Hand-held instruments

Hand-held instruments
JJ Series MH
JJ Series IR
Hand-held instruments

Including products with:
DS_Hand-held_instruments 01/2015
121
Hand-held instruments
Series MH - for humidity, temperature and pressure
The handy and reliable instruments of the MH range are used
for measuring and recording humidity, temperature or pressure.
The MH range is very flexible and is equally suitable for simple
measurements and special applications.
Sensors and probes
The high accuracy of the signal detection and processing
is achieved by means of powerful sensors with electronic
linearisation of the characteristic curve. The correct probes are
available for a wide range of measuring tasks.
Operating comfort
The innovative design of the attractive housing and the advanced
technology make the sensors comfortable to operate. In mobile
use, all functions can be selected and carried out easily by
pressing the buttons. The membrane keypad guarantees
protection against dust and moisture.
Multi-function display
As well as MIN / MAX values, hold function and the selected
unit of measurement, various calculation values, such as
temperature differential, pressure differential, dew point or
heat capacity can also be shown on the multi-function display.
Explosion protection
Hand-held pressure measuring devices and pressure sensors
are available in EXI versions (EEx ib IIC T4-03ATEX0136X).
Inputs
122
Automatic sensor recognition through standard DIN socket
provides a plug-&-play solution that is easy to install.
PC Interface
To transfer the measurement values and stored values to a
PC, the majority of the MH instruments are fitted with a serial
interface.
Outputs
The EBS 20 M software packages are available with extensive
Extensive alarm functions via the display and buzzer, freely
recorder and display functions, as is the SOFT 3050 for evaluation
scalable standard signal output and PC interface are available.
of the logged and alarm values. Process sequences can then
Data storage (Log functions)
Some instruments in the MH range can store data. The
be monitored and analysed clearly using the measurement
procedures recorded and visualised as well as all data can be
exported into standard programs e.g. Excel.
integrated memory records up to 16 200 measurement values.
The date and time is automatically added to the values. A real
Alarm- & time displays
time clock is integrated for this purpose.
A visual and acoustic warning signal indicates when
Two log functions are available:
•• In the STORE mode, data is transferred by means of pressing
measurements exceed or fall below a programmed alarm point.
Transmission via PC is also possible. All data can be displayed
with the year and date, thanks to the real time clock.
a button and 99 records can be stored. The values stored are
shown directly on the display.
•• In CYCLE operation, values are recorded automatically at
a pre-programmed interval. Up to 16 200 records can be
stored. The stored values are shown on a PC.
123
-123-
Hand-held instruments for temperature
MH 3710 and MH 3750
MH 3710
Digital universal temperature hand-held instrument
Type MH 3750
For use with Pt100 exchangeable sensors
•• Inputs
1 x mini-DIN-socket for Pt100 / 4-wire
•• Measuring ranges /resolution
-199.99...199.99 °C / 0,01 °C
200.0...850.0 °C / 0.1 °C
•• Accuracy
±0.015 % full scale ±1 digit
•• Units
°C and °F
•• Outputs
Analogue output 0...1 V
Scalable for easy data readout
•• PC-Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
Temperature hand-held sensors for MH 3710 and MH 3750
Pt100
Name
Temperature range
L
D
Standard sensor
Fig.1
GTF401
-50...400 °C
150 mm
3 mm
Spike sensor
Fig.2
GES401
-50...400 °C
150 mm
3 mm
Surface sensor
Fig.3
GOF401
-50...400 °C
300 mm
3 mm (head = 4 mm)
Air / gas sensor
Fig.6
GLF401
-50...400 °C
100 mm
3 mm (head = 6 mm)
124
Fig. on Page 131
MH 3750
•• Data storage (Log function)
Same as MH 3710
STORE
Additional logger-, alarm- and clock functions
99 data sets (temp1, time and date)
User-specific sensor linearisation
Manual data set reading via keystroke
•• Alarm and time display
CYCLE
Min-max alarm signal via display, interface and buzzer
Real time clock with date and year indication
16 200 data sets (temp1)
Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minutes
For applications that require a very high degree of
accuracy which is higher than the accuracy of the
sensor itself, it is recommended that the sensor be
calibrated to the MH 3750 by means of a user-defined
characteristic curve. In this way, you can meet the
highest accuracy requirements in the range ≤ 0.05 °C.
User-defined characteristic curve
With this function, customer-specific curves can be used,
Class B ± (0.3 + 0.005 |T|)
Class A ± (0.15 + 0.002 |T|)
Linearisation MH 3750
alongside the standard calculation of the resistance /
temperature characteristic curve in compliance with EN 60751.
The MH 3750 has a very high accuracy of measurement. In order
1.2
to be able to exploit this high degree of accuracy, appropriate
1
high-quality temperature sensors must be used. Various
For applications that require a very high degree of accuracy
which is higher than the accuracy of the sensor itself, it is
recommended that the sensor be calibrated to the MH 3750 by
means of a user-defined characteristic curve.
0.8
Accuracy [°C]
standard classes of accuracy are available for this purpose.
0.6
0.4
0.3
0.15
0.2
0.05
0
-50
0
50
100
150
Temperature [°C]
125
MH 1150 and MH 1170
MH 1150
Type MH 1150
Digital temperature hand-held instrument
For use with NiCr-Ni-exchangeable sensors
•• Inputs
1 x mini-TC-socket for thermocouple Type K
•• Measuring ranges / Resolution
NiCr-Ni -50...1150 °C / 1 °C
•• Accuracy
±1 % of rdg. ±1 digit
•• Units
°C
MH 1170
Same as MH 1150
Extended resolution and accuracy
•• Measuring ranges / resolution
Type MH 1170
Selectable resolution 0.1 °C or 1 °C
NiCr-Ni -65...199.9 °C or -65...1150 °C
•• Accuracy
±0.05 % of rdg. ±0.2 % full scale ±1 digit
•• Units
°C and °F
Temperature hand-held sensors for MH 1150, MH 1170, MH 3210, MH 3230 and MH 3250
Typ K
Fig. Page 131
Name
Temperature range
L
D
Standard sensor
Fig.1
GTF900
-65...1000 °C
130 mm
3 mm
Fast response sensor
Fig.1
GTF400
-65...550 °C
130 mm
1.5 mm
Spike sensor
Fig.2
GES900
-65...1000 °C
100 mm
3 mm
Inconel sensor
Fig.2
GTF1200 / 300
-200...1150 °C
300 mm
3 mm
Surface sensor
Fig.4
GOF130CU
-65...500 °C
130 mm
3 mm (head = 4 mm)
Surface sensor
Fig.5
GOF130
-65...900 °C
130 mm
8 mm
Surface sensor
Fig.7
GOF400VE
-65...400 °C
100 mm
6 mm (head = 17 mm)
Surface sensor
Fig.8
GOF400HO
-65...400 °C
130 / 60 mm
6 mm (head = 17 mm)
Air / gas sensor
Fig.6
GLF900
-65...600 °C
130 mm
3 mm (head = 6 mm)
126
MH 3210, MH 3230 and MH 3250
MH 3210
Type MH 3250
Digital universal temperature hand-held instrument
For use with thermocouple exchangeable sensors
•• Inputs
1 x mini-TC-socket for thermocouples K / J / S / T / N
•• Measuring ranges / resolution
Selectable resolution 0.1 °C or 1 °C
Type K
NiCr-Ni -220...1370 °C
Type T
Cu-CuNi -200...1100 °C
Type J
FeCu-Ni -200...1100 °C
Type N
NiCrSi-NiSi -200...1300 °C
Type S
Pt10Rh-Pt -50...1750 °C
•• Accuracy
±0.2 % full scale ±1 digit
•• Units °C and °F
•• Outputs
Analogue output 0...1 V
Scalable for easy data readout
MH 3250
•• PC Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
Same as MH 3230
Additional logger-, alarm- and clock functions
•• Alarm and time display
Min-max alarm signal via display, interface and buzzer
Real time clock with date and year indication
MH 3230
•• Data storage (Log function)
Same as MH 3210
Additional measuring input
STORE
Differential measurement and TARE
99 data sets (temp1, temp2, T2-T1, time and date)
Without analogue output
Manual data set reading via keystroke
•• Inputs
CYCLE
2 x mini-TC-socket for thermocouples K / J / S / T / N
9999 data sets (temp1, temp2, T2-T1)
Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minutes
Temperature hand-held sensors for MH 3210, MH 3230 and MH 3250
Type N
Fig. Page 131
Name
Temperature range
L
D
Standard sensor
Fig.1
GTF101-N250
-50...1300 °C
250 mm
3 mm
127
MH 175
MH 175
Type MH 175
Digital temperature hand-held instrument
For use with Pt1000 exchangeable sensors
•• Inputs
1 x jack-socket for Pt1000 / 2-wire
•• Measuring ranges / resolution -70.0...199.9 °C / 0.1 °C
•• Accuracy ±0.1 % of rdg. ±1 digit
•• Units
°C
Temperature hand-held sensors for MH 175
Pt1000
Fig. Page 131
Name
Temperature range
L
D
Standard sensor
Fig.1
GTF175
-70...200 °C
100 mm
3 mm
Fast response sensor
Fig.1
GTF175-1.6
-70...200 °C
100 mm
1.6 mm
Spike sensor
Fig.2
GES175
-70...200 °C
100 mm
3 mm
Surface sensor
Fig.3
GOF175
-70...200 °C
100 mm
3 mm (head = 4 mm)
Air / gas sensor
Fig.6
GLF175
-70...200 °C
100 mm
3 mm (head = 6 mm)
Cable sensor
Fig.10
GTF2000
-70...200 °C
50 mm
5 mm
Frozen cargo sensor
Fig.9
GGF175
-70...200 °C
100 mm
6 mm
128
Temperature sensors
For temperature hand-held instruments MH-Series
Fig. 1
Fig. 7
Fig. 2
Fig. 8
Fig. 3
Fig. 4
Fig. 9
Fig. 5
Fig. 6
Fig. 10
129
Hand-held instruments for humidity and temperature
MH 3330 and MH 3350
MH 3330
Digital universal humidity / temperature hand-held instrument
Types MH 3330 / 3350 , TFS 0100 E
For use with automatically recognizable exchangeable sensor
TFS 0100 E
•• Inputs
2 x mini-DIN-sockets for capacitive polymer humidity sensor
with Pt1000 temperature sensor 1 x mini-DIN-socket for type K
surface temperature
•• Measuring ranges / resolution
Humidity 0.0...100.0 % r.H. / 0.1 %
Temperature -40.0...120.0 °C / 0.1 °C
Surface temperature
-80.0...250.0 °C / 0.1 °C
•• Accuracy
Humidity ±0.1 % full scale
Temperature ±0.2 % full scale ±1 digit
Surface temperature
±0.5 % of rdg. ±0.5 °C ±1 digit
•• Units
°C, °F, r.H.
•• PC Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
•• Data storage (Log function)
STORE
99 data sets (humidity, temp1, temp2, dew point, dew point
distance, heat content, time, date)
Manual data set reading via keystroke
MH 3350
CYCLE
Same as MH 3330
5400 data sets (humidity, temp1, temp2, dew point, dew
Additional logger-, alarm- and clock functions
point distance, heat content)
•• Alarm and time display
Automatic data set reading in the set interval
Min-max alarm signal via display, interface and buzzer
Adjustable measurement interval 1 sec...60 minutes
Real time clock with date and year indication
Sensor TFS 0100 E
Measuring ranges / resolution
Humidity 0.0...100 % rH / 0.1 % rH
Temperature -40.0...120.0 °C / 0.1 °C
Measuring elements
Humidity capacitive polymer sensor
Temperature Pt 1000 / 2-wire
Accuracy
Humidity ±2 % of rdg.
Temperature 1/3 DIN Pt1000 (±0.1 °C ±0.005 [T])
Electrical connection
PVC cable (1m) with mini-DIN-plug
Tube
Anodized aluminium with plastic sensor head
Dimensions / weight
14 x 120 mm (D x L1) / approx. 110 g
130
Hand-held instruments for pressure
MH 3161 and MH 3181
MH 3161
Digital universal pressure hand-held instrument with internal
Types MH 3161 and MH 3181
piezoresistive pressure sensor for air and non-corrosive /
ionizing gases and fluids
•• Pressure types
Overpressure, negative pressure, differential and absolute
pressure, air pressure/ barometer, vacuum
•• Inputs
2 x metal connection plugs for pressure hose 6 x 1 mm
•• Measuring ranges / resolution
-19999...19999 digit
Type
Measuring range
Over load
Resolution
MH 3161-01
-1...25 mbar (rel.)
100 mbar
(0.01 mbar)
MH 3161-07
-10...350 mbar (rel.)
1 bar
(0.1 mbar)
MH 3161-12
0...1300 mbar (abs.)
4 bar
(1 mbar)
MH 3161-13
-100...2000 mbar (rel.)
4 bar
(1 mbar)
•• Outputs
•• Accuracy
Analogue output 0...1 V
Scalable for easy data readout
±0.2 % full scale (hysteresis and linearity)
•• Units •• Alarm and time display
Min-max alarm signal via display, interface and buzzer
mbar, bar, Pa, kPa, MPa, mmHg, PSI, mH2O
•• PC Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
•• Measuring rate
4 measurements / sec.
Real time clock with date and year indication
•• Data storage (Log function)
STORE
99 data sets (measured value, min / max value, time, date)
Manual data set reading via keystroke
CYCLE
9999 data sets (measured or average value, min / max
value)Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minutes
MH3181
•• Measuring rates
Same as MH 3161
Additional analogue output
SLOW = 4 measurements / sec.
Logger-, alarm- and clock functions
FAST = 100 measurements / sec.
Selectable measuring rate and average calculation
PEAK = 1000 measurements / sec.
Type
Measuring range
Over load
Resolution
MH 3181-01
-1...25 mbar (rel.)
100 mbar
(0.01 mbar)
MH 3181-07
-10...350 mbar (rel.)
1 bar
(0.1 mbar)
MH 3181-12
0...1300 mbar (abs.)
4 bar
(1 mbar)
MH 3181-13
-100...2000 mbar (rel.)
4 bar
(1 mbar)
•• Measuring ranges / resolution
•• Average calculation
Via integration of measurement values at the adjustable
interval
•• Options
higher accuracy sensor (available from 350 mbar) EXI-Version (EEx ib IIC T4 - 03ATEX0136X)
131
MH 3111, MH 3151 and MH 3156
MH 3111
Digital universal pressure hand-held instrument
Types MH 3111, 3151 and 3156
For use with automatically recognizable exchangable sensors MSD
•• Pressure types
Overpressure, negative pressure, differential and absolute
pressure, air pressure / barometer, vacuum (depending on
plugged sensor)
•• Inputs
1 x mini-DIN-socket
•• Measuring range
-19999...19999 digit
•• Accuracy
±0.2 % full scale (hysteresis and linearity)
•• Units
mbar, bar, Pa, kPa, MPa, mmHg, PSI, mH2O
•• PC Interface
Data link with serial PC-Interface
DC-isolated and short-circuit proof
•• Measuring rate
4 measurements / sec.
•• Measuring rates
SLOW
PEAK
MH 3151
Same as MH 3111
Analogue output
Logger function, alarm and real time clock
Switchable measuring rate
•• Outputs
Analogue output 0...1 V
Scalable for easy data readout
•• Alarm and time display
Min-max alarm signal via display, interface and buzzer
Real time clock with date and year indication
•• Data storage (Log function)
STORE
99 data sets (measured value, min / max value, time, date)
Manual data set reading via keystroke
CYCLE
9999 data sets (measured value or average value,
min / max value)
Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minute
132
= 4 measurements / sec.
FAST= 100 measurements / sec.
= 1000 measurements / sec.
•• Average calculation
Via integration of measurement values at the adjustable
interval
MH3156
Same as MH 3151
Additional measuring input
Expand logger function at CYCLE modus
•• Inputs
2 x mini-DIN-socket
•• Data storage (Log function)
CYCLE
4000 data sets (measurement1 or average1, min1 value,
max1 value) (measurement2 or average2, min2 value,
max2 value) (diff M1-M2 or diff AV1-AV2, diff min1-min2,
diff max1-max2) Automatic data set reading in the set interval
Adjustable measurement interval 1 sec...60 minutes
•• Options
Higher accuracy sensor (available from 350 mbar) EXI-Version (EEx ib IIC T4 - 03ATEX0136X)
Pressure sensors MSD
For pressure hand-held instruments MH-Series
Nylon type
Piezoresistive pressure sensor for air as well as non-corrosive /
Types MSD 250 MRE and MSD 160 BRE
ionizing gases and fluids with integrated sensor memory
•• Inputs
2 x nylon connection plugs for pressure hose 6 x 1 mm
•• Accurcy
±0.2 % full scale (hysteresis and linearity)
•• Measuring ranges / resolution
Type (Nylon)
Measuring range
Over load
Resolution
MSD 2.5 MR
-2...2.5 mbar (rel.)
200 mbar
0.001 mbar
MSD 25 MR
-20...25 mbar (rel.)
300 mbar
0.01 mbar
•• Dimensions
MSD 350 MR
-200...350 mbar (rel.)
1 bar
0.1 mbar
MSD 1.3 BA
0...1.3 bar (abs.)
4 bar
1 mbar
•• Weight Approx. 175 g
MSD 2 BA
0...2 bar (abs.)
4 bar
1 mbar
MSD 2 BR
-1...2 bar (rel.)
4 bar
1 mbar
MSD 7 BA
0...7 bar (abs.)
10 bar
10 mbar
MSD 10 BR
-1...10 bar (rel.)
10.5 bar
10 mbar
•• Electrical Connection
PVC cable (1m) with mini-DIN-plug
•• Housing
Robust ABS plastic, Degree of protection IP65
•• Dimensions
70 x 30 x 15 mm (H x D x W)
•• Weight
Approx. 75 g
Stainless steel type
Piezoresistive pressure sensor for aggressive media,
water, gases, and fluids, with internal sensor memory
•• Inputs
Stainless steel connection G½
•• Accuracy
±0.2 % full scale (hysteresis and linearity)
•• Electrical connection (not part of delivery)
PVC cable (1 m) with mini-DIN-plug
•• Housing Stainless steel, Degree of protection IP65
Approx. 23 x 85 mm (Ø x L)
•• Measuring range / Resolution
Type (st. steel)
Measuring ranges
Over load
Resolution
MSD 100 MRE
0...100 mbar (rel.)
1 bar
0.1 mbar
MSD 250 MRE
0...250 mbar (rel.)
2 bar
0.1 mbar
MSD 400 MRE
0...400 mbar (rel.)
2 bar
0.1 mbar
MSD 1 BAE
0...1 bar (abs.)
5 bar
1 mbar
MSD 1 BRE
0...1 bar (rel.)
5 bar
1 mbar
MSD -1 / 1.5 BRE
-1...1.5 bar (rel.)
10 bar
1 mbar
MSD -1 / 3 BRE
-1...3 bar (rel.)
17 bar
1 mbar
MSD 2.5 BAE
0...2.5 bar (abs.)
10 bar
1 mbar
MSD 2.5 BRE
0...2.5 bar (rel.)
10 bar
1 mbar
MSD 4 BAE
0...4 bar (abs.)
17 bar
1 mbar
MSD 4 BRE
0...4 bar (rel.)
17 bar
1 mbar
MSD 6 BAE
0...6 bar (abs.)
35 bar
1 mbar
MSD 6 BRE
0...6 bar (rel.)
35 bar
1 mbar
MSD 10 BAE
0...10 bar (abs.)
35 bar
10 mbar
MSD 10 BRE
0...10 bar (rel.)
35 bar
10 mbar
MSD 16 BAE
0...16 bar (abs.)
80 bar
10 mbar
MSD 25 BAE
0...25 bar (abs.)
50 bar
10 mbar
MSD 25 BRE
0...25 bar (rel.)
50 bar
10 mbar
MSD 40 BRE
0...40 bar (rel.)
80 bar
10 mbar
MSD 60 BRE
0...60 bar (rel.)
120 bar
10 mbar
MSD 100 BRE
0...100 bar (rel.)
200 bar
0.1 bar
MSD 160 BRE
0...160 bar (rel.)
320 bar
0.1 bar
MSD 250 BRE
0...250 bar (rel.)
500 bar
0.1 bar
MSD 400 BRE
0...400 bar (rel.)
800 bar
0.1 bar
MSD 600 BRE
0...600 bar (rel.)
1200 bar
0.1 bar
MSD 1000 BRE
0...1000 bar (rel.)
1500 bar
1 bar
•• Options for nylon and stainless steel
Higher accuracy sensor (available from 350 mbar)
EXI-Version (EEx ib IIC T4 - 03ATEX0136X)
133
Accessories
Software
Nearly all instruments in the MH range are fitted with a PC
interface, so that the values measured and stored can be
transferred and recorded onto a PC. Using the software and
an interface converter, a cost-effective measurement data
recording system can be easily constructed. The EBS 20 M
software packages with extensive recording and display
functions are available, as is SOFT 3050 for evaluation of
the logged and alarm values. Process sequences can then
be monitored and analysed clearly using the measurement
procedures recorded and visualised.
Battery / mains and charger
•• Regulated plug adapter
•• NiCd battery, rechargeable
•• Charger for NiCd battery
Service and carrying case / service bag
Hard shell case in various sizes with packing foam and click lock:
•• Standard (275 x 229 x 83 mm)
WINDOWS PC-software
With a convenient measurement data recording system, recorder,
large display, data display for a maximum of 20 measuring
channels and graphic presentation of measurement values:
•• Adjustable time and measurement value axis
•• Adjustable starting and stopping conditions
•• Individual labelling of axis
•• Adjustable line thickness and colour
•• Adjustable labelling of the measurement points
•• Ddigital display of measurement values across the whole
screen
•• Transfer, recording and archiving of the measurement values
•• Adjustable sampling rate
•• Large comment field
•• Data storage as ASCII code
•• Language: German or English can be selected
Interface converter
•• Data connection with serial PC interface
•• Electrically isolated and protected against short-circuits
•• Connection to PC via 9-pin sub-D socket or USB plug
•• Power supply directly via PC
134
•• Large (394 x 294 x 106 mm)
•• Service bag with nylon sensor cover
Certificates
To confirm the outstanding accuracy for applications in the
service sector, measurement and control workshops and in
quality assurance, works or DAkkS certificates are available to
you from our DAkkS laboratory.
Dr. Siebert & Kühn
.
akkreditiert dur
Struthweg 7-9
34260 Kaufungen
Germany
ch die / accredit
Deutsche Akkre
als Kalibrierlab
Humidity/temperature certificates
Kalibrierschein
Calibration certif
•• Works test certificate 9 measurement points with 20 %,
40 %, 60 %, 80 % (rising / falling) and room temperature
Gegenstand
Object
Hersteller
Manufacturer
Typ
Type
•• DAkkS certificate on request
ed by the
ditierungsstel
oratorium im /
Deutschen Kal
le GmbH
as calibration labo
ratory in the
ibrierdienst
000271
icate
Kalibrierzeichen
Calibration mark
Mikrokalibrier
bad
Micro calibration
bath
Dr. Siebert & Kühn
GmbH & Co. KG
34260 Kaufungen
TP3M165E
Fabrikat/Serien
Serial number -Nr.
Auftraggeber
Customer
1411861
Mustermann AG
Mustergass 1
12345 Mustersta
dt
Auftragsnumme
r
Order No.
Anzahl der Seite
Number of page n des Kalibrierscheines
s of the certificate
Datum der Kalib
rierung
Date of calibration
ll
Prüfprotoko
nstand
Kalibriergege
ct
Calibration obje
/ Test Certificate
endeten
rierung verw
Die für die Kalib n werden regelmäßig
unge
ar auf die
Messeinricht
sind rückführb ikalisch
kalibriert und
ale der Phys
Norm
n
nale
(PTB)
natio
Bundesanstalt nationale
re
Technischen
s oder auf ande ang erstellte
Deutschland
Alle
für diesen Vorg
Normale. Die kann eingesehen werden.
n
auf der(n)
Dokumentatio
sdaten sind
Mes
chen
es
erforderli
Seite(n) dies
nachfolgenden aufgelistet. Dieses
ns
und
ig
Kalibrierschei
tänd
üge
darf nur volls
t werden. Ausz g
Prüfprotokoll
igun
weiterverbreite
der Genehm
unverändert
en bedürfen
ohne
oder Änderung
Prüfprotokolle
nden Stelle.
der ausstelle
haben keine
und Stempel
Unterschrift
Gültigkeit.
n are
for calibratio
g devices used
able to the
The measurin
rated and trace ikalisch
regularly calib
Phys
dards of the
) or other
national stan
(PTB
stalt
for
Bundesan
ments created
Technische
dards. The docufor viewing. All the
national stan
the
e are available
be found on
this procedur
sured data can
ficate.
necessary mea of this calibration certi
(s)
d
page
duce
repro
wing
be
follo
n of
ficate may not
the permissio
This test certi
full except with
ut
other than in
ficates witho
e. Test certi
the issuing offic
valid.
seal are not
signature and
tor
Mikrobadkalibra
Temperatur- idbath Calibrator
perature Liqu
Tem
bH
ert & Kühn Gm
SIKA Dr. Sieb en
34260 Kaufung
Hersteller
Manufacturer
& Co. KG
TPM165S
°C
-35°C / 165
Typ
Type
rien-Nr.
Fabrikat/Se
Serial number
Auftraggeb
er
Customer
ines
Kalibriersche
Seiten des
Anzahl der s of the certificate
ber of page
Num
Datum der
Kalibrierung
2
Dez 2014
ration
Date of calib
GmbH & Co. KG
100 741 854
4
2014-11-30
D-K19636-01-00
2014-11
Dieser Kalibriersc
hein dokument
iert die Rückführung auf natio
nale Normale
zur
der Einheiten
in Übereinstimmu Darstellung
Internationalen
ng mit dem
Einheitensystem
(SI).
Die DAkkS ist
Unterzeichner
der multilatera
Übereinkomme
len
n der European
co-operation for
Accreditation (EA)
und der Internatio
tory Accreditati
nal Laboraon Cooperatio
n (ILAC) zur
genseitigen Aner
gekennung der Kalib
Für die Einhaltung
rierscheine.
einer angemess
Wiederholung
enen Frist zur
der Kalibrierung
ist der Benutzer
verantwortlich.
This calibration
certificate docu
traceability to
ments the
national stand
ards, which realiz
the units of
e
meas
International Syste urement according to the
m of Units (SI).
The DAkkS is
signatory to
the multilatera
agreements of
l
the European
co-operation for
Accreditation
(EA) and of
the Internation
Laboratory Accre
al
ditation Cooperatio
the mutual recog
n (ILAC) for
nition of calibr
ation certificates.
The user is oblig
ed to have the
brated at appro
object recalipriate intervals.
Dieser Kalibriersc
hein darf nur
vollständig und
Genehmigung
unverändert weite
sowohl der
Deutschen Akkre
rverbreitet werd
Kalibrierscheine
ditierungsstelle
en. Auszüge oder
ohne Unterschr
GmbH als auch
ift haben keine
Änderungen bedü
This calibration
Gültigkeit.
des ausstellen
rfen der
certificate may
den Kalibrierla
not be reproduced
Akkreditierungss
boratoriums.
telle GmbH and
other than in
the issuing labor
full except with
atory. Calibration
the permission
certificates witho
of both the Deuts
ut signature are
Datum
che
not valid.
Stellv. Leiter des
Date
Kalibrierlaborat
oriums
Assistant Head
Bearbeiter
of the calibration
laboratory
Person in charg
e
2014-11-30
Dr. Siebert & Kühn
Olaf Schilling
GmbH & Co. KG
* Strut
Olaf Schilling
hweg 7-9 * D-34
260 Kaufungen
* Telefon: 0 56
05/ 8 03 - 0 * Fax:
0 56 05/ 803 -
54/ 60
Temperature certificates
•• Works test certificate 4 measurement points up to 650 °C
•• DAkkS certificate 4 measurement points up to 500 °C
Pressure certificates
re
Um
dingungen
gebungsbe
itions
Ambient cond
Normale
Verwendete
s
Used standard
chgeführt mit
Abgleich dur ed out with
Adjustement
carri
eratu
ratur/ Amb. temp
Raumtempe
idity
hte/ Rel. air hum
Rel. Luftfeuc
. pressure
Luftdruck/ Amb
(23 ± 2) °C
(50 ± 20) %
r
(990 ± 30) mba
/ 2012-09
-17734-01-00
-02, 3730 D-K 9 DKD-K-13901/ 2013-10
Pt100, SN ASL
, 024
,SN 596023
DMM Keithley
•• Works test certificate 10 measurement points
•• DAkkS certificate 10 measurement points
insatz
cSt Bechere
Silikonöl 10 tub insert
onoil 10 cSt
Silic
y
en • German
60 Kaufung
eg 7-9 • 342
A.net
KG • Struthw
.net • www.SIK
GmbH & Co.
• info@SIKA
ert & Kühn
5605-803-54
Sieb
+49
Dr.
A
Fax
•
SIK
5605-803-0
Phone +49
135
Our products at a glance
Series MH
Temperature
MH 3710
MH 3750
MH 1150
MH 1170
MH 3210
MH 3230
Measuring input
Pt100
TC-K
TC-K
TC-K / J / S / T / N
Measuring ranges
-199.99…199.99 °C
200.0…850.0 °C
-50...1150 °C
-65...199.9 °C
200...1150 °C
-199.9…199.9 °C
200...1750 °C
0.01°C / 0.1 °C autorange
1 °C
0.1°C / 1 °C
0.1°C / 1 °C
Units
°C / °F
°C
°C / °F
°C / °F
Display
2 x 4½ digit
3½ digit
3½ digit
2 x 4½ digit
Linearisation
Offset / slope
Offset / slope
Offset / slope
Offset / slope
Offset
Inputs
1
1
1
1
Analogue output


Resolution
Logger function
PC-Interface
1
2
2



MH 3250





Alarm function
(buzzer)


Clock / date
(real time)


Sensor specific
linearisation

EXI-Version
Auto-off function






Min-max-value






Hold-function









Correction value
for surface
measurement
Differential
pressure
Tare-function
Sea-levelcorrection (abs.)
Extended
measurement
functions
136
•• Differential
measurement
•• Difference function
Temperature
Humidity/Temperature
Pressure
MH 175
MH 3330
MH 3161
Pt1000
Capacitive polymer sensor /
Pt1000 / TC-K
Internal sensor
External sensor
-70.0…199.9 °C
0…100.0 % rH
-40.0…120.0 °C / -80.0…250 °C
-1...2000 mbar
Depending on the chosen sensor MSD
0.1 °C
0.1 % rH / 0.1 °C
0.01 mbar
0.001 mbar...10 mbar, depending on
the chosen sensor MSD
°C
% rH / °C / °F
Mbar / bar / kPa / MPa / mmHg / PSI / mH2O
3½ digit
2 x 4½ digit
2 x 4½ digit
Offset / slope
Offset
Offset / slope
1
2
MH 3350
2
2





MH 3181
MH 3111
MH 3151
MH 3156
Offset / slope
1
2

2














1







































•• Dew point
•• Average value
•• Average value
•• Dew point distance
•• Fast / PEAK / SLOW
•• Fast / PEAK / SLOW
•• Heat content
137
Infrared-temperature hand-held measuring instruments
Series IR
When it comes to temperature measurement technique and provided that a combination of simplest control and high measurement
accuracy is required, then infrared thermometers will always be the first choice. This choice becomes a must, if one of the following
requirements are given:
•• Deterioration-free measurement of moving components
•• Measurement of dangerous matter e.g. electrically life parts, chemically aggressive materials etc.
•• Measurement in inaccessible locations
•• Feedback-free measurement of small low-mass components
Without infrared-thermometers are these measurements
almost unthinkable.
In this case, nothing is easier as operation according to the
motto: targeting – measuring – reading the measurement value.
In any area of non contact temperature measurement, SIKA
infrared thermometers are reliable partners due to the following
features: fully developed laser sight technology, very good
optical characteristics, and modern technology with adjustable
emissivity, data memory, and numerous additional functions.
Software
To create a high-performance temperature recording and
monitoring system, you only need the SIKA software package
and a PC. Temperatures measured by MaxiTemp 570 are
transferred to the PC via USB-Connection, where data are
monitored and evaluated graphically or tabular in form of a
company-specific test protocol.
Another highlight of the software package is the userspecific setting of the MaxiTemp-measurement data memory.
You can program the alarm limit values, the emissivity, the
material, and the number of measurement locations for every
measurement point. Continuous measurement value recording
and determination of temperature for preventive maintenance
becomes an easy task with MaxiTemp, PC and software.
138
Measuring spots
Hand-held infrared measuring instruments measure the
To measure a temperature, the hand-held measuring
surface temperature of an opaque object.
instrument is simply aimed at an object and the measurement
The instrument‘s optics detect emitted, reflected, and
activated. Here, the distance and associated spot size is to be
transmitted energy, which is collected and focused onto a
observed.
detector.
The measuring spot size increases as the distance from the
The electronics translate this information into a temperature
object to be measured increases. The ratio between distance
measurement and display the temperature. The laser pointer is
and measuring spot size is represented as optical resolution.
only used as an pointing device.
The higher the optical resolution, the smaller the measuring
spot size is with the same distance.
Very good
Good
Wrong
Sensor
Measurement object larger
Measurment object
than measuring spot
and measuring spot
Measurement object smaller
equal in size
than measuring spot
Table of total Emissivity
To ensure a correct setting of the emission factor in the infrared
temperature measurement, please visit emissivity.sika.net and
download a table of total Emissivity.
139
MiniTemp 400
Technical data
•• Temperature range -20...330 °C
Type MiniTemp 400
•• Resolution 0.1
•• Accuracy < 500 °C: ±(2 % of rdg. + 2 °C)
•• Optical resolution 8 / 1
•• Emissivity fix 0.95
Functions
Spectral range
8…14 µm
Laser pointer
1
Alarm
TC connection
Data Store
PC connection
Power supply
9V
LCD lightning

°C / °F switchable

Bargraph display
Scan / Hold / Auto OFF

Permanent measuring (Lock)
Low Bat. indication

MIN / MAX store

AVA / DIF function
Accessories (incl.)
Battery
Order code
MiniTemp 400
140
EME8ETIR400000
Measuring points
Distance
Size measuring points
200 mm
25 mm
400 mm
50 mm
800 mm
100 mm
SemiTemp 509
Technical data
•• Temperature range -20...510 °C
Type SemiTemp 509
•• Resolution 0.1
•• Accuracy < 500 °C: ±(2 % of rdg. + 2 °C)
> 500 °C: ±(3 % of rdg. + 1 °C)
•• Optical resolution 12 / 1
•• Emissivity 0.10...1.00
Functions
Spectral range
8…14 µm
Laser pointer
2
Alarm
Acustical high / low
TC connection
Data Store
PC connection
Power supply
9V
LCD lightning

°C / °F switchable

Bargraph display
Scan / Hold / Auto OFF

Permanent measuring (Lock)

Low Bat. indication

MIN / MAX store
Max
Measuring points
Distance
Size measuring points
150 mm
12,5 mm
300 mm
25 mm
610 mm
50 mm
AVA / DIF function
Accessories (incl.)
Battery
Order code
SemiTemp 509
EME8ETIR509000
141
SemiTemp 515
Technical data
•• Temperature range -35...800 °C
Type SemiTemp 515
•• Resolution 0.1
•• Accuracy <500 °C: ±(2 % of rdg. + 2 °C)
>500 °C: ±(3 % of rdg. + 1 °C)
•• Optical Resolution 12 / 1
•• Emissivity adjustable 0.10...1.00
Functions
Spectral range
8…14 µm
Laser pointer
1
Alarm
Acustical high / low
TC connection
Type K
Data Store
PC connection
Power supply
9V
LCD lightning

°C / °F switchable

Measuring points
Bargraph display
Distance
Size measuring points
Scan / Hold / Auto OFF

260 mm
20 mm
Permanent measuring (lock)

520 mm
40 mm
Low Bat. indication

1040 mm
80 mm
MIN / MAX store

AVA / DIF function

Accessories (incl.)
Battery, TC-K
Order code
SemiTemp 515
142
EME8ETIR515000
SemiTemp 512
Technical data
•• Temperature range -35...1000 °C
Type SemiTemp 512
•• Resolution 0.1
•• Accuracy < 500 °C: ±(2 % of rdg. + 2 °C)
> 500 °C: ±(3 % of rdg. + 1 °C)
•• Optical Resolution 30 / 1
•• Emissivity adjustable 0.10...1.00
Functions
Spectral range
8…14 µm
Laser pointer
2
Alarm
Acustical high / low
TC connection
Data Store
PC connection
Power supply
9V
LCD lightning

°C / °F switchable

Bargraph display
Scan / Hold / Auto OFF

Permanent measuring (lock)

Low Bat. indication

MIN / MAX store
Max
Measuring points
Distance
Size measuring points
150 mm
12,5 mm
300 mm
25 mm
610 mm
50 mm
AVA / DIF function
Accessories (incl.)
Battery
Order code
SemiTemp 512
EME8ETIR512000
143
MaxiTemp 570
Technical data
•• Temperature range -35...1000 °C
Type MaxiTemp 570
•• Resolution 0.1
•• Accuracy < 500 °C: ±(2 % of rdg. + 2 °C)
> 500 °C: ±(3 % of rdg. + 1 °C)
••
Optical Resolution 50 / 1
••
Emissivity adjustable 0.10...1.00
Functions
Spectral range
8…14 µm
Laser pointer
2
Alarm
Acustical (high / low)
TC connection
Type K
Data Store
100
PC connection
USB
Power supply
9V
Measuring points
LCD lightning

Distance
Size measuring points
°C / °F switchable

260 mm
20 mm
Bargraph display

520 mm
40 mm
Scan / Hold / Auto OFF

1040 mm
80 mm
Permanent measuring (lock)

Low Bat. indication

MIN / MAX store

AVA / DIF function

Accessories (incl.)
Battery, TC-K, transport case,
software, USB cabel, standbase
Order code
MaxiTemp 570
144
EME8ETIR570000
Our products at a glance
Series IR
MiniTemp 400
SemiTemp 509
SemiTemp 515
SemiTemp 512
MaxiTemp 570
Temperature range
-20…330 °C
-20…510 °C
-35…800 °C
-35…1000 °C
-35…1000 °C
Resolution
0.1
0.1
0.1
Accuracy
< 500 °C
> 500 °C
±(2 % of rdg. + 2 °C)
±(2 % of rdg. + 2 °C)
±(3 % of rdg. + 1 °C)
±(2 % of rdg. + 2 °C)
±(3 % of rdg.+ 1 °C)
Optical Resolution
8/1
12 / 1
Adjustable 0.10…1.00
Emissivity
Fix 0.95
Spectral range
8…14 μm
Laser pointer
1
Alarm
2
12 / 1
30 / 1
50 / 1
1
2
2
Acustical (high / low)
TC connection
Acustical (high / low)
Type K
Type K
Store
100
PC connection
USB
Power supply
9V
LCD lightning





°C / °F switchable





Bargraph display
Scan / Hold / Auto OFF


Permanent measuring (lock)








Low Bat. indication





MIN / MAX store

Max

Max

AVA / DIF function
Accessories (incl.)

Battery
Battery
Battery, TC-K

Battery
Battery, TC-K, transport case, software,
USB cabel, stand
base
145
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project