SL STRIP 10IP (ENG).cdr

SL STRIP 10IP (ENG).cdr
SL STRIP 10IP
LED LUMINAIRE
www.philips.com/showline
Document Number: SL STRIP 10IP LED Luminaires User Manual
Version as of : 17th Sep 2015
SL STRIP 10IP User’s Manual
2015
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
IMPORTANT INFORMATION
Warnings and Notices
When using electrical equipment, basic safety precautions should always be followed including the following:
a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
b. Do not mount near gas or electric heaters.
c. Equipment should be mounted in locations and at heights where it will not readily be subjected to
tampering by unauthorized personnel.
d. The use of accessory equipment not recommended by the manufacturer may cause an unsafe
condition.
e. Do not use this equipment for other than intended use.
f. Refer service to qualified personnel.
SAVE THESE INSTRUCTIONS.
WARNING: You must have access to a main circuit breaker or other power disconnect device before
installing any wiring. Be sure that power is disconnected by removing fuses or turning the main circuit
breaker off before installation. Installing the device with power on may expose you to dangerous
voltages and damage the device. A qualified electrician must perform this installation.
WARNING: Refer to national Electrical Code and local codes for cable specifications. Failure to use
proper cable can result in damage to equipment or danger to personnel.
WARNING: T his equipment is intended for installation in accordance with the National Electric Code
and local regulations. It is also intended for installation in indoor applications only. Before any
electrical work is performed, disconnect power at the circuit breaker or remove the fuse to avoid
shock or damage to the control. It is recommended that a qualified electrician perform this installation.
Additional Resources for DMX512
For more information on installing DMX512 control systems, the following publication is available for purchase
from the United States Institute for Theatre Technology (USITT), "Recommended Practice for DMX512: A Guide
for Users and Installers, 2nd edition" (ISBN: 9780955703522). USITT Contact Information:
USITT
315 South Crouse Avenue, Suite 200
Syracuse, NY 13210-1844
Phone: 1.800.938.7488 or 1.315.463.6463
www.usitt.org
Showline Limited Two-Year Warranty
Showline offers a two-year limited warranty of its luminaires against defects in materials or workmanship from the
date of delivery. A copy of Showline two-year limited warranty containing specific terms and conditions can be
obtained by contacting your local Showline office.
IMPORTANT INFORMATION
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
About this Manual
The document provides installation and operation instructions for the following product:
SL STRIP 10 IP LED LUMINAIRE
Please read all instructions before installing or using this product. Retain this manual for future reference.
Additional product information and descriptions may be found on the product specification sheet.
Note: The SL STRIP 10 IP LED Luminaire is universal voltage 100 to 240 VAC (auto-ranging).
Included Items
SL STRIP 10IP LED Luminaire
QuickStart Guide
Diffuser Lens Kit*
*Note: Diffusers with 3 different beam
angles for options: 15 degree, 25 degree
and 11x38 degree
North American Market
International Market
AC Input cable (1750mm)
(For US, Canada and Latin America market only)
AC Input cable (1500mm)
(For International market only)
OR
AC Output cable (1000mm)
(For US, Canada and Latin America market only)
DMX Input cable (1000mm)
DMX Output cable (1000mm)
AC Output cable (1000mm)
(For International market only)
DMX Input cable (1000mm)
DMX Output cable (1000mm)
GENERAL INFORMATION
1
SL
Luminaires
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
MAIN FEATURES
01 pixel, 02 pixel, 05 pixel,10 pixel DMX Channel selection
10 built-in chase programs
0-255 dimming level
Standard DMX-512 and RDM protocol
01 Thru 99 Chase Speed adjustment
Power failure memory
LED display window-shows current activity and function state
INSTALLATION
SL STRIP 10IP LED Luminaires are provided with Trunnion Arms. The user can tighten the wing screws manually. For
hanging applications it is recommended (and may be required by local and national safety codes) to use and install a safety
cable (sold separately). When hanging the fixture, be sure to leave enough space around the luminaire to allow proper,
uninterrupted air flow.
Trunnion Arm
(x2)
Wing screw(x2)
Hanging Application
Trunnion Arm (x2)
Safety Cable Anchor Point
2
MAIN FEATURES
SAFETY CABLE: Is sold
separately and recommended for
all hanging installations and may
be required by national and local
codes. Use the provided safety
cable anchor points to attach the
safety cable for this luminaire.
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
Power Requirements
The SL STRIP 10IP LED Luminaire operates on AC input voltages from 100 to 240 VAC.
WARNING: This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit
when not in use.
AC Power Operation
When connected to an AC source, the unit operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains an auto-ranging power supply.
Each luminaire can draw up to 150 Watts.
WARNING:The maximum amount of units that may be daisy-chained is (A) 6 units 100VAC (10 Amps) or (B) 16 units 240VAC (10 Amps) for
Europe Standard. Refer to Table1-1for detailed information at various voltages.
WARNING: The maximum amount of units that may be daisy-chained is (A) 6 units 100VAC (10 Amps) for UL standard.
Note: For wiring of AC input connector, refer to Connecting SL STRIP 10IP LED Luminaires to AC Power.
Table 1-1: SL STRIP 10IP LED Luminaires Voltage vs. Current
For European Standard
Voltage (AC)
Total Current (A)
For UL Standard
Voltage (AC)
Max Connected
100
1.50
6
120
220
230
1.25
0.68
0.65
8
14
Total Current (A)
Max Connected
1.50
100
6
14
WARNING: *These figures are based on the Maximum Allowable Input Current of 10 Amps (and the maximum power supply limit of 150
Watts). Do not overload circuits!
IMPORTANT AC POWER CONNECTION NOTES:
When using the daisy-chain connection method, ONLY connect SL STRIP 10IP LED Luminaires to the AC Output Connection of other
SL STRIP 10IP LED Luminaires. DO NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES
Use only use approved cable types.
Do not overload circuits!
Do not connect SL STRIP 10IP LED Luminaires to dimmed circuits.
The MAXIMUM allowable number of SL STRIP 10IP LED Luminaires which can be 'daisy chained' on one 10A power feed is listed in
Table 1-1. DO NOT EXCEED!
Connecting Power
Units can be powered in one of two ways:
D irect connection to an AC power source using an AC input cable. For wiring of AC input connector, refer to Connecting SL STRIP 10IP
LED Luminaires to AC Power.
C onnection from the AC output of another SL STRIP 10IP LED Luminaire. When using this method, it is very important not to
connect any other type of equipment.
WARNING: Only connect other SL STRIP 10IP LED Luminaires to the AC Output (Thru) connector of a SL STRIP 10IP LED Luminaire.
Connecting SL STRIP 10IP LED Luminaires to AC Power
For European Market
Table 2, AC Input Connections describes how to connect power to your SL STRIP 10 IP. Field wiring of the SL
STRIP 10 IP is straight forward. A total of 3 wires/conductors is supplied to the unit.
Table 2: AC Input Connections
Wire Color
Main/Line(100 to 240 VAC)
Blue
Neutral
Ground(Earth)
Yellow
POWER REQUIREMENTS
3
Purpose
Brown
SL STRIPOverview
10 IP LED Luminaires
Layout
Installation and User's Manual
For North American Market
The luminaire is equipped with an IP rated connector and an AC Input cable is provided.
Rear Panel Overview
1
POWER INPUT
(15A Max.)
POWER INPUT(输⼊电压): 110-240V~, 50/60Hz;
POWER CONSUMPTION(功耗): 150W Max.
RDM/DMX
INPUT
110-240V~
50/60Hz
FOR SAFETY INSTRUCTION AND MOUNTING OPTIONS
REFER TO USER MANUAL
POUR INSTRUCTION DE SECURITE ET OPTIONS DE
MONTAGE RÉFÉRER AU MANUEL UTILISATEUR
警告:机 器 在 接 电 前 请 参 阅 安 装 ⼿ 册 , 使 ⽤ 带 安 全 接 地 的 电
源插座;本机器有电击风险,⾮专业⼈员切勿私⾃打开机
壳,维修前请先切断电源。
DO NOT STARE AT THE OPERATING LIGHT SOURCE
SL STRIP 10IP
CAUTION / ATTENTION:
RISK OF ELECTRIC SHOCK DO NOT OPEN
RISQUE DE CHOC ÉLECTRIQUE NE PAS OUVRIR
NOT FOR HOUSEHOLD USE.
IMPROPREA L'USAGE DOMESTIQUE
DRY LOCATIONS
EMPLACEMENTSSECS
NOT FOR RESIDENTIAL/ HOUSEHOLD USE
PAS POUR USAGE RÉSIDENTIEL/ MÉNAGE
MODE
UP
DOWN
MENU
Minimum safety distance to flammable materials: 0.2m.
Distance de sécurité minimale aux matériaux inflammables: 0.2 m.
Minimum safet y dista nce from lighte d objects: 0.5m
Distance de sécurité minimale des objets illuminés: 0.5m
Maximum operating temperature of enclosure surface is 60 °C
Température de fonctionnement maximale de la surface de l'enceinte est de 60 °C
40oC
0.2m
IP65
POWER THRU
(15A Max.)
RDM/DMX
OUTPUT
Made in China 中国制造
110-240V~
50/60Hz
2 345
6 7
8 9
1. LCD Display
This multi-function display details all DMX Address, Chase , Program, Speed activity that pertains to the current
operation mode of the unit.
2. Mode button
This button toggles the unit's operating mode between DMX, Chase and Manual mode.
3. UP button
This button increases the displayed value in the LED display.
4. Down Key
This button decreases the displayed value in the LED display.
5. Menu button
This button selects the different functions in DMX Mode, Chase Mode and Manual Mode.
6. AC Input Connector:
AC110-240V~50/60Hz, Max15A. Be sure to always connect to the proper voltage.
7. RDM / DMX Input Connector
8. RDM / DMX Output Connector
9. AC Output Connector:
AC110-240V~50/60Hz, Max15A. This connector outputs the mains supply to the next unit.
4
LAYOUT OVERVIEW
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
OPERATION MODES
The SL STRIP 10IP LED Luminaire has three different operation modes.
Please follow illustrations below to operate the unit in your desired mode.
Mode
Parameter
DMX
Chase
Manual
Calibration
Function
Parameter Value
Address
001-512
To set the initial DMX receiving address
Channel
8 Bit:1/2/5/10 pixel 16 Bit:1/2/5/10 pixel
To set the DMX Control Mode
DMX Fade
OFF/ON
To set the status of the fixture when there is no DMX input
Program
01-10
To select a built-in program
Speed
01-99
To set the speed level of the built-in Program
Dimmer
000-255
To set the intensity
Fade
000-100
To set the speed of the Fadetime(percentage)
R
000-255
To set the output intensity of the red
G
000-255
To set the output intensity of the green
B
000-255
To set the output intensity of the blue
W
000-255
To set the output intensity of the cool white
Can be set as ON or OFF
DMX Mode
Use this mode to use the unit as a DMX dimmer. Set the unit control zones as 01 pixel, 02 pixel, 05 pixel,or 10 pixel.
Set the DMX Start Address, and the fixture behaviour without DMX input.
SL STRIP 10IP DMX Mapping (RGBW 16 Bit Mode)
Red _ 9-10 - High Byte
Red _ 9-10 - Low Byte
Green _ 9-10 - High Byte
Green _ 9-10 - Low Byte
Blue _ 9-10 - High Byte
Blue _ 9-10 - Low Byte
White _ 9-10 - High Byte
White _ 9-10 - Low Byte
OPERATION MODES
5
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
SL STRIP 10IP DMX Mapping (RGBW 16 Bit Mode)
SL STRIP 10IP DMX Mapping (RGBW 8 Bit Mode)
Red_1-10
Green_1-10
Blue_1-10
White_1-10
6
OPERATION MODES
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
1. Setting the DMX Address
Press the “MODE’ button to select and activate the “DMX” menu.
Set the DMX address, DMX Bit, DMX Fade and DMX Channel. Press
the “MENU” button to select and enter the desired menu.
DMX Addr
Addr:512
MODE
UP
DOWN
MENU
The DMX Address Mode is indicated by “DMX Addr” followed by three
digits 001~512. Press the "UP " and "DOWN" buttons to change the
DMX Address Value.
2. Setting the DMX Bit resolution
DMX Bit
8 Bit
Press the “MENU” button to select and activate the “DMX Bit” menu.
Press the "UP " and "DOWN" buttons to change the DMX Bit Value
between 8 Bit and 16 Bit.
MODE
UP
DOWN
MENU
3. Setting DMX Fade On/OFF
Press the “MENU” button to select and activate the “DMX Fade” menu. Press
the "UP " and "DOWN" buttons to set the DMX Fade on or off.
DMX Fade
Fade on
MODE
UP
DOWN
MENU
4. Setting the DMX Channel
DMX Ch
1 Pixel
Press the “MENU” button to select and activate the “DMX Ch” menu.
Press the "UP " and "DOWN" buttons to change the DMX Channel
Value between 1 pixel, 2 pixels, 5 pixels and 10 pixels.
MODE
UP
DOWN
MENU
Chase Mode:
The unit has 10 built-in chase programs. Use this mode to select a built -in chase and edit the speed and fade
information.
1. Setting the Chase Program:
Press the “MODE” button to activate the Chase Mode. Press the “MENU”
button to select and activate the“Chase Program” menu. The chase pattern is
displayed in the LCD as "Chase Prog " followed by the chase number. Press
the “UP” and “DOWN” button to select and activate the desired chase.
Chase
Prog:01
MODE
UP
DOWN
MENU
SETTING THE DMX ADDRESS
7
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
2. Chase Speed Menu:
Press the “MENU’ button to select the “Chase Speed” menu.
In this menu, you can adjust the program chase speed.
Chase
Speed:01
MODE
UP
DOWN
MENU
Press the "UP " and "DOWN" buttons to adjust the chase speed from 01
to 99. A value of 99 will give you the fastest chase speed
(approx.1/10th of a second) . A value of 01 will give you the slowest
chase speed (once every 30 seconds).
3. Chase Fade Menu:
Press the“MENU” button to select the“Chase Fade” menu.
In this menu, you can adjust the program fade speed.
Chase
Fade:000
MODE
UP
DOWN
MENU
Press the "UP " and "DOWN" buttons to adjust the fade speed from 000
thru 100.
4. Chase Dimmer Menu:
Press the “MENU” button to select the “Chase Dimmer” menu.
In this menu, you can adjust the program light output.
Press the "UP" and "DOWN " buttons to adjust the light output
intensity from 000 to 255. A value of 000 will give you the
minimum output intensity and a value of 255 will give you the
maximum output intensity.
Chase
Dimm:000
MODE
UP
DOWN
MENU
Chase
Dimm:255
MODE
UP
DOWN
MENU
Manual Mode:
Use this mode to manually set the Red, Green, Blue, and Cool White intensity.
Press “MODE” button to select and activate “Manual”
menu. In this menu, you can adjust the intensity of each color. Press
“MENU” button to toggle the color between R, G, B and W.
Manual:
R:000
MODE
Press the "UP " and "DOWN" buttons to adjust the color intensity from
000 to 255.
UP
DOWN
MENU
Manual:
G:255
MODE
UP
DOWN
MENU
Note: When the LCD backlight is off, pressing any button will activate the LCD display and show the current
operating temperature.
8
OPERATING MODE
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
SL STRIP 10IP RDM Parameter IDs
The following tables outline and describe all the RDM parameters IDs associated with SL STRIP 10IP.
Table 1: SL STRIP 10IP RDM Parameter IDs
SL STRIP 10IP
82H
0x1000
0x0105
Philips Entertain. Lighting Asia
SL STRIP 10IP
RDM PARAMETER IDS
9
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
Table 1: SL STRIP 10IP RDM Parameter IDs
10
RDM PARAMETER IDS
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
Table 2: SL STRIP 10IP Manufacturer Status IDs
Manufacturer Defined Status IDs
Manufacturer Specific messages are in the range of 0x8000 —0xFFDF. Each Manufacturer-specific Status ID shall
have a unique meaning, which shall be consistent across all products having a given Manufacturer ID. See Table B-2,
ANSI E1.20-2010
Status Message ID
Value
Data Value 1
00H
8100H
Status ID Description
Data Value 2
00H
ALL OK
Table 3: SL STRIP 10IP Manufacturer Specific PIDs
Manufacturer Specific PIDs
Manufacturer Defind PIDs range is 0x8000-0xffdf. See Table A-3, ANSI E1.20-2010
Get
SET
RDM Parameter
Allowed Allowed
Id’s
TYPE LENGTH
UNIT PREFIX
MIN
MAX DEFAULT DESCRIPTION
8A00H
U8
1
NONE
NONE
0
1
0
DMX Fade on/off
8AB2H
U8
1
NONE
NONE
1
10
1
Chase program
8AB1H
U8
1
NONE
NONE
0
99
0
Chase Speed
8A92H
U8
1
NONE
NONE
0
100
0
Chase Fade
8A94H
U8
1
NONE
NONE
0
255
0
Chase Dimmer
8AA1H
U8
1
NONE
NONE
0
255
0
Manual red
8A0CH
U8
1
NONE
NONE
0
255
0
Manual green
8AA0H
U8
1
NONE
NONE
0
255
0
Manual blue
8AA2H
U8
1
NONE
NONE
0
255
0
Manual white
8A44H
U8
1
NONE
NONE
0
1
0
Calibration On/off
MANUFACTURER STATUS IDS
11
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
TECHNICAL SPECIFICATIONS
1. Operational Specifications
Source:
Beam Angle:
Light Output:
Color Temerature:
Input Voltage:
Power Consumption:
Frequency:
Control Protocols:
Ambient Temperature:
Humidity:
Cooling:
Weight:
Housing:
Compliance:
IP Rating:
10 homogenized 4-in-1 RGBW LED Arrays
6 degree native beam angle. 15, 25 or 11 x 38 degree diffuser lens
2240 lumens
2700 - 6500K (user adjustable)
100V to 240V(+/- 10%, auto-ranging)
150 Watts(max).
50/60Hz
DMX512(1990) / DMX512A (RDM) / On-Board Menu
-20 to 40 Degrees C ( -4 to 104 Degrees F)
5%-95% Non condensing
Silent passive cooling
7.5kg (16.5 lbs) - Luminaire only (no mount, AC input cable or accessories)
Die Cast aluminium with Powder Coating
CE / C-Tick marked and ETL listed
IP65
Note: Common model specifications shown. For specific model specifications, features, and accessories, refer
to the product specification sheet for more details.
1. Luminaire Dimensions
12
TECHNICAL SPECIFICATIONS
SL STRIP 10 IP LED Luminaires
Installation and User's Manual
13
Dallas
10911 Petal Street
Dalls, TX 75238
Tel: +1 214-647-7880
Fax: +1214-647-8031
Asia
Unit C, 14/F, Roxy Industrial Centre
No. 41-49 Kwai Cheong Road
Kwai Chung, N.T., Hong Kong
Tel: +852 2796 9786
Fax: +852 2798 6545
Auckland
19-21 Kawana Street
Northcote, Auckland 0627
New Zealand
Tel: +64 9 481 0100
Fax: +64 9 481 0101
Europe
Rondweg zuid 85
Winterswijk 7012 JD
The Netherlands
Tel: +31 (0) 543-542516
C 2015 Philips Group
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising