Installation Instructions

Installation Instructions
Installation Inst ru ct io n s
SELECTRONIC®
MODEL NUMBERS
CONCEALED TOILET FLUSH VALVE
606B.3XX
1.1, 1.28 & 1.6 GPF
Exposed Back Spud
Concealed Back Spud
Top Spud
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Certified to comply with ASME A112.19.2
© 2016 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093)
© 2016 AS America Inc.
1
M965642 Rev. 1.5 (11/16)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your
installation proceeds smoothly--please read these instructions carefully before you begin.
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
UNPACKING
Remove the Flush Valve items from the carton. The illustration below shows all items after they have been
removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions
2. Flush Valve Body Assembly
3. Cover Plate with Sensor
4. Wall Box
5. Sweat Adapter
6. Stop Valve
7. Manual Override Hoses
8a. Vacuum Breaker Flush Connection
(Exposed Back Spud)
8b. Vacuum Breaker Flush Connection
(Concealed Back Spud)
8c. Vacuum Breaker Flush Connection
(Top Soud)
9. Safety Chain
POWER KITS — SOLD SEPARATELY
4
3
1
9
7
6
I n s t a l l a t i o n I n s t ru c t i o n s
DO NOT REMOVE PROTECTIVE
FILM FROM SENSOR
EYE UNTIL INSTALLATION
IS COMPLETE.
SELECTRONIC™CONCEALED
TOILET FLUSH VALVE
1.28 & 1.6 GPF
Exposed Back Spud
Certified to comply with ASME A112.19.2
© 2016 AS America, Inc.
Concealed Back Spud
PWRX
Power Kit
PK00.WRK
Plug-In AC
Power Kit
PK00.PAC
Hard-Wired AC
Power Kit
PK00.HAC
MODEL NUMBERS
606B.3XX
Top Spud
CAUTION: Use only American Standard supplied cable
sets. Using non-AS supplied cables, or cutting, splicing or
modifying any components will void the warranty.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
2
(In Toronto Area only: 1-905-306-1093)
5
VACUUM BREAKER FLUSH CONNECTIONS
6065.XXX
8a
6067.XXX
8b
6068.XXX
Multi-AC
Power Kit
8c
CR-P2 Battery
Power Kit
PK00.MAC
2
M965642 Rev. 1.5 (11/16)
Fig. 1
GENERAL DESCRIPTION:
Roughing-in
Dimensions
SELECTRONIC® PROXIMITY TOILET
FLUSH VALVE
Concealed Flushometer for 1-1/2"
Top Spud Fixtures
25 mm (1") MAX.
404 mm
(15-7/8")
WALL THICKNESS
389 x 265 mm
(15-5/16" x 10-3/8")
ROUGH OPENING FOR BOX
CAUTION: Use only American Standard
supplied transformers and cable sets.
Using non-AS supplied cables, or cutting,
splicing or modifying any components will
void the warranty.
FINISHED WALL
15˚
SENSOR
DETECTION ZONE
400 -800 mm
(Factory Setting: 400 mm)
OVERRIDE
BUTTON
280 mm
(11")
FOR LOCATION OF INLET SUPPLY ON BACK INLET
FIXTURES AND CORRECT HEIGHT FROM FINISHED FLOOR,
REFER TO FIXTURE INSTRUCTION SHEET.
SUPPLY
(1") NPT
-C-L-
-C-L-
TOP SPUD
TOILET
108 -134 mm
(4-1/4" to 5-1/4")
70 mm
(2-3/4") DIA.
*-C-L152 mm
(6") MIN.
EXPOSED BACK
SPUD TOILET
176 mm MAX.
(6-15/16") MAX.
51 mm
(2")
TOP OF
FIXTURE
400 mm MAX.
(15-3/4") MAX.
450 mm MAX.
(17-3/4") MAX.
128 mm MAX.
(5") MAX.
CONCEALED BACK
SPUD TOILET
*-C-L152 mm MIN.
(6") MIN.
TOP OF
FIXTURE
TOP OF
FIXTURE
51 mm
(2")
51 mm
(2)
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6 " (152 mm) min.
above fixture. Consult Codes for details.
240 mm MAX.
(9-1/2") MAX.
FINISHED
FLOOR
RECOMMENDED TOOLS; Fig. 2.
Fig. 2
1. Teflon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5 mm Hex Wrench
10. 1.5 mm Hex Wrench
2
1
3
4
10'
6
8
5
7
9
10
PRIOR TO INSTALLATION
• Flush all water lines prior to operation (see Step 3).
Dirt and debris can cause flush valve to run continuously.
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Toilet
2. Drain line
3. Water supply line
• With the exception of Stop Valve Inlet, DO NOT
use pipe sealant or plumbing grease on any
valve component or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see “Care and Cleaning”
section of this manual.
IMPORTANT:
•A
ll plumbing and electrical wiring should be
installed in accordance with applicable codes
and regulations.
• The use of water hammer arrestors is strongly recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
3
M965642 Rev. 1.5 (11/16)
FLUSH VALVE INSTALLATION
Fig. 3 (TOP SPUD FIXTURE ILLUSTRATED)
389 mm
(15-5/16")
ROUGH OPENING IN WALL
LEVEL
1 INSTALL WALL BOX; Fig. 3
1. Frame out a 389 mm x 265 mm (15-5/4" X 10-3/8") rough
opening in wall for the WALL BOX (1) at the dimension
shown.
2. Fasten one end of the SAFETY CHAIN (2) and CLIP
(4) to the WALL BOX (1) with NUT & SCREW (3) provided.
265 mm
(10-3/8")
3
1
2
3. Install the WALL BOX (1) into rough opening in the wall
Level and secure the WALL BOX (1) to the wall opening
with screws.
Important: Front face of WALL BOX (1) should be flush
with finished wall.
4
176 mm MAX.
(6-15/16") MAX.
*FOR HOLE LOCATION OF
SUPPLY ON BACK INLET
FIXTURES, REFER TO FIXTURE
BEING INSTALLED FOR CORRECT
HEIGHT FROM FINISHED FLOOR
128 mm MAX.
(5") MAX.
4. Cut a 2" hole for outlet pipe at dimension shown.*
2
INSTALL SWEAT ADAPTER; Fig. 4
CAUTION
Fig. 4
Turn water supplies off before
beginning
115 mm-134 mm
(4-1/2" TO 5-1/4")
2
1
STOP VALVE
(1"NPT)
FILE
EDGES
Note: Stop Valve inlet is 1" NPT. For optional sweat
connection, install Sweat Adapter (1) (Supplied) for 1"
copper pipe supply line.
CLEAN & SOLDER
TO ADAPTER (1)
1. Clean the end of the supply pipe. Push the threaded
SWEAT ADAPTER (1) until it is seated against the
internal stop. Sweat the ADAPTER (1) to the pipe.
STOP VALVE OUTLET
2. Install the STOP VALVE (2) to the water supply line
with the outlet positioned as required (Behind the Wall).
3. Support piping as required.
3
F
LUSH OUT SUPPLY LINES; Fig. 5
1. Open STOP VALVE (1).
Fig. 5
COUNTER-CLOCKWISE
OPENS STOP VALVE
2. Turn on water supply line to flush line of any debris or
sediment.
CLOCKWISE CLOSES
STOP VALVE
1
3. Close STOP VALVE (1) and turn off water supply line.
4
M965642 Rev. 1.5 (11/16)
4
I NSTALL VACUUM BREAKER AND
FLUSH CONNECTIONS; Fig. 6
Fig. 6
2
3
1. Place the SPUD FLANGE (1) over the spud on the Fixture. Fig. 6.
4
1
1-1/2" TOP SPUD
2. Place FRICTION WASHER (3) and SEAL WASHER (4) inside
SPUD COUPLING NUT (2) and thread onto Spud. Do not tighten
fully. Fig. 6.
3. Remove the ELBOW COUPLING NUTS (6, 6a) from the CHROME
ELBOW (5). Make sure you have a TAPERED RUBBER WASHER
(7), PLASTIC SUPPORT (8) and SQUARE SEAL WASHER (9).
Fig. 6a.
Fig. 6a
7
6a
5
TAPERED SIDE
8
9
4. Install the SQUARE SEAL WASHER (9) onto the PLASTIC
SUPPORT (8) if not already installed. Insert the PLASTIC
SUPPORT (8) into the VERTICAL OUTLET PIPE (10). Slide the
ELBOW COUPLING NUT (6) onto the VERTICAL OUTLET PIPE
(10). Connect the ELBOW COUPLING NUT (6) to the CHROME
ELBOW (5) and tighten fully.
5. Insert the VERTICAL OUTLET PIPE (10) with assembled CHROME
ELBOW (5) into the SPUD COUPLING NUT (2) and push it down.
Do not tighten fully. Fig. 6a.
FLANGE END UP
TOP SPUD
INSTALLATION
16
TAPERED
SIDE
FLANGE END
BACK SPUD
INSTALLATION
Important: Make sure that there is a minimum of 1-1/4" for
engagement with elbow when making your measurement.
9. For back spud installations: Follow steps #1 and #2 to install the
spud coupling kit. Push the HORIZONTAL OUTLET PIPE (11) into
the spud connection on the back of the fixture. Do not tighten fully.
If spud coupling kit is not required, install HORIZONTAL OUTLET
PIPE (11) into back spud on fixture and hand tighten. Fig. 6b.
15
13
12
6. Measure and cut the HORIZONTAL OUTLET PIPE (11) to length
required. Fig. 6b.
8. From behind the wall, insert the assembled BRASS ELBOW and
HORIZONTAL OUTLET PIPE (12, 11) through the hole in the wall.
Install WALL ESCUTCHEON (16) onto the HORIZONTAL OUTLET
PIPE (11). Slide the ELBOW COUPLING NUT (6a) and TAPERED
RUBBER WASHER (7) onto the HORIZONTAL OUTLET PIPE (11).
Push the HORIZONTAL OUTLET PIPE (11) into the CHROME
ELBOW (5). Tighten ELBOW COUPLING NUT (6a) but not fully.
Fig. 6b.
2
Fig. 6b
Note: Cutting the VERTICAL OUTLET PIPE (10) may be necessary
for the CHROME ELBOW (5) center line to line up with opening in
the wall.
7. Remove the ELBOW COUPLING NUT (14) from BRASS ELBOW
(12) and slide it onto the HORIZONTAL OUTLET PIPE (11). Install
the SQUARE SEAL WASHER (13) onto the PLASTIC SUPPORT
(15) if not already installed. Insert the PLASTIC SUPPORT (15) into
the HORIZONTAL OUTLET PIPE (11). Connect the ELBOW
COUPLING NUT (14) to the BRASS ELBOW (12) and tighten fully.
Fig. 6b.
6
10
14
11
6a
11
7
5
Fig. 6c
BACK SPUD
INSTALLATION
TOP SPUD
INSTALLATION
17
14a
19
TAPERED SIDE UP
TAPERED
SIDE UP
19
12
10. All installations: If required, cut scored VACUUM BREAKER PIPE
(17), leave a minimum of 1-1/4" (32 mm) of pipe to ensure
engagement with compression coupling. Assemble the ELBOW
COUPLING NUT (14a) and TAPERED RUBBER WASHER (19)
onto the VACUUM BREAKER PIPE (17). Install VACUUM
BREAKER PIPE (17) into BRASS ELBOW (12) and hand tighten
COUPLING NUT (14a). Fig. 6c.
Note: If cutting VACUUM BREAKER PIPE (17) to size, note that
Critical Line (C/L) on Vacuum Breaker must typically be 6"
(152mm) above fixture. Consult Code for details.
5
M965642 Rev. 1.5 (11/16)
5 INSTALL FLUSH VALVE; Fig. 7
Fig. 7
1. Insert the side ADJUSTABLE TAILPIECE (1) on the
FLUSH VALVE (2) into the STOP VALVE (3). Lubricate
the TAILPIECE O-RING (4) with water if necessary.
Thread the COUPLING NUT (5) onto the STOP VALVE
(3) and tighten lightly. Fig. 7.
1
3
Important: Do not use lubricants (other than water)
or any type of thread sealing paste or tape.
5
2
6 CONNECT FLUSH VALVE TO
Fig. 8
VACUUM BREAKER TUBE; Fig. 8
4
121 m m,+13 mm,-6 mm
(4-3/4")(+1/2", -1/4")
1. Align the FLUSH VALVE (2) (Fig. 9) directly above
the VACUUM BREAKER TUBE (7) and VACUUM
COUPLING NUT (6). Make sure that GASKET (10) is
installed.
Note: There is a +13 mm, -6 mm (+1/2"-1/4") tolerance
for the 121 mm (4-3/4") dimension.
2
2. Pull the VACUUM BREAKER TUBE (7) up to meet the
8
threaded FLUSH VALVE CONNECTION (8) and hand
tighten the COUPLING NUT (6). Align all components
of the flush valve assembly.
5
10
6
3. Lightly tighten the TAILPIECE COUPLING NUT (5)
connection first, then the VACUUM BREAKER
COUPLING NUT (6) and finally the SPUD COUPLING
NUT (9). Once alligned correctly, use a wrench to
tighten all couplings to make water tight connections.
7
4. Secure piping with in wall as required.
9
6
M965642 Rev. 1.5 (11/16)
ELECTRICAL INSTALLATION
Fig. 9
Fig. 9
7 STANDARD BATTERY POWER
3
3
KIT (PK00.CRP); Fig. 9, 9a
1. Connect one end of the 27" EXTENSION CABLE (1) to
a SENSOR CABLE (2). Connect the other end of the 27"
EXTENSION CABLE (1) to the SOLENOID CABLE (3).
Fig.9.
2
2
2. Insert BATTERY (6) into BATTERY HOLDER (7), making
sure terminal side is inserted first. Fig.9a.
1
1
3. Connect BATTERY HOLDER (7) to available SENSOR
CABLE (5) and install the CONNECTOR LOCKING
DEVICE (7). Place BATTERY HOLDER (7) into electrical
box. Fig.9a.
Fig. 9a
Fig. 9a
7a PWRX POWER KIT (PK00.WRK);
Fig. 9, 9a
1. Connect one end of the 27" EXTENSION CABLE (1)
to a SENSOR CABLE (2) and install the CONNECTOR
LOCKING DEVICE (10) on battery - sensor connection.
Connect the other end of the 27" EXTENSION CABLE
(1) to the SOLENOID CABLE (3). Fig.9.
2. Insert BATTERY (6) to available SENSOR CABLE (5).
Place BATTERY (6) to electrical box. Fig.9a.
4
4
Move highlighted
text here
7
7
5
5
TERMINAL SIDE
TERMINAL SIDE
6
6
7
M965642 Rev. 1.5 (11/16)
8
AC VERSION (PK00.PAC POWER
KIT); Fig. 10, 10a
Fig. 10
Fig. 10
1. Connect one end of the first 27" EXTENSION CABLE (1)
to SENSOR CABLE (5). Connect the other end of the 27"
EXTENSION CABLE (1) to the SOLENOID CABLE (3).
Fig.10.
2. Connect AC POWER SUPPLY (2) to the SINGLE AC
ADAPTER (10). Fig.10.
3
3
5
5
6
6
1
1
4
4
3. Connect the second 27" EXTENSION CABLE (1) to
the SINGLE AC ADAPTER (10), and the other end
of the 27" EXTENSION CABLE (1) to available
SENSOR CABLE (6). Fig.10.
10
10
4. Plug AC POWER SUPPLY (2) into outlet. Fig.10a.
ELECTRICAL
ELECTRICAL
OUTLET
OUTLET
2
2
5. Place SINGLE AC ADAPTER (10) into electrical box.
FOR HARD-WIRED VERSION
(PK00.HAC POWER KIT) Fig. 10b
Fig. 10a
Fig. 10a
6. Contractor to supply ELECTRICAL BOX (11).
7. Connect black and white power line connections to
HARD-WIRED AC TRANSFORMER (12) and mount
into ELECTRICAL BOX (11). Fig. 10b.
NOTE: CONNECTOR LOCKING DEVICE not used
for AC installation.
2
2
Fig. 10b
2
2
10
10
11
7
BLACK & WHITE
POWER
CONNECTIONS
ELECTRICAL
OUTLET
8
ELECTRICAL
OUTLET
CONNECTOR NOT
12ELECTRICAL
OUTLET
USED IN THIS
INSTALLATION
M965642 Rev. 1.5 (11/16)
Fig. 11
Unit #1
Unit #2
Unit #3
Already installed
1
TO FLUSH
VALVE SOLENOID
2
TO FLUSH
VALVE SOLENOID
TO FLUSH
VALVE SOLENOID
POWER SUPPLY
Unit #4
4
3
3a
4
(See AC version installation
instructions, page 7)
MAXIMUM OF 15 UNITS PER POWER SUPPLY.
10' MAXIMUM CABLE LENGTH BETWEEN UNITS.
9 MULTI-AC VERSION – DAISY-CHAIN; (PK00.MAC POWER KIT) Fig. 11
Important: Disconnect AC Power Supply from wall outlet before making daisy-chain connections.
Note: For Unit #1 installation instructions, refer to AC version section (page 8).
For subsequent Units...
1. Take the first 27" EXTENSION CABLE (1) and connect one end to the solenoid cable, the other
end to a sensor cable.
2. Take the second 27" EXTENSION CABLE (2) and connect one end to the available sensor
cable, the other end to one of the two terminals at the one end of the Y-ADAPTER (3).
3. Take the 10' EXTENSION (4) and connect one end to the single terminal of Y-ADAPTER (3), and
the other end to available terminal of the previous unit’s Y-ADAPTER (3a).
4. Repeat process for each subsequent unit.
5. Place Y-ADAPTERS (3) into respective electrical box.
6. Plug in AC power supply into wall outlet once all daisy-chain unit connections have been made.
CAUTION: Use only American Standard supplied transformers
and cable sets. Using non-AS supplied cables, or cutting,
splicing or modifying any components will void the warranty.
9
M965642 Rev. 1.5 (11/16)
10 CONNECT OVERRIDE HOSES,
Fig. 12
AC & DC POWER; Fig. 12
1. Push the BLACK HOSE (1) into the BOTTOM HOSE
CONNECTOR (2) on flush valve body and push the
other end into the back of the MANUAL OVERRIDE
VALVE (3).
3
2. Push the BLUE HOSE (4) into the TOP HOSE
CONNECTOR (15) on flush valve body and push the
other end into the BOTTOM CONNECTOR (6) of the
manual override valve.
1 BLACK
HOSE
5
6
4
BLUE
HOSE
2
-C-L-
10
M965642 Rev. 1.5 (11/16)
MAINTENANCE
Fig. 13
1
A INSTALL NEW BATTERY; Fig. 13
2
1. Remove the six COVER PLATE SCREWS (1), then
remove COVER PLATE (2). Fig. 13.
2. Remove old BATTERY (3) from BATTERY HOLDER (5).
Install the new BATTERY (4), making sure the terminal
side is inserted first and shape of the battery follows the
shape of the BATTERY HOLDER (5). Reinstall COVER
PLATE (2). Fig. 13a.
Fig. 13a
5
2
TERMINAL SIDE
-P2
CR
IMPORTANT: To avoid overflowing, the STOP VALVE (3)
must never be opened to the point where the flow from
the valve exceeds the flow capacity of the fixture. Valve
is designed to provide stated flush volume with a 25
GPM flow rate.
CR-P2
3
B ADJUST STOP VALVE; Fig. 14
4
Fig. 14
COUNTER-CLOCKWISE
OPENS STOP VALVE
4
1. After installation is complete, remove COVER PLATE
(1). Peel off the PROTECTIVE FILM (2) from the sensor.
Standing to one side, block the sensor with your hand for
10 seconds. Remove your hand and listen for audible
“click” from within the valve.
CLOCKWISE
CLOSES
STOP
VALVE
3
2. Turn on STOP VALVE (3) 1/4 turn to 1/2 turn (CCW) and
test for leaks.
Note: Unit may flush for approximately 5 to 10 seconds
when water is first turned on. If flow persists, turn water
off and repeat step #1 above.
1
3. Actuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds.
NOTE: Stand outside of sensor detection area.
B) Remove hand from detection area; unit will flush in
approximately 3 seconds.
2
5
4. Adjust STOP VALVE (3) after each flush until the stated
flush volume is achieved, no splashing occurs and the
fixture is properly cleansed.
5. Attach the COVER PLATE (1) to the WALL BOX (4) with
the six MOUNTING SCREWS (5). Use a 2.5mm Hex
Wrench supplied to secure COVER PLATE (1).
CARE INSTRUCTIONS:
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH
WITH A COARSE SURFACE.
11
M965642 Rev. 1.5 (11/16)
C SET DETECTION RANGE
(if required); Fig. 15 & 16
Fig. 15
Note: The detection distance is preset and ideal for most
installations. Should an adjustment be required, follow the
steps below.
1. Remove COVER PLATE (1). See Step A for removing front
panel instructions.
2
2. Disconnect SENSOR CABLE (2) from BATTERY HOLDER
(3) or from POWER SUPPLY 27" EXTENSION CABLE (4).
Fig. 15.
3
1
4
3. Keeping hands away from the sensor detection area,
reconnect the SENSOR CABLE (3) and quickly hang the
COVER PLATE (1) onto the wall box.Do not secure the
COVER PLATE (1) at this time. Fig. 15.
Note: You have 5 seconds to begin entering the program
code after power connection is made.
4. While the SENSOR CONTROL LED (5) is blinking slowly,
place your hand 1 to 2". (30-50 mm.) in front of the sensor.
Fig. 16.
5. When the LED (5) stops blinking and stays “ON”, move your
hand to the desired position from sensor and hold in place
until the LED (5) begins to blink again. Fig. 16.
Note: Detection Zone is 400mm - 800mm.
(Factory Setting: 400mm)
6. Once the SENSOR CONTROL LED (5) begins to blink
again, remove your hand from the detection zone. When
the flashing stops, the detection distance is set.
7. Replace and secure COVER PLATE (1). Fig. 16.
8. Actuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds.
Note: Stand outside of sensor detection area.
B) Remove hand from in front of the sensor; unit will flush
in approximately 3 seconds.
Fig. 16
5
5
1" - 2" (30 - 50 mm)
BLINKING
LED
BLINKING
LED
1
DETECTION ZONE
400 - 800 mm
(Factory Setting: 400 mm)
1
12
M965642 Rev. 1.5 (11/16)
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FUNCTION
IS ANGLE STOP OPEN?
NO
OPEN VALVE
YES
CRITICALLY LOW BATTERY . INSTALL
NEW BATTERY
YES
REPEATED DOUBLE
FLASH ON SENSOR?
NO
1
RECONNECT BATTERY TO SENSOR.
FLASH ON SENSOR FOR 5
SECONDS?
NO
1
NO
2
2
YES
PUSH MANUAL OVERRIDE
BUTTON; WILL THE UNIT FLUSH?
DEAD BATTERY. INSTALL NEW
BATTERY. REPEAT.
DAMAGED SENSOR WIRE. REPLACE
SENSOR. (ONLY IF ABSOLUTELY NEEDED)
DAMAGED SOLENOID. REPLACE
SOLENOID
YES
NO
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
REPLACE PISTON ASSEMBLY.
(844) CRT-TEAM / (844) 278-8326
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
UNIT WILL ONLY FLUSH MANUALLY
P rod uc t na m e s l i s t e d he re i n a re t r a d e m a r k s of A S A m e r i c a , I nc . ©201 6
CLOSE ANGLE STOP AND OPEN
AGAIN TO PRIME THE VALVE.
DOES FLUSHING STOP?
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
NO
PUSH MANUAL OVERRIDE
BUTTON. DOES IT RETURN TO ITS
ORIGINAL POSITION FREELY?
DAMAGED MANUAL OVERRIDE
BUTTON. REPLACE MANUAL
OVERRIDE BUTTON
NO
YES
1
RECONNECT BATTERY TO SENSOR.
FLASH ON SENSOR FOR 5
SECONDS?
2
NO
NO
1
DEAD BATTERY. INSTALL NEW
BATTERY. REPEAT.
2
DAMAGED SENSOR WIRES. REPLACE
SENSOR. (ONLY IF ABSOLUTELY NEEDED)
YES
REPLACE PISTON & SOLENOID
ASSEMBLY.
UNIT IS CONTINUOUSLY FLUSHING
REPEATED DOUBLE
FLASH ON SENSOR?
CRITICALLY LOW BATTERY. INSTALL
NEW BATTERY
YES
NO
RECONNECT BATTERY TO SENSOR.
FLASH ON SENSOR FOR 5
SECONDS?
1
2
NO
1
DEAD BATTERY. INSTALL NEW
BATTERY. REPEAT.
NO
2
DAMAGED SENSOR WIRES. REPLACE
SENSOR. (ONLY IF ABSOLUTELY NEEDED)
YES
REPLACE SOLENOID.
13
M965642 Rev. 1.5 (11/16)
SELECTRONIC®
CONCEALED TOILET FLUSH VALVE
1.1, 1.28 & 1.6 GPF
MODEL NUMBERS
606B.3XX
M964944-0020A
MANUAL VALVE
M950319-0071280A
SENSOR ASSEMBLY (1.28 gpf)
M950319-0071600A
SENSOR ASSEMBLY (1.6 gpf)
M950319-0071100A
PWRX Power Kit
PK00.WRK
SENSOR ASSEMBLY (1.1 gpf)
M962770-0071280A
M950361-0070A
PWRX BATTERY PACK
M950360-0070A
CONNECTOR
LOCKING
DEVICE
COVER WITH SEAL (1.28 gpf)
DOES NOT INCLUDE SENSOR
M962770-0071600A
COVER WITH SEAL (1.6 gpf)
DOES NOT INCLUDE SENSOR
M964455-0070A
BRACKET
M964941-0021100A
COVER WITH SEAL (1.1 gpf)
DOES NOT INCLUDE SENSOR
CR-P2 Battery Power Kit
PK00-CRP
A923654-0070A
A918792-0070A
BATTERY 6V CR-P2
COVER SCREWS
M950360-0070A
CONNECTOR
LOCKING DEVICE
M964963-0070A
SENSOR MOUNTING KIT
(LARGE PLATE)
M950514-0070A
BATTERY HOLDER
Plug-In AC
PK00.PAC
A906680-0070A
BONNET NUT
M964852-0070A
M964302-0070A
SOLENOID ASSEMBLY
M964551-0070A
PISTON ASSEMBLY
SOLENOID & PISTON
SUBASSEMBLY
M950338-0070A
POWER SUPPLY
M950360-0070A
CONNECTOR
LOCKING
DEVICE
M964945-0020A
ADJUSTABLE TAILPIECE
M962750-0070A
M962754-0070A
MANUAL VALVE
HOSE KIT
Hard-Wired AC
PK00.HAC
1" STOP VALVE KIT
M962926-0070A
M950399-0070A
SINGLE AC ADAPTER
M950511-0070A
10' EXTENSION
M950520-0070A
POWER SUPPLY
1" SWEAT ADAPTER
A912809-0070A
O-RING
M950360-0070A
CONNECTOR
LOCKING DEVICE
M950399-0070A
SINGLE AC
ADAPTER
M964402-0070A
VACUUM BREAKER KIT
M950218-0020A
M950217-0020A
VACUUM BREAKER FLUSH
CONNECTION KIT
(Exposed Back Spud)
VACUUM BREAKER FLUSH
CONNECTION KIT
(Concealed Back Spud)
(FOR MODEL 606X.2X1)
(FOR MODEL 606X.2X2)
Multi-AC
Power Kit
PK00.MAC
M950511-0070A
10' EXTENSION
M950512-0070A
MULTI-AC ADAPTER
M950216-0020A
M962996-0020A
WASHER AND
SUPPORT KIT
VACUUM BREAKER FLUSH
CONNECTION KIT
(Top Spud)
(FOR MODEL 606X.2X3)
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
Mon. – Fri. 8:00 a.m. to 8:00 p.m. EST Sat. 10:00 a.m. to 4:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names lis ted herein a re tra dema r ks of AS A mer ic a , I nc . © 2016
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
M965642 Rev. 1.5 (11/16)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising