MAVERICK ™
high frequency
opportunity
CHARGER
MAVERICK ™
high frequency
fast charger
MAVERICK ™
high frequency
Multi-pro™
More energy efficient than
low frequency opportunity
chargers, with a .95 full load
power factor. Delivers a reduced
battery recharge temperature,
due to low ripple current.
More energy efficient than low
frequency opportunity chargers,
with a .95 full load power factor.
Delivers a reduced battery
recharge temperature, due to
low ripple current.
The Maverick Multi-Pro
(Multi-Amp, Multi Volt) has
a high power factor and is
the most efficient charger
available, resulting in the
lowest operating cost
Features & Benefits
Features & Benefits
Features & Benefits
No battery modifications are required
Includes the TCC 2.0 Controller:
>Delayed start from fifteen minutes to four hours in fifteen minute intervals
>Equalize can be done manually, automatically with day/time setting, or every five cycles
>Automatic refresh charge every 24 hrs
>Programmable charge block out time
(peak demand electrical cost control)
>Programmable charge termination when battery voltage reaches the gassing point, to prevent excessive gassing
>Remote Control Interface for use when mounted above arms reach
>Auto start with five second delay
>Selectable start rate of 18 or 25 Amp per 100 Amp Hour
Cool down time displayed
Manual jump start for over-discharged batteries
Automatic Shutdown for the following:
>80% or final charge exceeds time limit
>Volts per cell outside safe limits
>Charging current too high or too low
>Maximum battery temperature
exceeded with optional sensor
>Charger internal temperature outside
of specification
LED Charge Status Indicators:
>Gas gauge > Charge complete
>Charging > Fault shutdown
>80% charged > Equalize
Digital readout displays:
>Time remaining to 80% & full charge
>Charge current/voltage
>Equalize in process
>Fault codes
>Charge data 25 cycles
(time, AH returned, and voltage)
>Charger setup
No battery modifications are required
Includes the TCC 2.0 Controller:
>Delayed start from fifteen minutes to four hours in fifteen minute intervals
>Equalize can be done manually, automatically with day/time setting, or every five cycles
>Automatic refresh charge every 24 hrs
>Programmable charge block out time
(peak demand electrical cost control)
>Programmable charge termination when battery voltage reaches the gassing point, to prevent excessive gassing
>Remote Control Interface for use when mounted above arms reach
>Auto start with five second delay
>Start rate of 31-40 amp per 100 amp hour, rate application dependent
Cool down time displayed
Manual jump start for over-discharged batteries
Automatic Shutdown for the following:
>80% or final charge exceeds time limit
>Volts per cell outside safe limits
>Charging current too high or too low
>Maximum battery temperature exceeded with optional sensor
>Charger internal temperature outside
of specification
Digital Readout Display:
>Time remaining to 80% and full charge
>Charge current/voltage
>Equalize in process
>Fault codes
>Charge data twenty five cycles
(time, AH returned and voltage)
LED charge status indicators:
>Gas gauge > Charge complete
>Charging > Fault shutdown
>80% charged > Equalize
Includes the TCC 2.0 Controller:
>Delayed start from fifteen minutes to
four hrs in fifteen minute intervals
>Equalize can be done manually, automatically with day/time setting, or every five cycles
>Automatic refresh charge every 24 hrs.
>Programmable charge block out time
(peak demand electrical cost control)
>Remote Control Interface for use when mounted above arms reach
>Auto start with five second delay
>Selectable start rate of 18 or 25 Amp
per 100 Amp Hour
>Cool down time displayed
>Programmable voltage & amp hr. capability
Quickly determines battery voltage without
any peripheral devices (AES proprietary
battery integration algorithm)
Automatic Shutdown for the following:
>80% or final charge exceeds time limit
>Volts per cell outside safe limits
>Charging current too high or too low
>Maximum battery temperature exceeded with optional sensor
>Charger internal temperature outside
of specification
LED charge status indicators:
>Gas gauge > Charge complete
>Charging > Fault shutdown
>80% charged > Equalize
Digital readout displays:
>Time remaining to 80% charge
>Charge current/voltage
>Equalize in process
>Fault codes
>Charge data 25 cycles
(time, AH returned, and voltage)
>Charger setup
MAVERICK ™
high frequency
CONVENTIONAL
CHARGER
PALOMINO™
ECONOMY charger
QUARTERHORSE™
opportunity
ChargER
The Maverick High Frequency
Conventional Charger, using
Insulated Gate Bipolar
Transistors (IGBT), returns more
energy at a lower cost than low
frequency conventional chargers.
The perfect combination of
performance and economy.
The ideal solution for users
to convert to opportunity
charging with the safest
and most effective method,
eliminating battery handling.
Features & Benefits
Features & Benefits
Features & Benefits
Delayed start from fifteen minutes to two
hours in fifteen minute intervals
Automatic refresh charge every 24 hours
Highest acceptable return rates without
battery modifications
Equalize can be done manually or every
five cycles
Automatic refresh charge every 12 hours
Remote Control Interface for use when
mounted above arms reach
Auto start with five second delay
Automatic Shutdown for the following:
>80% or final charge exceeds time limit
>Volts per cell outside safe limits
>Charging current too low
>Charger internal temperature outside
of specification
Digital Readout Display:
>Charge current/voltage
>Equalize in process
>Fault codes
LED Charge Status Indicators:
>Charging
> Equalize
>80% charged
> Fault shutdown
>Charge complete
Charge time of eight hours or less on a
normally discharged battery
Auto start with five second delay
Battery protection with override timers, wrong
battery sensing and negative charge slope
termination
Automatic shutdown for the following
conditions:
>80% charge does not occur in nine hours
>Final charge is not reached in six hours after 80% (gassing point)
>Volts per cell are too high or too low
>Charging current is too low
>Battery cable is disconnected
while charging
Three position digital display for showing:
>Charge current
>Fault diagnosis
LED Charge Status Indicators:
>Charging
>80% charged
>Charge complete
>Equalize
Red push button for manual shutdown
Manual jump start for over-discharged
batteries
Manual and or automatic equalization
Ten foot long output cables for added
flexibility
Numerous output connectors available
as standard
Easy access for programming all features
Low electrical noise superior in applications
with other electrical equipment and
controls
Remote control interface
Auto start with five second delay
Automatic shutdown for the following
conditions:
>80% or final charge exceeds time limit
>Volts per cell outside safe limits
>Charging current too high or too low
>Maximum battery temperature exceeded
Controlled Ferroresonant technology for
total charge control over the complete
charging cycle
Digital readout displays:
>Time remaining to 80% & full charge
>Charge current/voltage
>Equalize in process
>Fault codes
>Charge data 25 cycles
(time, AH returned, and voltage)
>Charger setup
LED charge status indicators:
>Gas gauge > Charge complete
>Charging > Fault shutdown
>80% charged > Equalize
Cool down time displayed
Manual jump start for
over-discharged batteries
STEED™
COLD STORAGE
CHARGER
Warhorse ™
multi circuit
ChargER
StableMate ™
Constant Current
Charger
Superior controlled output.
Cold storage tough. Capable of
recharging fully-depleted VRLA,
AGM, and flooded batteries in
eight hours or less.
Compact multi-circuit charger
fits more than one charger in a
single cabinet to cut down on
space requirements.
Advanced multi-cell constant
current charger excels in
battery shop, rental and
loaner-type installations.
Features & Benefits
Features & Benefits
Features & Benefits
Fully integrated and selectable microprocessor
control for automatic termination depending
upon the required profile specific to your
battery needs for flooded and VRLA
Interface jack for remote control & monitoring opts
Automatic refresh charge every twelve hrs.
Auto start with five second delay
Selectable delayed start from one to nine
hours, in one hour increments
Battery protection with override timers, wrong
battery sensing & negative charge slope termination
Automatic shutdown for the following:
>80% charge does not occur in nine hours
>Final charge is not reached six hours
after 80% (gassing point)
>Volts per cell are too high or too low
>Charging current is too low
>Battery cable is disconnected while charging
Advanced ferroresonant technology for total
charge control over the complete charging
cycle, for both flooded and VRLA batteries
Four selectable charge profiles
Four position digital display for showing:
>Charge current > Equalize in process
>Fault diagnostics
LED indicators showing charge status:
>Charging
> Equalize
>80% charged
> Fault shutdown
>Charge complete
LED test button
Charge data monitor button provides AH
returned, total charge time, avg. volts per cell
Cool down timer initiates at the end of charge
Red push button for manual shutdown
Manual jump start for over-discharged batteries
Manual and or automatic equalization
10ft long output cables for added flexibility
Numerous output connectors available as
standard
Fully integrated microprocessor control for
automatic dv/dt di/dt termination
Fully integrated microprocessor control for
dv/dt or elapsed time termination (Elapsed
time selectable for 8, 12, 18, or 24 hours)
Available in popular ratings incorporating from
two to six circuits in a common cabinet
Interface jack for remote control and
monitoring options
Automatic refresh charge every twelve hrs
Charge time of eight hours or less on a 100%
discharged battery
Auto start with five second delay
Selectable delayed start from one to nine hrs
Battery protection with override timers, wrong
battery sensing & negative charge slope termination
Automatic shutdown for the following:
>80% charge does not occur in nine hrs
>Final charge is not reached in six hrs after 80% (gassing point)
>Volts per cell are too high or too low
>Charging current is too low
>Battery cable is disconnected
while charging
Ferroresonant tapered charge for optimum
battery and charger life
Selectable 80% voltage of 2.37 or 2.45 volts
per cell
Four position digital display for showing:
>Charge current
> Equalize in process
>Fault diagnostics
LED indicators showing charge status:
>Charging
> Equalize
>80% charged
> Fault shutdown
>Charge complete
Red push button for manual shutdown
Manual jump start for over-discharged batteries
Manual and or automatic equalization
10ft long output cables for added flexibility
Multiple output connectors available as
standard
Charge over-discharged and sulfated
batteries
Auto start with five second delay
Automatic shutdown for the following:
> Maximum or minimum cells
are too high or too low
> Charging current is too low
> Battery cable is disconnected
while charging
> Elapsed time timer expired
Ferroresonant constant current charge
available in 25 amp or 50 amp output
models
Multi color LED’s indicating charging status,
and fault shutdown
Red push button for manual shutdown
Manual elapsed timer button
Supplied with seven foot AC line cord with
20 amp connector (Hard wired on HV
models only)
Eight foot long output cables with dual
connectors (SB175 and SB350)
Workhorse ™
series I
Workhorse II ™
series II
Workhorse ™
series III
Workhorse Series I, the most
rugged, single-shift capacity
charger where consistency,
reliability and efficiency
are key factors without the
pressure of recharge time.
Workhorse Series I I, horsepower
for the long haul. Dependable,
heavy duty industrial charger,
features ferroresonant
technology for single, dual
and multi-shift applications.
Workhorse Series I I I, the most
technologically advanced and
dependable heavy-duty charger
for multi-shift applications
requiring a full battery recharge
in less than eight hours.
Features & Benefits
Features & Benefits
Features & Benefits
Fully integrated microprocessor control for
automatic volt/time termination
Fully integrated microprocessor control for
automatic dv/dt - di/dt termination
Interface jack for remote control and
monitoring options
Automatic refresh charge every twelve hours
Charge time of eight hours or less on a
normally discharged battery
Auto start with five second delay
Selectable delayed start from one to nine hours
Battery protection with override timers,
wrong battery sensing and negative
charge slope termination
Automatic shutdown for the following:
>80% charge does not occur in nine hrs.
>Final charge is not reached six hours after 80% (gassing point)
>Volts per cell are too high or too low
>Charging current is too low
>Battery cable is disconnected
while charging
Ferroresonant tapered charge for optimum
battery and charger life
Selectable 80% voltage of 2.37 or 2.45 volts per cell
Four position digital display for showing:
>Charge current
>Equalize in process
>Fault diagnostics
LED indicators showing charge status
including:
>Charge complete > Charging >Fault shutdown
> 80% charged Red push button for manual shutdown
Manual jump start for over-discharged batteries
Manual and or automatic equalization
10ft. long output cables for added flexibility
Numerous output connectors available as
standard
No brackets needed for stacking
Fully integrated microprocessor control for
automatic dv/dt - di/dt termination
Interface jack for remote control and
monitoring options
Automatic refresh charge every twelve hours
Charge time of eight hours or less on a fully
discharged battery
Auto start with five second delay
Selectable delayed start from one to nine hrs
Battery protection with override timers, wrong
battery sensing & negative charge slope termination
Selectable refresh charge for 30 minutes every
24 hours
Ten to sixteen hours charge time.
Auto start with five second delay
Selectable one hour time delay
Memory retention during AC power loss
Automatic shutdown for the following:
>80% charge does not occur in twelve hrs.
>Volts per cell are too high or too low
>Charging current is too low
>Battery cable is disconnected
while charging
Ferroresonant tapered charge for optimum
battery and charger life
Selectable 80% voltage of 2.37 or
2.45 volts per cell
Digital display for showing:
>Charge current
>Fault codes
Multi color LED‚ indicating: charging status,
equalization mode and fault shutdown
Red push button for manual shutdown
Manual jump start for over-discharged
batteries
Manual equalize button.
Supplied with seven foot AC line cord and plug
(line cord not provided on 12A750, 18A450,
18A600, 18A750, 24A600 @120V AC)
10ft. long output cables for added flexibility
Numerous output connectors available as
standard
Automatic shutdown for the following:
>80% charge does not occur in nine hours
>Final charge is not reached six hours after 80% (gassing point)
>Volts per cell are too high or too low
>Charging current is too low
>Battery cable is disconnected
while charging
Ferroresonant tapered charge for
optimum battery and charger life
Selectable 80% voltage of 2.37 or
2.45 volts per cell
Four position digital display for showing;
>Charge current
>Equalize in process
>Fault diagnostics
LED test button
Charger data monitor button
>Provides AH returned
>Total charge time
>Average volts per cell
Cool down timer initiates at the end of charge
Red push button for manual shutdown
Manual jump start for over-discharged batteries
Manual and or automatic equalization
10ft. long output cables for added flexibility
Numerous output connectors available as
standard
Colt ™
SCR Cell
th e powe r of exce lle nce
Advanced fully integrated SCR
microprocessor control with four
selectable onboard charging
profiles. Automatically refreshes
its charge in the flooded profile
for 30 minutes every 24 hours.
Features & Benefits
Fully integrated SCR microprocessor control
with four selectable onboard charging profiles
Automatic refresh charge in the selectable
flooded profile for 30 minutes every 24 hours
Auto start with five second delay
Automatic shutdown for the following:
>80% charge does not occur
within sixteen hours
>Volts per cell are too high or too low
>Charging current is too low
>Battery cable is disconnected
while charging
Selectable 80% voltage settings based on
chosen profile
Digital display for showing;
> Charge current
>Fault codes
Multi color LED’s indicating:
>Charging status
>Equalization mode
>Fault shutdown
Red push button for manual shutdown
Manual equalize button
Splash resistant top surface
Supplied with detachable 120 volt line cord
If you would like more information
about any of our products please see
our website to download a product
brochure at:
www.AppliedEnergySol.com
Thank you for reading about our
family of Made in the U.S.A products
See for yourself what we mean when
we say the power of excellence!
Applied Energy SOlutions
Corporate offices
One Technology Place
Caledonia, New York 14423
Tel: 585-538-4421
800-836-2132
Fax: 585-538-6345
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising