Professional Weighing Equipment Weigh Bars

Professional Weighing Equipment Weigh Bars
Professional Weighing
Equipment
!
!
!
!
Weigh Bars
Dust and Waterproof Scale IP65
!
!
!
!1
!
Operating Manual
!
Declaration of Conformity
!
Declaration of conformity for apparatus with CE mark
!
We hereby declare that the product to which this declaration refers conforms to the following
standards.
Electronic scale: Weigh Bar series
Imperial version
Metric version
WB 5000
WB 2500k
WB 10000
WB 5000k
!
!
!
!
Mark applied
EU Directive
Standards
!2
!2004/108/EC
!EN 61326-1: 2006
!
!
!
!
Date: 14. 08. 2014
Signature:
!
!
Boon Lim, R & D Manager
LW Measurements LLC, 3510 Industrial Drive, Unit H Santa Rosa, CA 95403
!
Identification
!
!
Customer Service
!
USA
LW Measurements LLC, 3510 Industrial Drive,
Unit H Santa Rosa, CA 95403
USA
Tel: (707) 542-2185
FAX: (707) 542-3285
!
EUROPE
LW Measurements Europe Ltd Chalkwell Park House 700 London Road
Westcliff-on-Sea Essex SS0 9HQ
!3
United Kingdom
Tel: 01702-476700
Fax: 01702-477380
!
ASIA
LW Measurements PTY Ltd
Block 1004, Toa Payoh North
#03-16 Singapore 318995
Tel: (65) 6458 3438
HP: (65) 8119 3401
!
!
!
http://lwmeasurements.com
!
Refer to our website for information about local customer service centers and details of their
addresses.
!
!
!
!
Introduction
What you should know about these Operating Instructions:
!
Tree® Professional Weighing Equipment products are simple to operate.
!4
Nevertheless, you should read through these operating instructions in their entirety, so that you can make
optimum use of the full potential and the diverse possibilities of the weighing machine in your daily work.
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
These operating instructions contain guidance in the form of pictograms and keyboard diagrams, which
should help you in finding the required information:
For the labelling of potential hazards and advice, please see Section 1 Safety below.
!5
Contents
!
Section
Heading
1
Safety
!1.
Representation and symbols
2. Safety recommendations
3. IP 65 protection
2
Your weighing machine
!2.1
Construction and functions
2.1.1 Construction of the weighing machine
2.1.2 Functions of the weighing machine
!2.2
Application, conformity
2.2.1 Correct use of the weighing machine
2.2.2 Conformity
!2.3
Data and parameters
2.3.1 Technical data
2.3.2 RS232 Data Interface
3
Getting started with your weighing machine
!3.1 Unpacking the equipment
3.2
3.3
3.4
3.5
3.6
4
Scope of delivery
Assembling your weighing machine
Choice of a suitable location
Checking the mains voltage
Calibrating the weighing machine
Working with the application menu using the intelligent keypad
!6
!4.1
Display messages and key functions
4.1.1 Display messages
4.1.2 Key functions
!4.2
Program options
4.2.1 Interface setting
4.2.2 Function settings
!4.2.2.1 Setting auto shut-off
4.2.2.2 Setting backlight
4.2.2.3 Setting power on mode
!!
4.2.3 Working mode setting
!4.2.4 Hold function
!
5
Calibration using an external calibration weight
6
Maintenance and service
7
Transport and storage
!7.1 Transportation and shipping
7.2 Storage
!
!
!7
1 Safety
!
1.1 Representations and symbols
!
!
!
!!
Important instructions, which involve safety, are highlighted with the appropriate mark:
1.2 Safety recommendations
!
!
!
!
!
!
!
When using the weighing equipment in surroundings with increased safety requirements, the
corresponding regulations must be observed.
The weighing machine may only be used with the power adapter supplied exclusively for use with the
weighing machine.
Before inserting the power adapter, the user must ensure that the operating voltage stated on the power
adapter agrees with the mains voltage.
If not, please contact Customer Service at the address above.
If the power adapter or its cable is damaged, the weighing machine must immediately be disconnected
from the electricity supply (pull out the power adapter).
The weighing machine may only be operated from mains electricity supply with a power adapter which is
in perfect condition.
If there should be any reason to believe that it is no longer possible to operate the weighing machine
without danger, the weighing machine is to be immediately unplugged from the electricity supply (pull out
power adapter) and secured against inadvertent operation.
!
!
!
In carrying out maintenance work, it is essential to follow the recommendations in Chapter 6 Maintenance
and service.
The weighing machine must not be operated in an area subject to explosion risks.
Care must be taken when weighing liquids to ensure that no liquid is spilt into the inside of the weighing
machine or into connections on the rear of the equipment or the power adapter. If liquid is spilt on the
weighing machine, it must immediately be unplugged from the mains electricity supply (pull out power
adapter).
The weighing machine may only be operated again after it has first been re-checked by a service
technician.
!
!!
!!
!
These operating instructions must be read by each operator of the equipment and must be available at
the workplace at all times.
1.3 IP65 protection
!8
!
Your Weigh Bar weighing machine is rated to IP65.
The IP rating system
•
IP stands for Ingress Protection
•
The rating’s first digit e.g. IP65 relates to the ingress protection against dust (6 means dust tight,
see the table below)
•
The second digit e.g. IP65 relates to the ingress protection against water (5 means protected
against water jets, see the table below)
Protection against solid objects
1st Digit
Description
Definition
0
Non-protected
No special protection
1
Protected against solid objects greater
than 50 mm
A large surface of the body such as the hand (no protection against
deliberate access). Solid objects exceeding 50mm diameter
2
Protected against solid objects greater
than 12 mm
Fingers or other objects not exceeding 80 mm in length. Solid objects
exceeding 12 mm diameter
3
Protected against solid objects greater
than 2.5 mm
Tools, wires, etc of diameter or thickness greater than 2.5 mm. Solid
objects exceeding 2.5 mm diameter.
4
Protected against solid objects greater
than 1.0 mm
Wires or strips of thickness greater than 1.0 mm. Solid objects
exceeding 1.0 mm
5
Dust protected
Ingress of dust is not totally prevented but dust does not enter in
sufficient quantity to interfere with satisfactory operation of the
equipment
6
Dust-tight
No ingress of dust
Protection against liquids
2nd Digit
!!
!
Description
Definition
0
Non-protected
No special protection
1
Protected against dripping water
Dripping water (vertically falling drops)
2
Protected against dripping water when
tilted up to 15º
Vertically dripping water shall have no harmful effect when the
enclosure is tilted at any angle up to 15º from its normal position
3
Protected against spraying water
Water falling as spray at an angle up to 60º from the vertical shall have
no harmful effect
4
Protected against splashing water
Water splashed against the enclosure from any direction shall have no
harmful effect
5
Protected against water jets
Water projected from a nozzle against the enclosure from any direction
shall have no harmful effect
6
Protected against heavy seas
Water from heavy seas or water projected in powerful jets shall not
enter the enclosure in harmful quantities
7
Protected against the effects of immersion
Ingress of water in a harmful quantity shall not be possible when the
enclosure is immersed in water under defined conditions of pressure
and time
8
Protected against submersion
The equipment is suitable for continuous submersion in water under
conditions, which shall be specified by the manufacturer
!9
!
2 Your weighing machine
!
2.1 Construction and functions
!
2.1.1 Construction of the weighing machine
!
The weighing machine consists of the weighing bars (1), the indicator (2), the adapter (3) and this
operating manual.
!
!
!!
!!
!
!!
!!
!
!!
!!
!!
!!
!
!!
!!
!!
!!
!!
!!
!!
Figure 2.1 Your weighing machine
2
1
3
!10
2.1.2 Functions of the weighing machine
!
!
!
The Weigh Bars are high-quality electronic precision weighing machines with the following specifications
Imperial weight unit version
Model number
Capacity
Graduation
Weighing Platform Size
WB 5000
5000 lb
1 lb
40 x 3.9 inches / 102 x 9.9 cm
WB 10000
10000 lb
2 lb
40 x 3.9 inches / 102 x 9.9 cm
WB 5000: 56 lb / 63 lb ( 25.4 kg / 29 kg)
Net/gross weight
WB 10000: 65 lb / 71 lb ( 30 kg / 33 kg)
Package
125 x 49.5 x 13(cm
(Standard carton)
Operating Temp.
0-40℃ (32-104℉)
Power source
6 x AA Dry cells (not included) or Adapter 12V DC / 150mA
!
!
Metric weight unit version
Model number
Capacity
Graduation
Weighing Platform Size
WB 2500k
2500kg
0.5kg
40 x 3.9 inches / 102 x 9.9 cm
WB 5000k
5000kg
1kg
40 x 3.9 inches / 102 x 9.9 cm
Net/gross weight
WB 2500k: 56 lb / 63 lb ( 25.4 kg / 29 kg)
WB 5000k: 65 lb / 71 lb ( 30 kg / 33 kg)
Package
(Standard carton)
Operating Temp.
125 x 49.5 x 13(cm
0-40℃ (32-104℉)
!11
!
Power source
6 x AA Dry cells ( not included) or Adapter:12V DC / 150 mA
!!
!
FEATURES
−
−
−
−
−
−
−
−
−
Selectable auto backlight
Selectable auto shut-off
Hold function
ZERO range ( 0% - 4% of full capacity)
TARE range ( 4% - 100% of full capacity)
Animal weighing mode
AnyCal calibration software
Selectable calibration units: kg or lb
RS232
!!
!
2.2 Application, conformity
!
2.2.1 Correct use of the weighing machine
!
!
The maximum allowable load of the weighing machine must never be exceeded, otherwise the weighing
machine may be damaged.
In using the weighing machine in combination with other appliances as well as with appliances produced
by other manufacturers, the appropriate regulations for the safe use of the relevant attachments and their
application in accordance with instructions must be observed.
!!
2.2.2 Conformity
!
!
!!
!
2.3 Data and parameters
!
2.3.1 Technical data
!
!
!
The weighing machine has been manufactured and tested in accordance with the standards and
recommendations set out in the declaration of conformity.
The power adapter produced for the operation of the weighing machine and intended exclusively for this
application, complies with the appropriate electrical protection class.
The following applies to Weigh Bar series
Power supply:
. Input: 110 or 230V AC (+/-15-20%); 50 to 60Hz
!12
. Output: 12V DC 150mA
!
!
!
!!
Allowable ambient conditions
Temperature: 5°C - 40°C
Relative humidity: 25% - 85%, non-condensing
If you have any questions on the technical data or require detailed technical information on your balance,
please contact your technical representative.
2.3.2 RS232 Data interface
!
!!
!
1.
!
Connector: DB9
2.
Transmissions Settings
!
3.
SCALE
2
3
5
Mode: Simplex Asynchronous Serial
Data Bit: 8
Stop Bit: 1
Baud Rate: 9600
Parity Bit: None
Data Format: ASCII
Transmission Information Format: 20 Byte ,blank=20H
! !
W:
P:
DATA:
UNIT:
!
PC
2
3
5
CR:
LF:
1~2
3
4~13
14~18
19
20
‘W: ’
P
DATA
UNIT
CR
LF
Start of Data Transmission=57H+3AH
Polarity ‘+’ = 2BH = Positive
‘-’ = 2DH =Negative
‘ 12.345’= 20H+20H+20H+20H+31H+32H+2EH+33H+34H+35H
‘lb’
=6CH+62H+20H+20H+20H
‘kg’
=6BH+67H+20H+20H+20H
= 0DH
= 0AH
!13
3 Getting started with your weighing machine
!
3.1 Unpacking the equipment
!
!
The machine is delivered in an environmentally-friendly carton, specifically developed for this precision
instrument, which provides optimum protection for the balance during transportation.
We suggest that you retain the original packaging in order to avoid transportation damage if re-shipping or
transporting the balance and to allow the unit to be stored in the best conditions if it is out of operation for
an extended period.
!
!
!
In order to avoid damage, attention must be given to the following points when unpacking the balance:
Unpack the weighing machine carefully. It is a precision instrument.
When outside temperatures are very low, the balance should first be stored for some hours in the
unopened transport package in a dry room at normal temperature, so that no condensation settles on the
unit when unpacking.
!
!
!
Check the weighing machine immediately after unpacking for externally visible damage. If you should find
transport damage, please inform your service representative immediately.
If the unit is not to be used immediately after purchase but only at a later time, it should be stored in a dry
place where fluctuations in temperature are as small as possible (see Chapter 7 .Transport, storage.).
Read through these operating instructions, even if you already have prior experience with weighing
equipment, before you work with the unit and pay attention to the Safety recommendations (see Chapter
1 .Safety).
!!
3.2 Scope of delivery
!
!
!
Inspect delivery for completeness immediately on unpacking all components.
Checklist for complete delivery
Component delivered present yes / no
Weighing Bars (2pcs)
Indicator
Power adapter
!!
!!
!!
!
Operating manual
3.3 Assembling your weighing machine
!14
!
!
!!
The weighing machine is delivered in partly dismantled condition. Assemble the individual components in
the following sequence:
−
−
Place the unit holder in position.
Insert the power adapter cable plug into the socket at the rear of the balance.
3.4 Choice of a suitable location
!
The environment in which your weighing machine is used is very important. Air movement, temperature
changes, vibrations, direct sunlight, etc. all influence the performance of high precision weighing
machines. Therefore, place your weighing machine on a solid, sturdy surface that is free of air currents,
vibration and not in direct sunlight. The surface should not be magnetic and should be located away from
doors, windows, heaters, air conditioners and fans.
!
!
To summarize:
!
−
Put the weighing machine on a solid, firm and preferably vibration-proof, horizontal base
−
Make sure that the weighing machine cannot be shaken or knocked over
−
Protect from direct solar radiation
−
Avoid drafts and excessive temperature fluctuations
!
3.5 Checking the mains voltage
!
!
!
!
!
!
!
The following Safety recommendations must be observed when connecting the balance to the mains:
The balance may only be operated with the power adapter supplied.
Check before connecting the power adapter to the mains supply, that the operating voltage stated on the
power adapter agrees with the local mains voltage.
If the operating voltage is not the same as the mains voltage, the power adapter must on no account be
connected to the mains supply. Contact customer service.
IMPORTANT NOTE: DO NOT TURN THE INDICATOR ON UNTIL ALL CONNECTIONS ARE MADE. IF
THE INDICATOR IS ON PRIOR TO MAKING CONNECTIONS, AND THE CONNECTIONS ARE MADE,
DAMAGE MAY OCCUR.
!
!!
Please complete the following steps before using the scale:
!15
!!
!!
!!
Step1: Connect the cable to the load cell and plug the metal connectors under power off condition.
!
!
!
!
!
Step 2: Adjust the four scale feet horizontally.
!
!
!
!
!
!
!
!
!
!
!
!
3.6 Calibrating the weighing machine
!
Since the Earth’s gravity is not the same everywhere, each balance must be adjusted to compensate for
the gravity differences at each location in accordance with the underlying physical weighing principles.
This adjustment process, known as calibration and must be carried out on initial installation and after
each subsequent relocation.
!16
!
In order to ensure exact measurements, it is recommended that the balance should be calibrated
regularly using a known external calibration weight (see Section 5 below).
!17
4 Working with the application menu using the Intelligent
Key-Pad
!
!
!
!
!
4.1 Display messages and key functions
!
4.1.1 Display messages:
!
!
!Low battery indicator
Negative value indicator
Zero indicator
!!
!!
!
4.1.2 Key Functions:
!
!
!
!
!
!!
!
1.
The ON/OFF key is to turn the Scale On or Off
2.
The HOLD key is to store the weight value.
3.
The UNIT key is to toggle different weighing units.
4.
The ZERO key: Zero feature if load weight below 4% of full capacity; Tare feature if load weight
between 4% to 100% of capacity.
5.
The PRINT key is to send data to external device through RS232 connector.
!18
4.2 Program options
!
Please see our web-site at http://lwmeasurements.com for practical demonstrations of application
usage.
!
4.2.1 Interface Settings
!
−
Press and hold HOLD key, and then press ON/OFF key to turn on the scale, display will show AON or A-OFF
−
Press UNIT key, display will show “L-ON” or “L-OFF”
−
Press UNIT key again, display will show “P-XX”
!
!
!
−
Press ZERO key to select CON,OFF, KEY, STB
!
a)
OFF stands for serial data output disabled
b)
KEY stands for manual mode by pressing [PRINT]
c)
STB stands for automatic print when scale is stable
d)
CON stands for continuous print
−
!
Press ON/OFF key to turn off the Scale.
!
4.2.2 Function settings
!
!
!
!
4.2.2.1 Setting Auto Shut off
Press and hold HOLD key, then press ON/OFF key to turn on the Scale, display will show “A ON” or “A
OFF”, Press ZERO key to select Auto shut off mode “ON” or “OFF”.
4.2.2.2 Setting Backlight
Press and hold HOLD key, then press ON/OFF key to turn on the Scale, display will show “A ON” or “A
OFF”, Press UNIT key, display will show “L ON”, “L OFF” or “L AU”, press ZERO key to select back light
On, Off or Au(auto)
!19
!
!
4.2.2.3 Setting power-on mode
Press and hold HOLD key, then press ON/OFF key to turn on the Scale, display will show “A ON” or “A
OFF”, Press UNIT key three times, display will show “J ON” or “J OFF”, press ZERO key to select “J
ON” (means showing zero when scale is turned on) or “J OFF” (means showing the weight placed when
the scale is turned on).
!
!
!
!
4.2.3 Working mode settings
!!
- Press & hold UNIT and HOLD keys, then press ON/OFF key to turn on the scale
!
- The display will show Ani. Su, press UNIT key to enter, press ZERO key to select ON (means animal
weighing mode) or OFF (means normal weighing mode), press HOLD key to confirm.
!
- Press HOLD key again, display will show Ani. Kd, press UNIT key to enter, press ZERO key to select
anti-shock range between 50, 100, 200 and 400, press HOLD key to confirm.
*** This is the anti-shock range 50d, 100d, 200d or 400d. The smaller division range is suitable for smaller
animals, the larger division range for larger animals
!
- Press HOLD key again, display will show Ani. Fd, press UNIT key to enter, press ZERO key to select
filter range between 0.5, 3, 5 and 10, press HOLD key to confirm.
*** This is the filter range, 0.5d, 3d, 5d or 10d that the scale displays, for example, if we use LVS 700lb x
0.2lb for weighing a 300lb cow, if we set it to be 0.5d, then the scale will show 299.8lb, 300lb, 300.2lb..., if
we set it to be 3d, then the scale will show 299.4lb, 300lb, 300.6lb... 0.5d can get much accurate
weighing, but it won’t be as stable; 10d will not obtain such an accurate weighing result, but it will be
much more stable.
!
- Press HOLD key again, the display will show Ani. Ft, press UNIT key to enter, press ZERO key to select
filter time between 1, 2, 3 and 4, press HOLD key to confirm.
*** This is the filter time, 1s, 2s, 3s or 4s that will take to display the weighing. Weighing will be more
accurate if the user chooses 4 second (longer displaying time), but not so accurate if 1 second (faster
displaying time) is chosen.
!
!!
!
4.2.4 Hold function
!!
!
will show
!- Remove the item from the platform, the readings .will“ indicator
still remain on the display
!
Press ON/OFF key to turn the scale off.
- Press ON/OFF key to turn on the scale, place the item on the platform.
- Wait for the readings stable, press HOLD key, the “
!20
- Press HOLD key to quit hold function mode
!21
!
5 Calibration - Using an External Calibration Weight
Calibration is generally required when the weighing machine is initially installed or if the weighing
machine is moved to a substantial distance from the original location. 30 minutes of warming up of the
scale is always needed before initial calibration.
A reminder when operating our larger capacity scales:
!
The WB series are calibrated at the factory. Usually no recalibration is necessary unless major
inaccuracies are observed. If calibration is deemed necessary, an appropriate test weight of at
least 2/3 of the full capacity of the scale should be used to obtain accurate weighing.
Calibration procedure:
!
!
!
!
!
!
!
−
Press and hold ZERO key and then press ON/OFF key to turn on the scale, the display will show
CAPu=
−
Press HOLD key, display will show CAP, press HOLD key again, display shows CALu=, press
UNIT key to select calibration unit KG or LB, a triangle icon will display to indicate KG or LB,
press HOLD key to confirm, it will show CALu= again.
−
Press HOLD key again, the display will show CAL, press UNIT key to set calibration weight,
display will show XXXXX with a flashing digit, press UNIT key to move the flashing digit to right,
press ZERO key to increase the value of the flashing digit, press HOLD key to confirm, it will
show CAL again. (We recommend a calibration weight at least 2/3 of the full capacity to get an
accurate weighing)
−
Press PRINT key, display will show CAL and then the AD value, press UNIT key when the stable
indicator displayed, it will show the flashing calibration weight,
−
Place the known test weight on the platform, press UNIT key after stable indicator displayed, it
will show ------, and then the AD value, now the calibration is finished.
−
Turn off the scale, remove the test weight from the platform.
−
Press ON/OFF key to turn the scale on to test if the weighing is accurate, if not, repeat above
steps.
!22
6 Maintenance and service
!!
The weighing machine must be treated carefully and cleaned regularly. It is a precision instrument.
!
!
!
For maintenance-work, the balance must be separated from the power supply (remove power adapter
plug from socket). Also ensure that the balance cannot be reconnected to the power supply during the
work by a third party.
!
!
!
See Section 1.3 above regarding IP65. The scale may be washed down.
!
!
Never use solvents, acids, alkalis, paint thinners, scouring powders or other aggressive or corrosive
chemicals for cleaning, since these substances attack the surfaces of the scale housing and
can cause damage.
!!
!23
7 Transport, storage
!
7.1 Transportation and shipping of the weighing machine
!
Your weighing machine is a precision instrument. Treat it carefully. Avoid shaking, severe impacts and
vibration during the transportation.
!
!!
Take care that there are no marked temperature fluctuations during the transportation and that the
weighing machine does not become damp (condensation).
7.2 Storage of the weighing machine
!
If you would like to take the weighing machine out of service for an extended period, disconnect it from
the electricity supply, clean it thoroughly (see Section 6 .Maintenance and servicing.) and store it in a
place which meets the following conditions:
!
!
!
!
!
−
No violent shaking, no vibrations
−
Minimum temperature fluctuations
−
No direct solar radiation
−
Minimum moisture
The weighing machine should preferably be dispatched and transported in the original packaging to avoid
transportation damage.
!
The weighing machine should preferably be stored in the original packaging, since this provides optimal
protection for the weighing machine.