of reading plus 2 digits.
Decimal Point;
Programmable to six positions.
Temperature;
-10°C to +50°C.
Protection;
IP65.
Housing;
Plastic. 96 x 48mm.
Cover
For Ordering Code & Specification:
www.intech.co.nz/lpi-lcd
Option; Splash proof lockable security cover; IP65.
17
PLC MULTIPLEXERS
INTECH INSTRUMENTS
2100-M
•
•
•
•
•
16 single ended inputs.
Field programmable input ranges.
Field programmable output signals.
0.1% accuracy.
Universal power supply:
Standard; 85~264Vac/dc or
23~90Vdc. (Field selectable).
Optional; 10~28Vac/dc.
MODEL
• Inputs: Milli-amps.
RTD.
Voltage, mV.
• Channel stepping mode, ‘clock/reset’
or ‘binary’, is field programmable.
• DIN rail mount.
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
2100-M-I
Milli-amp inputs.
Programmable input ranges within 0~2 to 20mA.
Programmable output, 8 ranges within 0~20mA and 0~10Vdc.
2100-M-R
RTD inputs.
Standard input DIN Pt100, others by request.
Programmable input ranges within -200~0~20 to 600°C.
Programmable output, 8 ranges within 0~20mA and 0~10Vdc.
2100-M-V
Voltage inputs.
Programmable input ranges within 0~200mV to 10Vdc.
Programmable output, 8 ranges within 0~20mA and 0~10Vdc.
www.intech.co.nz/2100-m
OPTIONS
2100-M-x-L
Low voltage universal power supply = 10~28Vac/dc.
Please Note: Modbus Protocols are NOT available with the 2100-M.
If you require a multiplexer with Modbus Protocols please view the 2100-A16 on page 19 >>
ISOLATING INTERFACE MODULES
IN-ICM
•
•
•
•
•
The IN-ICM is used as an isolating interface between control units.
Ideal for the 2100-M multiplexer on the ‘clock-reset’ control system.
DIN rail mount.
3.0kVac/dc input to output isolation for 1 min.
Each unit has two independent input/output channels.
MODEL
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
Isolating ‘clock-reset’ interface module.
Two inputs; 230Vac.
IN-ICM-230Vac
Hysterisis;
75Vac, typical.
Two outputs; Open collector, 30V at 100mA maximum.
IN-ICM-115Vac
Isolating ‘clock-reset’ interface module.
Two inputs; 115Vac.
Hysterisis;
40Vac, typical.
Two outputs; Open collector, 30V at 100mA maximum.
IN-ICM-24V
Isolating ‘clock-reset’ interface module.
Two inputs; 24Vac/dc.
Hysterisis;
8Vac, 10Vdc, typical.
Two outputs; Open collector, 30V at 100mA maximum.
Typical connection for IN-ICM
IN-ICM
230Vac
115Vac
24Vac/dc
18
Two digital inputs
Solid-state or contact.
Two solid-state outputs
Open collector
30v at 100mA
www.intech.co.nz/in-icm
Intech multiplexer.
Controller.
PLC input.
Computer input.
2100-A16 Multiplexer
• Each input is user selectable in MicroScan software to
•
•
•
•
any of the following:
Thermocouple, RTD (Pt100/Pt1000), mA, mV, volts.
16 analogue differential inputs, (RTD single ended).
2 relay outputs, for control or alarm functions.
2 analogue outputs.
4 isolated digital inputs.
• Comms – RS485 or RS422 selectable,
RS232 optional. MODBUS-RTU Standard.
• Channel selection;
‘binary’ or ‘clock/reset’ (selectable).
• 0.1% accuracy.
• DIN rail mount.
www.intech.co.nz/2100-a16
MODEL
2100-A16
INTECH INSTRUMENTS
INTELLIGENT MULTIPLEXER
DESCRIPTION
Intelligent analogue input multiplexer. 16 channels.
Analogue input ranges; scaled within the following span limits:
mV.
0~25mV to ±500mV.
volts.
0~1V to ±15Vdc.
mA.
0~1mA to ±100mA (4~20mA default).
RTD.
0~25°C to -200~850°C. Pt100/Pt1000 selectable.
RTD inputs must be either Pt100 or Pt1000 not a mixture.
Thermocouple.
K, J, N, T, R, S, B, E, with CJC.
Range must be within -200~0~1800°C.
Resolution; 16 bit
Differential; 18 volts maximum.
Power supply; 85~264Vac/dc or 23~90Vdc, selectable.
10~28Vac/dc, optional.
PLC control
Channel select;
Clock/reset or binary selectable.
Analogue output;
1 only,
4~20mA, 0~20mA. Selectable.
0~10Vdc, 2~10Vdc. Factory option.
Computer control
Analogue output;
1 only,
4~20mA, 0~20mA. Selectable.
0~10Vdc, 2~10Vdc. Factory option.
Relay outputs;
2 only,
N/O contacts.
Rating, 1 amp 30Vac/dc.
Comms;
Isolated RS485 (2 wire), RS422 (4 wire), selectable.
RS232, optional. Modbus RTU standard.
Baud rate;
9600, 4800, 2400, selectable.
PLC
2100-A16
Additional
multiplexers.
OPTIONS
2100-A16-RS232
RS232 option fitted to 2100-A16.
(Supplied with 5 metres cable)
2100-A16-L
Power supply of 10~28Vac/dc fitted.
The MicroScan system and the PLC can access the 2100-A16 multiplexer at the same time.
PLC
2100-IS
MicroScan V5
2100-A16
Multiplexer
TO FURTHER INTECH
2100 SERIES HARDWARE
TO FURTHER 2100-A16
MULTIPLEXERS
19
PLC ANALOGUE OUTPUT EXPANSION UNIT
INTECH INSTRUMENTS
2100-AO
• Field station with 8 analogue outputs.
• Analogue output resolution:
• Comms – RS485 or RS422 selectable,
4, 8 or 12 bit, selectable.
• DIN rail mount.
• Channel selection; ‘binary’ or ‘clock/reset’ (selectable).
• Easy programming via the comms port.
RS232 optional.
www.intech.co.nz/2100-ao
MODEL
DESCRIPTION
Field station.
8 analogue outputs.
This is the 2100-AO unit used as an output expander for PLC
systems.
2100-AO
PLC
Analogue output ranges;
(8 channels)
mA.
4~20mA, 0~20mA. Selectable.
volts.
0~10Vdc, 2~10Vdc. Factory option.
Analogue input ranges;
(1 channel. Signal from the PLC.)
mA.
4~20mA, 0~20mA. Selectable.
volts.
0~10Vdc, 2~10Vdc. Factory option.
Resolution;
4, 8 or 12 bit, selectable.
Channel selection; Binary or clock/reset.
Power supply;
85~264Vac/dc or 23~90Vdc, selectable.
10~28Vac/dc, optional.
Comms;
Isolated RS485 (2 wire), RS422 (4 wire), select.
RS232 optional.
Baud rate;
9600, 4800, 2400, selectable.
OPTIONS
2100-AO
2100-AO-RS232
RS232 option fitted to the 2100-AO.
(Supplied with 5 metres cable).
2100-AO-L
Power supply of 10~28Vac/dc.
2100-AO-VIO
Analogue input/output signal of 0~10Vdc, 2~10Vdc.
Additional Field Stations
PLC
2100-AO
8 analogue outputs
4~20mA
Channel selection.
Clock/reset or
BCD
Analogue output levels set by 4~20mA in the PLC.
PLC
2100-AO
8 analogue outputs
BCD
Channel selection.
Clock/reset or
BCD
Analogue output levels set by BCD in the PLC.
20
• The 2100-IS converts and isolates RS232 from a computer to RS485 or RS422 for
communication to data high-way stations.
• Internal audible and relay output alarm for communication failure.
• Desk top module, complete with serial cable and power cord.
• Radio modem compatible.
MODEL
DESCRIPTION
RS232 to RS485 or RS422 (selectable) converter. Isolating.
Comms baud rate; 9600 (default); 19200, 4800 (optional).
2100-IS
RelayConverter
output;
1 relay,
change over.
RS232
Isolating
Rating, 1 amp, 24Vdc.
Power supply;
-AO 9V plug pack (supplied with 2100-IS).
OPTIONS
2100-IS
INTECH INSTRUMENTS
COMMS CONVERTERS
2100-IS
Adaptor kits for modems etc also available - please contact Intech.
www.intech.co.nz/2100-is
RS232 Converter Kit Non-Isolating
• The 2100-NS converts RS232 from a computer to RS422/RS485 for
communication to data high-way stations.
MODEL
DESCRIPTION
2100-NS
RS232 to RS422/RS485 converter kit. Non-isolating.
Comms baud rate; 9600 [default]; 4800, 2400 (optional).
Power supply;
9 volt plug pack (supplied with 2100-NS).
www.intech.co.nz/2100-ns
2100-NS Kit
USB to RS485 Converter
• The USB485 converts USB from a computer to RS485 for communication to data high-way stations.
• Only use for temporary monitoring, for industrial environments we recommend using a physical RS232 connection.
MODEL
DESCRIPTION
USB485
USB to RS485 converter. Non-isolating.
Powered from computer USB powered port.
3m length.
www.intech.co.nz/usb485
USB485
2100-NET
2100-4S
MODEL
DESCRIPTION
Ethernet TCP/IP to serial converter. Isolating.
Comms baud rate; RS422 / 485 / 232
(Software Selectable) 19200, 9600, 4800.
2100-NET Power supply; 85~264Vac/dc; 50/60Hz; 10VA.
23~90Vdc; 10VA.
