Model No. MC-CG381-AC79 MC-CG381-AW79 MC-CG381-RW79

Model No. MC-CG381-AC79 MC-CG381-AW79 MC-CG381-RW79
Order No.VCB0803006CE
Vacuum Cleaner
Model No. MC-CG381-AC79
MC-CG381-AW79
MC-CG381-RW79
Product Color :Sporty blue
Sporty blue
Sporty red
Destination
:Europe
(MC-CG381-AC79)
(MC-CG381-AW79)
(MC-CG381-RW79)
TABLE OF CONTENTS
PAGE
Specifications ----------------------------------------------------- 2
Location of Controls and Components ------------------- 3
Troubleshooting Guide ----------------------------------------- 5
Disassembly and Assembly Instructions ---------------- 6
4.1. Dust box cover assembly removal -------------------- 6
4.2. Separate the upper and lower body units ----------- 6
4.3. Removal of the cord reel U------------------------------ 7
4.4. Removal of the P.C.B. ass'y and motor -------------- 8
5 Wiring Connection Diagram ---------------------------------10
6 Exploded View and Replacement Parts List -----------11
6.1. EXPLODED VIEW (ATTACHMENTS) -------------- 11
6.2. PARTS LIST (ATTACHMENTS) ----------------------12
6.3. EXPLODED VIEW (BODY UNIT) --------------------13
6.4. PARTS LIST (BODY UNIT) ----------------------------14
6.5. PACKING INSTRUCTIONS----------------------------15
6.6. PACKING LIST--------------------------------------------16
PAGE
1
2
3
4
© 2008 Matsushita Electric Industrial Co., Ltd. All
rights reserved. Unauthorized copying and distribution is a violation of law.
1 Specifications
Model No.
Power source
Input power (MAX)
Input power (Nominal)
Power control
Extension wand
Dimensions (WxLxH)mm
Net weight
Multipurpose accessory
MC-CG381
230 V~50 Hz
1500 W
1200 W
O
Metal x 2
240x350x250
3.8kg
O
2
2 Location of Controls and Components
3
4
3 Troubleshooting Guide
CONDITION
Motor fails to rotate
(no noise is heard at all)
Motor fails to rotate
(no noise is heard at all)
CHECK POINT
Power supply cord
Fuse of P.C.B. Ass’y
(250V, 10A)
Motor continuity
ON/OFF Switch
Power supply cord
METHOD OF INSPECTION
TRANSACTION
Check power supply cord continu- If there is no continuity, replace the
ity.
cord reel patition unit.
Check fuse continuity.
If there is no continuity, replace
P.C.B. Ass’y.
Check the conduction between the If there is no continuity, replace the
terminals of the motor.
or motor.
Check continuity across switch If there is no continuity, replace
connections
P.C.B. Ass’y.
Check power supply cord continu- If there is no continuity, replace the
ity.
cord reel patition unit.
P.C.B. Ass’y
Motor runs but there is no suction
Noise or vibration
Check the internal parts for anything unusual. (burn-out, meltdown, etc.)
Hose or Suction inlet, Extension Check whether or not the specified
wand and nozzle
components are clogged with foreign substances.
Dust bog / Secondary filter
Check if dust bag is full or Secondary filter is choked up.
Motor fan
P.C.B. ass’y
The motor output cannot be
changed.
(The motor always rotates at full
speed.)
Switch and the limit switch on
The motor output cannot be
the P.C.B. Ass'y
switched.
• The MIN/MAX cannot be
switched.
• The switch cannot be turned on.
• The motor always rotates at the
MIN speed.
If anything is found unusual,
replace the P.C.B. assembly with
new one.
If there is any blockage, remove it.
If dust bag is foll, replace with a
new one. If Secondary filter is
choked up, remove and clean it out
or replace.
Check dust accumulated in motor If there is dust accumulated in the
fan (it could happen if the vacuum motor fan, replace the motor and
cleaner has been used without cen- check filter condition. (never try to
dismantle the motor fan)
tral filter).
Check whether or not T1 and T2 of If they are short-circuited, then
replace the P.C.B. ass'y.
the Triac on the P.C.B. ass'y are
short-circuited.
Verify the conductivity of both
switches.
5
If any of the switches is not conductive, then replace the switch or the
P.C.B. Ass’ y (with a limit switch)
accordingly.
4 Disassembly and Assembly Instructions
Important notice: Before replacing any components, make sure to turn OFF the vacuum cleaner.
Remove the power plug from the outlet.
* Caution:
1. Do not attempt to modify the machine, parts, etc. when marking repairs.
2. Even if a wire is partially disconnected, do not attempt to repair and/or connect it when a wired unit is available as
service parts. Replace the overall section with a new wired unit.
3. Pull out and/or insert the fastening terminal without twisting it.
4.1.
Dust box
removal
cover
assembly
4.2.
1. Insert a flat-blade screwdriver between the dust box lid
and its fitting section on the body and move it in the direction of the arrow to remove the dust box lid from the body.
Separate the upper and lower
body units
1. Set the body sideways and remove the two screws fixing
the upper body U from the bottom.
2. Remove the two screws fixing the upper body.
6
3. Lift the upper body U to separate it from the lower body.
4.3.
2. Lift the cord reel partition ass'y from the lower body.
3. Remove the two lead wires connected to the cord reel
partition ass'y.
a. Remove the terminal connected to the P.C. B. U.
b. First, remove either of the terminals connected to the
switch.
* Caution:
Pull out the fastening terminal without twisting it.
Pull out by holding down the section indicated by
an arrow.
Removal of the cord reel U
1. Remove the potentiometer knob and switch cover U.
7
4.4.
4. Remove the cord reel partition ass'y.
Removal of the P.C.B. ass'y
and motor
1. Remove the motor case U with the motor and the P.C.B.
ass'y fitted from the lower body.
5. Push the brake lever and loosen the spring winding the
cord (loosen the pre-winding).
* Caution for re-assembling: There are four pre-windings.
2. Remove the P.C.B. ass'y from the motor case U.
6. Remove the screw fixing the cord reel U and the body
partition U.
7. Remove the cord reel U.
8
5. Remove the noise supporessor, motor support rubber
(rear), and motor support rubber (front).
3. Remove the motor support front from the motor and then
cut the Wire band fixing the thermal protection device to
remove it.
4. Remove the lead wire, from the P.C.B., connected to the
motor ass'y terminal.
The P.C.B. Ass'y is removed simultaneously.
* Precautions for re-assembly
Tape is pasted on the lead wire terminals of components on the P.C.B. Ass'y.
The tape must not be removed when components are
replaced.
If the tape is removed by mistake, then use tape for
servicing.
Servicing component part number: AMC56L-1800E
Component name: Gasket V