Digital Multimeters/Clamp Meters/Voltage and Continuity Testers

Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
CLAMP METERS
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
CLAMP METERS
Selection Guide for Clamp Meters
Part No.:
MD 9272
True RMS
DC current range
Basic accuracy (%)
AC current range
Basic accuracy (%)
DC voltage range
Basic accuracy (%)
AC voltage range
Basic accuracy (%)
MD 9250
MD 9240
MD 9235




−
2000 A
−
−
MD 9230
MD 9225
MD 9220
MD 9210



−
1000 A
400 A
−
−
−
2.0
−
−
1.5
1
−
−
100 A
2000 A
1000 A
600 A
800 A
400 A
2000 A
600 A
0.8
2.0
1
1
1.5
1
1.5
1.5
−
1000
600 V
600 V
600 V
600 V
600 V
600 V
−
0.5
0.5
0.5
0.3
0.3
0.5
0.3
600 V
1000
600 V
600 V
600 V
600 V
600 V
600 V
0.5
1.2
0.5
0.5
1
1
1.5
1.5
Resistance range
−
40.00 MΩ
999.9 Ω
999.9 Ω
40.00 MΩ
40.00 MΩ
6.000 MΩ
40.00 MΩ
Basic accuracy (%)
−
Acoustic continuity test
−
0.5

1

1

0.6

0.8

1

0.6

Diode test
−

−
−




Capacitance measurement
−




−

−


Frequency measurement
−

−



Temperature measurement (Type K probe)
−


−
−

Autocheck® V-Ω
−

Auto V-A
−
−
Auto V-A
−

−
−
Variable frequency drive
−

−
−
−
−
−
−
Lo-Z (low input impedance)

−

−
−
−
−
−

−
Power measurement (W, VA, VAR)
−

−
−
−
−
3-Phase Power measurement 3-wire/4-wire
−
−
−

−
−
−
−
3000

6000

4000, 6000, 9999

6000

4000

4000

6000

4000
−



−
Auto

Auto

Auto

−

Auto

−

−

−

−


−
−

−
−



−

−

Peak value
−

−


MAX hold
Data hold




−

−

−

−

Count
Backlight
COM port (data transfer)
Automatic and manual range selection
Automatic switch off
Non-contact electrical field detection

−
Auto

Relative value
−

−
−


Jaw opening
31 mm
55 mm
45 mm
26 mm
50 mm
26 mm
45 mm
26 mm
Overvoltage category
CAT IV / 300 V
CAT III / 600 V
CAT IV / 1000 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
CAT IV / 300 V
CAT III / 600 V
Dimensions (mm)
190 x 60 x 13
264 x 97 x 43
224 x 78 x 40
189 x 78 x 40
227 x 78 x 40
188 x 63 x 40
224 x 78 x 40
190 x 63 x 32
255

608

224

192

290

192

220

139

Weight (g)
CE mark
7. 16
Accessories: page 7.32
Accessories: page 7.32

7. 17
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
CLAMP METERS
Digital Multimeters/Clamp Meters/Voltage and Continuity Testers
CLAMP METERS
MD 9272 Leakage Clamp TRMS Meter with Power Functions
MD 9250 Industrial TRMS AC/DC CAT IV /1000 V
The MD 9272 is a unique earth leakage clamp meter. It not just has the ability to accurately read the TRMS AC leakage
current of a system, it can also detect losses in the system and suggest possible reasons for the loss. The voltage, power,
harmonic, power factor (PF), total harmonic distortion (THD) and crest factor measurements make this instrument suitable
for any electrician and engineer.
The MD 9250 is the first Clamp Meter that meets overvoltage category CAT IV 1000 V. MD 9250 is a high quality clamp
meter specially designed for single-hand operation, built-in measuring functions; TRMS AC/DC (current, voltage), capacitance, temperature and full range resistance makes this instrument an ideal tool for the most demanding applications in
the industrial sector. The large jaws capacity of (max. 55 mm) in diameter allows AC/DC - current measurements up to 2000
A. High resolution and accuracy, 2-line LCD display fast data acquisition and transfer (via optical interface), non-contact
voltage detection, and auto-check function are highlights of the instrument.
MEASURING FUNCTIONS:
MEASURING FUNCTIONS:
•TRMS AC voltage measurement;
•TRMS AC current measurement;
•Frequency measurement;
•Power parameters measurement.
•TRMS AC, DC voltage measurement;
•TRMS AC, DC current measurement;
•Capacitance measurement;
•Resistance measurement;
•Diode test;
•Frequency measurement;
•Electric field detection;
•Continuity test (acoustic signaling);
•Temperature measurement.
KEY FEATURES:
• TRMS: accurate measurements on sinusoidal and non-sinusoidal signals.
• Jaw size: 28 mm.
• Shielded Jaw: shielded jaw allows the
clamp meter to be used in the noisiest
environments.
• Accurate: readings of AC current with an
accuracy of 0.8 % and a base resolution
of 0.01 mA and voltage with an accuracy
of 0.5 % and a base resolution of 0.1 V.
• Power: measures various power parameters (active, reactive, apparent
power, THD, PF, phase displacement).
• Intelligent loss analysis: complex algorithms detect loss and allow determining possible reasons for current loss.
• Harmonics: measures current or voltage
harmonic components and a percentage
value of a harmonic up to the 49th.
• THD and PF: dual display allows readings
to be displayed along with Total Harmonic Distortion (THD) or Power Factor (PF).
• Peak value: the peak value of the waveform or crest factor can be displayed.
• MAX/MIN/HOLD mode: displays maximum, minimum or average measured value.
KEY FEATURES:
APPLICATION:
TECHNICAL SPECIFICATION:
•Load and leakage current measurement;
•System maintenance;
•Power system checking;
•RCD fault finding;
•Process engineering.
Function
AC current
STANDARD SET:
AC/DC voltage
•Current clamp MD 9272
•Test lead with probe, 2 pcs
•1.5 V battery, type AAA, 2 pcs
•Pouch
•Instruction manual
•Warranty
THD
7. 18
Power factor (PF)
Range
40.00 mA, 400.0 mA, 4000 mA
40.00 A
150.0 A
40.0 V
400.0 V, 600.0 V
0 … 99.9 %
100 … 999 %
1.00 … 2.99
3.00 … 9.99
40.00 … 100.0 A
40.00 … 600.0 V
0.00 … 1.00
Accuracy
±(0.8 % of reading + 3 digits)
±(1.0 % of reading + 3 digits)
±(1.2 % of reading + 3 digits)
±(0.5 % of reading + 4 digits)
±(0.5 % of reading + 2 digits)
±(2.0 % of reading + 3 digits)
±(2.0 % of reading + 3 digits)
±(2.0 % of reading + 2 digits)
±(3.0 % of reading + 5 digits)
±(3.0 % of reading + 3 digits)
±(3.0 % of reading + 3 digits)
±(1.0 % of reading + 0.01)
Phase
-180.0° … +180.0°
±(1.0 % of reading + 0.4)
Power (W, Var, VA)
0 … 9999
±(1 % of reading + 30)
Power (kW, kVar, kVA)
10.00 … 99.99
±(2 % of reading + 30)
Power supply
2 x 1.5 V batteries, type AAA
Overvoltage category
CAT IV / 300 V; CAT III / 600 V
Dimensions
190 x 60 x 43 mm
Weight
255 g
Crest Factor
Peak value
•Large jaws: for measuring on 55mm
size conductors.
•TRMS: accurate measurements on sinusoidal and non-sinusoidal signals.
•VFD: feature makes the instrument capable of measuring the true values in
accordance with frequency.
•High current: 2000 A DC & AC clamp
on measurement.
•Lo-Z: AutoCheck® mode provides low
(ramp-up) input impedance to drain
ghost voltages.
•Auto-check function: automatic detection
of AC voltage, DC voltage or resistance.
•Auto-ranging: user can switch between auto and manual ranging.
•Transient protection: it protects user
in case of lightning strike or switching
surge up to 12 kV.
•Relative zero mode: relative function
for comparing the difference between
signals or removing background noise.
•PC Link: test results can be downloaded to
the computer via the optional PC software.
•In-rush: fast 5ms Crest-MAX mode to
capture in-rush currents.
•Temperature: measures temperature
in Celsius up to 1000 °C and in Fahrenheit up to 1832 °F.
•Hold: data hold function freezes the
display for later view.
•Backlight: large bright 3-5/6 digits 6,000
counts + 1,999 counts dual LCD display with
backlight for working in dark conditions.
•Safe: CAT IV / 1000 V overvoltage protection.
APPLICATION:
•Solar and wind power system testing;
•UPS system testing;
•Utility scale battery system testing;
•High level industrial testing;
•High level electrical testing.
Function
DC Voltage
Autocheck (DCV)
AC Voltage (50 Hz … 400 Hz)
AC+DC Voltage (DC, 50Hz … 400 Hz)
Autocheck (ACV)
Variable Frequency Drive AC
DC Current
AC Current (50 Hz … 400 Hz)
Diode Test
Resistance & Autocheck
Capacitance
STANDARD SET:
•Current clamp MD 9250
•Test lead with probe, 2 pcs
•Thermocouple probe, type K
•Pouch
•1.5 V battery, type AAA, 2 pcs
•Instruction manual
•Warranty
Accessories: page 7.32
TECHNICAL SPECIFICATION:
Accessories: page 7.32
Temperature
Mains frequency
Power supply
Overvoltage category
Dimensions
Weight
Range
6.000 V … 1000 V
6.000 V … 1000 V
6.000 V … 1000 V
6.000 V … 1000 V
6.000 V … 1000 V
Accuracy
±(0.5% of reading + 5 digits)
±(1.3% of reading + 5 digits)
±(1.2% of reading + 5 digits)
±(1.4% of reading + 7 digits)
±(1.5% of reading + 5 digits)
from ±(4.0% of reading + 80 digits)
10 Hz … 400 Hz
to ±(7.0% of reading + 80 digits)
From ±(2.0% of reading + 5 digits)
200.0 A … 2000 A
to ±(2.5% of reading + 5 digits)
from ±(2.0% of reading + 5 digits)
200.0 A … 2000 A
to ±(3.5% of reading + 5 digits)
1.000 V
±(1.0% of reading + 3 digit)
Open-circuit voltage < 1.8 V DC, Test current 0.56 mA
from ±(0.5% of reading + 5 digits)
600.0 Ω … 40.00 MΩ
to ±(2.3% of reading + 5 digits)
from ±(2.0% of reading + 5 digits)
60.00 nF … 2000 µF
to ±(4.0% of reading + 5 digits)
-50 °C … 1000 °C
±(0.3% of reading + 4 digits)
-58 °F … 1832 °F
±(0.3% of reading + 6 digits)
10 Hz … 1999 Hz
±(0.1% of reading + 4 digits)
2 x 1.5 V batteries, type AA
CAT IV / 1000 V
264 x 97 x 43 mm
608 g
7. 19