CompX refrigerator eLock Instructions
Thank you for purchasing the CompX eLock. The
information contained in these instructions is intended
to serve as a guide so as to allow the eLock to be quickly
and easily put into service.
150 series refrigerator eLock
1
2
3
4
Unit Features:
5
w Each eLock can hold any combination of up to 250
Supervisors and Users
w Choose a model to use existing HID Prox or HID iCLASS
credentials that can be programmed to operate each eLock
w Spring bolt latching mechanism provides automatic relocking
w Door position switch input (requires additional hardware)
w Membrane keypad provides durable performance and easy
cleaning
6
7
8
What’s in the box?
w1 – eLock
w1 – eLock mounting plate
w1 – strike plate
w1 – strike plate cover
w8 – #8 x 3/8” Phillips flat head sheet metal screw (mounting
plate)
w2 – #8 x 1/2” pin-in Torx pan head sheet metal screw (strike
plate)
w2 – #8 x 1/2” pin-in Torx flat head machine screw (strike
plate cover)
w1 – 7” foam tape (strike plate)
w2 – 5” foam tape (mounting plate)
w1 – battery compartment
w1 – warranty card
w1 – serial code sticker set (keep in a secure location)
w1 – in-box instructions
150 Series — CompX refrigerator eLock Instructions
9
eLock controller
1. Low battery
indicator (yellow
LED)
2.Red LED
3.Green LED
4.Alpha-numeric
keypad
5. “ENTER” button
6. “CLEAR” button
7. HID Prox or HID
iCLASS reader
location
(if equipped)
8. USB Port for direct
connection to
LockView software
9. AA Battery pack
– 6 (BATTERIES NOT
INCLUDED)
1
150 Series Refrigerator eLock — Programming
What’s needed?
w 6 – premium brand AA alkaline batteries
wDrill
w #2 philips head bit
w T15 pin-in Torx (6-lobe) bit or driver (secures battery
compartment and strike plate cover screws)
w Rubbing alcohol
wLevel
Care and Cleaning
Note: Green LED on reader will flash upon presenting a valid
Supervisor level credential, versus a solid green LED upon
presenting a User level credential
INITIAL PROGRAMMING OUT OF THE BOX or AFTER A
FACTORY RESET HAS BEEN PERFORMED
(See page 3 for FACTORY RESET instructions)
1. Press and hold “ENTER” until the beeping stops
2. Enter PIN (4 to 14 digits) and press “ENTER” or present card
(if equipped)
The eLock is a battery operated device. Therefore, it should
This PIN / card is now a Supervisor level credential occupying
slot 001
The maximum number of slots per eLock is 250
TO ADD A USER
1. Input a valid Supervisor PIN and press “ENTER” or present
valid Supervisor card
2. Press and hold “ENTER” until beeping stops
3. Input the new User PIN and press “ENTER” or present new
User card
be part of a regular battery maintenance program.
1.
To clean the surface of the eLock controller, apply non-acid
based cleaner to a clean cotton cloth; do not spray cleaner
directly on the controller. Wipe down keypad and housing
taking care around the USB and edges of keypads. Wipe
excess cleaner off of all surfaces.
2.
3.
4.
Setting up the eLock
Install 6 AA alkaline batteries. (not included).
Warning: install the batteries as shown in the battery
compartment. Polarity (+) or (-) must be correct. Replace
batteries as a set. Always use new batteries when replacing
the old set. Do not combine a used battery with a new one.
Only use premium alkaline batteries; do not mix battery
types.
GETTING STARTED
The eLock is shipped with no PIN or if equipped card
credentials.
There are 2 levels of credential: User / Supervisor.
Only a Supervisor credential(s) is allowed to manually
program
2
TO ADD A SUPERVISOR
Input a valid Supervisor PIN and press “ENTER” or present
valid Supervisor card
Press and hold “ENTER” until beeping stops
Press and hold “ENTER” again until beeping stops
Input new Supervisor PIN and press “ENTER” or present NEW
Supervisor card
TO DELETE A USER OR SUPERVISOR
1. Input a valid Supervisor PIN and press “ENTER” or present
valid Supervisor card
2. Press and hold “CLEAR” until beeping stops
3. Input the PIN to be deleted and press “ENTER” or present
existing card to be deleted
TO ADD A USER WITH A SPECIFIC SLOT
ASSIGNMENT
1. Input a valid Supervisor PIN and press “ENTER” or present
valid Supervisor card
2. Press and hold “ENTER” until beeping stops
3. Enter slot number that will be assigned to user and press
(Example: to program slot 18 type 018)
4. Input the new PIN (4 digit min) and press “ENTER” or present
NEW card
150 Series — CompX refrigerator eLock Instructions
150 Series Refrigerator eLock — Programming / Operation
1.
2.
3.
4.
TO DELETE A USER WITH A SPECIFIC SLOT
ASSIGNMENT
Input a valid Supervisor PIN and press “ENTER” or present
valid Supervisor card
Press and hold “CLEAR” until beeping stops
Enter slot number to be cleared and press “ENTER” (example:
to clear slot 6 type 006)
Enter slot number to be cleared again and press “ENTER”
(example: to clear slot 6 type 006)
Methods to begin building
a database of eLocks in
CompX’s LockView Software
OPERATION INSTRUCTIONS
Stand-alone eLocks (Direct USB connection to laptop
computer with LockView is required) There are two methods
that can be used to add eLocks to the LockView software.
Follow the below instructions to open the eLock
KEYPAD: Enter in a valid PIN (4 to 14 digits) and press
“ENTER”.
CARD: If the eLock is also equipped with a card reader (HID
Prox or HID iCLASS), present a valid card.
DUAL CREDENTIAL: If the valid Supervisor/User is a dual
credential (programmable only in LockView) enter the first
credential (PIN or card) and then enter the second credential
(PIN) and press “ENTER”. Note the second credential must
be a 4 to 14 digit PIN.
The latch bolt will extend automatically after the factory
default time or custom programmed time as set in LockView
has expired - press “CLEAR” to extend the bolt immediately.
For complete details on how to build a database of users
and eLocks, see the CompX LockView Software Instruction
Manual.
CompX LockView Software v5 (not included) must be
installed and the eLock must be in SETUP mode before
continuing. See page 3 for Setup Mode Instructions.
Automatic Method
Note: Supervisors and/or Users that already exist in the
eLock will automatically be carried into LockView once the
eLock has been enrolled.
1. With the eLock in SETUP mode, connect the eLock via the
USB cable to the computer on which LockView is installed.
2. Login to LockView.
3. After 30 seconds, the below will appear.
NOTE: After 5 minutes of inactivity, the eLock will exit SETUP
mode.
SETUP MODE: Required to allow the eLock to be added to
LockView software and to perform a FACTORY RESET. Press
and hold “CLEAR” until the audible beeping stops. Enter
the SETUP CODE (Setup Cd) and press “ENTER”. See green
sticker set for setup code.
FACTORY RESET
WARNING: FACTORY RESET will delete all previously
programmed credentials
With the eLock in SETUP MODE, while pressing and holding
“CLEAR”, press and continue to hold “8” and then press “6”.
The eLock will make a short series of audible major tones and
the green LED will blink continuously. Programming can begin
again as if the eLock was “OUT OF THE BOX” (see page 2).
4.Click Yes.
5. The below will appear. Type in the name of the lock.
6.Click Save when done.
7. Go to Lock Editor tab in Lock/User Editor.
150 Series — CompX refrigerator eLock Instructions
3
150 Series Refrigerator eLock — Programming / Operation continued
8. Left click to highlight the name of the lock and then click Edit
Lock.
1. Login to LockView.
9. Verify and/or adjust all other lock parameters. (See LockView
Instruction Manual for complete details.)
3. Enter the required information: Lock Name; Lock Serial
Number and Setup Code (supplied on green sticker set as
Setup Cd).
10.Click OK when done.
Manual Method
Note: Any existing Supervisor and /or User credentials that
have already been manually programmed in the eLock will be
removed. If it is desired to keep existing credentials, choose
the Automatic Method to enroll the eLock.
2. Go to Lock/User Editor; Lock Editor tab and click Add Lock.
4. Verify and/or adjust all other lock parameters and click OK.
(See LockView Instruction Manual for complete details on
these options)
5. After 30 seconds, the lock will be updated in LockView. Click
Refresh to prompt the update.
150 Series — Installing the vertical mount refrigerator kit
Step
1:
• VERIFY ELOCK OPERATION BEFORE BEGINNING INSTALLATION •
Install the strike
Note: The end of the metal
strike needs to curve up.
There are two main parts of this installation: installing the strike and installing
the eLock assembly. The strike and the eLock assembly can be mounted either
with foam tape or by drilling holes and using screws. It is important to note that
mounting the strike and the eLock assembly are independent of each other. One
can be foam tape mounted, and one can be drill mounted if desired. The two do
not need to be mounted using the same method.
Option A
Mount the strike
at least 4" from
NON-HINGED EDGE
of the refrigerator.
Option B
Foam Tape Installation: Option A
Please note that if foam tape installation
of the strike is used, the strike will not
be adjustable once it's put in place.
a.Clean the top refrigerator as well as the
strike with rubbing alcohol. Wait for the
alcohol to dry.
b.With a pencil, mark refrigerator 6-7/8"
from the front of the door and at least 4"
from the non-hinged edge.
4
Measure from this line to the front of the
cabinet (dim. “A”); cut a piece of tape
this length.
c.Remove tape backer and affix to end
of strike. The upward curve should be
on top. Apply tape to the opposite side.
Remove backer. Line up strike with line on
refrigerator; apply pressure to seal it on.
Drilling Installation: Option B
a.Before drilling, verify that there are no
refrigerant lines inside the top of the
refrigerator.
b.Drill a 9/64” hole, 5-7/8” from the
edge of the front of the refrigerator and
at least 4” from the non-hinged edge of
the refrigerator.
150 Series — CompX refrigerator eLock Instructions
150 Series — Installing the vertical mount refrigerator kit continued
Step
2:
Secure the strike and attach the strike cover (if strike was mounted using foam tape, ONLY do b.)
a.Screw one tamper resistant sheet metal
screw into the center of the strike's slotted
area. Note: The end of the metal strike
needs to curve up.
b.Place the plastic strike cover over the
metal strike. If strike was mounted using
foam tape, please proceed to Step 3.
c. Attach with one tamper resistant machine
screw.
Step
3:
Mount the main CompX eLock® body to the refrigerator door
The CompX eLock can be mounted to the front of the refrigerator by
using the provided foam tape or by drilling holes and using screws
(provided).
Foam Tape Installation
Please note that if foam tape installation is used, the eLock will
not be adjustable once it is put in place.
a. Clean the front of the refrigerator with rubbing alcohol. Wait for
the alcohol to dry.
b. Click the eLock onto strike plate, ensuring proper latch bolt
engagement and mark the eLock location on the refrigerator
door with a pencil.
c. Remove one side of the protective liner from the
double-sided tape and install on the CompX
refrigerator eLock mounting plate.
d. Attach the mounting plate to the back of the
eLock.
e. Remove remaining protective liner from doublesided tape.
f. Carefully press eLock onto the refrigerator door in the location as
previously marked.
g. Verify proper operation and alignment.
h. Firmly press eLock onto fridge. Note: Temporary support of
the eLock may be required to allow adequate adhesion time
of the foam tape.
150 Series — CompX refrigerator eLock Instructions
Drilling Installation
a. Cut a 3” piece of doublesided foam tape and attach
it to the mounting plate
to serve as an location
alignment holder.
b. Attach the mounting plate to
the back of the eLock.
c. Click the eLock onto strike
plate, ensuring proper latch
bolt engagement. Press
eLock onto the refrigerator
door.
d. Remove eLock from mounting plate by
pressing down on the mounting plate release
tab.
e. Drill eight 9/64” holes through the mounting
plate holes into the refrigerator door. Secure
with mounting plate screws.
f. Attach eLock to mounting plate.
g. Verify proper operation and alignment.
Note: If foam tape was used to mount the strike, the eLock
refrigerator kit installation is COMPLETE.
5
150 Series — Installing the vertical mount refrigerator kit continued
Step
4:
Finish installation of the strike (ONLY
if drilled installation of strike was used)
a. Remove the plastic cover from the strike plate. Drill 9/64"
hole in second opening of strike.
b. If adjustment of strike is needed, loosen the first strike
screw and adjust the strike. Tighten the screw.
c. Drill hole for second screw and install second screw.
d.Attach the plastic strike cover with two tamper resistant
machine screws.
150 Series — Installing the horizontal mount refrigerator kit
Step
1:
• VERIFY ELOCK OPERATION BEFORE BEGINNING INSTALLATION •
Install the strike
Note: The end of the metal
strike needs to curve out.
There are two main parts of this installation: installing the strike and installing the
eLock assembly. The strike and the eLock assembly can be mounted either with foam
tape or by drilling holes and using screws. It is important to note that mounting the
strike and the eLock assembly are independent of each other. One can be foam
tape mounted, and one can be drill mounted if desired. The two do not need to be
mounted using the same method.
Option A
FoamTape Installation:OptionA
Please note that if foam tape installation
of the strike is used, the strike will not be
adjustable once it's put in place.
a.Clean the side of the refrigerator as well
as the strike with rubbing alcohol. Wait
for the alcohol to dry.
b.Along the non-hinged side of the
refrigerator, make a mark 6-7/8” from
6
Mount the
strike at least
4" from the
top of the
NON-HINGED
EDGE of the
refrigerator.
Option B
the front edge of door and a minimum of
4” from the top. Measure from this line to
the front of the cabinet (dim. “A”); cut a
piece of tape this length.
c.Remove tape backer and apply tape.
Line up end of strike with the 6-7/8”
mark on side of refrigerator. Ensure strike
is level, and apply using firm pressure.
Install plastic strike cover on metal strike.
Proceed to step 3.
Drilling Installation: Option B
a.Before drilling, verify that there are no
refrigerant lines inside the side of the
refrigerator.
b.Drill a 9/64” hole, 5-7/8” back from
the edge of the front of the refrigerator
door and at least 4” from the top of the
non-hinged edge of the refrigerator.
150 Series — CompX refrigerator eLock Instructions
150 Series — Installing the horizontal mount refrigerator kit
Step
2:
Secure the strike and attach the strike cover
a.Screw one tamper resistant sheet metal
screw into the center of the strike's slotted
area. Note: The end of the metal strike
needs to curve out.
b.Place the plastic strike cover over the
metal strike.
c. Attach with one tamper resistant machine
screw.
Step
3:
Mount the CompX eLock® housing to the refrigerator door
The CompX eLock can be mounted to the front of the refrigerator by
using the provided foam tape or by drilling holes and using screws
(provided).
Foam Tape Installation
Please note that if foam tape installation is used, the eLock will
not be adjustable once it is put in place.
a. Clean the front of the refrigerator with rubbing alcohol. Wait for the
alcohol to dry.
b. Click the eLock onto strike plate, ensuring proper latch bolt
engagement and mark the eLock location on the refrigerator door
with a pencil.
c. Remove one side of the protective liner from
the double-sided tape and install on the
CompX refrigerator eLock mounting plate.
d. Attach the mounting plate to the back of the
eLock.
e. Remove remaining protective liner from
double-sided tape.
f. Carefully press eLock onto the refrigerator door in the location as
previously marked.
g. Verify proper operation and alignment.
h. Firmly press eLock onto fridge. Note: Temporary support of the
eLock may be required to allow adequate adhesion time of the
foam tape.
150 Series — CompX refrigerator eLock Instructions
Drilling Installation
a. Cut a 3” piece of double-sided foam tape and attach it to the
mounting plate to serve as an location alignment holder.
b. Attach the mounting plate
to the back of the eLock.
c. Click the eLock onto strike
plate, ensuring proper
latch bolt engagement.
Press eLock onto the
refrigerator door.
d.Remove eLock from
mounting
plate
by
pressing down on the
mounting plate release
tab.
e. Drill eight 9/64” holes through the mounting
plate holes into the refrigerator door. Secure
with mounting plate screws.
f. Attach eLock to mounting plate.
g. Verify proper operation and alignment.
Note: If foam tape was used to mount the
strike, the eLock refrigerator kit installation
is COMPLETE.
7
150 Series — Installing the horizontal mount refrigerator kit continued
Step
4:
Finish installation of the strike (ONLY
if drilled installation of strike was used)
a. Remove the plastic cover from the strike plate. Drill 9/64”
hole in second opening of strike.
b. If adjustment of strike is needed, loosen up the first strike
screw and adjust the strike. Tighten up the screw.
c. Drill hole for second screw and install.
d.Reattach the plastic strike cover and secure with two
tamper resistant machine screws.
150 Series Refrigerator eLock — Accessories
HID Prox User,
Supervisor Card
®
LockView
Software Kit
®
(1 LockView® travel drive, 1 USB cable)
Part Number:
EL-2004-PC (no logo)
EL-ICLASS-C
(HID iCLASS user, supervisor card)
LOCKVIEW-5PRO
Bit
(T-15 pin-in-head Torx 6-lobe)
HID Prox Tag
®
Part Number:
Part Number:
EL-BIT-15
EL-2004-PT
EL-ICLASS-T
Note: product images are not to scale.
HID is a trademark of HID Corporation.
Part Number:
Screwdriver
(T-15 pin-in-head Torx 6-lobe)
(HID iCLASS tag)
Part Number:
EL-DRV-15
LockView® software
q Add, edit, view and delete users / supervisors
and their credentials
q Add, edit and delete CompX eLocks®
q Assign access rights between users / supervisors
and CompX eLocks® in the database
q Download, view, save, print, archive and delete
audit trails
q Dual credential access available
q Set real time clock
q Time based access restrictions
q Create user groups
qWindowsTM based
LockView is a Registered
Trademark of CompX
International. Windows is a
trademark of the Microsoft
Corporation. Specifications
may vary based on user
application.
Part #: 334008-0000-00
Copyright 2017 © CompX Security Products / 847.752.2500 / compx.com / 715 Center St., Grayslake, IL 60030
Any companies and/or products referred to herein are marks or registered trademarks of their respective companies, owners and/or mark holders.
8
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising