Automatic Detectors Accessories Accessories for Several Detector

Automatic Detectors Accessories Accessories for Several Detector
Automatic Detectors
Accessories
Accessories for Several Detector Series
805580
¬qXq5−
Detector removal tool
It is suitable for removing Series 9x00 as well as IQ8Quad detectors. Through optional adaptation of the suction cup in the respective insertion on the detector removal tool, the
IQ8Quad detector covers (Part Nos. 805588 + 805589) and the base covers for IQ8Quad
(Part No. 805587) can be attached as well as removed. The detector removal tool can be
adapted to the telescope rod part no. 060426 and 060427 as well as with 805581 to 769813.
128
www.esser-systems.com
Automatic Detectors
805581
¬qXr8−
Accessories
1
Adapter for Esser pole (Part No. 769813)
The adapter for the 769813 pole is designed for attaching the 805580 detector removal tool
and the 805582 smoke detector tester.
2
3
4
060427
¬'%<¤−
5
Plastic telescopic rod
Extendable detector pull-down pole made of glass-fibre reinforced plastic for adapting the
805580 detector removal tool as well as testers with Part Nos. 060429 and 805582.
6
Technical Data
7
Length
max. 4.5m
8
Features
9
• Length of 1.26m in retracted state
• 4 segments, lockable
10
060426
¬'%;¡−
Plastic telescopic extension
11
Telescopic extension for plastic telescopic rod (Part No. 060427). Up to 3 telescopic extensions can be attached to the telescopic rod. The maximum height that can be reached is
increased to 9m.
12
Technical Data
Length
1.13m
13
14
129
Automatic Detectors
805551
¬qXTE−
Features
• Generation of smoke, heat and CO in a single
test unit
• Clearing cycle of the detector via integrated
ventilator for better reset
• Simultaneous or sequential testing with various
stimuli
• Suitable for single and multi-criteria detectors
• Suitable for smoke-, heat- and gas- (CO) detectors
• Targeted heat rays provide fast activation of
heat sensors (up to 90°C/194°F, and/or adjustable up to 100°C/212°F)
• Test activation via infrared barrier, no mechanical triggering, no ceiling contact necessary
• Easy, fast and efficient testing, as changing of
testing device is not necessary
• Multilingual and user-friendly menu control
• Battery operated portable device
• Environmentally friendly and safe through
usage of test cartridges instead of test gas
cans
Accessories
Multi-stimulus detector tester
Detector tester kit Testifire 2001 for the functional testing of point-type fire detectors with
various sensors. The activating stimuli for smoke, heat and CO (carbon monoxide) are generated in this testing unit. Thus the changing of test tools for different types of detectors is
no longer necessary.
All fire detector types can be tested with only one test instrument. The test tool is suitable
for all optical smoke detectors, ionization detectors, CO detectors and heat detectors. It facilitates fast and effective testing of single and intelligent multi-sensor detectors. So testing
of the different sensors can be carried out one after another or for all at the same time.
The required stimuli are generated on demand at the time of test from the corresponding
capsule (smoke or CO). Pressurized gas cans are no longer being used.
The selection of the testing stimuli, as well as their combination and sequence are menu
driven via keypad and are represented on the display (multilingual). So e.g. simultaneous or
sequential testing, or also a combination thereof, can be easily programmed and then carried out at the detector. The activation of the testing device occurs automatically, as soon as
the detector interrupts the light barrier integrated in the device. If necessary, a clearing
phase can be chosen between the respective testing criteria that enables the stimuli to be
blown out of the detector immediately for the next test by the integrated ventilator.
The respectively active criterion is represented by a multi-coloured LED indicator and is clearly recognizable even from large distances. The fill-level of the respective test resources
capsules can be shown in the display. Warnings are indicated automatically e.g. if a capsule
is nearly empty. The capsules offer a much higher test capacities in comparison with aerosol
cans.
The power supply of the testing head occurs via Ni-MH batteries (metal hydride batteries)
in the adapter between testing head and telescopic rod. Charging of the battery occurs with
the charger optionally via adapter (100-230 V AC) or via 12 V DC input (vehicle cigarette
lighter).
Suitable for IQ8Quad and 9x00 detector series.
Technical Data
Heat detector response threshold
Ambient temperature
Storage temperature
Relative humidity
Battery charging time
up to 90°C adjustable up to 100°C
+5°C to +45°C
-10°C to +50°C
max. 90 % (without formation of condensation)
75-90 minutes
Detector tester kit Testifire 2001 consist of:
Testing head, smoke capsule, CO capsule, 2 Ni-MH battery packs, charger
Selection of different test criteria displayed
Accessories:
805552
805553
060426
060427
060431
130
www.esser-systems.com
Smoke capsule for Multi-stimulus detector tester 805551 (Testifire TS3)
CO capsule for Multi-stimulus detector tester 805551 (Testifire TC3)
Plastic telescopic extension
Plastic telescopic rod
Spare battery baton
Automatic Detectors
805552
¬qXUH−
Accessories
1
Smoke capsule for Multi-stimulus detector tester 805551
Replacement smoke capsule (Testifire TS3) for the testing of smoke detectors series
IQ8Quad and 9x00 with optical and/or ionisation sensors. Suitable for the multi-stimulus
detector tester 805551.
2
3
4
Features
5
• Non-flammable, non toxis materials
• Production of test gas only during the testing
• Does not cause any residue in the sensor
chamber
• Suitable for optical and ionization detectors
• No test gas storage under pressure – no dangerous good
• More productivity than the spray can
805553
¬qXVK−
6
7
CO capsule for Multi-stimulus detector tester 805551
8
Replacement CO capsule (Testifire TC3) for the testing of detectors with carbon monoxide
sensors (CO). Especially suited for the IQ8Quad OTG Multisensor Detector 802473 (with CO
sensor). Suitable for the multi-stimulus detector tester 805551.
9
The IQ8Quad OTG multisensor detector (CO) 802473 is generally tested either
- with the test gas 060430.10, suitable for the smoke detector tester 805582, or
- with 805552, suitable for the muli-stimulus detector tester 805551.
10
The 802473 is VdS-approved as a smoke detector, the CO test gas is required for the additional
triggering of the electrochemical CO gas cell.
11
Features
• Non-flammable CO activating-material
• Generation of small amounts of CO
• Generation of CO during testing only
• No storing of pressurized CO - no dangerous
good
• More productivity than the spray can
805582
¬qXs;−
12
13
14
Smoke detector tester
The smoke detector tester is designed for electric function control for the IQ8Quad and
Series9x00 detectors. After an aerosol has been released, the operation capacity of the measuring chamber can be tested by using the transceiver. The smoke detector tester is adapted
to the rod (Part No. 060427).
The telescopic rod is not supplied as standard.
Accessories:
060426
060427
Plasitc telescopic extension
Plastic telescopic rod
131
Automatic Detectors
060430.10
¬'%?§/21f−
Accessories
Test gas for smoke detecetor tester 805582
For IQ8Quad and series 9x00 detectors, suitable for smoke detector tester 805582.
Technical Data
Content
250ml per bottle
Not suitable for Series 9000, 9100 and 9200 ionisation smoke detectors.
Please take note that this item has to be handled as dangerous good (aerosols, non-flammable,
UN1950)
805583
¬qXt>−
CO test gas for smoke detector tester 805582
Test gas for testing carbon monoxide CO-detectors. Specifically designed for the OTG multisensor (CO) IQ8Quad 802473, suitable for smoke detector tester 805582.
Technical Data
Content
250ml per bottle
The OTG multisensor detector (CO) IQ8Quad (Part No. 802473) should only be tested in connection with test gas 060430.10 suitable for smoke detector tester 805582. Detector 802473
has been approved as smoke detector by VdS and the CO test gas is used to additionally trigger
the electrochemical CO-gas cell.
Please take note that this item has to be handled as dangerous good (aerosols, non-flammable,
UN1950)
805586
¬qXwG−
Carrying bag for test equipment including cover for telescopic rods
The carrying bag has many pockets and compartments in which the ESSER smoke alarm
testers, test gas bottles, all cables and other maintenance accessories can be stored. So
everything you need for maintenance can always be found in one place. The upholstered,
adjustable shoulder strap ensures a very easy and comfortable transport. An additional
advantage: The bag protects equipment from dirt and moisture.
Technical Data
Dimensions (W x H x D)
Features
• Exterior lid with Velcro fastening transportation
straps for telescopic rod and extensions
• Inside lid with 2 storage compartments for battery backs 060431
• Inside compartment with up to three optional
dividers
• Big front pocket, with up to two optional dividers
• Wide shoulder strap with sliding shoulder pad
and additional handles
• Cover with carrying strap for up to 4 telescopic
rods 060427 and/or extensions 060426
132
www.esser-systems.com
480 x 420 x 260 mm (carrying bag)
1 x carrying bag and 1 x cover for telescopic rods/ extensions
Automatic Detectors
060429
¬'%>!−
Accessories
1
Test head for heat detector together with battery and charger
Device for testing mounted fixed temperature, rate-of-rise and combination detectors when
already installed. Response level of up to 90°C. Power supply of test head occurs via NiMH
battery in the adapter between test head and telescopic rod. Can be used for detector series
S-3000, 9x00 and IQ8Quad. The battery is recharged either with the charger or via mains
supply (115V AC/230V AC) or via 12V DC cigarette lighters in vehicles.
2
3
Technical Data
Features
• Mains cable is not required for testing
• Power supply with rechargeable NiMH battery
in the adapter of the telescopic rod
• Time based termination of testing after 120
seconds in order to prevent any heat related
damages of the detectors
• Detector head is switched off after not being
used for 5 minutes
• Adjustable inclination angle of detector head
for an optimal orientation towards the object
which has to be tested
• Testing height up to 6 metres with telescopic
rod and up to 9 metres with its extension
device
• Excess-current protection for the battery
• Display of operating status of the detector head
with Duo-LED (red/green)
• Battery can be charged via mains supply or via
cigarette lighter in vehicles
060431
¬'%@'−
Ambient temperature
Storage temperature
Relative humidity
Battery charging time
Batteryr life-time
+5°C to +45°C
-10°C to +50°C
max. 85% (non-condensing)
75-90 mins. (if completely discharged)
at least 500 charge/discharge cycles
4
5
Test head, 2 battery batons, charger
6
Accessories:
060426
060427
060431
Telescopic extension
Plastic telescopic rod
Spare battery baton
7
8
9
10
Spare battery baton
Replacement battery pack (NiMH) for Test Head 060429 and 805551.
11
12
13
769870.20
¬m¥g§/31J−
Smoke detector tester
14
Smoke detector tester allows fast and reliable functionality testing for Series IQ8Quad and
9x00 smoke detectors. Through reduced mechanically controlled actuation pressure,
suspended installed detectors can also be tested. Control electronics guarantee a defined
spray impulse. Spray can and batteries can be easily replaced.
Technical Data
Operating voltage
Testing capacity
2 x 9V batteries
approx. 2000 applications / can
Telescopic rod 769813 is required.
Substitute for 769870.10!
1 x test gas 769070
2 x9V batteries 018051
1 x bellow for IQ8Quad and 9x00
Accessories:
769070
018051
Test gas
9V battery
133
Automatic Detectors
769871.20
¬m¥h§/31M−
Accessories
Conversion kit for smoke detector tester 769870
The conversion kit (Part No. 769871.20) is used to convert the smoke detector tester (Part
No. 769870 and 769870.10) to test the functions of IQ8Quad and 9x00 smoke detectors.
The conversion kit includes special contact fields to test smoke detectors and the associated expansion bellows.
Substitute for 769871!
1 x bellow for Series IQ8Quad and Series 9X00
1 x contact spring
3 x fixing screws
769070
¬m{gY−
Test gas for smoke detector testers 769870.10 and 769870
For series 9x00 and IQ8Quad detectors.
Technical Data
Content
150 ml
CFC-free test gas, suitable for approx. 2000 applications.
Please take note that this item has to be handled as dangerous good (aerosols, flammable,
UN1950).
769813
¬m¥.%−
Telescopic rod
For smoke detector tester 769870.20 (length 3.75 m, three pieces, locking devices).
Technical Data
Length
769814
¬m¥/(−
3.75m, three parts, lockable
Extension pole
For smoke detector tester 769870.20, detector removal tool 769804 and telescopic rod
769813 (length 4m, two pieces, locking devices).
Technical Data
Length
134
www.esser-systems.com
4m, two parts, lockable
Was this manual useful for you? yes no