Special Arming Modes
Special Arming Modes
A P P L I C A T I O N
N O T E
Doc. - Ref. 240-X
Version : March 2014
www.videofied.com
Special Arming Modes
A P P L I C A T I O N
N O T E
Special Arming modes is a partial arming function available for all Videofied® alarm panels.
Special arming allows to arm only a fraction of the installation, for example to arm only a garden or a garage when the user is in
another part of the installation.
Access to Special Arming menu
Lvl. 4
CONFIGURATION
OK or YES
SPECIAL
ARMING MODES
Alarm Full Arm, SP1 and SP2 Menu
ALARM
SP1
Area : 1234
Define the arming of each area in this specific mode. Each state is
described in page 3.
On Alarm :
AREA : 12 3 4
STATE: AAAA
ON ALARM :
SIREN
SILENT ARMING
Disabled / Enabled
PROFILE NAME :
SP1
This parameter sets how the panel responds to an intrusion for each arming
mode :
Siren
Immediate triggering of all sirens
Delay Beeps
Entry/Exit delay beeps, then triggering of all sirens
Silent
No Sirens, No Beeps
Without Siren
Beeps on the keypad only
Silent Arming :
Unavailable in Full Arm
Enable this parameter to disable exit delay beeps for this special
arming mode.
Profile name :
Name for the special arming mode, this name will be displayed during
the arming.
Examples : Night, Holidays, etc...
www.videofied.com
2
Special Arming Modes
A P P L I C A T I O N
N O T E
Arming States
For each arming mode you can define how each on of the 4 areas
is armed.
AREA : 12 3 4
STATE: AAAA
By pressing on the digit associated with the area, the system
changes the arming state of the chosen area.
House
A
Default parameter. In this arming state, every detector in the area will
be armed regardless of their “DEVICE TYPE” parameter.
Armed
Garden
House
D
In this arming state, every detector in the area will be disarmed
regardless of their “DEVICE TYPE” parameter.
Disarmed
Garden
House
P
In this arming state, all detection devices set as perimetral or
perimetral+ext in their “DEVICE TYPE” parameter will be armed.
Perimetric
Garden
House
E
In this arming state, all detection devices set as external or
perimetral+ext in their “DEVICE TYPE” parameter will be armed.
External
Garden
Most of the time, A and D arming states will be enough to set up the system.
We recommend only using those (see special arming exemple on page 4).
When you register a door contact in the system, the keypad displays “IS
THIS A PERIMETER DEVICE?”. Press OK or YES
www.videofied.com
3
Special Arming Modes
A P P L I C A T I O N
N O T E
Special Arming example
On this installation, the user
wants to protect the outside
of the house with a “Night”
Special Arming.
Area 2
The inside of the house must be
disarmed whereas the outside
must be armed.
Assign all external detectors
to the same area (Area 1 here to
make use of the automatic entry
delay).
Area 4
Area 3
The other detectors may
be assigned to other areas
indifferently.
Area 1
ALARM
NIGHT
ZONE : 1 2 3 4
STATE : ADDD
This mode has been named NIGHT to be identified by the user while it is
arming.
When this mode is armed, only external detectors will be armed and will
trigger an alarm in case of intrusion.
www.videofied.com
4
Special Arming Modes
A P P L I C A T I O N
N O T E
Define Device type
Lvl. 4
CONFIGURATION
If you use P and E arming state, you will need to change the detectors
“DEVICE TYPE”.
Once in the device list, select the device to configure then go to the
following menu :
AREAS AND DEVICES
DEVICE TYPE :
NONE
Here are the option you can choose as “DEVICE TYPE” :
DEVICES
•
•
•
•
•
DEVICE
CONFIGURATION
None : only armed in areas set as A.
Perimetral : only armed in areas set as A and P.
External : only armed in areas set as A and E.
Perimetral + External : only armed in areas set as A,P and E.
24h : always armed
OK or YES
Special mode arming
Full arm :
Arming of all areas and all devices. Use a badge
or a user code and press
keypad or OK /
/
on the panel
on the XMA/XMB keypad.
SP1 :
Partial Arming (1) is enabled by entering the user
code and pressing
on the panel keypad,
on the XMA/XMB keypad or
on the remote
keyfob RC.
RC Keyfob
SP2 :
Partial Arming (2) is unavailable on the XL panel
keypad. It is enabled by pressing the
XMA/XMB keypad or
XMA/XMB
key on a
on the remote keyfob RC.
XL Panel
EMEA SALES
North American Headquarters
23, avenue du Général Leclerc
92340 BOURG-LA-REINE
FRANCE
E-Mail : emeasales@rsivideotech.com
1375 Willow Lake Blvd, Suite 103
Vadnais Heights, MN 55110
USA
E-Mail : usasales@rsivideotech.com
www.videofied.com
Full Arm
SP1
SP2
5
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF