GB • CCTV Tester 430 586
LE04240AA
GB
• CCTV Tester
430 586
Indice
1. Introduction
3
1.1
1.2
1.3
1.4
1.5
3
4
5
6
7
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3. Specifiations
Features
Packaging
Front Panel
Side View
Installing the battery
2. Operation
8
Power on
Menu & functions
PTZ controller
Video setting
Colorbar generator
Cable tester
Data monitor
Device setting
Address search
8
8
10
12
13
13
14
14
15
16
GB
Safety instructions
This product should be installed in line with installation rules, preferably by a qualified electrician. Incorrect installation and use can lead to risk of electric shock or fire.
Before carrying out the installation, read the instructions and take account of the product’s specific mounting location.
Do not open up, dismantle, alter or modify the device except where specifically required to do so by the instructions.
All Bticino products must be opened and repaired exclusively by personnel trained and approved by Bticino.
Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement and guarantees.
Use only Bticino brand accessories.
2
1. Introduction
The CCTV tester is developed for the On-Site installation and maintenance of video monitoring system.
It can be used for displaying video, controlling PTZ, generating images, capturing data of RS485 and testing LAN
cable etc.
1.1 Features
•
2.8”TFT-LCD , 960 (H) × 240 (V) resolution.
•
PTZ control: Pan/tilts the P/T unit zooms in/out the lens, adjusts the focus and aperture; sets and calls the
preset position.
•
Video displaying: automatically adapts and displays the video format of NTSC/PAL.
LCD Brightness/Contrast/Color Saturation are adjustable.
•
Video Level testing: video signals measured in IRE or mV.
•
Video Generating: the tester PAL/NTSC generates colorbar video pattern.
•
Data analyse: captures and analyzes RS485 controlling data.
•
Cable testing: tests LAN cable measures the connecting status.
•
Multi-interface and Multi-baudrate: supports RS232 and RS485 baud rate ranging from 150, 600 to
19200bps.
•
Multi-protocol: supports more than twenty PTZ protocols. For example, PELCO-P, PELCO-D, SAMSUNG etc.
•
PTZ address scanning: searches up the ID of PTZ camera.
•
Lithium Ion Polymer Battery (3.7V DC2000mAh).
It can last 11 hours for normal use after charging for 4 hours.
3
1.2 Packaging
Item description
Item picture
Qty
CCTV tester
1
LAN Cable Tester
1
Lithium Ion Polymer Battery
1
Power supply (5V 2A)
BNC Cable
Safety cord
RS485 data cable
1
1
1
1
RS232 cable
1
User manual
1
4
1.3 Front Panel
1
The power indicator: it lights green while the tester is powered on.
2
The data-reception indicator: it lights red while the data is being received.
3
The data-transmission indicator: it lights red while the data is being transmitted.
4
The charge indicator: it lights red while the battery is being charged.
As the charging is complete, the indicator turns off automatically.
5
The display Icon of battery electricity: it displays the electric quantity.
6
Main-menu: it shows main functions of CCTV tester.
7
8
9
Sub-menu: shows and sets the values of functions.
Long-pressing it more than 2 seconds to turn on/off the tester; short-pressing to turn on/off the
PTZ controller menu displaying.
Menu key: it pops up the main-menu; constant-press it or press the
functions.
or
key can shift between
A
Setup key: press it or press left or right key to enter sub-menu to set the parameters of functions.
B
Upward: Select the item which will be set or add the value of the parameter. Tilt the PTZ upward.
5 C
Leftward: Enter the sub-menu or select the parameter whose value will be changed.
Reduce the value of the parameter. Pan the PTZ left.
D
Rightward: Enter the sub-menu or select the parameter whose value will be changed.
Add the value of the parameter. Pan the PTZ right.
E
Downward: Select the item which will be set or reduce the value of the parameter.
Tilt the PTZ downward.
F
Confirm/Open: Confirm the setting of parameters; open the iris.
G
Return/Close: Return or cancel while setting parameters of the menu; close the iris.
H
Near focus: Focus the image nearby.
I
Far focus: Focus the image faraway.
J
TELE: zoom in the image.
K
WIDE: zoom out the image.
1.4 Side view
INPUT
Left side
Right side
M
Reset the default settings of parameters.
N
External power supply (DC, 5V): It is highly recommended to use the equipped power adapter.
O
UTP cable port: please use together with UTP LAN cable tester.
P
RS232 interface: RS232 communication for the PTZ.
Q
Video input (BNC input interface): Inputs the video.
R
Video output (BNC output interface): Outputs the video.
S
RS485/422 Interface: RS485/RS422 communication for the PTZ.
T
Hole for the safety cord.
6
1.5 Installing the battery
The tester has built-in lithium ion polymer rechargeable battery.
The battery cable inside battery cabin should be disconnected for safety during transportation!
Prior to the use of the instrument, the battery cables inside the battery cabin should be well connected
and the color of cables should be at the same side.
for •
•
key At the first time of use, the batteries should be completely exhausted and then recharged
4 or 5 hours.
Usually it need not to disconnect the cable at the normal use, pressing
continuously can power on or off the tester.
The Charge Indicator
lights red when charging the battery, the charge indicator turns
off automatically when the charging is completed.
Notice: When the Charge Indicator
turns off, the battery is approximately 90% charged. The charging time can be extended for about 1 hour and the charging time within 8 hours
will not damage the battery.
The tester can work as usual while it is being charged, however. But the charging time will be extended.
ress the RESET key at the right of the instrument to restore the default settings when the instrument P
works abnormally.
Unlock the battery cover by pushing horizontally as the direction illustrated
Warning: Connect the terminal of the battery with the direction illustrated.
Please take care of the polarity of terminal.
(The wires of the same color should be both at the one side)
Lock the batteries by pressing as the direction illustrated
7
2. Operation
2.1 Power on
Continuously press
(at least 2 seconds) to power on/off the CCTV tester. When the CCTV tester is powered
on, press MODE key the main-menu will pop up.
2.2 Menu & functions
Press MODE key continuously or press the
or
key to select the function (PTZ controller, Video settings,
Colorbar generator, Cable tester, Data monitor, Device setting) and enter corresponding function setting sub-menu.
Press SET key to set the parameters in function sub-menu.
Note: When the CCTV tester is powered on, it will return to the function which is being operated before it is turned
off.
1. PTZ controller
Display the input video images. Pan/tilt the P/T unit and
zoom in/out the image. Setup the controlling parameters
like protocol, communication port, baud rate, PTZ ID,
pan/tilt speed; set and call preset position.
8
2. Video setting
Adjust the LCD brightness, Contrast, Color saturation.
Video Format displaying and Video level testing.
3. Colorbar generator
Output or receive seven different forms of video color
bar to tester monitor, cable or other equipment.
4. Cable tester
Test LAN cable or telephone cable.
The connecting condition and the sequence of wires
will be displayed, as well as the serial number of the
cable tester kit.
5. Data Monitor
Captures the protocol from the controlling system
and display command data. It is helpful to debug and
maintain RS485 communication.
6. Device setting
Set the parameters of the CCTV tester.
(Auto poweroff/Keypad tone/Language/Brightness)
Adress search off :
9
2.3 PTZ Controller
Display the input video images. Pan/tilt the P/T unit and zoom in/out the image.
Setup the controlling parameters like protocol, communication port, baud rate, PTZ ID, pan/tilt speed; set and call
preset position.
The following connections should be confirmed before use
a. The Video In interface of the CCTV tester and the output interface of camera
b. Data A+ of the CCTV tester and A+ of the PTZ camera or controlling device, data B- of the instrument
and B- of the PTZ camera or controlling device
Note: Don’t connect communications interface with a circuit voltage higher than 6V.
DATA A+
DATA BVIDEO IN
VIDEO OUT
VIDEO
RS485
D-/B D+/A
IN
OUT
a- Press SET key to enter the sub-menu of PTZ controller.
b-Press the
or
key to select the parameter
which we want to change the value.
c- Press ENTER key to save the change or press
RETURN key to give up the change.
d- Press SET key to exit the sub-menu.
e- Press POWER key to full-screen the image.
10
Protocol:
Select the protocol according to the protocol of the PTZ camera. Up to 30 popular protocols are
available, like Pelco P, Pelco D, Samsung, Yaan, LiLin, CSR600 etc.
Port:
Select the communication port for the PTZ camera controlling (RS232/422/485).
Baud:
Select the baudrate according to baudrate of the PTZ camera. (150, 300, … , 19200bps).
Address:
Set the ID according the ID of PTZ camera (0~16384).
Pan
Speed:
Set the pan speed of PTZ camera (0~63).
TiltSpeed:
Set the tilt speed of PTZ camera (0~63).
Set PS:
Setup preset position (0~255).
a.P/T/Z the camera to desired position.
b. Press SET key to enter PTZ controller submenu.
c. Move the yellow cursor to “Set PS” and then press
position number.
or
key to select the preset d.Press ENTER key to complete preset position setting or preset RETURN key to give up preset
position setting.
Tips: Press
or
key to accelerate the value changing.
Go PS:
- Call the preset position. (0~255). The PTZ camera will go to the desired preset position.
a.Move the yellow cursor to “Go PS” and then press
number.
or
key to select the preset position
b. Press ENTER key to complete preset position calling or preset RETURN key to give up preset
position calling.
Tips: Press
key to accelerate the value changing.
- OSD Menu (391 715/16/17, 391 695/96)
The way of calling the OSD menu and preset of the PTZ camera may vary with control systems
from different manufacturers. Please read the operation manual of control system manufacturer
for details. The way of calling OSD provided for reference is calling preset-95 (Protocol Pelco-D).
or
a.Move the yellow cursor to “PTZ controller” to enter PTZ controller mode.
b.Press SET key to enter PTZ controller sub-menu. Press
to “Go PS”.
or
key to move the yellow cursor
c.Press
or
key to select the preset number 95, and then press ENTER key to call OSD
menu of the PTZ controller.
Go PS
095
OSD menu of dome
Call the preset
point:95
+
11
OSD Menu of Dome (For reference only)
2.4 Video setting
User can customize the brightness, contrast and saturation of the LCD according to the using environment, the
CCTV tester auto display the format (PAL/NTSC) of video input, and analysis the input video signal level.
a.Press the
or
key to select the parameter which
we want to change the value.
b. Press the
or
key to change the value.
Press ENTER key to save the change or press RETUR
key to give up the change.
c. T
he Video Format and Video Level will be displayed in the
lower portion of the screen.
If there is no video signal at the Video IN port of the CCTV
Tester, the type of NTSC or PAL , and Video
Level will not be displayed.
Depending on the type of camera connected to the CCTV Tester, the Video “Format: “ will automatically change
between NTSC and PAL, and the Video Level will automatically change between IRE (Institute of Radio Engineers)
and mV.
NTSC signal is measured in IRE units, PAL signal is measured in mV.
The Video Level should be within the indicated range.
Levels that are too low will result in a dim picture with reduced dynamic range. A Video Level that is too high will
result in washed out pictures with decreased quality.
The CCTV Tester will display “Normal” when video levels are 1000mV±20%, “Exceed” or “Weak” will be displayed
when video level out of 1000mV±20%.
12
2.5 Colorbar generator (Output video at any mode)
Output or receive seven different forms of video color bar to test monitor, video cable or other equipment.
a. Press the
or
key to select the parameter which we
want to change the value.
b. Press the
or
key to change the value.
c. Press ENTER key to save the change or press RETURN
key to give up the change.
2.6 Cable Tester
Test LAN cable or telephone cable.
Connect LAN cable or telephone cable with the CCTV tester and cable tester. And then the connecting status,
cable type and the sequence of wires will be displayed, as well as the serial number of the cable tester kit.
The right picture shows line1-7 are closed, line8 is open and the number of the cable tester box is 255.
13
2.7 Data monitor
Capture the command data from RS485 controlling system (for example : keyboard, DVR).
a.Connect the RS485 or RS232 interface of controlling
system with the RS485 or RS232 interface of the CCTV
Tester (In case of RS485, A to A, B to B).
b.Press SET key and then press
or
key to select
communication port according to the system connection.
Press SET key to save the change.
c.Press
or
key to select the baud rate according to
the baud rate of
controlling system and then press SET
key to save the change and capture command data from
controlling system.
d.Press RETURN key to clear the screen.
2.8 Device setting
Set the parameters of the CCTV Tester
Auto poweroff:
Setting the time of auto shut-down. (Disable, 5, 10,…, 60).
Disable: disable the “Auto poweroff” function. 5 means the
CCTV will power off after 5 minutes when there is no any
operation.
Adress search off :
Keypad tone: open or close the beep of pressing keypad.
Language: select language of OSD menu.
Brightness: setting the brightness of OSD menu and
background (0~7).
a.Press
or
key to move the parameter we want to
change.
b. Press
or
to change the value.
c. Press ENTER to save the change or press RETURN key to
give up the change.
14
2.9 PTZ address scanning
Search up the ID of PTZ camera.
Note: Please isolate the PTZ camera with other PTZ cameras before searching up.
Otherwise all the PTZ cameras in the same system will pan at the same time.
Press
NEAR: keys to “Device setting” menu:
Press
key to confirm after change “Address search:” to
“on”, which add address scan sub-menu. Press
to switch
the sub-menu as illustrated:
Note: The system returns to “OFF” after shutdown and the scan
sub-menu closes automatically. Set “ON” again for next use.
Press
key to set: protocol, communication port,
communication rate, make them same as the PTZ camera.
Press
or
key, the address values are constantly on the
rise or decrease.
(from 1 to 256). When the ID is found,
The tester will search up the ID quickly and continuously
the PTZ camera will pan right. At this time, please press any key to stop searching up.
will search up the ID quickly and continuously (from 256 to 1).
FAR: The
tester
When the ID is found, the PTZ camera will pan left.
At this
time, please press any key to stop searching up.
WIDE: The tester will search up the ID step by step (from 1 to 256).
When the ID is found, the PTZ camera will stop panning.
Press the direction control button to adjust Speed Dome Camera.
Press
button to quit from the address-scanning function menu.
15
3. Specifications
Video Test
Signal mode
NTSC/PAL (Auto adapt)
Display
2.8 inch digital TFT-LCD, 960 x 240 resolution
LCD adjustment
Brightness, Contrast, Saturation adjustable
Video IN/OUT
1 channel BNC Input & 1 channel Output
Video Output Mode
1.0 Vp-p
Video Level test
Video signals measured in IRE or mV
PTZ controller
Communication
RS232, RS422 simplex and RS485
PTZ Protocol
Compatible with more than 20 protocols such as PELCO-D/P, Samsung,
Panasonic, Lilin, Yaan, etc.
Baud Rate
150, 300, 600, 1200, 2400, 4800, 9600, 19200 bps
Video Signal Generation
Color bar generation
Output channel color bar video signal for testing monitor or video cable
UTP cable test
Test UTP cable connection status and display in the screen. Read the number of the
test box.
RS485 data analyst
Data Monitor
Captures and analyzes the command data from controlling device
POWER
Power Adapter
DC5V, 2A
Battery
Built-in 3.7V Lithium polymer battery, 2000mAh
Rechargeable
After charging 3-4 hour, working time lasts 11 hours
Low Consumption
Energy saving technology
General
Working Temperature
-25°C + 70°C
Working Humidity
30% - 90%
Dimension/Weight
166 mm x 95mm x 48mm/293g
16