10~28Vac/dc; 50/60Hz; 10VA.
www.intech.co.nz/2100-net
2100-4S
RS422 to RS485 converter
The 2100-4S is a compact, DIN rail mount module that converts RS422
to RS485 for communication to a field data logging or PLC system.
MODEL
DESCRIPTION
RS422 to RS485 converter.
Comms baud rate; RS422 / 485
(Software Selectable) 19200, 9600, 4800.
2100-4S Power supply; 85~264Vac/dc; 50/60Hz; 10VA.
23~90Vdc; 10VA.
10~28Vac/dc; 50/60Hz; 10VA.
www.intech.co.nz/2100-4s
2100-NET
21
2300 SERIES I/O REMOTE STATIONS
INTECH INSTRUMENTS
Stand-alone Analogue and Digital Input/Output stations - Low cost
Connects to MicroScan V5 software
Low Cost I/O Remote Stations.
MODBUS RTU with MODBUS TCP option.
MicroScan V5 Compatible—Seamless Integration.
Also ideal for use when inputs/outputs are required for a PLC and
Modbus comms are available
Plug-in connectors makes replacement easy.
Programmable Ranges within input type.
1.0 kV or greater Isolation.
0.2% Accuracy (12 Bit).
Compact DIN rail mount Enclosure
LEDs indicate I/O status plus comms and Power Supply.
Comms Fail Alarm (Optional).
Power Supply; 24Vdc.
•
•
•
•
www.intech.co.nz/2300
MODEL
2300-A8I
2300-A8II
2300- A8VI
2300-Tc8
2300-RTD6
2300-MULTI
2300-D16
2300-RO4
•
•
•
•
•
•
•
•
DESCRIPTION
8 x 4~20mA inputs, single ended (all input negatives internally connected)
0~20mA inputs programmable
250 ohms input resistance
1.5KV isolation between inputs and power supply and comms (RS485)
Power Supply = 24Vdc @ 30mA typical
Requires an independent and isolated power supply to power logic inputs
4~20mA inputs
Commoned
8 x 4~20mA inputs, Isolated 1.0KV isolation between each input
0~20mA inputs programmable
250 ohms input resistance
1.5KV isolation between inputs and power supply and comms (RS485)
Power Supply = 24Vdc @ 40mA typical
4~20mA inputs
Isolated
8 x Voltage inputs, Isolated 1.0KV isolation between each input
0~10V or 2~10V inputs programmable
20 Kohms input resistance
1.5KV isolation between inputs and power supply and comms (RS485)
Power Supply = 24Vdc @ 40mA typical
Volts inputs
Isolated
8 x Thermocouple & mV inputs, Isolated 350V peak isolation between each input
Programmable inputs type K, J, T, E, N, B, S, R, with CJC
Programmable mV inputs 0~50mV, -100~100mV
1.5KV isolation between inputs and power supply and comms (RS485)
Power Supply = 24Vdc @ 40mA typical
Thermocouple & mV
Isolated
6 x RTD inputs, Pt100, Pt1000, Ni120, Ni1000
1.5KV isolation between inputs and power supply and comms (RS485)
Resolution = 0.1°C
Power Supply = 24Vdc @ 55mA typical
RTD input
6 x combination analogue inputs, single ended
2 x RTD inputs, 2 x 4~20mA inputs, 2 x Voltage inputs;
1 x 4~20mA output, 4 x Digital inputs, 2 x Digital outputs
1.5KV isolation between inputs and power supply and comms (RS485)
Power Supply = 24Vdc @ 70mA typical
Combination inputs
and Outputs
16 x Digital inputs
Input voltage; 12~24Vdc
1.5KV isolation between inputs and power supply and comms (RS485)
Power Supply = 24Vdc @ 30mA typical
Digital inputs
4 x Relay outputs; Change over contacts
Contact rating; 240Vac @ 0.5A, 28Vdc @ 1A
1.0KV isolation between inputs and power supply and comms (RS485)
One output can be dedicated to Comms Fail Alarm
Power Supply = 24Vdc @ 100mA typical
Relay outputs
24Vdc Power Supply Options:
22
PSW-2
www.intech.co.nz/psw-2
Output Voltage; 24Vdc
Max current; 200mA continuous
Input Power Supply; 100~264Vac/dc (Medium setting: 23~90Vdc)
PSW-10
Output Voltage; 24Vdc
Max Current; 1 Amp continuous
Input Power Supply; 100~264Vac/dc
www.intech.co.nz/psw-10
PSW
2300 SERIES I/O REMOTE STATIONS
USB
TCP/IP
MicroScan V5
MicroScan V5
RS232
MicroScan V5
RS232
2100-IS or 2100-NS
RS232 to RS485 Converter
TCP/IP
USB
RS485
INTECH INSTRUMENTS
Examples of connectivity - RS485 data Hi-Way
USB485
2300-NET
RS485
RS485
RS232 Converter Isolating
Alarm for communication failure
• The 2100-IS and 2100-NS converts RS232 from a computer to RS485 for communication to the 2300 series stations.
MODEL
2100-IS
DESCRIPTION
RS232 to RS485 Isolating Converter.
Comms baud rate; 9600
Relay output;
1 relay, change over.
Rating, 1amp, 24Vdc.
Power supply;
9V plug pack (supplied with 2100-IS).
Internal audible and relay output alarm for communication failure.
www.intech.co.nz/2100-is
2100-IS
RS232 Converter Kit Non-Isolating
MODEL
DESCRIPTION
2100-NS
RS232 to RS485 converter kit. Non-isolating.
Comms baud rate; 9600
Power supply;
9 volt plug pack (supplied with 2100-NS).
www.intech.co.nz/2100-ns
USB to RS485 Converter
MODEL
2100-NS Kit
DESCRIPTION
USB to RS485 converter. Non-isolating.
USB485
Powered from computer USB powered port. 3m length.
Note: Only use for temporary monitoring, for industrial
environments we recommend using a physical RS232 connection.
www.intech.co.nz/usb485
USB485
TCP/IP to RS485 Converter Isolating
• The 2300-NET converts TCP/IP to RS485 for communication to the 2300 series stations.
MODEL
DESCRIPTION
Ethernet TCP/IP to RS485 Converter. Isolating.
2300-NET
PSW-2-X
Comms baud rate; 9600
Power supply;
24Vdc
Modbus TCP to Modbus RTU
Compact DIN rail mount Enclosure
www.intech.co.nz/2300-net
If you require a 24Vdc Power supply for the 2300-NET.
2300-Net
23
DIGITAL I/O STATION
INTECH INSTRUMENTS
Intech Micro 2100 - Series. Data high-way Remote Stations
• Remote station with 12 digital inputs and 12 relay outputs.
•
Each input is user selectable in MicroScan software to
any of the following;
on/off state, flow rate and totalising, counting.
• Comms - RS485 or RS422 selectable,
RS232 optional.
• Radio modem compatible.
• DIN rail mount.
www.intech.co.nz/2100-d
2100-D
MODEL
2100-D
DESCRIPTION
Digital input/output remote station.
Digital inputs; 12 opto isolated, 5-30Vdc, 500Hz max.
(max count; 16383, then resets.)
Relay outputs; 12 relays. Rating, 2 amp, 30Vdc/250Vac.
(10 c/o and 2 n/o contacts.)
Power supply; 85~264Vac/dc or 23~90Vdc, selectable.
10~28Vac/dc, optional.
Comms;
Isolated RS485 ( 2 wire), RS422 (4 wire), selectable.
RS232 optional.
Baud rate;
9600, 4800, 2400, selectable.
OPTIONS
2100-D
2100-D-RS232
2100-D-L
RS232 option fitted to 2100-D.
(Supplied with 5 metres cable).
Power supply of 10~28Vac/dc fitted.
RELAY EXPANSION UNIT
2100-R2
• The 2100-R2 plugs into either the 2100-A16 or the 2100-A4 to expand the number of relay outputs.
• 16 relay outputs. Can use 2x 2100-R2 with the 2100-A16 for a total 32 relay outputs!
• DIN rail mount.
www.intech.co.nz/2100-r2
MODEL
2100-R2
DESCRIPTION
Relay output expansion unit.
Relay outputs; 16 relays, change over contacts.
Rating, 2 amp, 30Vdc / 230Vac.
Power supply; 85~264Vac/dc or 23~90Vdc, selectable.
10~28Vac/dc, optional.
OPTIONS
2100-R2-L
Power supply of 10~28Vac/dc fitted.
2100-R2
24
Intech Micro 2100 - Series. Data high-way Remote Stations
• Remote station with:
• Radio modem compatible.
8 analogue outputs.
8 analogue inputs.
12 digital inputs.
2 relay outputs.
• Easy programming by MicroScan maps.
• Programmable station number.
• Four of the digital inputs are user selectable in
MicroScan software to any of the following:
on/off state,
flow rate and totalising,
counting (max 50 Hz.)
• Comms - RS485 or RS422 selectable,
RS232 optional.
• 12 bit resolution.
INTECH INSTRUMENTS
ANALOGUE & DIGITAL I/O STATION
• Universal ac/dc power supply.
www.intech.co.nz/2100-ao
2100-AO
MODEL
DESCRIPTION
Analogue and Digital I/O remote station.
Analogue input and output.
Digital input and relay output.
2100-AO
Analogue input ranges;
mA.
0~20mA, 4~20mA. Selectable.
volts.
0~10Vdc, 2~10Vdc. Factory option.
Analogue output selectable ranges;
mA.
0~20mA, 4~20mA. Selectable.
volts.
0~10Vdc, 2~10Vdc. Factory option.
Digital inputs; 12 opto isolated, 5~30Vdc.
4 of which can be used for counting. (50 Hz max)
(max count; 16383, then resets.)
Relay outputs; 2 relays. Rating, 2 amp, 30Vdc / 250Vac.
(n/c or n/o contacts, select.)
Power supply; 85~264Vac/dc or 23~ 90Vdc, selectable.
10~28Vac/dc, optional.
Comms;
Isolated RS485 (2 wire), RS422 (4 wire), selectable.
RS232, optional.
Baud rate;
9600, 4800, 2400, selectable.
2100-AO
OPTIONS
2100-AO-RS232
2100-AO-L
RS232 option fitted to 2100-AO.
(Supplied with 5 metres cable).
Power supply of 10~28Vac/dc fitted.
Typical connection for 2100-AO unit.
Computer
8 analogue outputs
Comms
8 analogue inputs
2100-AO
2 relay outputs
12 digital inputs
25
ANALOGUE INPUT STATION
INTECH INSTRUMENTS
Intech Micro 2100 - Series. Data high-way Remote Stations
• Each input is user selectable in MicroScan software
to any of the following;
Thermocouple, RTD, mA, mV, volts.
• 16 analogue differential inputs, (RTD single ended).
• 4 digital inputs, for counting or on/off status.
• 2 relay outputs, for control or alarm functions.
• 2 analogue outputs.
• Comms – RS485 or RS422 selectable,
MODBUS-RTU Standard, RS232 / Ethernet TCP/IP
optional.
• Input expansion, up to four 16 input 2100-M units.
• Output expansion, up to two 16 relay 2100-R2 units.
• Radio modem compatible.
• 16 resident ‘computer free’ on board controllers.
• Use with the two on board relays or the 2100-R2 unit.
www.intech.co.nz/2100-a16
2100-A16
Ethernet
MODEL
DESCRIPTION
2100-A16
Analogue input remote station. 16 channels.
Analogue input ranges; scaled within the following span limits;
mV.
0~25mV to ±500mV.
volts.
0~1Vdc to ±15Vdc.
mA.
0~1mA to ±100mA. (4~20mA default)
RTD
0~25°C to -200~850°C. Pt100/Pt1000 selectable.
RTD inputs must be either Pt100 or Pt1000 not a mixture.
Thermocouple
K, J, N, T, R, S, B, E, with CJC.
Range must be within -200~0~1800°C.
Resolution;
16 bit.
Differential;
18 volts maximum.
Digital inputs;
4 opto isolated, 5~30Vdc, 50Hz max.
max count, 16383 and rolls over.
Analogue outputs; 2 channels. (Not available when Multiplexers are connected).
4~20mA, 0~20mA. Selectable.
0~ 10Vdc, 2~10Vdc. Factory option.
Relay outputs;
2 relays, n/o contacts, Rating, 1 amp 30Vac/dc.
Power supply;
85~264Vac/dc or 23~90Vdc, selectable.
10~28Vac/dc, optional. (Refer below.)
Comms;
Isolated RS485 (2 wire), RS422 (4 wire), selectable.
Modbus RTU Standard.
RS232 / Ethernet TCP/IP optional. (Refer below.)
Baud rate;
9600, 4800, 2400, selectable.
Control;
Set points and hysterisis values for the 16 resident on
board controllers are downloaded from the MicroScan
mimic package software and held in permanent memory.
2100-A16-Net
RS232,
RS422/485
2100-A16
Remote station
2100-M
Multiplexer
A maximum of 4 multiplexers
to each 2100-A16. Each
multiplexer uses one of the
2100-A16 16 analogue
inputs.
2100-R2
16 relay outputs
2100-R2
16 relay outputs
26
OPTIONS
2100-A16-NET
Analogue input remote station fitted with Ethernet TCP/IP connection.
MicroScan.TCP & Modbus.TCP protocols.
www.intech.co.nz/2100-a16-net
2100-A16-RS232 RS232 option fitted to 2100-A16. (Supplied with 5 metres cable).
2100-A16-L
Power supply of 10~28Vac/dc fitted.
Expansion notes
Note 1
Input expansion; This is a standard feature.
Supports up to four 2100-M multiplexers.
The two analogue outputs are not available with this option.
Note 2
Output expansion; Supports up to two 2100-R2 relay output modules.
This unit allows the station to ‘stand alone’ as a 16 channel controller for a
combination of (on/off or heat/cool) control and alarm functions.
The heat/cool option utilises 2 relays per channel.
The 2100-A16 (rev 1.3) can now support 16 heat/cool controllers. For this,
32 relay O/P’s are required.
Intech Micro 2100 - Series. Data high-way Remote Stations
• Each channel can be any of the inputs and any of the
ranges shown below by programming on board links
and software selection.
• 4 analogue inputs, single ended, 12 bit resolution.
• 4 digital inputs, for counting or on/off status.
• 4 relay outputs, 8 relays optional, for control or alarm.
• Comms – RS485 or RS422 selectable,
RS232 optional.
• Input expansion, up to four 2100-M multiplexers.
• Output expansion of one 2100-R2 (16 relays).
• 4 resident ‘computer free’ on board controllers.
• Radio modem compatible.
• 2 analogue outputs.
INTECH INSTRUMENTS
ANALOGUE INPUT STATION
www.intech.co.nz/2100-a4
2100-A4
MODEL
DESCRIPTION
2100-A4
Analogue input remote station. 4 channels.
Analogue input selectable ranges;
mV.
0~75mVdc, 0~150mVdc, 0~300mVdc.
volts.
0~2.5Vdc, 0~5Vdc, 0~10Vdc.
mA.
0~10mA, 0~20mA, 4~20mA.
Pt100.
-50~140°C, -50~350°C, -50~850°C.
Thermocouple.
K, J, N, T, E, with CJC.
Range must be within 100~1300°C.
Tx supply;
20Vdc, 80mA.
Digital inputs;
4 opto isolated, 5-30Vdc, 50Hz max.
max count, 16383 and rolls over.
Relay outputs;
4 relays, c/o contacts, Rating, 2 amp, 30Vdc / 250Vac.
4 additional relays, optional. (Refer below.)
Analogue outputs; 2 channels;
Selectable; 4~20mA, 0~20mA, 0~10Vdc, 2~10Vdc.
Power supply;
85~264Vac/dc or 23~90Vdc, selectable.
10~28Vac/dc, optional. (Refer below.)
Comms;
Isolated RS485 (2 wire), RS422 (4 wire), selectable.
RS232 optional. (Refer below.)
Baud rate;
9600, 4800, 2400, selectable.
Control;
Set points and hysterisis values for the 4 resident on
board controllers are downloaded from the MicroScan
mimic package software and held in permanent memory.
OPTIONS
2100-A4-RS232 RS232 option fitted to 2100-A4. (Supplied with 5 metres cable).
2100-A4-L
Power supply of 10~28Vac/dc fitted.
2100-A4-E
Relay output expansion. A total of 8 relay outputs.
This unit is the same size as the 2100-A16.
2100-A4
Remote station
2100-M
Multiplexer
A maximum of 4 multiplexers
to each 2100-A4. Each
multiplexer uses one of the
2100-A4 4 analogue inputs.
2100-R2
16 relay outputs
27
MINIPACKS
INTECH INSTRUMENTS
Complete Chart Recorder replacement Packages
MINI PACK 8
UP TO 8 CHANNELS OF RECORDING
Remote stations available for the following;
milli-amps, milli-volts, Voltage, Thermocouple, RTD,
Combination.
<< Refer pages 22/23
RS232 or USB
RS485
SOFTWARE
1x
MICROSCAN V5 RECORDER LITE 8
Supplied with USB Dongle
& HARDWARE
1x
COMMS CONVERTER RS232 to RS485 or
USB to RS485 (for temporary monitoring only)
(specify converter type when ordering, RS232 is default).
1x
INTECH MICRO 2300 Remote Station
c/w PSW-2 Power Supply 24Vdc
Specify input type when ordering: Voltage/Current/Thermocouple/RTD/Multi
W!
E
N
Option 1 - If using 2300-RTD6 (6x RTD inputs)
Option 2 - If using 2300-A8I (8x 4~20mA inputs Non-isolated)
Option 3 - Using any other 2300 I/O remote station
Upgrade - Comms fail alarm and/or Alarm outputs (add 2300-RO4 station)
MINI PACK 16
UP TO 16 CHANNELS OF RECORDING
Each input channel can be individually programmed to any
of the following:
Pt100, Pt1000, Thermocouple, milli-amps, milli-volts,
Voltage.
RS232 or USB
RS485/RS422*
SOFTWARE
1x
MICROSCAN V5 RECORDER LITE 16
Supplied with USB Dongle
& HARDWARE
1x
COMMS CONVERTER RS232 to RS485 or
USB to RS485 (for temporary monitoring only)
(specify converter type when ordering, RS232 is default).
1x
INTECH MICRO 2100-A16-X
MINI PACK 32
UP TO 32 CHANNELS OFRECORDING
Each input channel can be individually programmed to any
of the following:
Pt100, Pt1000, Thermocouple, milli-amps, milli-volts,
Voltage.
RS232 or USB
RS485/RS422*
SOFTWARE
1x
MICROSCAN V5 RECORDER LITE 32
Supplied with USB Dongle
& HARDWARE
1x
COMMS CONVERTER RS232 to RS485 or
USB to RS485 (for temporary monitoring only)
(specify converter type when ordering, RS232 is default).
2x
INTECH MICRO 2100-A16-X
* 2100-A16 RS422 available with 2100-NS/IS RS232 converter only.
# 2100-A16 RTD inputs must be either Pt100 or Pt1000 not a mixture.
www.intech.co.nz/minipack
28
Schematic showing Connection of 2100 series plus controllers to PC and PLC
SOFTWARE
• Windows
• MicroScan
• Energy Wizard
Networking to other computers
TCP Network to 2100-A16-NET etc
Total stations all up = 400
PLC data highway
PLC units that
communicate with
MicroScan
Omron C series
Allan Bradley
Fuji NJ series
Mitsubishi A series
Toshiba
Siemens RK512
Modbus ASCII
Any PLC units with
DDE servers
Radio modem
compatible
RS232
to
RS422/RS485
Isolating converter
2100-A16
2100-M
Multiplexers
2100-AO
Analogue Output
Remote station
Intech/Shimaden data highway
PLC station
2100-IS
INTECH INSTRUMENTS
INTECH MICRO 2100-SERIES
2100-M
Multiplexer
A maximum of
4 multiplexers to
each 2100-A16.
2100-R2
16 relay outputs
Optional tandem connection
2100-R2
2100-A16
16 relay outputs
Programmable
Multiplexer
Radio modem compatible
2100-AO
Remote station
8 analogue outputs
8 analogue inputs
12 digital inputs
2 relay outputs
2100-D
2100-A4
Remote station
2100-M
Multiplexer
A maximum of
4 multiplexers to
each 2100-A4.
Remote station
12 digital inputs
12 relay outputs
2100-R2
Shimaden
16 relay outputs
Controllers
Digital displays
Notes:
1. RS485/422 = max 100 stations per data highway
2. TCP = max 400 stations
A RS422 or RS485 data highway
transmission distance of 1200 metres is
typical before a booster unit is required.
29
DATA LOGGING AND SCADA SOFTWARE
INTECH INSTRUMENTS
MicroScan Recorder Features - Version 5
RECORDER MODULE
•
•
•
•
•
•
•
•
•
•
•
•
Real-time line graphs
Real-time data screens
Data analysis
Batch recording
Continuous recording
Mathematical blocks e.g.
-subtraction
-addition
-multiply
-divide
-Sq root
-average
-min/max
-nat. log
Totalising in engineering units
Total hours run facility
Data logs to printer
ISO 9000 support
Data storage to disk
Help screens
•
•
•
•
•
•
•
•
•
•
•
Historical retrieval
Historical search
History replay
Function key support
Alarm handling and printing
Event handling and printing
Comment entry by operators
Report generator
User log-on and audit
DDE support
Communicates with;
- Intech field stations
- Most PLC’s
• Multi-level passwords
• Excel support
• Cost effective field interface
hardware
• MicroScan is a complete Windows based SCADA software
product, meeting the demands of industrial, commercial, and
research environments.
• Start off small with the world’s best ‘Recorder Module’ for QA,
mandatory data collections, plus plant wide monitoring, or
jump straight into a full system with Recorder and Mimic
(MM1) modules.
• Add the powerful ‘Network Module’ to share the data with
managers, accountants, engineers, and others.
www.intech.co.nz/microscan
30
DATA LOGGING AND SCADA SOFTWARE
• Live screen graphics
• PLC operator control
• Current plant values and
configuration.
• Intech Micro remote station
support
• Alarm handling and printing
• Alarm logs
•
•
•
•
INTECH INSTRUMENTS
MIMIC MODULE
Controller support
DDE support
Network support
Up to 512 on/off software
controllers each with;
- Set point with differential
adjustment
- Deviation high and low
alarms.
CONTROLLER MODULE
• Up to 99 Shimaden controllers.
• Complete set up and monitoring of controllers and indicators.
PLC INTERFACE MODULE
• Allows communication between PLC’s and Recorder/Mimic modules.
Note: Check with Intech engineers to ensure that the interface is
available for the PLC to be used.
MICROSCAN TOOL BOX MODULE
•
•
•
•
•
•
•
Data transfer
Mathematical formulas
Passwords
Audit tracking
Step controller
Time clocks
Data average & min/max
• Time functions
• Data base
• Other special functions
e.g. relative humidity
cylindrical tank volume
list – look-up table
rate of change
NETWORK MODULE
• The ability to store files on a file server
• Price for the network module does not
computer instead of the local computer to
include the Network itself.
which the field hardware is connected.
• Data file duplication for security.
• More than one computer can store files on
the file server, these files can be picked up • The Network should be installed and
successfully running Windows before
by any computer on the network with
installing the MicroScan package.
MicroScan installed.
www.intech.co.nz/microscan
31
DATA LOGGING AND SCADA SOFTWARE
INTECH INSTRUMENTS
MicroScan Software Modules
MicroScan Software “Recorder Packages”.
Model
Version 5
FOR FURTHER INFORMATION
REFER TO THE PREVIOUS TWO PAGES.
www.intech.co.nz/microscan
Comes complete with USB dongle.
Description
R16
MicroScan recorder. 16 inputs, 16 outputs.
R32
MicroScan recorder. 32 inputs, 32 outputs.
R50
MicroScan recorder. 50 inputs, 160 outputs.
R100
MicroScan recorder. 100 inputs, 160 outputs.
R200
MicroScan recorder. 200 inputs, 160 outputs.
R300
MicroScan recorder. 300 inputs, 160 outputs.
R400
MicroScan recorder. 400 inputs, 160 outputs.
R600
MicroScan recorder. 600 inputs, 160 outputs.
R800
MicroScan recorder. 800 inputs, 160 outputs.
R1000 MicroScan recorder. 1000 inputs*, 160 outputs.
*Maximum recorder lines = 1000 made up of 100 pages with 10
lines on each page.
MicroScan Software “Tag Packages”.
Comes complete with USB dongle.
Includes; Recorder, Mimics, Shimaden and DDE.
Model
Description
T50
MicroScan software package.
50 tags.
T75
MicroScan software package.
75 tags.
T150
MicroScan software package.
150 tags.
T300
MicroScan software package.
300 tags.
T500
MicroScan software package.
500 tags.
T750
MicroScan software package.
750 tags.
T5000 MicroScan software package.
5000 tags.*
*Maximum Tags = 5000 (max I/O = 5000).
Mimics (Only available with Tag option);
No of pages; 100 max.
I/O per page; 380 max.
Note 1
Controllers; 500 on/off software controllers,
Each with individual; Set point;
Differential adjustment; Deviation alarms
SYM
Symbol Factory Libraries for Mimics images
www.intech.co.nz/sym
Optional Software Modules.
(Not for Recorder LITE 8, LITE 16 or LITE 32 Packages)
TB+
MicroScan Tool Box.
www.intech.co.nz/toolbox
Data transfer, mathematical formulas, time clocks,
step controller, recipes, data base and remote editor.
PLC
PLC Interface - specify PLC make and model.
P1
P2
P3
P4
P5
P6+
Network Drivers.
Active PC will support 1 Passive PC
Active PC will support 2 Passive PC’s
Active PC will support 3 Passive PC’s
Active PC will support 4 Passive PC’s
Active PC will support 5 Passive PC’s
Active PC will support 6 or more passive nodes.
Version Upgrades (Example from V4 to V5). Are available.
Also available are larger packages and/or modules upgrades.
USB Dongle. MicroScan license tied to hardware dongle, not PC.
Parallel dongle available on special request.
Notes;
- Software locking is no longer available!
- Old Sentinel-C dongles are now redundant and must be returned to
Intech.
32
PLC
MICROSCAN MA5 MOBILE ALARMING 5 SOFTWARE
Main Tank High
Temp Alarm
Value = 85.4 C
Text messages allow you to keep
in touch with your process
“Alarm”
Siemens
MC35
GSM
INTECH INSTRUMENTS
MA5 MicroScan Mobile Alarm and Text Messaging
Receive
Main Tank
High
Temp
Alarm
Value =
85.4 C
SMS Message
(GSM mobile phone)
Acknowledge
After hours on call engineers.
Laboratory staff
•
•
•
•
•
•
•
•
•
•
Alarms immediately sent as text message to mobile phone and/or emailed.
Alarms can be sent sequentially until acknowledged.
Alarm message acknowledgment from mobile phone by returning alarm text message.
Request any plant parameter by sending a text message from mobile phone.
Commissioning / Critical parameters can be configured to be regularly sent as txt msg &/or email.
Plant control settings can be adjusted from mobile phone via plant Mimics.
A log file is kept of all communications and is stored on the PC for audit tracking.
Daily email reports of activity.
Send data automatically between two MicroScan V5 sites.
One Siemens MC35 GSM Modem can connect to multiple MA5 clients across the network.
www.intech.co.nz/ma5
Request Lab Fridge
Temperature
MicroScan MA5 (Mobile Alarming 5) software.
Runs with MicroScan Version 5 software & Microsoft .NET 2.0
MODEL
DESCRIPTION
MA5
For MicroScan V5 software packages.
MA5-Lite
For MicroScan V5 LITE 8, LITE 16,
LITE 32, R16 and R32 packages only.
Includes all features of MA5.
MA5
MC35 Kit*
GSM message hardware kit add:
* Does not include SIM card.
Lab Fridge
Temp =
1.5oC
Features:
• Receive Alarms
• Acknowledge Alarms
• Check Alarms Acknowledged
• Change Alarm setpoints,
Delay, Enable/Disable
• Monitor Critical Parameters
• Request Plant Parameters
• Change Plant Parameters
• Activate Plant Equipment
SHIMADEN LITE SOFTWARE
Features:
• User friendly controller configuration from computer.
• Auto seek; Finds controllers automatically.
• Auto configuration; Shimaden Lite automatically adopts controller configuration.
• Password protection.
• Trend graph of process value and set value.
• Trend graph has last 100 scans.
• Scan settings 1 sec, 15 sec, 1 min.
• Controller identification label.
Shimaden Lite
RS232
2100-IS/NS
RS232 to RS485
Converter
Controllers
RS485
Data Highway
Shimaden Controllers/
Indicators
RS485 or RS232
RS422 or RS232
SR90 Series
SD16A
SR80 Series
FP93
SR23
FP23
SRS10 Series
MR13
FP21
SR25
SD20
SR253
SR73A
Notes;
 The MR13 has no set value (SV)
facility from the computer.
 2100-IS / 2100-NS not required when
using RS232.
 RS232 will connect to one controller
only.
Controllers
33
TEL-LINK RADIO MODEMS
INTECH INSTRUMENTS
Tel-Link Radio Modems and Wireless MicroScan Connections
The Tel-LinkRadio Modems are powered by FCC and ETSI approved MaxStream radio modules with frquency
hopping spread spectrum capability. Radio Modems are available for the 2.4GHz license-free ISM band
(Industrial, Scientific and Medical band).
There is a full range of USB, RS232, RS422 and RS485 interface options available allowing incredible flexibility.
Features:
• MicroScan can now collect data from previously uneconomic areas.
• True peer-to-peer networking (no Master radio needed).
• Networking features allow up to 7 independent pairs (networks) to operate in close proximity.
• Supports all MicroScan Interface baud rates.
• 2.4GHz license-free ISM band (Industrial, Scientific and Medical).
• 19.2 kbps over-the-air data rates.
• Up to 65,000 network addresses available.
• Signal strength reporting for link quality monitoring and debugging.
• Outdoor units are supplied with a stainless steel mounting bracket and U bolts.
• Certified for use in Australia, USA, Canada, Europe and New Zealand.
Note: Tel-Link Radio Modems can also be used with the data loggers on pages 36 to 39 >>
www.intech.co.nz/tel-link
Indoor
MODEL
TL-USBO-24
TL-USBI-24
TL-485O-24
TL-485I-24
TL-232SP-24
TL-232O-24
TL-232I-24
DESCRIPTION
Tel-Link Radio Modem 2.4GHz
USB Outdoor c/w Outdoor 3dBi sleeve di-pole whip Aerial.
USB Indoor c/w Indoor 3dBi half wave whip Aerial.
RS 485/422 Outdoor c/w Outdoor 3dBi sleeve di-pole whip Aerial.
RS 485/422 Indoor c/w Indoor 3dBi half wave whip Aerial.
RS232 Solar Panel (includes battery) c/w Outdoor 3dBi sleeve di-pole whip Aerial.
RS232 Outdoor c/w Outdoor 3dBi sleeve di-pole whip Aerial.
RS232 Indoor c/w Indoor 3dBi half wave whip Aerial.
Aerial Options (Used when greater distances are involved):
Outdoor
TL-AI24-12
TL-AO24-12
Tel-Link Radio Modem Aerials 2.4GHz
Indoor 12dBi Directional
Outdoor 12dBi Directional
Performance:
Indoor Urban: 2.4GHz ISM Band Up to 180m
Outdoor Line of Sight
Ideal* Conditions:
With Dipole
High Gain Antenna
2.4GHz ISM Band - Up to 5km
2.4GHz ISM Band - Up to 15km
Solar Panel
Normal* Conditions:
With Dipole
2.4GHz ISM Band - Up to 1.5km
High Gain Antenna
2.4GHz ISM Band - Up to 3km
Note *
Ideal Conditions = Hill top to Hill top.
Normal Conditions = on 3 meter pole with line of sight and no surrounding trees and buildings.
Note: Tel-Link Radios are supplied with a standard whip Aerial and a plug pack power supply (except for the USB models which are
powered from the computer USB powered port and the solar panel models which include a battery).
The plug pack power supply is 230-240Vac Input, 12Vdc @ 300mA Output. (An extension plug will be supplied when destination is
outside Oceania). You will need to supply your own plug pack (with the same output specifications) if using a different input voltage.
34
Tel-Link Radio Modems and Wireless MicroScan Connections
2100 Series
Remote Station
Example of possible Set-Up:
RS485/422 Data-Hi Way
Tel-Link
Radio
Modems
More Stations
2100 Series
Remote Station
RS232
INTECH INSTRUMENTS
TEL-LINK RADIO MODEMS
2100 Series
Remote Station
RS485/422 Data-Hi Way
More Stations
www.intech.co.nz/tel-link
MicroScan Computer
Note: Tel-Link Radio Modems can also be used with the data loggers shown on pages 36-39 >>
ZIGBEE MODULES
New Wireless ZigBee Technology empowers Intech MicroScan
Example showing MicroScan Software and the
2100-A16 Remote Stations plus ZigBee sleeper
for mobile monitoring:
Comms/TCP LAN
Zig-2400-RB
Base module
Zig-2400-RB
Router module
MicroScan Recorder /SCADA
ZIG-2400 Series
Common Specifications:
Wireless standard; IEEE 802.15.4-2006
Wireless range;
100m typical line of sight
Power supply;
12~24Vdc
Power Consumption; 5 VA
Zig-2400-RB
Router module
2100-A16
Remote Station
2100-A16
Remote
Station
Zig-2400-Sleeper
www.intech.co.nz/zigbee
MODEL
Zig-2400-RB
Temperature
Probes
Allows monitoring of
mobile equipment
DESCRIPTION
Communications;
RS232, RS422, RS485
Duty;
Configurable as Base or Router
Embedded protocol support; MODBUS RTU plus MicroScan default ACSII
Zig-2400-Sleeper No. of temperature channels;
2
External temperature sensors;
Pt100, Pt1000
Selectable temperature ranges;
Within -200C to 850°C
Embedded protocol support; MODBUS RTU plus MicroScan default ACSII
Battery life;
Approx 2 years life when wake up interval set
to 2 minutes.
Option to switch from Sleeper mode to permanently offline.
Zig-2400-TCPMODBUS
Communications;
MODBUS TCP
Duty;
Base
Embedded protocol support; MODBUS TCP
Zig-2400-TCPACSII
Communications;
ASCII
Duty;
Base
Embedded protocol support; MicroScan default ASCII
35
DATALOGGERS
HR Series
INTECH INSTRUMENTS
• Stainless steel case.
• IP66 rating (excludes Humidity types).
• 1~5 year battery life (depending on usage).
• High Accuracy 12 bit^
• Over 500,000* readings can be stored!
• Sampling rate from 1 sec to 10 hrs
www.intech.co.nz/hr-loggers
T-HR
MODEL
T-HR
HT-HR
HT-HR
THT-HR
Tc-HR
WT-HR
HHT-03
Tc-HR Plug Set
Pt-HR
THT-HR
TP-Pt100
mV-HR
mV-HR Lead
Tc-HR
with Plug set
and HHT-03
WT-HR-250
WT-HR-500
WT-HR-1000
WT-HR-1500
WT-HR-2000
pH-HR
Pt-HR
pH-HR Plug Set
with
TP-Pt100
GP-HR
mV-HR
mA1-PS
mA3+P-PS
##VD3-PS
with Test Lead
L-PS
Pt3-PS
P###-HR-PS
pH-HR
with pH probe
Flow-mA2-PS
ACM-mA2-PS
DESCRIPTION
Single temperature.
Internal temperature sensor. Range -30~70°C.
Humidity and temperature.
Humidity and internal temperature sensor. Range -30~70°C.
Humidity and dual temperature. Range -30~70°C. * 64,000 samples.
Humidity, one internal & one external temperature sensor.
Dual temperature, Thermocouple, ^16 bit. (does not include probe)
One internal and one external temperature sensor.
Internal temperature sensor, range -30~70°C.
External temperature sensor, Types J, K, N, R, T. Ranges -250~1760°C.
Type K temperature probe for Tc-HR. Range -30~300°C.
Spear probe 2m pvc cable with handle & mini plug.
Others available, please contact Intech.
70mm lead c/w plugs (Specify thermocouple type).
Dual temperature, Pt100/Pt500/Pt1000. (does not include probe)
One internal and one external temperature sensor.
Internal temperature sensor, range -30~70°C.
External temperature sensor, Pt100/Pt500/Pt1000, range -200~600°C.
Pt100 temperature probe for Pt-HR, range -100~150°C
4.7 x 100mm SS probe with 2m tefzel cable.
Milli-volt. Ranges: ±50mVdc, ±100mVdc, ±200mVdc, ±400mVdc.
Test Lead Set
Water level, air temperature and water temperature.
Air temp. (-30~70°C). Water temp. (0~45°C). * 64,000 samples.
To log water level between 0~0.25m
To log water level between 0~0.5m
To log water level between 0~1.0m
To log water level between 0~1.5m
To log water level between 0~2.0m
Option for 316 S/S for Salt water applications
pH and temperature, ^16 bit.
For use with a Pt100 temperature compensated pH probe (not included)
See pages 42-43 for pH probes available from Intech >>
Fit plug set to pH sensor for use with pH-HR logger.
4 Input General Purpose Logger. (does not include sensors/plug sets)
3 Analogue inputs – individually configurable.
1 Digital pulse input channel.
* Now over 1,000,000 8 bit samples; or over 500,000 12 bit samples.
Standard External Sensors & Plug Sets for GP-HR:
One 4~20mA or 0~20mA input.
Three 4~20mA or 0~20mA inputs c/w One pulse input.
Three DC voltage inputs. ## = Specify voltage up to 32Vdc.
(Maximum voltage input for the GP-HR is 32Vdc (32VD3-PS) - for
voltages >32Vdc use an intermediary transmitter like the PI-D)
Light energy.
Three Pt1000 temp probes. Range = -50~130ºC.
(Logger maximum Pt1000 range is -100~400º C)
Pressure probe - available ranges are:
P100-HR-PS = -15~100psi, P250-HR-PS = -15~250psi,
P500-HR-PS = -15~500psi
Coil or open collector plus two 4~20mA inputs.
Flow metering off the pump run contact plus two 4~20mA inputs.
Note: Please contact Intech for other available options.
GP-HR
SWDL-DLC3USB
SWDL-DLC3
DLC3USB
DLC3
OmniLog Software and DLC3USB download cable Kit (USB)
OmniLog Software and DLC3 download cable Kit (RS232)
Spare HR Series download cable (USB)
Spare HR Series download cable (RS232)
HR-Battery mk3
HR-Battery mk4
Replacement HR Series Mark 3 Battery Kit
Replacement HR Series Mark 4 Battery Kit
with Pt3-PS
View more data loggers on pages 38 & 39 >>
36
•
•
•
•
•
•
•
Small size
7584 samples
Single internal temperature logger
Wide temperature range -20~70ºC
Accuracy of ±0.38°C (0°C to 30°C)
Start modes; On date/time or immediately.
Logging modes; Each channel can be set to log all or any of the following:
Instantaneous readings,
Average reading,
Maximum reading,
Minimum reading
• Continually connected to the computer for instant readings.
• Interrogation over phone lines using a standard modem link.
• Dial a pocket pager on an alarm condition.
Model
MicroToT
SWDL-DLC1
DLC1
www.intech.co.nz/microtot
Description
INTECH INSTRUMENTS
DATA LOGGERS & OMNILOG
MicroToT Logger
Small Single Temperature Logger.
Range -20~70°C, 7584 samples, accuracy = ±0.38°C (0°C to 30°C).
OmniLog Software and DLC1 download cable Kit (RS232).
Spare MicroToT download cable (RS232).
HR-Series Loggers
GP-HR General Purpose 4 channel logger
• Stainless steel case. IP66 rating (excludes Humidity types).
• Over 500,000* readings can be stored! 1~5 year battery life.
• A DLC3USB [USB] or DLC3 [RS232] download cable is
required to connect HR Series loggers to a computer.
• Sampling rate from 1 sec to 10 hrs in 1 second increments.
• Each channel can be set to log all or any of the following;
1. Instantaneous readings.
2. Average reading.
3. Maximum reading.
4. Minimum reading.
• Start modes;
1. On date/time.
2. Immediately.
3. On input condition.
• Stop modes;
1. On date/time.
2. When memory is full.
3. Loop around. (continues logging).
• Continually connected to the computer for instant readings.
• Interrogation over phone lines using a standard modem link.
• Send SMS messages on an alarm condition.
Select any (up to four) of the following channels;
• Three analogue input channels, to log any combination of:
1. Temperature.
2. Humidity.
3. Pressure.
4. Light.
5. Voltage.
6. Current.
7. Wind direction.
• One digital pulse input channel, to log;
1. Rainfall.
2. Wind speed.
3. Flow.
4. Counter (up to 65535) 5. Frequency (up to 60 kHz).
• Internal temperature sensor channel may be activated to
log the ambient temperature of the logger.
• User replaceable battery.
• Over 1,000,000 8 bit samples;
or Over 500,000 12 bit samples!
Over 600 days logging 3x Hi-Resolution Channels every 5
minutes.
www.intech.co.nz/gp-hr
TruTrack OmniLog Software
• The TruTrack OmniLog Data Management software is
an application for reading, displaying, analysing,
organising and exporting data that has been
downloaded from TruTrack data loggers (all types).
• Data can be read from data loggers or retrieved from
previously saved data files.
• A connected data logger can be configured, calibrated,
started, read and stopped by this application.
• Data retrieved from data loggers and previously saved
data files can be viewed and printed in a values spread
sheet list, as a graph or as a statistics report.
These values, graphs and statistics can be displayed
and printed for all data or from a user selected block of
data.
• Data can also be exported in a large range of industry
standard formats so as to be used by other applications.
www.intech.co.nz/omnilog
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Battery Status
Pager
Pager Alarm
Graph
Reports
Formats
Print
Overviews
Dew Point
Trips
Tutorial
Log File
Log Status
Multi channel
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Graph & Values
Exporting Datasets
Graph Colors
Joining Graphs
Light Energy
Pulse Input
Leaf Wetness
Probe Selection
Saving Log Files
Serial Number
Dataset History
Wind Chill Factor
Real Time Screen
Modem Control
•
•
•
•
•
•
•
•
•
•
Offset Calibration
Sample Period
Channel & Probe Setup
Change Dataset units
High Precision Graph Draw
Quick Graph Draw
Typographical Conventions
Calibration Procedures
Humidity Calibration
Light Intensity Calibration
limits
• Units & Scaling
• Displaying Real Time
readings
• Viewing Data in values
37
MULTI PURPOSE DATA LOGGER
INTECH INSTRUMENTS
GP-MC Multi Purpose Data Logger
The GP-MC is a high resolution (12 bit) multi purpose data logger with eight analogue and two digital pulse
inputs. It supports an additional 15 channels of input from remote sensors on an RS485 interface. It also
provides a Start on Trigger input and two alarm outputs. The logger also has an integral internal temperature
sensor which can be used to log ambient temperature if desired.
A DLC5USB [USB] or DLC5 [RS232] download cable is required to connect the GP-MC logger to a computer.
www.intech.co.nz/gp-mc
GP-MC
RS485
channel expansion
RPC
To more RPC
(Up to 15 total
channels available)
MODEL
GP-MC
Seahorse
DESCRIPTION
10 Input Multi Purpose Logger.
8 Analogue inputs – individually configurable.
2 Digital pulse input channel.
1,000,000 8 bit samples; 500,000 12 bit samples.
Option IP66 Weatherproof enclosure.
Standard External Sensors & Plug Sets for GP-MC;
Others available - contact Intech.
GP-MC inputs are individually configurable using OmniLog. Each input requires
conditioning using a ‘Probe set’. Probe sets are per input as follows;
mA-MC-PS
5VD-MC-PS
10VD-MC-PS
Pt1000-MC-PS
P###-MC-PS
Flow-MC-PS
ACM-MC-PS
One 4~20mA or 0~20mA input
One 0~5Vdc input
One 0~10Vdc input
Note: Maximum voltage input for the GP-MC is 32Vdc (32VD-MC-PS) - for
voltages >32Vdc use an intermediary transmitter like the PI-D.
Pt1000 temperature probe, Range = -50~130ºC.
(Logger maximum Pt1000 range is -100~400º C)
Pressure probe - available ranges are:
P100-MC-PS = -15~100psi, P250-MC-PS = -15~250psi,
P500-MC-PS = -15~500psi
Coil or open collector
Flow metering off the pump run contact
Note: Please contact Intech for other available ‘probe set’ options.
RS485 expansion Options (15 total channels available)
RPC
SWDL-DLC5USB
SWDL-DLC5
DLC5USB
DLC5
38
Remote Probe Controller (3x Analogue channels, 1x Fast Pulse channel)
OmniLog Software and DLC5USB download cable Kit (USB)
OmniLog Software and DLC5 download cable Kit (RS232)
Spare GP-MC download cable (USB)
Spare GP-MC download cable (RS232)
LCD Series loggers are handheld, high resolution (16 bit) data loggers with a liquid crystal display. The LCD
display allows the convenience of viewing realtime readings without having to connect the logger to a
computer.
The logger has an integral internal temperature sensor which can be used to log ambient temperature separately from the loggers main function if desired.
High accuracy and large storage capacity make the LCD series ideal for most industrial and commercial
applications.LCD series loggers are designed for indoor use (IP40) but can be supplied with an optional IP66
Weather Proof Enclosure for outdoor use.
All TruTrack loggers will connect directly to a modem for remote downloading of data and can also send SMS
messages on an alarm condition.
INTECH INSTRUMENTS
LCD DATA LOGGERS
LCD-Series
Features:
• Temperature can be set to any combination of Point, Average, Maximum & Minimum readings.
• Storage capacity of over 500,000 samples!
• High accuracy 16 Bit.
• 1 to 5 year battery life depending on usage, user replaceable. Data is retained in the event of battery failure.
Battery status monitor on LCD display and in OmniLog software.
• User selectable sampling rate from 1 second to 10 hours in 1 second increments.
• Operating range of -20°C to +70°C (-4°F to +158°F).
• Dimensions = 130mm x 80mm x 30mm.
• Optional IP66 Weatherproof Logger Enclosure available for outdoor use.
• A DLC8USB [USB] or DLC8 [RS232] download cable is required to connect LCD Series loggers to a computer.
www.intech.co.nz/lcd-loggers
MODEL
DESCRIPTION
HT-LCD
Humidity and temperature. Range -30~70°C.
Internal humidity and internal temperature sensor.
±3.0%RH accuracy from 20%RH to 80%RH.
THT-LCD
HT11-Probe
HT15-Probe
Tc-LCD
HHT-03
Pt-LCD
TP-Pt100-LCD
P-LCD
P100-PS
P250-PS
P500-PS
SWDL-DLC8USB
SWDL-DLC8
DLC8USB
DLC8
Humidity and dual temperature. Range -30~70°C. Complete with HT11-Probe.
External humidity with temperature, one internal temperature sensor.
Digital humidity sensor with ±3.0%RH accuracy from 20%RH to 80%RH.
Digital humidity sensor with ±2.0%RH accuracy from 10%RH to 90%RH.
Humidity sensor probe cable length is 1.5m.
Accepts Type J, K, N, R and T thermocouple probes with Universal thermocouple
connector socket. Ranges -250~1760°C. (Does not include probe)
Type K temperature probe for Tc-LCD. Range -30~300°C.
Spear probe 2m pvc cable with handle & mini plug.
Others available, please contact Intech.
External RTD temperature sensor, range -200~600°C. (Does not include probe)
Accepts Pt100, Pt500 and Pt1000 probes.
Pt100 temperature probe for Pt-LCD. Range -100~150°C
4.7 x 100mm SS probe with 2m tefzel cable.
Others available, please contact Intech.
Pressure. (Does not include pressure sensor). Can display the pressure in kPa, Bar
or psi on the LCD screen (more pressure display options are available when using
OmniLog software).
End view of
THT-LCD with
external probe
connected
Pressure sensors available for the P-LCD - 500mm cable length:
Pressure sensor. Range = -15~100psi (Overload 200psi, Burst 500psi).
Pressure sensor. Range = -15~250psi (Overload 500psi, Burst 1250psi).
Pressure sensor. Range = -15~500psi (Overload 1000psi, Burst 2500psi).
All pressure sensors have 1/8 inch NPT thread.
OmniLog Software and DLC8USB download cable Kit (USB)
OmniLog Software and DLC8 download cable Kit (RS232)
Spare LCD Series download cable (USB)
Spare LCD Series download cable (RS232)
Option:
Seahorse
IP66 Weatherproof enclosure for LCD Series logger outdoor use.
39
ENVIROMENTAL MONITORING SYSTEMS
INTECH INSTRUMENTS
Small System
Environmental Monitoring Systems are fully scalable, providing the flexibility of monitoring only the inputs needed
for a given application. The systems use our popular and well tested general purpose data loggers, which means
that inputs other than weather types can be also be logged if desired [E.g. 4~20mA or Voltage signal(s)]!
MODEL
GP-HR-LB
DESCRIPTION
GP-HR in L-Bar with attachment plate and two 50mm U bolts
Options:
add any three of
the following
add any one of
the following
Add download
cable:
SWDL-DLC3USB
SWDL-DLC3
DLC3USB
DLC3
GP-HR-LB with Air Temp and
Humidity sensors in Shield &
Solar Radiation sensor.
add Ground Temp
add Air Temp and Humidity in Shield (Note: counts as two channels)
add Leaf Wetness
add Solar Radiation
add Wind Direction
add 4~20mA input
add Voltage Input
add Windspeed
add Rain Gauge Input
add 1mm Rain Gauge
add 0.2mm Rain Gauge
OmniLog Software and DLC3USB download cable Kit (USB)
OmniLog Software and DLC3 download cable Kit (RS232)
Spare DLC3USB download cable (USB)
Spare DLC3 download cable (RS232)
Additional options:
T-BAR
If you require Wind Speed and Direction, use a T-Bar rather than an L-Bar
<< Please refer to pages 36 & 37 for more information on the GP-HR general purpose data logger.
Medium System
MODEL
GP-MC
DESCRIPTION
10 Input Multi Purpose Logger
Option; IP66 Weatherproof Logger enclosure
add External Socket on Logger enclosure
Options:
add any eight of
the following
add any two of
the following
add Windspeed
add Rain Gauge Input
add 1mm Rain Gauge
add 0.2mm Rain Gauge
add any five of
the following
add Air Temp, Humidity, Pressure in Radiation Shield
add Air Temp, Humidity in Radiation Shield
Mounting
Optional IP66
Logger Enclosure
add Ground Temp
add Air Temp and Humidity in Shield (Note: counts as two channels)
add Leaf Wetness
add Solar Radiation
add Wind Direction
add 4~20mA input
add Voltage Input
Add download
cable:
SWDL-DLC5USB
SWDL-DLC5
DLC5USB
DLC5
add L-Bar with attachment plate and two 50mm U bolts
add T-Bar with attachment plate and two 50mm U bolts
OmniLog Software and DLC5USB download cable Kit (USB)
OmniLog Software and DLC5 download cable Kit (RS232)
Spare GP-MC download cable (USB)
Spare GP-MC download cable (RS232)
<< Please refer to page 38 for more information on the GP-MC multi purpose data logger.
40
Weather Sensor Transmitters are a tool for the observation and recording of meteorological data. The sensors
can monitor air temperature, humidity, light intensity, wind speed and wind direction.
The output signals from the sensors are industrial standard 4~20mA (loop powered). This allows for easy
integration into a SCADA or PLC monitoring system.
Individual Sensors
MODEL
DESCRIPTION
Weather Sensor Transmitters. All with 4~20mA output signal.
Humidity sensor c/w 1.5m cable.
Temperature c/w 1.5m cable. 2 options available:
 HS sensor in Heat shrink pocket.
 SS sensor in Stainless Steel penetration probe.
Light Energy c/w base plate and 10m cable.
Wind speed (3 cup Anemometer) c/w 10m cable (1.5m/sec starting speed).
Wind speed (6 cup Anemometer) c/w 10m cable (0.45m/sec starting speed).
Wind direction c/w 10m cable.
0.2mm Rain Gauge (4~20mA output via included PI-F transmitter).
Atmospheric Pressure.
H-CL
T-CL-HS
T-CL-SS
LE-CL
WS3-CL
WS6-CL
WD-CL
RAIN-CL
LPN-DP-BAR
WS-CL
INTECH INSTRUMENTS
4~20mA WEATHER SENSOR TRANSMITTERS
Wind Speed
(3cup Anemometer)
Mounting Options:
LB
TB
Shield
L-Bar with attachment plate and two 50mm U bolts.
T-Bar with attachment plate and two 50mm U bolts.
Solar Radiation Shield - used for more accurate measurement of
temperature and humidity sensors. (Does not include Sensors).
RAIN-CL
0.2mm Rain Gauge
LE-CL
Solar Radiation Shield
(shown attached to LB L-Bar)
Solar Radiation /
Light Energy
(Pyranometer)
LPN-DP-BAR
WD-CL
Atmospheric
Pressure
Wind Direction
www.intech.co.nz/weather
Note:
The L-Bar and T-Bar mounting arms have an attachment plate with holes that can be used for
mounting to 50mm (2inch) or 25mm (1inch) diameter pipe or bolting to posts or buildings.
The L-Bar and T-Bar are supplied complete with two 50mm (2inch) U bolts.
Fully Mounted Sensors
MODEL
WS3-WD-TB-CL
WS3-WD-LE-TB-CL
DESCRIPTION
Weather Sensor Transmitters. 4~20mA output signals.
Wind speed 3 cup (starting speed = 1.5m/sec), wind
direction, mounted on T-Bar mounting arm c/w 5m cable.
Wind speed 3 cup (starting speed = 1.5m/sec), wind
direction, light energy, mounted on T-Bar mounting arm
c/w 5m cable.
Options:
WS6
THS-CL
LPN-DP-BAR
Fit WS6 (Wind speed 6 cup), instead of WS3 on above
T-Bar options (used for lower starting speed = 0.45m/sec).
Temperature and Humidity, both in Solar Radiation Shield c/w 5m
cable, mounted on the above T-Bar options.
Atmospheric Pressure, mounted on the above T-Bar
options.
WS3-WD-TB-CL
with
THS-CL
41
pH SENSORS
WEDGEWOOD ANALYTICAL
Model 10-General purpose ½” NPT pH sensor
Temperature; -5~80°C.
Pressure;
0~100 psi.
Cable length; 3 metres.
Ref. Cell;
Single junction, KCl/AgCl.
Ref. Junction; Porous teflon.
Applications; Non-toxic solutions e.g. Potable water, cooling towers, fresh/salt water aquariums.
MODEL
DESCRIPTION
M-10
Model 10
M-10-ORP
General purpose ½” NPT pH sensor.
Model 10-ORP
General purpose ½” NPT ORP sensor.
Used for Redox measurement in relatively clean waters.
www.intech.co.nz/m10
Model 11-General purpose ¾” NPT pH sensor
Temperature;
Pressure;
Cable length;
Ref. Cell;
Applications;
0~80°C.
0~100 psi.
3 metres.
Double junction, KNO3 and KCl/AgCl.
High resistance to electrode poisoning solutions.
For both submersible and insertable use in process and waste water.
MODEL
DESCRIPTION
M-11
M-11-Pt100
Model 11
General purpose ¾” NPT pH sensor.
Model 11-Pt100
General purpose ¾” NPT pH sensor.
Includes a Pt100 sensor.
M-11-Pt100-HT Model 11-Pt100-HT General purpose ¾” NPT pH sensor.
High temp. version including a Pt100 sensor.
High temperature;
0~110°C.
High pressure;
0~150 psi.
Do not use where ethers, ketones and most aromatic hydrocarbons are
present.
If these solvents are present use the standard version regardless of the
temperature.
M-11-ORP
Model 11-ORP
General purpose ¾” NPT ORP sensor.
Used for Redox measurement in waste water treatment.
Platinum sensing element.
www.intech.co.nz/m11
NOTE
For alkaline conditions between pH 7~13
use the -HT option.
For conditions above pH 13 contact Intech.
Model 12-General purpose ¾” NPT pH sensor
for flowing, viscous applications
Temperature;
Pressure;
Cable length;
Ref. Cell;
Applications;
0~80°C.
0~100 psi.
3 metres.
Double junction, KNO3 and KCl/AgCl.
High resistance to electrode poisoning solutions.
The concave sensor configuration protects the pH bulb from particulate matte
and provides a cleansing flow without affecting the line pressure characteristics.
Ideal for pipelines with flow velocities greater than 30 cm/sec.
Typical applications include batching and process control in the chemical,
petro-chemical, pulp/paper and electroplating industries.
MODEL
M-12
M-12-Pt100
M-12-Pt100-HT
DESCRIPTION
Model 12
General purpose ¾” NPT pH sensor.
Model 12-Pt100
General purpose ¾” NPT pH sensor.
Includes a Pt100 sensor.
Model 12-Pt100-HT General purpose ¾” NPT pH sensor.
High temp. version including a Pt100 sensor.
High temperature;
0~110°C.
High pressure;
0~150 psi.
Do not use where ethers, ketones and most aromatic hydrocarbons are
present. If these solvents are present use the standard version regardless of
the temperature.
www.intech.co.nz/m12
<< Please refer to page 36 for our pH-HR data logger - ideal for use with these pH probes!
(We recommend the probes that include the -Pt100 option for best possible accuracy with the LPI-pH and pH-HR)
42
pH SENSORS
Temperature;
Pressure;
Cable length;
Ref. Cell;
Applications;
WEDGEWOOD ANALYTICAL
Model 21-General purpose ¾” NPT pH sensor
with long insertion length.
0~80°C.
0~100 psi.
3 metres.
Double junction, KNO3 and KCl/AgCl.
High resistance to electrode poisoning solutions, typically those with cyanide,
ammonia, sulphide and heavy metals in appreciable concentrations.
A combination pH sensor for insertion in tanks and large diameter pipes using
process and waste water.
MODEL
DESCRIPTION
M-21
Model 21
General purpose ¾” NPT pH sensor with long insertion length.
M-21-Pt100
Model 21-Pt100
General purpose ¾” NPT pH sensor with long insertion length.
Includes a Pt100 sensor.
Model 21-Pt100-HT
M-21-Pt100-HT
General purpose ¾” NPT pH sensor with long insertion length.
High temperature version including a Pt100 sensor.
High temperature;
0~110°C.
High pressure;
0~150 psi.
Do not use where ethers, ketones and most aromatic hydrocarbons are
present. If these solvents are present use the standard version regardless
of the temperature.
NOTE
For alkaline conditions between pH 7~13
use the -HT option.
For conditions above pH 13 contact Intech.
www.intech.co.nz/m21
<< Please refer to page 36 for our pH-HR data logger - ideal for use with these pH probes!
(We recommend the probes that include the -Pt100 option for best possible accuracy with the LPI-pH and pH-HR)
•
•
•
•
•
•
•
MODEL
4~20mA loop powered.
LCD display.
2 kV isolation.
0.1% accuracy.
40~200mV output test signal.
LED indication of loop current.
IP67 enclosure.
For Ordering Code &
Specification Refer Web Page:
DESCRIPTION
LPI-pH
pH voltage to DC isolating transmitter with LCD display.
pH milli volt input and Pt100 temperature compensation.
Slope and offset adjustments for on site calibration.
LPI-DO2
DO2 voltage to DC isolating transmitter with LCD display.
0~30 milli volt input.
Range, 0~8.26 ppm oxygen.
Slope and offset adjustments for on site calibration.
0
pH
0
mV at 25°C
+413
ACID
H+
1
2
3
5
6
7
0
pH
www.intech.co.nz/lpi-ph
DO2
www.intech.co.nz/lpi-do2
NEUTRAL
7
4
INTECH INSTRUMENTS
ELECTROCHEMICAL TRANSMITTERS
ALKALINE
OH-
8
9
10
11
14
12
13
14
-413
43
Intech Instruments Ltd
CONDITIONS OF SALE
Note:
1.
These terms and conditions apply to all future transactions between Intech Instruments Limited and you.
Prices: All prices are based on the factory price list as held by Intech at
date of quotation, and also on rates of duty and primage, basic wages,
freight, insurance and foreign exchange fluctuations at date of quotation.
Any increase between the date of quotation and the date of delivery in
direct costs other than the factory price resulting from variation in any of
these factors or any other factor beyond the reasonable control of Intech
shall be payable by the purchaser, provided the Buyer may cancel the
Agreement within 7 days of notice of any increase in price. All prices
quoted unless otherwise specified are in New Zealand dollars.
2.
Validity: Unless previously withdrawn our quotation is open for
acceptance for the period stated therein, or when no period is stated, within 30 days only from the date thereof, and is subject to confirmation by
Intech at the time of such acceptance. The quotation is not deemed to
have been accepted until all information required for indenting or
ordering of items has been received.
3.
Government Approval or Import License: Our quotation is subject to
the availability of any necessary Government Approval or Import
Licences and in the event of such approval or Licence not being
forthcoming after reasonable efforts have been made by Intech, Intech
may at its option determine the contract of sale and neither party shall
have any claim against the other in respect thereof.
4.
Delivery: Where a delivery period is quoted the period will commence
when the purchaser accepts or is deemed to have accepted the
quotation or upon the granting of Government approval or Import
Licence where necessary or (where requested by Intech) upon receipt by
Intech of all necessary information and drawings to enable the work to be
put in hand whichever is the later. In no circumstances shall Intech be
liable for late delivery by reasons of fire, strike, stoppages of work, war,
Government action, transport delays, acts of God, shortages of supplies or
manufacturers delays or any other cause whatsoever beyond Intech’s
control. Delivery shall be deemed to be made to the Buyer when the
goods are despatched from Intech’s premises or at the time when the
Buyer is advised of the availability of the goods for dispatch in the event of
the Buyer being unable to take delivery immediately. Where the goods
are to be supplied and installed by Intech, delivery shall be deemed to be
made when the goods are supplied and delivered to the Buyer’s premises.
Where it is agreed that the goods may be delivered by instalments each
delivery is to be regarded as a separate contract and price payable accordingly. Failure of the Buyer to pay for one or more instalments of
goods on due dates shall entitle Intech at its option to: a) suspend further
deliveries pending payment; and or b) treat the agreement as repudiated
by the Buyer.
5.
Passing of Risk: Risk passes from Intech to Buyer on delivery from
which time the goods shall be at the sole risk of the Buyer
notwithstanding that payment for such goods may be payable in whole or
in part at a later date.
6.
Property in the goods: Until payment of the whole of the purchase, the
property of the goods shall not pass to the Buyer not withstanding that the
risk has passed to the Buyer on delivery as aforesaid. Pending full payment, the Buyer agrees to hold the equipment as bailee and in
default of payment on the due date of any instalment to return goods in
good order and condition to the company.
7.
Insurance and Transportation: All insurance and transportation charges after delivery are the responsibility of the Buyer. Where
requested, Intech will arrange transport and insurance for the goods on
behalf of the Buyer and the cost thereof shall be paid by the Buyer
8.
Damage, etc: Inspection of the goods shall be made by the Buyer
immediately upon delivery and in the event of damage, incorrect
execution or shortage, the Buyer shall notify Intech in writing within 3
days of receipt of goods, and shall similarly notify the carrier in the case
of damage or shortage of goods. Intech shall not be liable in respect of
damage or shortage caused in transit, but any insurance arranged as in
clause 7 hereof shall be applicable. The Buyer shall afford Intech the
opportunity to inspect the goods within a reasonable time following
notice and before any use is made. If the Buyer fails to comply with the
provisions the goods are conclusively presumed in accordance with the
agreement and free of any defect/damage apparent on reasonable
examination and the Buyer has deemed to have accepted them.
9.
Payment: Payment must be tendered to Intech in New Zealand
currency at the registered office of Intech by the 20th of the month
following the month in which the goods were despatched. Unless stated
to the contrary Intech reserves the right to charge interest at 10% per
annum on overdue accounts.
10.
Guarantee: Equipment supplied by Intech Instruments Ltd, unless
otherwise stated, is guaranteed against faulty workmanship and
material for twelve months from the date of dispatch from Intech’s
premises. Intech’s responsibility is limited to the replacement of
defective parts whether the work is carried out on site or at Intech’s
premises. Equipment may be repaired under guarantee on site or at
Intech’s premises providing the equipment is returned to Intech freight
paid. If the repairs are carried out on site travelling and accommodation
costs may be charged at ruling rates. Should Intech be called upon to
carry out work under guarantee and find that the fault is not due to faulty
workmanship or materials on Intech’s part then any costs involved will
be added to the contract price and charged accordingly.
11.
Limitation of Liability: Intech’s liability to you is strictly limited to its
obligations under the guarantee. Intech accepts no responsibility for any
other damage loss or losses arising from or in any way connected with
the goods supplied or services provided whether directly or
indirectly and whether by way of consequential loss or otherwise
howsoever. If despite the exclusions of liability in this clause Intech is
found to be liable to you, the liability shall be limited to the value of the
goods or services supplied by Intech to which the claim relates.
12.
Errors: Quotations are subject to correction by Intech for omissions and
typing errors.
13.
Definition: Wherever the word “Intech” is used it shall be deemed to
extend to and include Intech Instruments Limited or its successor or
assign.
Due to on going research and development, designs, specifications, and documentation are subject to change without notification.
No liability will be accepted for errors, omissions, or amendments to specifications.
Prices are standard packaging and ex Intech’s store, freight is an additional charge.
Temperature probes do not have a warranty.
Intech Instruments Ltd
Office Location:
59 Mandeville Street
Riccarton
Christchurch 8011
New Zealand
Postal Address:
PO Box 8568
Riccarton
Christchurch 8440
New Zealand
VISIT OUR WEBSITE
44
Phone
Fax
Email
+64 3 343-0646
+64 3 343-0649
export@intech.co.nz
www.intech.co.nz
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF