All Threaded Connections are 3/4” NPT
Dimensions are in Inches and Approximation of a Typical Installation
Common tools needed:
General Characteristics
In case of instantaneous heaters, hot water flow has to at least meet flow required by heater and maintain burning. (Specified
by heater manufacturer)
Operating Specifications
Hot water supply temperature:
Maximum: Reference manufacturing specification
Minimum: 140°F
Minimum difference between hot and mixed temperature is: 50°F
Operating Pressure:
Maximum: 70 PSI
Minimum: 20 PSI
Operating pressure (on hot and cold line) should be kept as balanced as possible in order to assure maximum efficiency.
When the pressure is greater than 70 PSI, a pressure reducer is required and must be fitted before valve.
Technical Data
The temperature control knob is graduated from 75°F to 120°F with auto stop at 100° to avoid scalding.
Temperature limit setting of less than 120°F.
Fit a stop valve/volume control between thermo valve outlet and end device(s).
Plumbing Recommendations
• An independent water supply for both hot and cold is required. Do not pipe off ring main.
• Large runs of pipe work will cause frictional loss of pressure.
• The recommended main water supply piping to valve shall be 3/4” minimum.
• If more than one valve is installed, the recommended main water supply piping to valve shall be 1” minimum, reducing to 3/4”
within 24” of each valve.
(Ensure adequate supply from both hot and cold water can be maintained.)
Water By-Laws
The mixing valve should be installed in compliance with the water by-laws. For further details refer to the latest copy of bylaws guide or your local water authority.
1. Rough in Valve Installation
Figure 1
Figure 2
Shim
Cross support
Wall stud
••
••
•
Note: Use Teflon tape or equivalent to seal all threaded port joints.
Do not remove mud cover from valve before locating mounting surface depth in the wall.
Do not turn the cartridge stem - temperature settings are pre-calibrated at the factory.
Install plug into one of the two outlet ports. Note: For proper valve operation only one outlet port may be used.
Mount valve to cross support using shims and screws (not included). Valve shall be perpendicular and fixed
firmly to cross support to achieve proper trim attachment.
Place the cross support with valve between wall studs. The min./max. valve exposure template on the mud
cover and vertical height desired within tub/shower enclosure determines the exact cross support placement.
Attach cross support to wall studs.
Cartridge stem
DO NOT TURN
Maximum exposure
Plug
Finished wall
Mud cover
template
Minimum exposure
Mud cover
3
2. Connecting Water Supply
••
••
•
•
Thoroughly flush supply lines to remove any debris, metallic shavings, flux, etc.
Shut off water supply to valve.
Hot and cold water supplies MUST be connected to designated sides for proper operation of valve.
If solder/brazing the fitting connections, pre-assembly hot & cold adapter fittings to copper piping. Using
Teflon tape or equivalent to attach adapter to appropriate inlet port.
Important: All excessive heat shall be a minimum of 4” from valve.
Connect outlet pipe to stop valve/volume control (not included), and from stop valve pipe to various end
device(s).
Turn on water supply to valve and check for leaks.
Outlet pipe
for shower
connection
4” m
in.
Hot water
supply
Cartridge stem
(DO NOT TURN)
Cold water
supply
Figure 3
4
3. Installing Trim & Temperature Setting
••
••
•
•
•
••
Remove and discard mud cover and screws.
Slide sleeve over valve body with grooved notch to topside.
Slide cover plate with gasket over sleeve and attach with decorative screws provided (see Figure 4).
Orient and position limit stop as shown in Figure 5. Slide Nomenclature ring over sleeve, aligning 100° to
notch in sleeve.
Open shut-off valve and verify water temperature at outlet device by using a thermometer. NOTE: The safe
and factory set temperature is 100°F. The next step refers to adjustment of the temperature, otherwise skip
to the following step.
Rotate cartridge stem to adjust temperature:
(clockwise = colder or counterclockwise = hotter)
Place bonnet onto cartridge stem with red button (100°F) positioned straight up and inline with notch on the
sleeve (see Figure 6).
Place decorative handle onto bonnet and secure with screw.
Remove adhesive tab from cap and press onto top of handle.
Valve
Sleeve
Coverplate
Figure 4
Stop ring
Nomenclature
ring
Bonnet
Cartridge
stem
Handle
Cap
Figure 5
Figure 6
5
4. Maintenance and Troubleshooting
•
••
••
•
••
••
The thermostatic valve has various screens that filter debris and unwanted particles that may damage the
valves' cartridge and operation. Through years of use, these screens may build up with impurities and
limescale, restricting the flow of water through the cartridge and or check valves. The following steps
describe removal and cleaning procedure.
Cartridge
(Reference Figure 7)
Carefully remove the handle, bonnet, stop ring, cover plate and sleeve.
Shut off the water to cartridge by tightening center screw on each check valve, 7 turns maximum.
Unscrew the cartridge using 1-3/16” or adjustable wrench; gently remove cartridge from housing.
Clean the screens by rinsing the cartridge under running water. If necessary, soak in a 50/50 mix of white
vinegar and water to remove limescale.
Wipe cartridge and housing with wet cloth and apply a thin film of non-petroleum grease to o-rings. Do not use
Vaseline.
Carefully install cartridge into housing and tighten to 10 ft-lbs.
Fully open check valves and inspect for leaks.
Check operation and flow. If improved, proceed to step 9, otherwise see checkvalve section below.
Reinstall trim and set temperature per section 3.
Cartridge
Sleeve
Stop ring
Check
valve
Bonnet
O-rings
Coverplate
Handle
Figure 7
6
Screens
5. Check valve
••
••
••
••
(Reference Figure 8)
Turn water supply to valve inlets off.
Tighten center screw on check valve inward until it clears bottom on check valve slot.
Unscrew check valve with large bladed screwdriver.
Remove check valve and clean per step 4 and 5 above.
Replace valve back into housing, unscrew center and re-close to 7 turns max.
Turn on water supply to valve inlets.
Fully open the check valve screws and inspect for leaks.
Reinstall trim and set temperature per section 3.
Check valve
O-ring
Filter
Figure 8
7
Care and Cleaning
The lustrous finish on your Restoration Hardware Bathware fixture should
be treated with care. Improper handling or cleaning can damage the surface
of any metal finish. Use a soft cloth to wipe clean. Avoid harsh abrasive
cleaners. Water contains lime and other mineral deposits that will be left on
the surface after the water has evaporated. You can prevent these deposits
from forming by always wiping the fixture dry immediately after use.
Technical Support and Customer Service
For technical support in the installation of your Restoration Hardware
Bathware fixture, please call 1-866-417-5207 weekdays between the hours
of 7:00am and 4:00pm PST.
For other questions regarding your order, to order additional components of
the Restoration Hardware Bathware Collection, to order replacement parts,
or to address warranty issues, please contact Restoration Hardware
Customer Service at 1-877-747-4671.
8
Thermostatic
shower systems
Thermostatic Shower Valve & Trim
f e at u r e s & b e n e f i t s
•Solid brass components.
•Sixteen gallons/minute flow rate supports up
to three water outlets running simultaneously.
•Temperature control only. Installation of
thermostatic valve also requires the purchase
and installation of flow control valve(s) – sold
separately. One flow control valve is needed
for each water outlet in your shower system. (Showerhead, handheld shower, etc).
•User accessible, adjustable maximum water
temperature selection.
•3/4" Thermostatic Rough-in Valve, includes
trim to match collection.
•Paraffin cartridge, Built-in check valves with
service stops, NPT threading Meets ASSE
Standard 1016, IAPMO and CSA Listed.
Other Components (sold separately):
•Flow control valve & trim set.
-On/off valve that controls water flow.
-One valve needed per water outlet, allows for more than one outlet at a time.
•Valve trim extension kit. Extends valve an
additional 1-3/8" from wall. Includes spine
extension, lock washer and handle screw.
Shower Only
parts required
• Thermostatic valve & trim set
• Flow control valve & trim set
• Showerhead, flange & arm
Shower with
Handheld Shower
parts required
• Thermostatic valve & trim set
• Flow control valve & trim set (2)
• Showerhead, flange & arm
• Handheld shower
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising