UPS System Description
1
Inspection
2
Placement
Remove the UPS from its packaging and inspect it
for damage that may have occurred during shipping.
If any damage is discovered, repack the unit and
return it to the place of purchase.
Modem/Phoneline Connection
Plug incoming internet line into the “In” socket at the
back of the UPS. Use one more Internet line cable
and plug one end of the Internet line cable to the
“Out” socket at the back of the UPS. Plug the other
end to the modem input socket as shown.
3).When in battery mode, it will display as below.
And the mark
will flicker every 1second.
Note: If I/P-V<40V,input voltage will display “000”
Install the UPS unit in any protected environment
that provides adequate airflow around the unit, and
is free from excessive dust, corrosive fumes and
conductive contaminants. Do not operate your UPS
in an environment where the ambient temperature
or humidity is high. On the other hand, place the
UPS unit away from monitor at least 20cm to avoid
interference.
3
5
4).When in off charging mode, it will display as below.
6
Turn On/Off
To turn on the UPS unit, press the power switch lightly.
To turn off the UPS unit, press the power switch again
(When Swith ON,The LED lighting.).
Charging
This unit is shipped from the factory with its internal
battery fully charged. however, some energy may be
lost during shipping so the battery should be
recharged before using it. Plug the unit into an
appropriate power supply and allow the UPS to
charge fully by leaving it plugged in for 8 hours.
Note: the output voltage always is displayed as “000”
in off charging mode.
5).When in fault mode, it will display as below. “FAULT”
character and the reason of fault only.
Note: the fault code will be showed in fault mode.
6).Load level definition:
7
Load LEVEL
LCD Display Specification
Load bar Indication
0%~25%
The LED will always turns on when UPS works,
including in off charging mode and fault mode.
25%~50%
When LCD start to work, it will display all information
for 3s
4
50%~75%
75%~100%
Computer Connection
7).Battery capacity definition:
Connect one computer-related device into each of
the power receptacles supplied on the back of the
UPS (maximum of three devices).
Battery voltage ≤11V
1).When in normal mode, it will display as below.
11V≤Battery voltage ≤11.5V
11.5V≤Battery voltage≤12.5V
Battery voltage ≥12.5V
2).When in AVR mode, it will display as below. And the
mark
will flicker every 1second.
will flicker every
8).When over load, the mark
1second.
9).When battery low, the mark
1second.
will flicker every
UPS System Description
Front Panel—
Back Panel—
1. LCD Back-Light
1. USB Port
1
2. Power “ON/OFF” Switch
2. Modem/Phone Line Surge Protection
1
2
3. Battery Backup Outlets
2
4. Surge protected outlets
OUT
IN
5
6
5. AC input
6. Circuit breakerz
*
LONG
202-719-4978
IEC×3 for 220/230/240V
3
4
2.
Choose the operation system you need and follow the instruction
described on the website to download the software.
3.
When downloading all required files from the internet, enter the serial
No: 511C1-01220-0100-478DF2A to install the software.
When your computer restarts, the WinPower software will appear as a
green plug icon located in the system tray, near the clock.
This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable parts.
Only factory service personnel may perform repairs.
Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery.
Connection to any other type of receptacle other than a two-pole, three-wire grounding receptacle may result in s shock hazard as well
as violate local electrical codes.
In the event of an emergency, turn the power switch to the “off” position and disconnect the power cord form the AC power supply to
Use the table below to solve minor UPS installation or operation
problems. If any abnormal situations occur that are not listed
above,please call service people immediately.
Symptom
the unit.
This unit intended for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants).
Do not attach a power strip or surge suppressor to the UPS.
Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the
unit near heat emitting appliances such as space heaters or furnaces.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Do not dispose of battery or batteries in a fire. The battery may explode.
Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working
on batteries :
1) Remove watches, rings, or other metal objects from the hand.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on the top of batteries.
5) Disconnect charging source prior to connecting or disconnecting batteries terminal.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions.
Keep unauthorized personnel away from batteries.
When replacing batteries, replace with the same number of the sealed lead-acid batteries.
1. Charge battery up to 8
hours.
2. Replace with the same type
of battery.
3. Press the power switch
again or elecerity the Input
cord
3.When the Input cord
isn’t electvified and
Power switch is not
pressed.
Overload of the UPS.
Do not allow any liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near
Do not plug the UPS input into its own output.
Remedy
No LED display on 1. Missing battery.
the front panel.
2. Battery defect.
properly disable the UPS
Avoid installing the UPS in locations where there is standing or running water, or excessive humidity.
Possible Cause
Alarm buzzer
Verify that the load matches
beeps continuously
the UPS capability specified in
when AC supply is
the specs.
normal.
When power
1. Overload of the UPS. 1. Remove some noncritical
failure, back-up
load.
time is shorten.
2. Battery voltage is too 2. Charge battery 8 hours or
low.
more.
3. Battery defect due to 3. Replace with the same type
high temperature
of battery.
operation environment,
or improper operation
to battery.
Communication
1. Software is not
1. Check the setting of the
lost between UPS
installed well.
software .
and computer.
2. Cable is not properly 2. Make sure both ends of the
USB cable is connected
connected.
and recheck settings.
Mains normal but 1. Circuit breaker is
LCD display
broken.
Battery mode.
2. Power cord is loose.
1. Reset the circuit breaker..
2. Reconnect the power cord
properly.
This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen.
During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected
loads does not exceed 3.5mA.
The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible.
MODEL
CAPACITY
INPUT
Software Installation
VA/W
PRO-400A LCD
PRO-600A LCD
PRO-800A LCD
400/240
600/360
800/480
Voltage Range
89-145VAC/162~290VAC
Frequency
50Hz/60Hz (Auto-Sensing)
Voltage
110/120/220/230/240VAC
Voltage Regulation
-- WinPower --
OUTPUT
WinPower is a brand new UPS monitoring software, which provides
BATTERY
Frequency
Regulation
+/-1 Hz(Battery Mode)
12V/4.5Ah
12/7Ah
12V/9Ah
Back up Time
Up to 12 mins
Up to 22 mins
Up to 30 mins
TRANSFER TIME Typical
INDICATOR
Modified Sine-wave
Battery Type
Recharge Time
power failure. With this software, users can monitor and control any UPS
on the same LAN no matter how far from the UPS
50Hz / 60Hz
Output Waveform
user-friendly interface to monitor and control your UPS. This unique
software provides safely auto shutdown for multi-computer systems while
+/- 10%(Battery Mode)
Frequency
LCD Display Models
Backup Mode
8 Hours to 90% after complete discharge
2-6ms typical, 10 ms max
The LCD will always turn on when UPS work,
Including in off charging mode and fault mode
Sounding every 10 seconds
Battery Low
AUDIBLE ALARM Overload
Battery replace
Sounding every 1 second
Sounding every 0.5 seconds
Sounding every 2 seconds
Fault
Buck/boost with
>70% SPS load
PROTECTION
Full Protection
PHYSICAL
Dimension (DxWxH)
WEIGHT
ENVIRONMENT
Installation procedure:
1.
Go to the website:
http://www.ups-software-download.com/winpower.htm
INTERFACE
Net Weight
Continuous sounding
Sounding every 0.5sec. after 25min.
And fault after 30 mins
Discharge,Overcharge short circuit
and Overload Protection
330 x 100 x 140mm/12.9 x 3.9 x5.5 inch
4.4Kg/9.7lb
5.4Kg/11.9lb
6.1Kg/13.4lb
Operating
Environment
0- 40°C, 0-90 % Relative Humidity (non-condensing)
Noise Level
Less than 40dB
USB
(Software included)
For Windows Family, Mac, Linux Family,
and Unix Based Famillies
All trade names are registered trademarks of respective manufacturers listed.
Specifications may change without notification.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising