A digital indicator that controls measurement by amplifying and

A digital indicator that controls measurement by amplifying and
Specifications
Model
Sensor applied voltage
DC10V/5V/2.5V Output current: within 120mA 4-wire system Applied voltage digital adjustment
Sensor input range
-3.0 ~ + 3.0 mV/V
Equivalent input
calibration range
0.5 ~ 3.0 mV/V
Accuracy
Non-linearity: within 0.02%FS ±1 digit (during 3.0 mV/V input); Zero drift: within 0.5μV/℃ RTI; Gain drift: 0.01%/℃)
A/D converter
Speed: 2000 times/second 16 bit (binary)
Analog filter
10/30/100/300 Hz digital adjustment
Analog monitor output
Analog voltage proportional to sensor input Output level: App. 2V per 1mV/V input
Analog output
D/A converter (Option) Voltage: 0 ~ 10V; Current: 4 ~ 20mA
Display
STN color LCD (320x240 dot) Indicator value: ±99999
Weight: kg, Mg, g, mg, μg, t, lb; Force: N, kN, MN, mN, μN, Nm, kNm, MNm,
mNm, μNm; Pressure: Pa, kPa, MPa, GPa, hPa, mPa, μPa, bar, mbar, μbar,
mmHg, N/m2; Density: kg/m3, g/cm3, t/m3, g/ml, g/l, kg/m, mg/m; Momentum:
kgm/s, kgm2/s, kgm2; Viscosity: PaS, mPaS; Length: km, m, cm, mm; Speed: m/s,
km/h, m/s2, rpm; Flow rate: kg/h, kg/min, kg/s, t/h, t/s, t/min, m3/h, m3/min, m3/s,
l/h, l/min, l/S
Weight: kg, g, t; Force: N, kN;
Pressure: N/m2, Pa, kPa, MPa, bar
* "No-unit" setting is also feasible
Display unit
Tracking
Sample
Peak
Bottom
P-P
Mean
Max Peak Value
Min Peak Value
Point of inflection
Wave profile holding
External output signal
Control input signal
Interface
(Only one of these
options can be loaded in)
Range setting
・ All range
・ External specified range
・ Timer specified range
・ Trigger timer specified range
Upper/lower limit comparison open collector output (HH, HI/OK/LO/LL); Holding end output (H/E); Serial data output (SI/F); asynchoronous 600bps
Graphic START/STOP input; multi-holding (comparison, holding) setting
values selective input; Holding control input; Digital zero-input
Graphic START/STOP input; multi-holding (comparison, graph, holding) setting
values selective input; Holding control input; Digital zero-input; Calibration value
selective input
SI/F interface; RS-232C communication interface (Option); RS-485 interface
(Option); DeviceNet interface (Option); CC-Link interface (Option); BCD
parallel data output (Option); D/A converter (Option)
SI/F interface; RS-232C communication interface; RS-485 interface (Option);
DeviceNet interface (Option); CC-Link interface (Option); BCD parallel data
output (Option); D/A converter (Option)
Supply voltage
AC100~240V ( ±10%) 50/60 Hz; DC12~24V( ±15%) (Specify for DC during ordering)
Power consumption
AC Spec: max 12W; DC Spec: max 20W
Application requirements
AC Spec: max 15W; DC Spec: max 20W
Temperature: -10 ~ +40℃; Humidity: 80% RH or lower (no condensation)
100 (W) x 96 (H) x 138 (D) mm(not including protruding parts)
Panel cut dimension 92 x 92 (+1-0)mm
External dimension
CE marking certification
EMC Directive EN61326-1 (Class A) Safety Standard EN61010-1
External Dimension
100
91
96
Unit:mm
18
120
143
91
Panel cut dimension
91
92 +1
92 +1
- x
0
-0
100
18
120
135
91
Please note that specifications or designs shown in this catalog may vary due to our continuous product improvement activities.
International Sales Department
Nittetsu Kobiki Bldg 7-16-3 Ginza,
Chuo-ku, Tokyo 104-0061
Tel: +0081-3-5148-3867
Fax: +0081-3-5148-3001
Headquarter:
Technical Center:
Nagoya Sales Office:
Osaka Sales Office:
Hiroshima Sales Office:
Fukuoka Sales Office:
Nittetsu Kobiki Bldg 7-16-3 Ginza, Chuo-ku, Tokyo 104-0061
1-3 Sengendainishi, Koshigaya, Saitama 343-0041
Meihoku Kurokawa Bldg 5-5-3 Shimizu, Kita-ku, Nagoya 462-0844
Sumitomo Seimei Shin Osaka Kita Bldg 4-1-14 Miyahara, Yodogawa-ku, Osaka 532-0003
Funairi Reiku Bldg 9-20 Funairihonmachi, Hiroshima 730-0843
Ota Bldg 1-16 Tsunaba-cho, Hakata-ku, Fukuoka 812-0024
Rev.1.03 2005 JUN.
A digital indicator that controls measurement by
amplifying and performing high-speed digital
processing of subtle signals received from strain
gauge sensor that measures pressure, load or
torque. With the utilization of liquid crystal touch
panel display, visibility and operability of wave
profile display and others are greatly improved.
Through its ample 20-types wave profile
holding function, it is the best digital
indicator for graders and testers
used in results judgment of
assembling work and auto
machining.
Holding Functions
Provides assured support for force control and
assists quality control through its 2000
times/second high-speed processing and powerful
20-types wave profiles holding function.
Sample holding
Holds arbitrary point as of when the holding signal is received.
Timer specified range holding (Peak, bottom, P-P, mean)
A method that shifts the holding within the set timer (hold time) for
detect range upon activation of trigger.
(Example) Peak holding
Sensor input value
Sensor input value
Indicator value
Indicator value
Holding range
Detection range
Liquid Crystal Touch Panel
Display in Pursuit of
Visibility and Operability
Liquid crystal touch panel display that
had attained visibility and operability of
indicator display and wave profile display.
As a Super Signal
Conditioner
May also be used as a super signal
conditioner that outputs scaled analog
signal after digitalizing, filtering and
arithmetic processing of signals received
from sensor via its 2000 times/second
high-response D/A converter.
Wave Profile Display
Function
Wave profile display function that displays
real time input signal to wave profile
display and marks the holding points.
2000 times/second Highspeed Processing
High speed digital circuit and proprietary
programming technology that is able to
perform high-speed processing at 0.5ms
(2000 times/second) from the sensor
signal input moment until the control
signal output.
A Combination of 20-types
Holding Function
Various Interfaces (Option)
for Direct PLC Connection
Sample holding*, peak holding, bottom
holding, P-P (Peak to Peak), holding,
mean holding, external specified range
holding, (peak, bottom, P-P, mean),
timer specified range holding (peak,
bottom, P-P, mean), tr igger timer
specified range holding (Peak, bottom,
P-P, mean), minimum value holding,
maximum value holding and point of
inflection holding* that can quickly detect
required points for analog wave profile.
*with Pre-trigger function
RS-232 Interface
(Standard accessory in F371)
RS-485 Interface
DeviceNet Interface
CC-Link Interface
BCD Parallel Data Output
D/A Converter
Multi-holding Function
Multi-holding function that records up to
16-types holdings and comparison
settings and that is able to perform wave
profile control and changeover at any
time to any type through its external
pulsing signal. Only F371 can records
graphic settings.
Alarm Mode
Able to monitor at real time if the
indicated value during the holding is
abnormal or otherwise.
Additional Helpful
Functions for F371
Analog Monitor Output
Proportional voltage output
accordance to input signal.
Output level for every 1 mV/V output
is app. 2V. With this, regardless to
the non-use of holding function, input
wave profile can be record by the
recorder.
Multi-Calibration Function
Multi-calibration that can record up
to 4-types of calibration values and
able to changeover at any time to
any type through its external pulsing
signal.
Holding range
Peak holding at all ranges
Holds maximum (peak value) at plus direction.
Sensor input value
Holding
time
Indicator value
Trigger timer specified range holding (Peak, bottom, P-P, mean)
A method that shifts the holding within the set timer (hold time) for
detect range when the indicator value exceeds the auto-start level.
(Example) Peak holding
Detection/holding range
Detection/holding range
Sensor input value
Indicator value
Bottom holding at all ranges
Holds maximum (bottom value) at minus direction.
Sensor input value
Auto start level
Indicator value
Detection range
Holding
time
Detection/holding range
Minimum peak value holding
Detects minimum and holds it when the indicator value exceeds
the auto-start level.
Detection/holding range
Sensor input value
P-P (Peak to Peak) holding at all ranges
Indicator value
Holds maximum difference between peak and bottom values.
Indicator value
Sensor input value
Auto start level
Detection range
Indicator value=0
Holding range
Reference line
Detection/holding range
Maximum peak value holding
Detects maximum peak value and holds it when the indicator value
exceeds the auto-start level.
Mean holding at all ranges
Sensor input value
Calculate and update mean and holds it.
Sensor input value
Indicator value
Indicator value
Auto start level
Graphic Screen
Detection range
Displays holding value at the top side and
marks the holding point with red dot.
Holding range
Detection/holding range
Function Setting Screen
Comparison Display Screen
Weight display color changes according to
the comparison results.
OK: Green HI/LO: Yellow HH/LL: Red
Point of inflection holding
External specified range holding (Peak, bottom, P-P, mean)
Calculate and update mean and holds it.
Detects point of inflection and holds it when the indicator value
exceeds the auto-start level.
(Example) Peak holding
Sensor input value
Sensor input value
Indicator value
Indicator value
Auto start level
Detection range
Detection range
Comparison Setting Screen
Holding range
Holding range