STANDBY 30 kW PRIME 27 kW
X Q 3 0 P 4
STANDBY 30 kW
PRIME
27 kW
60 Hz
Voltage
Standby
kW (kVA)
Prime
kW (kVA)
208/120V
480/277V
240/120V
30 (37.5)
30 (37.5)
26.5 (26.5)
27 (33.8)
27 (33.8)
24 (24)
FEATURES
EPA TIER II & CARB CERTIFIED
FOR NON-ROAD MOBILE
APPLICATIONS
SOUND ATTENUATED
ENCLOSURE
● The fully weatherproof
enclosures incorporate
internally mounted exhaust
silencers and are of extremely
rugged construction in order
to withstand the rough
handling common on many
construction sites. They are
designed on modular
principles with many
interchangeable components
permitting on site repair.
● Highly corrosion resistant
construction.
– Body made from sheet
steel components pretreated with zinc
phosphate prior to
polyester powder coating
at 392°F (200°C)
– Black stainless steel
padlockable latches.
– Zinc die cast hinges/grab
handles.
●
●
●
Excellent access for
maintenance.
– Two large doors on each
side. Two rear doors for
distribution/control panel.
– Front panel for air
discharge box access.
– Lube oil and cooling water
drains piped to exterior of
the enclosure.
Security and safety.
– Safety glass control panel
viewing window in a
lockable access door.
– Emergency stop button
on enclosure exterior.
– Cooling fan and battery
charging alternator fully
guarded.
– Fuel fill and battery can
only be reached through
lockable access doors.
Transportability.
– Tested and certified single
point lifting eye.
– Lifting points on baseframe.
REAR CUSTOMER ACCESS
● Access through two doors.
● Separate control panel
access.
● Separate connection console.
● Hinged door over main
connectors.
● Emergency stop on panel.
ENVIRONMENTALLY
FRIENDLY DESIGN
● EPA Tier II off-highway
compliant engine.
● UL double walled fuel tank
base with 24 hour minimum
fuel supply.
OPTIONS
●
●
●
ROBUST DESIGN FOR RENTAL
ENVIRONMENT
● Packages designed to survive
in rugged and maintenance
starved environment.
●
DISTRIBUTION PANEL
● Switchable voltage from
480/277V 3 Phase to 240/139V
3 Phase (Can be dialled down
to 208/120V 3 Phase) 240/120V
Single Phase.*
●
●
●
AH1L — Anti-Condensation
Heater 110-120 volt AC
WHL — Coolant Heater
110-120 volt AC
LOLR — Lube oil make-up
system with REN automatic
leveller
GOVE5 — Electronic
Governor
PBC3UL — Battery Charger
PSS11 — Raise/Lower
controls on control panel
LUBP2 — Lube oil drain
pump
* Refer to distribution panel
specifications for details.
LEHF4785-01 (02-05)
W H E R E
T H E
W O R L D
T U R N S
F O R
P O W E R
S T A N D B Y
P R I M E
6 0 H z
3 0
2 7
k W
k W
STANDARD FEATURES
1. ENGINE
Perkins Engine Co. heavy duty
industrial EPA compliant diesel engine.
1.1 Governor
Mechanical, compliant with BS5514,
Class A1.
1.2 Electrical System
12 Volt DC. Energized to run shutdown
solenoid. Oil pressure and coolant
temperature/level shutdown switches
and gauge senders.
1.3 Derates
Genset power derates will be
required in accordance with engine
manufacturers above 86°F (30°C).
2. COOLING RADIATOR
Radiator and cooling fan complete
with protection guards, designed
to cool the engine in ambient
temperatures up to 120°F (49°C).
3. ENGINE FILTRATION SYSTEM
Cartridge type dry air filters with
restriction indicator. Racor Fuel Filter in
addition to engine filter. Cartridge type
fuel filters and full flow lube oil filters.
All filters have replaceable elements.
4. EXHAUST SYSTEM
Critical Silencer with flexible connector.
All internal pipework lagged.
5. ELECTRICAL SYSTEM
12 Volt system with battery charging
alternator, and starter motor on
engine, battery rack mounted on the
generator set baseframe and battery
charger mounted on control panel.
Battery rack will accept a variety of
battery sizes.
6. GENERATOR
Screen protected and drip-proof, self
exciting, self-regulating brushless
generator with fully interconnected
damper windings, IC06 cooling system
and sealed-for-life bearings. Switchable
voltage output.
6.1 Insulation System
The insulation system is Class H.
Windings are impregnated in a triple
dip thermo-setting moisture, oil and
acid resisting polyester varnish. Heavy
coat of anti-tracking varnish for
additional protection against moisture
or condensation.
6.2 Electrical Characteristics
Electrical design in accordance with
BS5000 Part 99, IEC60034-1,
EN61000-6, NEMA MG-1.22.
6.3 Automatic Voltage Regulator (AVR)
The fully sealed automatic voltage
regulator maintains the voltage within
the limits of ± 0.5% at steady state
from no load to full load.
Nominal adjustment is by means of
a trimmer incorporated in the AVR.
The panel door incorporates an
additional voltage adjustment
potentiometer.
6.3.1 Permanent Magnet Generator
Providing 350% short circuit
capabilities, enhanced Motor Starting
and non-linear loading performance.
6.4 Waveform Distortion,THF and TIF
Factors
The total distortion of the voltage
waveform with open circuit between
phases or phase and neutral is in the
order of 1.8. On a 3 phase balanced
harmonic-free load the total distortion
is 4%. Machines are designed to have a
THF less than 2% and a TIF less than
50. A 2/3 pitch factor is standard on all
stator windings.
6.5 Radio Interference
Suppression is in line with the
provisions of EN61000-6.
7. MOUNTING ARRANGEMENT
7.1 Baseframe
The complete generator set is mounted
on a heavy duty fabricated steel
baseframe. The baseframe includes
a UL listed closed top fuel tank and
incorporates specially designed
lifting points.
7.2 Coupling
The engine and generator are directly
coupled by means of an SAE flange
so that there is no possibility of
misalignment after prolonged use.
The engine flywheel is flexibly coupled
to the generator rotor and a full
torsional analysis has been carried out
to guarantee no harmful vibration will
occur in the assembly.
7.3 Anti-Vibration Mounting Pads
Captive anti-vibration pads are affixed
between engine/generator feet and
the baseframe ensuring complete
vibration isolation of the rotating
assemblies and enabling the machine
to be placed on an uneven surface
without detrimental effects.
7.4 Safety Guards
The fan, fan drive and battery charging
generator drive are fully guarded for
personnel protection. Heat guards
protect personnel from the exhaust
pipe. All guards are to OSHA standards.
8. FUEL SYSTEM
Fuel feed and return lines to the engine
are terminated at the baseframe
mounted 24 hour extended capacity
fuel tank. The entire fuel system is
surrounded by a catchment area to
prevent leakage. 3-way valves to allow
connection of auxiliary fuel tank.
LEHF4785-01 (02-05)
2
9. CONTROL SYSTEM
9.1 Control Panel
Set mounted autostart panel in a
vibration isolated NEMA 1 sheet steel
enclosure with a hinged lockable door.
a. DC and AC Wiring Looms
DC and AC wiring looms utilizing
industrial type multi-pin connectors
to permit fast fault finding.
9.2 Circuit Breaker,
3 Pole UL CSA listed molded case
circuit breaker mounted on the
generator set in a vibration isolated
NEMA 1 distribution panel.
9.3 Small power receptacles housed
in a NEMA 1 distribution panel.
Receptacles accept industry standard
male plugs. Each receptacle is
protected by a miniature circuit
breaker which also acts as an
On/Off switch.
10. DOCUMENTATION
A full set of operation and maintenance
manuals, circuit wiring diagrams, and
instruction leaflets is provided.
11. SOUND ATTENUATED
ENCLOSURES
A noise reducing enclosure surrounds
the entire generator set. Combined
with a critical engine silencer this
provides an overall noise reduction
from 65 to 68 dBA at 23 feet through
the range.
12. FACTORY TESTS
The generator set is load tested before
dispatch. All protective devices, control
functions and site load conditions are
simulated and the generator and it’s
systems checked, proved and then
passed for dispatch. A test certificate
can be provided upon request.
13. EQUIPMENT FINISH
All sheet metal components including
the enclosure and the base tank are
fully degreased, phosphated and
chromated for anti-corrosive protection
prior to painting with polyester powder.
The powder is cured at a temperature of
392°F (200°C) to ensure maximum scuff
resistance and durability. All fasteners
are electroplated. The engine and
generator are thoroughly cleaned and
finished in temperature controlled
ovens with industrial high gloss
polyurethane paint.
14. STANDARDS
The equipment meets the following
standards: BS4999, BS5000, BS5514,
IEC60034, EN61000-6, NEMA MG-1.22.
15. WARRANTY
Full manufacturer's warranty
S T A N D B Y
P R I M E
6 0 H z
3 0
2 7
k W
k W
XQ30P4
Materials and specifications are subject to change without notice.
Generator Set Technical Data — 1800 rpm/60 Hz
Power Rating
Lubricating System
Type: full pressure
Oil filter: spin-on, full flow
Oil cooler: water cooled
Oil type required: API CF-4
Total oil capacity
Oil pan
Fuel System
Fuel filter type: replaceable element
Recommended fuel: #2 diesel
Generator set fuel consumption
100% load
75% load
50% load
Fuel tank capacity
Engine Electrical System
Voltage/ground: 12/Negative
Battery charging generator ampere rating
Cooling System
Water pump type: centrifugal
Radiator system capacity including engine
Maximum coolant static head
Minimum temperature to engine
Temperature rise across engine
Heat rejected to coolant at rated power
Radiator fan load
Air Requirements
Combustion air flow
Maximum air cleaner restriction
Radiator cooling air
Generator cooling air
Exhaust System
Exhaust backpressure (maximum allowable)
Exhaust flow at rated kW
Exhaust temperature at rated kW — dry exhaust
Generator Set Noise Rating*
[with enclosure at 23 feet (7 meters)]
Standby
Prime
kW (kVA)
30 (37.5)
27 (33.8)
U.S. Gal (L)
U.S. Gal (L)
1.85 (7.0)
1.45 (5.5)
1.85 (7.0)
1.45 (5.5)
G/hr (L/hr)
G/hr (L/hr)
G/hr (L/hr)
U.S. Gal (L)
2.3 (8.9)
1.8 (6.9)
1.4 (5.1)
149 (565)
2.1 (8.1)
1.7 (6.4)
1.3 (4.8)
149 (565)
Amps
45
45
U.S. Gal (L)
Ft H2O (m H2O)
°F (°C)
°F (°C)
Btu/min (kW)
Hp (kW)
3.37 (12.8)
33.5 (10.2)
158 (70)
10.8 (6)
1246 (21.9)
1.34 (1.0)
3.37 (12.8)
33.5 (10.2)
158 (70)
10.8 (6)
1132 (19.9)
1.34 (1.0)
Cfm (m3/min)
In H2O (kPa)
Cfm (m3/min)
Cfm (m3/min)
128 (3.63)
26.5 (6.6)
4280 (121)
382 (10.8)
129 (3.64)
26.5 (6.6)
4280 (121)
382 (10.8)
In Hg (kPa)
Cfm (m3/min)
°F (°C)
4.43 (15.0)
338 (9.58)
1164 (629)
4.43 (15.0)
311 (8.80)
1040 (560)
dBA
65.8
65.4
*dBA levels are for guidance only
SPECIFICATIONS
GENERATOR
ENGINE
Voltage regulation . . . . . . . ± 0.5% at steady state from no load to
full load.
Frequency . . . . . . . . . . . . . . . . . . . . ± 0.25% for constant load from
no load to 100% load
Waveform distortion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . THD <4%
Radio interference . . . . . . . . . . . . . . Compliance with EN61000-6
Telephone interference . . . . . . . . . . . . . . . . . . . . TIF <50, THF <2%
Overspeed limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2250 rpm
Insulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class H
Temperature rise . . . . . . . . . . . . . . . . . . . . . . Within Class H limits
Available voltages: . . Switchable Voltage Output: 480/277 Volt,
240/139 Volt 3 Phase
to 240/120 Volt Single Phase
Deration . . . . . . . . . . . . . . . Consult factory for available outputs
Ratings . . . . . . . . . . . . . . . . . . . . . At 86°F (30°C), 500 ft (152.4 m)
60% humidity, 0.8 pf
Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Perkins
Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1104C-44NA
Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-Cycle
Aspiration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Natural
Cylinder configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . In-line-4
Displacement — cu. in. (L) . . . . . . . . . . . . . . . . . . . . . . . . . 269 (4.4)
Bore — in (mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.13 (105)
Stroke — in (mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.00 (127)
Compression ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19.3:1
Governor
Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical
Class. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISO 8528 G1 & G2
Air cleaner type . . . . . . . . . . . . . Dry, replaceable paper element,
type with restriction indicator
Piston speed — ft/sec (m/sec) . . . . . . . . . . . . . . . . . . . . . 25.0 (7.62)
Engine speed — rpm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
(Figs. are dep. on the Governor class)
G1
G2
*Maximum power at rated rpm — hp (kW)
Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65.6 (49) 72.6 (54.2)
Prime . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58.2 (43.5) 64.9 (48.5)
BMEP — psi (kPa)
Standby . . . . . . . . . . . . . . . . . . . . . . . . . . 108.6 (749) 118.8 (819)
Prime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.5 (638) 108.2 (746)
Regenerative power — kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.7
LEHF4785-01 (02-05)
3
S T A N D B Y
P R I M E
6 0 H z
3 0
2 7
k W
k W
CONTROL PANEL — 4000 XQ
● NEMA 1 steel enclosure with hinged lockable door
with viewing window.
● Manual Run/Off/Auto control switch.
● Separate Pre-Heat pushbutton.
● Red emergency stop pushbutton.
● Lamp test/reset pushbutton/activates fuel gauge.
● AC instrumentation: 1-voltmeter, 1-ammeter,
1-frequency meter.
● Engine gauges for: Oil pressure, Coolant
Temperature, Battery Volts, Fuel Level.
● Fuel level display with momentary activation.
● Battery Charger, 3 Amp float/equalize, UL listed.
● Hours run meter.
● Voltage adjust potentiometer.
● Speed adjust potentiometer.
● Cycle cranking with 3 adjustable time
crank/rest periods.
● 1 — 7 Position voltmeter phase selector switch.
● 1 — 4 Position ammeter phase selector switch.
● Shutdowns: High Coolant temperature/Low Coolant
level, Low Oil pressure, Overcrank, Overspeed.
● Low Fuel level/Fuel tank leak, Low Battery volts
alarms.
● Printed circuit board control logic.
● Panel Light.
● 2 — Single phase — California style Twistlocks,
50 Amps @ 208 Volt phase to phase, 120 Volt phase
to neutral or 240 Volt phase to phase, 139 Volt phase
to neutral.
● 2 — Single phase — GFCI Duplex receptacles,
20 Amps @ 120 Volts.*
● 2 — Three phase — NEMA locking receptacles,
20 Amps @ 208/120 Volts.*
● 1 — Single phase — NEMA locking inlet receptacle
for 125 Volt, 30 Amp rated auxiliary supply.
● Individual circuit breaker protection for receptacles.
Also act as on/off switches.
● Two wire remote start connection terminals.
DISTRIBUTION PANEL
● NEMA 1 steel enclosure with hinged lockable door.
● 1 — 3 Pole MCCB’s with solid neutral (4 Wire).
UL/CSA listed with shunt trip.
● Integral trip unit for thermal and magnetic overload
protection on MCCB’s.
● Main bus connection studs enclosed with
hinged transparent cover for easy access
and operator safety.
● Common bus connection studs for 480/277 Volt,
208/120 Volt 3 phase and 240/120 Volt Single Phase.
*** Receptacles not for use with low voltage adjusted to 240 Volts.
Weight
Model
Length
in (mm)
Width
in (mm)
Height
in (mm)
With Lube Oil
& Coolant
lbs (kg)
XQ30P4
114.2 (2900)
44.5 (1130)
70.9 (1800)
3727 (1694)
With Fuel,
Lube Oil &
Coolant lbs (kg)
4788 (2176)
RATING DEFINITIONS
Standby — Applicable for supplying continuous electrical
power (at variable load) in the event of a utility power failure.
No overload is permitted on these ratings. The generator on
the generator set is peak prime rated (as defined in ISO8528-3)
at 86°F.
Prime — Applicable for supplying continuous electrical power
(at variable load) in lieu of commercially purchased power.
There is no limitation to the annual hours of operation and
the generator set can supply 10% overload power for 1 hour
in 12 hours.
www.CAT-ElectricPower.com
278-397
© 2005 Caterpillar
All rights reserved.
Printed in U.S.A.
Market: N. America
LEHF4785-01 (02-05)
Materials and specifications are subject to change without notice.
The International System of Units (SI) is used in this publication.