VPS-SP Series
mPS-SP
Series
On-Line Double Conversion UPS
Stand Alone and Parallel
Three-Phase, 6kVA to 250kVA
mPS-SP SERIES
The mPS-SP series is the next generation of the winning model mPS. This unbeatable model has been renewed
with extended software and hardware designs, offering even more features and advantages for YOU!
From pre-sale, commissioning to after sale-service.
The following are the added new features of the mPS-SP:
Universal software enables to configure the UPS on-demand for different types and setups.
Improved on site service procedure - boards can be configured on site inside the UPS
Single design for Stand-alone and Parallel configuration models
Extended range of events on UPS log provides detailed information of UPS anomaly history
Main Features
True Double Conversion on-line topology
On-line batteries. No transfer time to batteries
Precise DC voltage regulation of 1%
Full microprocessor control
Variety of options, configurable from panel
Output isolation transformer
DC Soft-Start
Enlarged charger for longer backup time
Automatic and manual battery tests
Operates with both symmetrical and non-symmetrical
loads, and linear and non-linear loads
Designed for both Wye and Delta load
connections
Various input/output voltages and frequencies
Large LCD display
Logs up to 256 events
RS232 interface with smart software option
Real time clock
Independent output voltage control for any single phase
Charger Voltage regulation according to EURO BATT
requirements
Options
External STSW module connection for
increased reliability
Redundant parallel connection, with
active current sharing
12-pulse rectifier
Input filter for 7%-10% THDI
Isolation transformer for static switch
High input PF 0.95-0.96
Battery charge current limit
SNMP management
WING - wireless management card
Gamatronic Double Conversion, On-Line Batteries UPS System Topology
ST.SW
AC Input
DC Link
Battery
AC Output
Parallel Redundant UPS System
Similar mPS-SP units may be interconnected in
Parallel to create an enhanced security redundant
system, implementing the following features:
Leading/driven logic (without dedicated
master/slave units)
Precision synchronization control circuitry
Active current sharing circuit to distribute the
load equally between the UPS units
Unique diagnostic system employed to detect
and isolate a faulty UPS unit
Digital Phase Locked Loop system (PLL)
Each UPS equipped with its own battery set
Output connected directly in parallel mode
without any external device
A ten-wire signal bus for synchronization and
active current sharing between units
Centralized and Decentralized STSW
configurations are both available (as illustrated
below)
BYPASS
AC INPUT
EXTERNAL
ST.SW
UPS 1
DC
LINK
AC INPUT
BYPASS
BATTERY
OUTPUT
CNTRL
PARALLEL
COMM.
BUS
UPS 2
DC
LINK
AC INPUT
BYPASS
BATTERY
AC
OUTPUT
AC OUTPUT
BUS
OUTPUT
CNTRL
UPS N+1
DC
LINK
AC INPUT
BYPASS
The parallel connection is available for:
BATTERY
OUTPUT
CNTRL
N+1
Centralized Parallel System
mPS-SP 3/3*
mPS-SP 3/1*
* Note: the UPS units should include the
optional output inductor
BYPASS
AC INPUT
UPS 1
ST.SW
DC
LINK
AC INPUT
BATTERY
AC
OUTPUT
BUS
CNTRL
PARALLEL
ST.SW
BUS
UPS 2
ST.SW
AC INPUT
DC
LINK
BATTERY
CNTRL
1+1
Decentralized Parallel System
AC
OUTPUT
PARALLEL
COMM.
BUS
mPS-SP 3/1
Technical Specifications
MODEL
6K
8K
10K
15K
20K
30K
40K
50K
60K
80K
INPUT
Voltage
3 X 380/400/415Vac (208 / 220 optional)
47 53 Hz (57 63 Hz)
Frequency
OUTPUT
Voltage
220/230/240Vac (120 optional), no DC component
Power
6
4.8
(kVA)
(kW)
10
8
8
6.4
15
12
20
16
30
24
50
40
40
32
60
48
80
64
Efficiency AC - AC
90.5
90
@ 100% Load (%)
@ 50% Load (%)
91.5
91
94.5
Efficiency DC-AC @100% Load (%)
92
90.5
92.3
91.8
95
95.5
3336
4004
92.5
92
96
Heat Dissipation (W) @ Full Load
(1W = 3.4 BTU/h)
499
839
672
1114
1486
2086
2782
5189
BATTERY OPERATION
DC Voltage
432Vdc for standard models
According to customer requirements, external batteries
Backup Time
Approx. 6-8 hrs.
Battery Recharge Time
Expected Battery Life
Approx. 4-6 hrs.
5 Years (10-12 years optional)
PHYSICAL
Size (cm)*
Height
Width
Depth
Weight (kg) w/o Batteries
Audible Noise (dB) @ 1.5m
90
51
75
24
80
95
52
95
53
95
40
83.5
115
180
56
60
* Size of cabinet may change according to UPS specification
All specifications given are typical and subject to change without notice
225
62
130
55.5
111
370
400
64
190
70
80
525
mPS-SP 3/3
Technical Specifications
MODEL
INPUT
Voltage
OUTPUT
Voltage
Power (kVA)
(kW)
Efficiency AC-AC @ full load (%)
Efficiency DC-AC @ full load (%)
Dissipation (W) @ Full Load
(1W=3.4BTU/h)
BACKUP OPERATION
Backup Time
DC Voltage
Batteries (12VDC each)
Battery Recharge Time
Expected Battery Life
DIMENSIONS
Height (cm)
Width (cm)
Depth (cm)
Weight (kg) W/O batteries
Audible Noise (dB) @ 1.5m
10K
15K
20K
30K
40K
WIDTH HEIGHT
(cm)
(cm)
64
65
80
85
157
89
157
89
165
125
155
145
80K
100K 125K 160K 200K 250K
10
8
91
93
3 X 380 / 400 / 415Vac (208 / 220 optional), no dc components
20
30
40
50
60
80
100
125
160
16
24
32
40
48
64
80
100
128
91.5
92
92.5
93
93.5
93.5
94
94.5
95
791
1114
15
12
1486
2086
2782
3242
3612
4448
5561
6951
200
160
250
200
95.5
8898 11123 13904
As per customer specifications, external batteries
432VDC for standard models
Sealed Lead-Acid, external
Approx. 6-8 hours
Approx. 4-6 hours
5 years (10-12 years optional)
75
24
80
60
95
40
83.5
190
230
61
DEPTH
(cm)
25
32
45
45
42
45
WEIGHT of
BATTERIES (Kg)
105
240
363
516
800
1100
105
125
260
- Size of cabinet may change according to UPS specification
- All specifications given are typical and subject to change without notice
GAMATRONIC ELECTRONIC INDUSTRIES LTD.
Headquarters and Factory
14 Hartom St. POB 45029, Jerusalem 97774, Israel
Tel: +972-2-5888222 Fax: +972-2-5828875
info@gamatronic.co.il www.gamatronic.com
Tel-Aviv Sales Office
34 Habarzel St. Ramat Hachayal, Tel Aviv, Israel
Tel: +972-3-6499940 Fax: +972-3-6449791
Gamatronic UK Ltd.
15 Chester Road, Colmworth Business Park, Eaton Socon,
Cambridgeshire, PE19 8YT, United Kingdom
Tel: +44 (0)1480 479889/ 472665 Fax: +44(0)1480 407865
info@gamatronic.net
Oct. 2009
60K
3 x 380 / 400/415 / 440Vac (208 / 220 optional)
External Battery Cabinet
TYPE
32x7AH
32X17/20AH
32X24/26AH
32X38/40AH
32X65AH
32X90AH
50K
130
55.5
80
370
62
380
500
190
70
80
590
740
65
1000
190
135
80
1111
67
1300
68
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising