CL100D Series
Uninterruptible Power Supplies
CL100D Series
1 Phase Input / 1 Phase output
CL100D series 6-10 kVA
Online technology , advanced self diagnostics
Power factor corrected input
Output voltage regulation ,low output THD
Fully digital DSP controlled system , PID control
LCD alphanumeric display ,mimic lamps , 5 control buttons
128 Log event records (5000 alarms) with date and time
User selectable easy voltage ,frequency and settings
Cold start from batteries , Rack and tower case options
Battery options for longer battery backup time
Static bypass system , VAT transfer system
Output short circuit protection (isolated from bypass input)
Output overload protection , 150% overload capacity
IPM power module , Output current limit , Operation mode selection (online or offline)
Automatic battery test , Front panel lamp test system
Deep battery discharge protection , Boost charge
Battery capacity and battery remaining time indicator
Maintenance bypass switch , Cabinet inside temperature sensor
REPO input (NO or NC programmable)
RS232 communication interface , management software ,SNMP ,MODBUS
Dry contact outputs (NO or NC programmable) 3 relays standard 2 option
Rack and tower case options
Optional battery temperature compansation
MODEL
Type
CL106D
CL106DR
CL110D
CL110DR
Tower
Rack -5U
Tower
Rack-5U
INPUT
Power factor
Voltage
>0.99 (full load)
220-230 volts AC (+/- 25%) selectable(1phase+neutral)
Input THD
<5% at full load
Input Frequency
50Hz (40-65Hz operation)
RFI Level
EN62040
Indicators
Voltage ,Current ,Frequency
Protection
Input fuse ,input high and line failure alarm
Bypass voltage
220-230 volts AC (+/- 10%) selectable
Bypass frequency
50Hz (Adjustable from +/-1 to 3 Hz)
Manual bypass
Standard
Maintenance bypass
Optional
Split bypass input
Optional
Transfer system
VAT Transfer (voltage adaptive transfer) built in
OUTPUT
Power
6 kVA /4.2 kW
6 kVA /4.2 kW
Power /Crest factor
Voltage
Current(100%load)
19 Amps.
32 Amps.
32 Amps.
50 Hz
Free running:0.01% ,synchron lock adjustable(+/-1 to 3Hz)
Indicators
Voltage , Load , Current , Frequency
Overload protection
Protections
10 kVA /7 kW
220-230 volts AC (+/- 1%) selectable(1phase+neutral)
19 Amps.
Frequency
Frequency tolerant
10 kVA /7 kW
0.7 - 3:1
100%-125% 10 mins,126%-150% 1 min
Voltage low ,high ,short circuit,waveform error,DC leakage
THD
<3% (at 100% Load)
Output connections
Hardwired+2xIEC sockets on the rear side
BATTERY
Type
Battery number
Cabinet
Sealed Lead Acid
20x4.5Ah
20x4.5Ah
20x7Ah
20x7Ah
internal
internal
external
external
Battery test
Available (automatic or manual)
Boost charge
Available adjustable(288V for 20x12V batteries)
Protection
Battery low shutdown ,low warning ,high alarm
Average battery high alarm , fuse protection
Limited (adjustable from 1 to 3 amps.)
Charge current
End of discharge
Adjustable(192V for 20 batteries)Deep discharge protection
Float charge voltage
Adjustable(272V for 20x12V batteries at 25C)
GENERAL
Communication
Options
REPO input , 3 relays and RS232 standard ,SNMP and MODBUS optional
2 relay outputs ,1 automation input,remote panel,RS232 port multiplexer
Front panel
2x16 LCD panel , 3 Leds and 5 buttons
Dimesions
215x595x435
425x595x215
215x595x435
425x595x215
Weight
25kgs/55kgs
25kgs/55kgs
28kgs
28kgs
Acoustik noise
<50dB
Temperature range
Relative humidity
Vantilation
Altitude
0 C - 40 C
<90% (non condensed)
Forced air cooling
2000 m. At nominal power
Protection degree
See communication properties for more information
IP20
CL100D Series Uninteruptible Power Supply
1 phase input / 1 phase output
FRONT PANEL SUMMARY
Human interface
Organization
Log events
Measures menu
functions
Command menu
functions
Options menu
functions
Service menu
functions
Alarms menu
functions
Information menu
2x16 characters 2 lines alphanumeric LCD display
Mimic lamps ,5 buttons ,sound buzzer
2 level menu structure
measures ,command ,options ,service ,alarms ,information,time
adjust , status menu
128 events (includes 5000 alarms) with date and time
Each event contains 40 alarms ,RS232 download available
Output load and current ,output voltage and frequency
bypass voltage , bypass frequency ,input voltage and frequency
input current
battery voltage and charge current ,battery capacity
Battery remaining time
cabinet inside temperature
Sound on/off ,manual bypass
cancel shutdown ,lamp test
Language selection ,operating mode selection
restart on/off option ,remote security on/off option
batt.test on/off ,boost charge on/off
charger with PFC or seperate ,load current limit on/off
VAT on/off option ,adaptor internal/external option ,
Dry contact relays NO/NC selections
Operating hourmeter ,next service remainder indicator
maximum load value ,start battery test ,start boost charge
relay simulation ,fault reset
Log event monitoring
Log event table clear function (password protected)
Bypass Synchron and communication status
output power range ,UPS model
Time menu
Time and date monitoring ,time and date adjustment
Adjust menu
Password protected adjustment and calibration menu
Status menu
Shutdown delay in minutes
restart delay in minutes
Overload timeing if load is bigger than 100%
Fault ,alarm or warning status notification
LCD 1.line
For monitoring parameters ,option selection and for adjustments
LCD 2.line
At the same time 45 alarms can be shown by time sharing
Mimic lamps
Load on bypass ,load on UPS and alarm lamp
Buttons
Up ,down ,left ,right and enter buttons
Power button
Single ,press on / press off (time delayed ,at the end of delay
transfers the load to bypass if depressed power off)
LCD backlight
Available
LCD refresh rate
Every 1 second ,if any button pressed immediately
Buzzer function
Fault buzzer sound continuous
Alarm 1 second beep , 1 second silent
Warning 1 second beep, 3 second silent
CL100D Series Uninteruptible Power Supply
1 phase input / 1 phase output
COMMUNICATION FUNCTIONS
RS232 port
Available
Connector type
DB9 (9 pins)
Isolation
İsolated from UPS PCB boards (1500 volts)
Port type
Interactive read and if allowed write
Adjust UPS from RS232 Available for all parameters (with adjustment software)
Log event download
from RS232
Available (with software)
Time and date
Available (with adjustment software)
adjustment from RS232
Port write security
ON/OFF selectable , if OFF selected port is read only write
impossible
Line failure relay
connection
Available NO/NC selectable
On DB9 connector
Battery Low relay
connection
Available NO/NC selectable
On DB9 connector
Bypass alarm relay
connection
Available NO/NC selectable
Screw terminals and on DB9 connector
REPO input
connection
Available (Remote emergency power off input) NO/NC selectable
Screw terminals
Aux relays
connection
2 programmable relays available as option
Screw terminals
Digital input
connection
Available as option
Screw terminals
Shutdown
From RS232 delayed shutdown and restart can be programmable
Cancel shutdown from RS232 or from front panel
SNMP adaptor
Available as option (internal or external)
MODBUS adaptor
Available as option (external)
Remote monitoring
panel
Available as option
RS232 port multiplexer
Available as option (external)
Management software
TMON SERVER (up to 3 clients free)
10-50-100 clients option
Alarm SMS message
TMON server software supports SMS modem
Alarm e-mail message
TMON server software supports SMTP server connection