Model #: SU2200RTXL2UA - Appliances Connection
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SU2200RTXL2UA
SmartOnline 2.2kVA On-Line Double-Conversion UPS, 2U Rack/Tower, 110/120V NEMA outlets
Highlights
2200VA / 2.2kVA / 1600 watt on-line double-conversion 2U rack/tower UPS
110/120V +/-2% output at 50/60Hz, high efficiency economy mode option
Expandable runtime, Hot-swap batteries; 19 in / 48.3cm installed depth
USB, RS232 & EPO ports; support for SNMP/WEB card options
Front panel status LEDs with detailed load and battery metering
2 independently switchable output load banks
NEMA 5-20P input; L5-20R & 5-15/20R outlets
Description
2200VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an
installed depth of only 19 inches. Expandable battery runtime with optional BP48V24-2U (limit 1) and BP48V60RT-3U (multi-pack compatible)
external battery packs. Full-time sine wave 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power
Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates
continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode
saves BTU heat output and energy costs. NEMA 5-20P input plug. NEMA 5-15/20R and NEMA L5-20R output receptacles. Network-grade AC surge
and noise suppression. Zero transfer time between AC and battery operation. Network-grade AC surge and noise suppression. Zero transfer time
between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and
SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability.
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports
simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert
monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and
remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for
viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage
regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and
2POSTRMKITWM 2-post rack & wallmount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs.
Attractive all-black color scheme. $250,000connected equipment insurance;
Package Includes
SU2200RTXL2Ua On-line Double-Conversion UPS System
PowerAlert Software and cabling
Mounting hardware for 4 post rack enclosures
Instruction manual
Features
SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications
True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage
conditions
conditions
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other
UPS types
Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values
Standard internal battery set offers 14 min. runtime at half load (800W) and 4.5 min. at full load (1600W)
Automatic restart after power outages that drain batteries and shutdown UPS immediately provide AC power to equipment when power
returns
Extended runtime available with optional BP48V24-2U (limit 2 w/48VDCSPLITTER) or BP48V60RT3U (no limit) external battery packs
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 19 inches
Ships with all mounting accessories for 4 post rackmount installation
Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation
Optional 2-9USTAND accessory enables small-footprint upright tower placement
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus
any number of additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current,
battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS
nominal voltage adjustment and UPS line to battery power voltage setpoints
Built-in Emergency Power Off (EPO) interface with cable
NEMA 5-20P input plug; NEMA 5-15/20R & NEMA L5-20R output receptacles
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each
bank has 3 outlets)
Front panel LEDs offer current monitoring and battery charge level information
UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required
Single line TEL/DSL or network ethernet line surge suppression
$250,000 Ultimate Lifetime Insurance
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
2200
Output kVA capacity
(kVA)
2.2
Output Watt Capacity
(watts)
1600
Output kW capacity
1.6
Output power factor
0.7
Crest Factor
3:1
Nominal Output
Voltage(s) Supported
110V; 120V
Nominal Voltage
details
120V default
Frequency
compatibility
50 / 60 Hz
Frequency
compatibility details
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
Output voltage
regulation (line mode)
+/- 2%
Output voltage
regulation (Economy
line mode)
+/- 10%
Output voltage
regulation (Battery
mode)
+/- 2%
Built-in UPS output
receptacles
6 5-15/20R outlet(s); 1 L5-20R outlet(s)
Built-in controllable
switched load banks
Two switchable three-outlet 5-15/20R load banks
Basic PDU options
PDUNV (1U / 2 C19, 12 C13 outlets); PDU1420T (0U / 14 5-15/20R outlets); PDU40TDUAL (0U / 40 5-15/20R
outlets)
Metered PDU options
PDUMH20 (1U / 13 5-15/20R outlets); PDUMH20AT (1U / 16 5-15/20R outlets)*; PDUMV20 (0U / 16 5-15/20R
outlets); PDUMV40 (0U / 32 5-15/20R outlets)
Switched PDU options
PDUMH20ATNET (1U / 16 5-15/20R outlets)*; PDUMV20NET (0U / 24 5-15/20R outlets)
External PDU
redundancy options
*ATS switch options PDUMH20AT & PDUMH20ATNET support dual UPS and hot-swappable UPS configurations
Output AC waveform
(AC mode)
Sine wave
Output AC waveform
(battery mode)
Pure Sine wave
INPUT
Rated input current
(at maximum load)
16A
Nominal Input
Voltage(s) Supported
110V AC; 120V AC
UPS input connection
type
5-20P
Input circuit breaker
30A
UPS Input cord
length (ft.)
10
UPS Input cord
length (m)
3
UPS input cord
length details (m)
Built-in
Recommended
Electrical Service
20A 120V
BATTERY
Full load runtime
(minutes)
4.5 min. (1600w)
Half load runtime
(minutes)
14 min. (800w)
Expandable battery
runtime
Extended runtime supported via optional external battery packs
External battery pack
compatibility
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible)
Expandable runtime
description
BP48V24-2U (limit 2 w/ 48VDCSPLITTER)
DC system voltage
(VDC)
48
Battery recharge rate
(included batteries)
Less than 6 hours from 10% to 80%
Replacement battery
cartridge (internal
UPS battery
replacement)
RBC94-2U
Battery Access
Front panel battery access door
Battery replacement
description
Hot-swappable, user replaceable sealed, flame retardant, non-spillable batteries
VOLTAGE REGULATION
Voltage regulation
description
Online, double-conversion power conditioning
Overvoltage
correction
2% output voltage regulation during overvoltages to 150
Undervoltage
correction
2% output voltage regulation during undervoltages to 80
Severe undervoltage
correction
2% output voltage regulation during undervoltages to 65 (under 70% load only)
LEDS ALARMS & SWITCHES
LED Indicators
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery
and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in
rack/tower formats
Alarms
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Alarm cancel
operation
Power-fail alarm can be silenced using alarm-cancel switch
Switches
2 switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
570
UPS AC suppression
response time
Instantaneous
UPS Dataline
suppression
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form
factors supported
with included
accessories
4 post 19 inch rackmount (mounting rail kit included)
Installation form
factors supported
with optional
accessories
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary form factor
Rackmount
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / inches)
3.5 x 17.5 x 19
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / cm)
8.9 x 44.4 x 48.3
Installed whole
system total rack
space height (rack
spaces)
2U
Secondary form factor
Tower (requires 2-9USTAND)
Installed whole
system dimensions in
secondary form factor
(height x width x
depth / inches)
17.5 x 3.5 x 19
UPS dimensions in
secondary form factor
(height x width x
depth / cm)
44.4 x 8.9 x 48.3
UPS / Power Module
weight (lbs)
47.4
UPS / Power Module
weight (kg)
21.5
UPS Shipping
dimensions (height x
width x depth / inches)
9.8 x 20.2 x 24
UPS Shipping
dimensions (height x
width x depth / cm)
24.8 x 51.4 x 61
Shipping weight (lbs)
57.3
Shipping weight (kg)
26
UPS housing material
Steel
Cooling method
Fan
Installed whole
system dimensions in
secondary form factor
(height x width x
depth / cm)
44.4 x 8.9 x 48.3
ENVIRONMENTAL
Operating
Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature
Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr.
(full load)
812.9
AC economy mode
BTU / hr. (full load)
347.2
Battery mode BTU /
hr. (full load)
885.6
AC economy mode
efficiency rating
(100% load)
94%
Audible Noise
< 45dB at 1m
COMMUNICATIONS
Communications
interface
USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring
port description
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure
communications
PowerAlert software
Included
Communications
cable
USB and DB9 cabling included
WatchDog
compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
No transfer time (0 ms.) in online, double-conversion mode
Low voltage transfer
to battery power
(setpoint)
80V (100% load), 65V (
High voltage transfer
to battery power
(setpoint)
150
SPECIAL FEATURES
Cold Start (startup in
battery mode during
a power failure)
Cold-start operation supported
High availability UPS
features
Automatic inverter bypass; Hot swappable batteries
Green & high
efficiency features
High efficiency economy mode operation; Individually controllable load banks; Schedulable daily hours of economy
mode operation
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty
Period (Worldwide)
2-year limited warranty
Connected
Equipment Insurance
(U.S., Canada &
Puerto Rico)
$250,000 Ultimate Lifetime Insurance
Related Items
Optional Products
Related Model
Description
Qty.
SNMPWEBCARD
For remote monitoring and control via SNMP, Web, or Telnet.
1
ENVIROSENSE
Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD
or switched PDU.)
1
RELAYIOCARD
Programmable Relay I/O Card
1
MODBUSCARD
For remote monitoring and control via MODBUS protocol
1
AS400CABLE KIT
Power Management Tools - UPS Communication Cable Kit for System i / AS400 /
iSeries Servers
1
2-9USTAND
Enables Tower Placement of Rackmount UPS Systems
1
2POSTRMKITWM
Enables 2-Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems
1
BP48V24-2U
BP48V242U - External Battery Pack for UPS System
1
BP48V60RT-3U
External Battery Pack and Cable. 3U, Expandable, Blue 2-Point Connector
1
WEXT3-2200-3000
3-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack
models, 2200-3000VA
1
WEXT5-2200-3000
5-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack
models, 2200-3000VA or less
1
PDUB20
Dual source Power Distribution Unit / PDU with Manual Transfer Switch enables
Hot-swappable UPS Replacement in Critical Network Applications
1
PDU1220
Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical
networking equipment
1
PDUV20
Safe, reliable power distribution for critical networking equipment
1
PDUNV
Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical
networking equipment
1
PDUMH20
Metered PDU / Power Distribution Unit- Safe, reliable power distribution with digital
current meter
1
PDUMV20
Metered PDU / Power Distribution Unit - Safe, reliable power distribution with digital
current meter
1
PDUMH20AT
Metered PDU with ATS - Power Distribution Unit with dual-input Auto Transfer Switching
1
PDUMNH20
Monitored PDU / Power Distribution Unit supports real-time remote monitoring of load
level, voltage and frequency with options for remote environmental and security
monitoring
1
PDUMNV20
Monitored PDU / Power Distribution Unit supports real-time remote monitoring of load
level, voltage and frequency with options for remote environmental and security
monitoring
1
PDUMH20ATNET
Switched, Metered PDU with ATS - Power Distribution Unit with dual-input Auto Transfer
Switching, individual outlet control and SNMP network interface
1
PDUMV20NET
Switched, Metered PDU with Remote Monitoring - 0U Vertical Rackmount Power
Distribution Unit for Networks with Individually Switchable Outlets, Current Metering,
Remote Monitoring and Control
1
P044-06I
6-inch 12AWG Heavy Duty Power Adapter cord
(NEMA-L5-20R to NEMA-5-20P)
1
P049-010
10-ft. 12AWG Heavy Duty Power cord
(IEC-320-C19 to NEMA 5-20P)
1
P007-006
6-ft. Heavy-Duty 14AWG Power cord
(IEC-320-C13 to NEMA 5-15P)
1
P007-010
10-ft. Heavy-Duty 14AWG Power cord
(IEC-320-C13 to NEMA 5-15P)
1
More information, including related products, owner's manuals, and additional technical specifications, can be found online at
www.tripplite.com/en/products/model.cfm?variables.txtModelID=2950.
Copyright © 2012 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous
improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising