Fire Alarm System
Fire Alarm System
VER.17.1
AWEX BRAND
RESEARCH
The AWEX brand has existed since 2002, and has
been carrying out clearly defined mission: modern
products with the highest quality and the satisfaction
of customers. We offer the full range of products
concerning emergency lighting which meet European
standards. Within 15 years of our presence on the
market, due to involvement of our knowledge, funds, cooperation with the best specialists, including research
facilities, and investments in innovative undertakings
we achieved the position of the leader in the industry.
AWEX company means the most modern technologies,
expert team of designers and engineers, the highest
quality, reliability of devices, diversified offer, unique
design, unlimited production capacity and flawless
reputation confirmed by references. Satisfaction and
trust of our customers is our greatest prize. We also
enjoy the consideration of independent experts. We
were awarded with the title:
“Export Leader 2006” [„Lider Eksportu 2006”] for a sales
level achieved, and the Puls Biznesu awarded us twice
with the „Gazele Biznesu” distinction as one of the most
dynamically developing companies.
Research and development conducted by us guarantee
constant update of our offer oriented towards the
development of the industry, due to which we provide
the most modern, multifunctional and technologically
advanced products.
PROFESSIONAL PERSONNEL
We employ the best specialists in many fields whom we
guarantee constant improvement of their qualifications
through specialised trainings. Our design department
provides flexibility adjusted to individual needs, and the
team of highly qualified engineers guarantees constant
technical progress of devices offered by us. Application
of the modern methods of the flow of information
in the company allows us to keep our offer, as well
as functionality of the products up-to-date. Effective
projects management allows us to establish solid
relationships with our counterparties, based on trust.
INVESTMENTS
We apply the latest world technologies which guarantee
quality, precision in production, the optimisation of
technological process and work ergonomics. We invest
our time and funds to make each stage of manufacture
of our products contributing to meet all expectations
on the part of our clients.
WE CARE ABOUT ENVIRONMENT
We offer products which are friendly for the natural
environment, and the technological process meets high
standards of the EU.
GUARANTEE OF QUALITY
With a view to doing the mission of our company, we
have implemented the Quality Management System
according to the EN ISO 9001:2008 standard, and the
certificate issued to us by TÜV NORD guarantees the
highest quality of design, manufacture, assemble and
service of manufactured devices.
CONTENTS
Control units
4
FIRE ALARM CONTROL UNIT FAS 5
CONTROL UNIT EXTENTION CARDS
External signal panel ESP
CENTRAL NETWORK
Fire detectors
7
8
9
10
SMOKE DETECTOR S
11
HEAT AND SMOKE DETECTOR TS
13
HEAT DETECTOR T
Smoke detector with the visual signalling device SF
HEAT DETECTOR WITH THE VISUAL SIGNALLIG DEVICE TF
Heat and smoke detector with the visual signalling device TSF
MANUAL CALL POINTS
MANUAL CALL POINT ROP 21
MANUAL CALL POINT ROP 65
INPUT/OUTPUT MODULES
12
14
15
16
18
18
19
20
INPUT/OUTPUT MODULE MIO 22
20
INPUT/OUTPUT MODULE MIO 44 20
INPUT/OUTPUT MODULE MIO 88
20
INDICATORS21
STATUS INDICATOR WZ 4
21
Accessories22
Fire Alarm System
Control units
CONTROL UNITS IN THE FIRE ALARM SYSTEM
The control units are intended collect alarm signals from the elements located on supervisory
lines. Grouped information are presented on the screens of user panels in the order dependent
on their type and priority of display. Due to such application, communications are legible and
clear for all users of the system. Seven-inch display connected with a transparent interface
gives the possibility of easy and quick configuration of the system. The built-in controller while
interpreting introduced settings controls the devices intended to protect a facility against fire.
4
Fire Alarm System
Control units
FIRE ALARM CONTROL UNIT FAS
The control unit is manufactured in the module technique which makes it easy to expand and
service. In the basic it has a user’s panel, a control module with a supervisory loop, a power
supply unit and a set of batteries. You can expand and adjust the control unit to your own need
through installations and programming appropriate expansion cards.
Characteristics of the control unit FAS
•Up to 7 supervisory loops
•Up to 250 elements per a loop
•Up to 250 supervisory zones per
a loop
•Outputs built-in
•UTA
•Signal lines
•Fault
•Universal relay
•Maximum loop length 2000m
•Loop interval detection
•Events counter up to 15,000
•Expansion cards
•Conformity with EN 54-2, EN 54-4
standard
•7-Inch touch screen
•Printer built-in
•Modbus, BACnet interface
Optionally, the control units may be monitored through the TCP/IP protocol. Remote access to
the system service is available through dedicated software or on the website.
Application of the RJ-45 connector and the IP technology allows to integrate the system and
the building management systems (BMS), with the Safety management systems (SMS) and the
visualisation systems (SMART VISIO).
ROUTER
NETWORK
PC
BMS BUILDING
MANAGEMENT SYSTEM
5
Fire Alarm System
Control units
TECHNICAL DATA
Name
Fire alarm control unit FAS
Type
Addressable
Supply voltage
170-260 V AC 50 Hz
Wires cross-sections
2.5 mm² maximum
Output power
20-30 V DC
Events counter
15000
Casing
Powder-coated steel, RAL 3000
Tightness level
IP 30
Batteries
26 Ah / 52 Ah
Printer
Yes, optionally
Permissions levels
4 levels
Types of supervisory lines
Loop, branch, side lines
Maximum number of supervisory loop lines
Maximum number of supervisory branch lines
Maximum number of supervisory zones
7
14
250 per a loop
Maximum number of elements of a loop line
250
Maximum number of elements of a branch line
32
Number of signal lines outputs
2
Alarming variants
16
LAN Input
Yes
Universal inputs
8 maximum
Universal relay outputs Length
7 maximum
of supervisory line wire
2 km
Supervisory line wire cross-section
570
0.8 – 1.5 mm²
794
358
358
6
165
Fire Alarm System
Control units
CONTROL UNIT EXTENTION CARDS
TECHNICAL DATA
Name
Installation
Number of supervisory loops
Line structure
Maximum number of elements
Maximum length of a wire
Maximum number of cards
Product code
Supervisory loops card KPD 2
inside the FAS control unit
2
loop, branch
up to 250 per a loop
2000m
3
FSC0000001
TECHNICAL DATA
Name
Input/Outputs card KIO 22
Installation
inside the FAS control unit
Monitoring
input signal monitoring
Number of inputs
Number of outputs
Maximum input load
Maximum number of cards
Product code
2 supervised inputs
2 relay outputs
30V DC 0.5A
3
FSC0000002
TECHNICAL DATA
Installation
Communication card KRS 422
Maximum number of central units
inside the FAS control unit 10
Maximum number of remote
control panels
Maximum length of a wire
Maximum number of cards
10
1000m
1
Connection type
doubled loop
Product code
FSC0000003
7
Fire Alarm System
Control units
External signal panel ESP
The ESP panel allows to control the fire alarm control unit from a place which is distant from
a physical localisation of the control unit by reproducing its interface by displaying, among
others: alarm, fault, block and test communicates.
Due to application of the remote control panel, the fire alarm control unit may be installed in
the most comfortable place from the point of view of the topology of the system, whilst the
panel may be placed near the personnel handling the fire alarm system.
It is possible to verify alarming of the control unit, and then, remove the signalling. The panel
controls its own systems and signals their possible fault. Efficiency of the signalling elements
of the terminal can be tested. Accessibility to the manipulative elements and determined
functions was diversified and divided into the access levels.
Characteristics of the ESP remote panel
•Double interface of the control unit
•7-Inch touch screen
•4 levels of access
•Multi-language service
•Access blockade by using a key
•Compact casing
Dimensions (mm):
TECHNICAL DATA
Name
184
Device type
Protection degree
Range of operating temperatures
Dimensions
49
IP 30
-5° C to +40° C
263x184x49mm
24V DC
Maximum current consumption
150mA
Maximum number of devices
8
The device for remote signalling
and servicing
Supply voltage
Weight
263
External signal panel ESP
Product code
2000g
10 per a network
FSP0000001
Fire Alarm System
Control units
CENTRAL NETWORK
FAS control units can be combined to create the network of correlative control units. On the
communication line of the network it is also possible to connect the ESP remote panels which
allow to control the condition of each of the control units, as well as configure particular
control units.
TECHNICAL DATA
Network of central units
10 control units
Topology of control units
Ringed, Correlative
Wire type
Connection Distances between the
FTP
YnTKSYekw
Fiber-optic cable
1000m
500m
5000m
9
Fire Alarm System
Fire detectors
Fire detectors of the AWEX fire alarm systems are intended for detecting fires in their early
phase. The detectors, because of their types can have the following sensors: heat, smoke, or
combined sensors of smoke and heat, and an additional visual indicator. Detection systems
applied in the detectors guarantee certainty and reliability in detecting fire. The heat detection
is realised by means of 4-thermistor ambient temperature measurement system, on the other
hand, the smoke detection system is being realised by means of photodiodes which uses
the phenomenon of light dispersion. In case of detectors equipped with both fire detection
systems it is possible, depending on a need an the place of installation, turn off one of the
sensors using the control unit by selecting appropriate detector operation mode.
Every element is equipped with double-sided short-circuit isolator which ensures continuous
operation of the loop, despite a short-circuit on the line and enables an easy localisation of a
fault. Additionally, the detectors are monitoring their state of soiling continuously by sending
the information on a possible need of their cleaning to the control unit. State of soiling is
taken into consideration in the detection algorithm, thereby increasing the certainty of the
fire detection.
10
Fire Alarm System
Fire detectors
SMOKE DETECTOR S
The smoke detector is intended for detecting fire in its early phase. The detector has an optic,
scattering smoke sensor. The application of such type of a sensor allows to detect fire quick
and with certainty.
The detector operates within the AWEX fire alarm system. The element can be installed on the
loop addressable supervisory lines and on the side addressable line.
The smoke detection takes place in a detection chamber equipped with photoelectric diodes.
Smoke goes to the chamber during fire. The particles of smoke reflect the light emitted by
light emitting diodes which causes that an IR diode receives the signal and transmits it to a
microprocessor. Then, it recognises the type of alarm and transmits it to the supervisory line,
and to the control unit.
Characteristics of the smoke detector:
•The level of sensitivity comply with the EN 54
standard
•Recognition of the state of soiling
•Regulation of alarm threshold which compensates
the influence of the environment
•Indication of an alarm by means of the LED diode
•Additional LED diodes for the testing state
•External status indicator
•The possibility of disconnection of particular
detectors
•Integrated short-circuit isolator
•A casing with a low profile
•Operation in the addressable systems
110
Dimensions (mm):
TECHNICAL DATA
Name
Smoke detector S
Smoke detection
optical, scattering
Supply voltage
24V DC
Current during supervision
<160 μA
Current during alarming
Working temperature
Tightness protection level
51
Acceptable relative humidity
110
Visual signalling
Dimensions
<550 μA
from -25°C to 55°C
IP 20
95% at the temp. of 35°C without
condensation LED diode, red, green
Ø110 x 51 mm
Weight
200 g
Detector colour
White
Usefulness for test fires detecting
Product code
According to 54-7
FSD0000002
S detector operation mode
11
Fire Alarm System
Fire detectors
HEAT DETECTOR T
The heat detector is intended for detecting fires in their early phase. The detector has a
thermistor heat detection system. The application of such type of a sensor allows to detect
fires quick and with certainty. The detector operates within the AWEX fire alarm system.
The element can be installed on the loop addressable supervisory lines and on the side
addressable line.
The heat detection takes place by means of 4-thermistor temperature measurement system.
A fire alarm is generated when temperature limit is achieved, or in case of quick increase of
temperature. Then, it recognises the type of alarm and transmits it to the supervisory line,
and to the control unit.
Characteristics of the heat detector:
•Sensitivity degree and the temperature class
comply with EN 54.
•Regulation of alarm threshold which compensates
the influence of the environment
•Indication of an alarm by means of the LED diode
•Additional LED diodes for the testing state
•External status indicator
•Integrated short-circuit isolator
•A casing with a low profile
•Operation in the addressable systems
Dimensions (mm):
TECHNICAL DATA
Name
110
Heat detector class
Heat detection
24V DC
Current during supervision
<160 μA
Working temperature
Tightness protection level
Acceptable relative humidity
51
Visual signalling
Dimensions
12
<450 μA
from -25°C to 55°C
IP 20
95% at the temperature of 35°C
without condensation
LED diode, red, green
Ø110 x 51 mm
Weight
200 g
Detector colour
White
Product code
T detector operation mode
A1R
Overload, differential,
Supply voltage
Current during alarming
110
Heat detector T
FSD0000001
Fire Alarm System
Fire detectors
HEAT AND SMOKE DETECTOR TS
The heat and smoke detector is intended for detecting fires in their early phase. The detector
has two sensors: heat and smoke. The application of two types of a sensor allows to detect
all types of fires quickly and with certainty. The detector operates within the AWEX fire alarm
system. The element can be installed on the loop addressable supervisory lines and on the
side addressable line.
The smoke and heat detector with two sensors is equipped with two sensors which detect fire.
The smoke detection takes place in a detection chamber equipped with photoelectric diodes.
Smoke goes to the chamber during fire. The particles of smoke reflect the light emitted by
light emitting diodes which causes that an IR diode receives the signal and transmits it to
a microprocessor. The heat detection takes place by means of 4-thermistor temperature
measurement system. A fire alarm is generated when temperature limit is achieved, or in
case of quick increase of temperature. Then, it recognises the type of alarm and transmits it
to the supervisory line, and to the control unit.
Characteristics of the heat and smoke detector:
•Sensitivity degree and the temperature class
comply with EN 54.
•Recognition of the state of soiling
•Regulation of alarm threshold which compensates
the influence of the environment
•Smoke analysis supported by the heat analysis
function
•The possibility of disconnection of particular detectors
•Indication of an alarm by means of the LED diode
•Additional LED diodes for the testing state
•External status indicator
•Integrated short-circuit isolator
•A casing with a low profile
•Operation in the addressable systems
Dimensions (mm):
110
TECHNICAL DATA
Name
Heat detector class
Smoke detection
Heat detector detection
24V DC
<160 μA
Tightness protection level
51
Overload, differential,
Current during supervision
Working temperature
Acceptable relative humidity
Visual signalling
Dimensions
TS detector operation mode
A1R
Optical, scattering,
Working voltage
Current during alarming
110
Heat and smoke detector TS
<550 μA
from -25°C to 55°C
IP 20
95% at the temperature of 35°C
without condensation
LED diode, red, green
Ø110 x 51 mm
Weight
200 g
Detector colour
White
Usefulness for test fires detecting
Product code
According to 54-7
FSD0000003
13
Fire Alarm System
Fire detectors
Smoke detector with the visual signalling device SF
The smoke detector is intended for detecting fire in its early phase. The detector has an optic,
scattering smoke sensor. The application of such type of a sensor allows to detect fire quick
and with certainty.
Additionally, the detector has the flashing visual signalling device built-in due to which the
detector fire alarm is visible from a large distance. The detector operates within the AWEX fire
alarm system. The element can be installed on the loop addressable supervisory lines and on
the side addressable line.
The smoke detection takes place in a detection chamber equipped with photoelectric diodes.
Smoke goes to the chamber during fire. The particles of smoke reflect the light emitted by
light emitting diodes which causes that an IR diode receives the signal and transmits it to a
microprocessor. Then, it recognises the type of alarm and transmits it to the supervisory line,
and to the control unit.
Characteristics of the smoke detector:
•The level of sensitivity comply with the EN 54
standard
•Recognition of the state of soiling
•Regulation of alarm threshold which compensates
the influence of the environment
•Indication of an alarm by means of the LED diode
•Additional LED diodes for the testing state
•External status indicator
•Integrated short-circuit isolator
•A casing with a low profile
•Operation in the addressable systems
Dimensions (mm):
TECHNICAL DATA
110
Name
Smoke detection
24V DC
Current during supervision
<160 μA
Working temperature
Tightness protection level
Acceptable relative humidity
51
Visual signalling
Dimensions
14
<2 mA
from -25°C to 55°C
IP 20
95% at the temperature of 35°C
without condensation
Green LED diode, red FLASH LED diode
Ø110 x 51 mm
Weight
200 g
Detector colour
white
Usefulness for test fires detecting
SF detector operation mode
Optical, scattering
Supply voltage
Current during alarming
110
Smoke detector with
the visual signalling device SF
Product code
According to 54-7
FSD0000005
Fire Alarm System
Fire detectors
HEAT DETECTOR WITH THE VISUAL SIGNALLIG DEVICE TF
The heat detector is intended for detecting fires in their early phase. The detector has a
thermistor heat detection system. The application of such type of a sensor allows to detect
fires quick and with certainty.
The detector operates within the AWEX fire alarm system. The element can be installed on
the loop addressable supervisory lines and on the side addressable line. Additionally, the
detector has the flashing visual signalling device built-in due to which the detector fire alarm
is visible from a large distance.
The heat detection takes place by means of 4-thermistor temperature measurement system.
A fire alarm is generated when temperature limit is achieved, or in case of quick increase of
temperature. Then, it recognises the type of alarm and transmits it to the supervisory line,
and to the control unit.
Characteristics of the heat detector:
•Sensitivity degree and the temperature class
comply with EN 54.
•Regulation of alarm threshold which compensates
the influence of the environment
•Indication of an alarm by means of the LED diode
•Additional LED diodes for the testing state
•External status indicator
•Integrated short-circuit isolator
•A casing with a low profile
•Operation in the addressable systems
Dimensions (mm):
TECHNICAL DATA
110
Name
Heat detector class
Heat detection
A1R
Overload, differential
Supply voltage
24V DC
Current during supervision
<160 μA
Current during alarming
Working temperature
Tightness protection level
Acceptable relative humidity
Visual signalling
51
Heat detector with the visual
signalling device TF
Dimensions
<2 mA
from -25°C to 55°C
IP 20
95% at 35°C without condensation
Green LED diode, red FLASH LED diode
Ø110 x 51 mm
Weight
200 g
Detector colour
White
Product code
FSD0000004
110
TF detector operation mode
15
Fire Alarm System
Fire detectors
Heat and smoke detector with the visual
signalling device TSF
The heat and smoke detector is intended for detecting fires in their early phase. The detector
has two sensors: heat and smoke. The application of two types of a sensor allows to detect all
types of fires quickly and with certainty. The two-sensor detector operates within the AWEX
fire alarm system. The element can be installed on the loop addressable supervisory lines and
on the side addressable line. Additionally, the detector has the flashing visual signalling device
built-in due to which the detector fire alarm is visible from a large distance.
The two-sensor smoke and heat detector is equipped with two sensors for fire detection. The
smoke detection takes place in a detection chamber equipped with photoelectric diodes. Smoke
goes to the chamber during fire. The particles of smoke reflect the light emitted by light emitting
diodes which causes that an IR diode receives the signal and transmits it to a microprocessor.
The heat detection takes place by means of
4-thermistor temperature measurement system. A fire
alarm is generated when temperature limit is achieved,
or in case of quick increase of temperature. Then, it
recognises the type of alarm and transmits it to the
supervisory line, and to the control unit.przekazuje go do
mikroprocesora.
Characteristics of the heat and smoke detector:
110
Dimensions (mm):
•Sensitivity degree and the temperature class
comply with EN 54.
•Recognition of the state of soiling
•Regulation of alarm threshold which compensates
the influence of the environment
•Indication of an alarm by means of the LED diode
•Additional LED diodes for the testing state
•External status indicator
•Integrated short-circuit isolator
•A casing with a low profile
•Operation in the addressable systems
TECHNICAL DATA
Name
Heat detector class
Smoke detection
Heat detection
24V DC
<160 μA
51
Working temperature
Acceptable relative humidity
Visual signalling
16
Overload, differential,
Current during supervision
Tightness protection level
TSF detector operation mode
A1R
Optical, scattering,
Supply voltage
Current during alarming
110
Heat and smoke detector with the visual signalling device TSF
Dimensions
<2 mA
from -25°C to 55°C
IP 20
95% at the temp. of 35°C without condensation
green LED diode, red FLASH LED diode
Ø110 x 51 mm
Weight
200 g
Detector colour
White
Product code
Usefulness for test fires
detecting
FSD0000004
According to 54-7
Fire Alarm System
Fire detectors
TECHNICAL DATA
Detector name
T
Heat detector class
Heat detection
TS
TF
A1R
A1R
A1R
A1R
Overload,
differential
Overload,
differential
Overload,
differential
Overload,
differential
Smoke detection
S
Optical,
scattering
Optical,
scattering
Supply voltage
SF
TSF
Optical,
scattering
Optical,
scattering
24V DC
Current during supervision
<160 μA
<160 μA
<160 μA
<160 μA
<160 μA
<160 μA
Current during alarming
<450 μA
<550 μA
<550 μA
2mA
2mA
2mA
Working temperature
from -25°C to 55°C
Tightness protection level
IP 20
Acceptable relative humidity
95% at the temperature of 35°C without condensation
Visual signalling
LED Diode, red, green
Dimensions
Green LED diode, red FLASH LED diode
Ø110 x 51 mm
Weight
200 g
Detector colour
white
According to
EN 54-7
(TF2, TF3, TF4,
TF5)
Unfulness for test fires detecting
Heat measurement system
4-thermistor
Product code
FSD0000001
FSD0000002
According to
EN 54-7
(TF2, TF3, TF4,
TF5)
According to
EN 54-7
(TF2, TF3, TF4,
TF5)
4-thermistor
4-thermistor
FSD0000003
FSD0000004
According to
EN 54-7
(TF2, TF3, TF4,
TF5)
4-thermistor
FSD0000005
FSD0000006
51
110
Dimensions (mm):
110
17
Fire Alarm System
MANUAL CALL POINTS
MANUAL CALL POINT ROP 21
The manual call point ROP 21 is intended for passing on information about a fire to the fire
alarm control unit by a person who saw the fire and has manually activated it. The device can
operate on the supervised lines and loops controlled by the FAS fire alarm control unit only.
The element is equipped with a ratchet which allows to restore the supervision state again
without the need to replace any elements. The element has a double-sided short-circuit isolator.
Characteristics of the manual call point:
•Double-sided short-circuit isolator built-in
•The manual call point type A
•Supervision state possible to be restored
•Operation in the addressable systems
•Signalling diode
•Applicable inside buildings
Dimensions (mm):
TECHNICAL DATA
Name
Supply voltage
<130 μA
Alarming current
<500 μA
IP 21
Working temperatures
-10 °C to 55°C
ROP dimensions together with the casing
Weight
Type of activationn
Casing colour
Does it contain a short-circuit isolator?
86
Product Code
18
Internal
Casing protection level
Acceptable relative humidity
45
24V DC
Supervision current
Environmental category
86
Manual call point ROP 21
95% at 40°C
86 x 86 x 45 mm
150 g
A
RAL 3001
YES
FSR0000001
Fire Alarm System
MANUAL CALL POINTS
MANUAL CALL POINT ROP 65
The manual call point ROP 65 is intended for passing on information about a fire to the fire
alarm control unit by a person who saw the fire and has manually activated it. The device can
operate on the supervised lines and loops controlled by the FAS fire alarm control unit only.
The element is activated by breaking a glass. When the call point is activated, it is necessary to
replace the glass for a new one. The element has a double-sided short-circuit isolator.
Characteristics of the manual call point:
•Double-sided short-circuit isolator built-in
•The A type call point
•Supervision state possible to be restored
through replacement of the glass
•Operation in the addressable systems
•Signalling diode
•Application inside and outside buildings
Dimensions (mm):
TECHNICAL DATA
Name
Supply voltage
Supervision current
Alarming current
Environmental category
24V DC
<130 μA
<500 μA
Internal/External
Casing protection level
IP 65
Working temperatures
-25°C to 70°C
Acceptable relative humidity
ROP dimensions together with the casing
Weight
115
Manual call point ROP 65
Type of starting
Casing colour
Does it contain a short-circuit isolator?
300 g
A
RAL 3001
YES
FSR0000002
115
Product code
95% at 40°C
115 x 115 x 60 mm
60
19
Fire Alarm System
INPUT/OUTPUT MODULES
INPUT/OUTPUT MODULE MIO 22, MIO 44, MIO 88
57
114
116
150
67
77
The MIO module is the input/output device intended for the co-operation between fire-fighting
devices and the AWEX fire alarm system. It is intended for the operation on the supervision,
addressable, loop, and side lines. The device can cooperate with acoustic signalling devices,
emergency exit doors, smoke venting systems, CO2 automatic extinguishing systems, and
other devices intended for the fire protection. The MIO modules are equipped with 2, 4, or 8
relay outputs, and 2, 4, or 8 inputs without supervised potentials, depending on their version.
The element has integrated short-circuit isolator which allows quickly location of fault and
appropriate operation of the loop line, even in the event of its fault.
190
150
114
TECHNICAL DATA
Input/output module name
Casing type
MIO 22
MIO 44
T
N
N
Supply voltage
2
4
Inputs number
2
4
Input function
Yes
Input initiation
Parametrising through resistance (22 kΩ)
IP 66
IP 67
IP 66
IP 67
IP 66
IP 67
114 x 114 x 57 mm
118 x 118 x 67 mm
150 x 116 x 67 mm
187 x 118 x 67 mm
190 x 150 x 77 mm
187 x 118 x 67 mm
Weight
20
8
Active, Inactive, Short-Circuit, Interval
Input control
Product code
8
Relay output (NO/NC/COM).
AC contact load capacity: 2A 250 V 60 W
DC contact load capacity: 2A 220 V 60 W
Relaying control outputs
Working temperature
N
Built-in, double-sided
Outputs number
Dimensions
T
24V DC
Short-circuit isolator
Casing tightness
MIO 88
T
200 g
280 g
480 g
Od -25°C do 70°C
Od -25°C do 70°C
Od -25°C do 70°C
FSM0000001
FSM0000004
FSM0000002
FSM0000005
FSM0000003
FSM0000006
Fire Alarm System
SIGNALLING DEVICES
STATUS INDICATOR WZ 4
The WZ 4 status indicator is intended for optical repetition of the signalling alarming state of
the detector or a group of detectors in the fire alarm systems. It can be added to the detector
or a group of detectors. The indicator is applied when installed detector is invisible or there is
limited access to a room supervised by detectors, for example, it is installed in spaces above
ceiling, in cable passages, technical rooms, hotel rooms, etc.
Characteristics:
•Additional visual signalling
•Small dimensions
•4 LED signalling diodes
•Consumption of current <4mA
Dimensions (mm):
TECHNICAL DATA
Name
Supply voltage
Status indicator WZ 4
16 – 30 VDC
Consumption of current during
0 mA
Consumption of current during alarming
<4 mA
Dimensions
Weight
18 g
FSS0000001
44
Product code
Ø44 x 23 mm
23
21
Fire Alarm System
Accessories
NAME
PHOTO
TECHNICAL DRAWING
PRODUC CODE
110
Detector Base
FSD0000007
119,5
18
DUST COVER
FSD0000008
30
124
MIO TESTING
MODULE
66
70
41
FSM0000004
PANE GLASS FOR ROP 65
FSR0000003
2
38
70
KEY FOR ROP 21
4,8
17
115
Signalling device
SA-K5N
FSR0000004
FSS0000002
115
62
Signalling device
SA-K7N
FSS0000003
100
22
Fire Alarm System
NOTes
We inform that AWEX company cares about its constant development and improvement of its products, according
to the latest technological trends. We reserve the right to introduce changes in the design and technical data of our
products without prior notice. Data included in this publication are intended for informational purposes only, and
cannot be the ground of legal claims.
Dystrybutor
AWEX SP. Z O. O. SPÓŁKA KOMANDYTOWA
Masłomiąca, ul. Długa 39
32-091 Michałowice, Poland
tel.: (+48) 12 681 55 00, fax: (+48) 12 681 55 26
e-mail: export@awex.eu
www.awex.eu