DCN Analog Audio I/O Module

DCN Analog Audio I/O Module
DCN Analog Audio I/O Module
Security Systems
Instructions for Use
en LBB 3513/00
DCN Analog Audio Input/Output Module | LBB 3513/00 |
Table of Contents
1.
2.
2.1
2.2
2.3
3.
4.
4.1
4.2
4.3
5.
5.1
5.2
5.3
6.
Introduction . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting the Analog Audio Input/Output
Module to the DCN system . . . . . . . . . . . . .
Initializing the Module . . . . . . . . . . . . . . . .
Connecting Audio Inputs and Outputs . . . . .
Controls and Indicators Analog Audio . . . . .
Application Examples . . . . . . . . . . . . . . . . .
Remote Interpretation . . . . . . . . . . . . . . . . .
Music Distribution . . . . . . . . . . . . . . . . . . . .
Distribution of other DCN system audio . . .
Connectors . . . . . . . . . . . . . . . . . . . . . . . . .
25-pole Sub-D connector . . . . . . . . . . . . . . .
3-pole XLR connector (Input/Output) . . . . .
6-pole DIN connector (DCN) . . . . . . . . . . .
Electrical data and requirements . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.4
.4
.
.5
.7
.7
.9
.10
.11
.12
.13
.14
.14
.14
.14
.16
Conventions used in this document
NOTE:
Notes draw attention to special instructions tips
or other useful information
Digital Congress Network
Installation and Operating Manual
DCN
Software
Manuals
Reference
Refer to the DCN Installation &
Operating Manual Chapter x
page xx
Reference
Refer to the relevant DCN Software
Manuals
BOSCH
Installation
The ‘screwdriver’ symbol describes the Installation
requirements. If installation is identical to that stated in the ‘DCN Installation and Operating
Manual’ the text ‘See Installation and Operating
Manual will be stated.
BOSCH Security System | April 03 | 3922 988 92512 en
en | 3
en | 4
DCN Analog Audio Input/Output Module | LBB 3513/00 |
1.
Introduction
The Analog Audio Input/Output Module type LBB
3513/00 has been designed for use in the BOSCH
Digital Congress Network (DCN) system. The module is
used to connect external analog audio equipment for distribution through one of the DCN audio distribution
channels. The module also provides monitoring facilities for the distributed audio channels as well as facilities
for coupling to external audio reproduction systems and
audio recording equipment.
1
LBB 3513 audio 1/0
Input
Remote
Push
2
2
1
3
6
Output
3
1
2
3
The module is ideally suited for the following applications:
●
Audio/music input for distribution via DCNs
language channels.
●
Distribution of one of DCNs distribution channels to
a PA system, monitoring or recording facilities.
●
Connecting an interpreter at a remote site via standard communication links e.g. telephone line.
●
Connecting to a remote DCN system.
For Application details see Chapter 4.
1
4
2
6
3
5 4
Trunk
1
5
The module includes a remote control facility for custom
built panel solutions where channel selection and various
signal indications are available on a 25-pole SUB-D connector (fig.1 (6)). For connection details see Chapter 5.
BOSCH
Figure 1 - Rear view LBB 3513/00
Key to symbols (Figure 1)
Securing screws for 19” rack frame assembly
3-pole XLR INPUT connection (female)
3-pole XLR OUTPUT connection (male)
6-pole DIN connector (female) for loop-through
to other DCN system units.
320 mm long cable terminated with a 6-pole
DIN connector (male 240°) for
connection to the DCN system trunk-line.
25-pole Sub-D connector (male) with locking
facility for custom built remote channel selection including remote indicators and remote
blocking of audio signals.
2. Installation
The Analog Audio Input/Output Module LBB 3513/00
is a standard Eurocard assembly (100 x 220 mm) intended for mounting in a 19” Eurocard rack mounting frame
assembly with a height of 3HU (5.25”) (See Figure 2).
The maximum number of modules housed in a frame
assembly is limited to 8 and the maximum number of
modules used in a single DCN system is limited to 30.
The module includes two standard rack mounting
screws (Fig.1(1)) for securing into the rear of the frame
assembly. Standard 19” rack mounting procedures
should be used when installing the module.
NOTE:
The module once installed in a DCN system is
powered via the DCN power supply devices and
therefore requires no external power supply.
BOSCH Security System | April 03 | 3922 988 92512 en
en | 5
DCN Analog Audio Input/Output Module | LBB 3513/00 |
LBB 3513 audio 1/0
LBB 3513 audio 1/0
Input
Remote
Push
LBB 3513 audio 1/0
Input
Remote
LBB 3513 audio 1/0
Input
Remote
Push
Push
LBB 3513 audio 1/0
Input
Remote
Push
LBB 3513 audio 1/0
Input
Remote
LBB 3513 audio 1/0
Input
Push
Remote
Push
LBB 3513 audio 1/0
Input
Remote
Input
Remote
Push
Push
LBB 3513 audio 1/0
Input
Remote
Output
Output
Output
Output
Output
Output
Output
Push
Output
Output
Trunk
Trunk
Trunk
Trunk
Trunk
Trunk
Trunk
Trunk
Trunk
Figure 2 - Rear view LBB 3513/00
2.1 Connecting the Analog Audio Input/Output Module to the DCN System
The Analog Audio Input/Output Module LBB 3513/00 provides connectors for loop through connection of one
module to the other (i.e daisy chain, Fig.1 (4) and (5)). Figures 3 and 4 show the connection method used. For further information refer to Chapter 3 of the DCN Installation & Operating Manual.
NOTE:
The Power Consumption Factor (PCF value) of an Analog Audio Input/Output Module is limited to 1 PCF.
To DCN LBB 3513
trunk-line
or
DCN unit
LBB 3513 audio 1/0
LBB 3513
1
LBB 3513 audio 1/0
Input
Remote
Push
LBB 3513
2
LBB 3513 audio 1/0
Input
Remote
Remote
Push
Push
Output
Output
Output
Trunk
Trunk
Trunk
Trunk-line
(loop-through)
Trunk-line
(loop-through)
Figure 3 - Connection between analog I/O modules
BOSCH Security System | April 03 | 3922 988 92512 en
3
Input
From next
module or DCN
unit
Trunk-line
(loop-through)
en | 6
DCN Analog Audio Input/Output Module | LBB 3513/00 |
Central Control Unit LBB 3500/xx
LBB 3500/10 /30
Line
Rec.
Test
Digital Congress Network
Installation and Operating Manual
Trunk
In
In
Out
Out
115 V-T4A 230 V -T2A
Symmetrical
Extension cable
LBB 3516/xx
DCN Trunk-line
DCN Trunk-line
LBB 3513
1
LBB 3513
2
LBB 3513 audio 1/0
LBB 3513 audio 1/0
Input
Remote
Refer to Chapter 3
Installation Techniques
Max.30 modules per
DCN system
Input
Remote
Push
Output
Push
Output
From next module
or DCN unit
Trunk
Trunk
Figure 4 - Connection between analog I/O modules to the DCN system
19" Rack frame assembly
LBB 3513 audio 1/0
LBB 3513 audio 1/0
Input
Remote
To DCN
trunk-line
or
DCN unit
Push
LBB 3513 audio 1/0
Input
Remote
Push
LBB 3513 audio 1/0
Input
Remote
Push
LBB 3513 audio 1/0
Input
Remote
Push
LBB 3513 audio 1/0
Input
Remote
Push
LBB 3513 audio 1/0
Input
Remote
Push
LBB 3513 audio 1/0
Input
Remote
Push
Input
Remote
Push
Output
Output
Output
Output
Output
Output
Output
Output
Trunk
Trunk
Trunk
Trunk
Trunk
Trunk
Trunk
Trunk
DCN Trunk-line (loop-through)
Digital Congress Network
Installation and Operating Manual
Refer to Chapter 3
Installation Techniques
From next DCN unit
Figure 5 - Connection of modules in rack frame assemble (rear view)
BOSCH Security System | April 03 | 3922 988 92512 en
en | 7
DCN Analog Audio Input/Output Module | LBB 3513/00 |
2.2 Initializing the Module
Before the Analog Audio Input/Output Module can be
used in a DCN system, the module must first be initialized for recognition by DCNs Central Control Unit
(CCU). This is given in the form of an address allocated
to the module by the CCU. An ‘Init/de-Init’ push-button switch (Fig. 7 (12)) with LED indication (red) ((Fig. 7
(10)) located on the modules PCB is used for this procedure.
To initialize a module proceed as follows:
A module not initialized is identified when all its LEDs
are ON. To initialize a unit proceed as follows:
1. Press the units init/de-init switch (Fig.7(12)).
2. All LEDs indicate their normal status, the ini
tialization LED (Fig.7(10) must be OFF.
3. To de-initialize a unit momentarily press the init/deinit switch again. All LEDs are ON.
2.3
Connecting Audio Inputs and Outputs
INPUTS (refer to Figure 6.)
The Analog Audio Input/Output Module has a single 3pole XLR connector (female) (Fig. 1(2)) for the connection of a symmetrical analog audio line input with an
optional input transformer for galvanic separation (type
TR/BV3) (see Fig.7 for location details). An asymmetrical connection is also possible. Each module can handle
one external audio input. This input is selected via a 16channel select switch (0 - 15) located at the front of the
module (Fig.7 (5)). An audio limiter circuit with
ON/OFF switch (Fig.7(1)) and LED indication (Fig. 7
(2)) is available to optimize the channel signal level
input for the best result. The limiter circuit is only active
when the LED is ON.
In applications for remote interpretation (see Chapter 4)
several Analog Audio Input/Output Modules can be set
to the same input channel. However, the audio signal to
the connected interpreter desks and language channel
selectors depends on the selected interlock settings of the
interpreter desks and the level of each channel..
NOTES:
1. For each external audio signal a single Analog
Audio Input/Output Module is required.
2. Use of the audio input muting facility is
required when more than one (max.6) ’
Analog Audio Input/Output Module’ is used
for input to the same language channel (see
section 5 about remote control). The microphone interlock settings for the interpreter
desks, determine which interpreter desk or
‘Analog Audio Input/Output Module’ may be
active.
BOSCH Security System | April 03 | 3922 988 92512 en
OUTPUTS
Refer to Figure 6.
The Analog Audio Input/Output Module has a single 3pole XLR connector (male) (Fig. 1(3)) for the connection
of external audio distribution systems -such as a P.A. system with recording and monitoring facilities. Each mod
ule can handle one external audio output.
This output is selected via a 16-channel select switch (0 15) located at the front of the module (Fig.7 (3)).
The output is a symmetrical analog audio line output
(via the modules output transformer) of one of the
selected DCN language distribution channels.
Asymmetrical connection is also possible.
NOTE:
The Analog Audio Input/Output Module has the
same functionality as one output of the DCN
Audio Media Interface Unit type LBB 3508/00
which offers 4 outputs each having 15 channels
selected via a 15-position rotary selector switch.
Intercom channels CANNOT be used for
distribution.
GENERAL
For symmetrical and asymmetrical input and output connections refer to Chapter 5.
en| 8
DCN Analog Audio Input/Output Module | LBB 3513/00 |
Remote site
(Interpreter)
Audio/
Music
Other
DCN system
Telecom
line
Audio Input
External analog audio sources for
distribution through DCN interpretation
channels (selectable via input rotary switch
(1 - 15)
LBB 3513/00
LBB 3513 audio 1/0
Input
Remote
Push
Output
1 Input per module
Input
1 output per module
Output
Audio Output
Analog audio output of one of
the selected DCN distribution
channels (selectable via output
rotary switch (0 - 15)
DCN system
Trunk
DCN system
Recording/
Monitoring
PA
System
DCN System
See section
5.1
Remote Control
(custom built
control panel)
(not supplied)
Telecom
line
Remote Interpreter
Floor or language channel
Figure 6 Analog audio input/output module (Inputs and outputs)
BOSCH Security System | April 03 | 3922 988 92512 en
en | 9
DCN Analog Audio Input/Output Module | LBB 3513/00 |
3.
Controls and Indicators
Figure 7 shows the layout of the Analog Audio
Input/Output Module PCB and its controls and indicators.
Key to symbols (Figure 7)
Limiter ON/OFF switch (selection of correct
max. channel signal level input)
Limiter ON/OFF LED (yellow)
Rotary switch (audio output channel selection 0
-15) (distribution)
Assigned LED (red) Module active at selected
audio down-link channel (output)
Rotary switch (audio input channel selection 0 15) (contribution)
Assigned LED (red) Module active at selected
audio up-link channel (input)
Engaged LED (yellow) Selected audio up-link
channel engaged
Error indication LED (red) (indicates fault situation)
Remote control LED (yellow) (Off - local control,
On - Remote control)
Initialisation LED (red) (Off module initialized,
On module not initialized)
Power ON LED (green)
Module Initialization/De-initialization switch
(Init/de-init)
25-pole connector for ribbon cable of remote
connector
Location for optional input transformer type
Beyer TR/BV3
3-pole XLR INPUT connection (female)
3-pole XLR OUTPUT connection (male)
6-pole DIN connector (female) for loop-through
to other DCN system units.
6-pole DIN connector (male)
Solder connections 6-pole DIN connector
12
11
10
9
8
7
6
13
14
D1
D2
D3
D4
SW1
15
D5
D6
SW2
5
4
16
D7
SW3
3
17
2
D8
A
B
C
D
E
F
SW4
1
19
18
BOSCH
Figure 7 PCB Layout - LBB 3513/00
BOSCH Security System | April 03 | 3922 988 92512 en
en | 10
DCN Analog Audio Input/Output Module | LBB 3513/00 |
4.
4.1
Applications
Remote Interpretation
Remote Interpretation using Telephone Coupler
Figure 8 shows a basic application for Remote
Interpretation using a telephone coupler.
Using a single Analog Audio Input/Output Module an
interpreter located at a remote site can be connected via
a telephone line (POTS (Plain Old Telephone System) or
ISDN) for two-way audio to a DCN system. Input
channel assignment is done at the Analog Audio
Input/Output Module or remotely by the operator. The
floor signal or a language channel is selected as the output channel to the interpreter.
IMPORTANT:
In applications using a telephone coupler, it is important
to use only telephone couplers which DO NOT feedback their input signal to their output signal. Therefore,
telephone coupler type LBD 4503/03 is not recommended in the applications described.
NOTES using Audio Communication only
1. Application with Audio Communication only
requires an Analog Audio Input/Output
Module LBB 3513/00 and a telephone coupler
capable of full duplex communication via
POTS or ISDN at the DCN system site. A
dialling facility is also required either as part
of the telephone coupler or using a separate
telephone. Use of ISDN in Audio communication applications is highly recommended.
2. The limiter of the Analog Audio Input/Output
Module shall be in the OFF position.
3. For audio level matching an attenuator may
be required, the value of which depends on
the type of telephone coupler being used.
DCN System site
Remote Interpreter site
Telephone
Coupler
LBB 3513/00
DCN System
with
Interpretation
DCN
Cabling
Line-OUT
Attenutator
-12dB
Line-IN
Telephone
Headset
Line-IN
Line-OUT
Telephone
Handset
POTS or ISDN (preferred) full duplex
communication required
Telephone
Handset
(when required)
Figure 8 Application for remote interpretation with telephone coupler (Basis)
BOSCH Security System | April 03 | 3922 988 92512 en
en | 11
DCN Analog Audio Input/Output Module | LBB 3513/00 |
At the remote interpreter site, headphones and a microphone or headset are connected to the CODEC of a
video conferencing system for use by the interpreter.
Remote Interpretation with Video Conferencing
Figure 9 shows a typical application for Remote
Interpretation with video conferencing.
At the DCN System site one Analog Audio
Input/Output Module LBB 3513/00 is used for each
remote interpreter. Each Analog Audio Input/Output
Module LBB 3513/00 is connected to the CODEC of a
video conferencing system located at the DCN system
site, coupled via ISDN lines to the CODEC of a video
conferencing system located at the site of the remote
interpreter. In the application shown in Figure 9, 3
ISDN lines (preferred) are used giving optimal performance and quality, however 2 ISDN lines or even 1
ISDN line can also be used depending on customer
application requirements.
NOTES using Video conferencing
1.
The CODEC of a Video conferencing system
shall have facilities for adjustment of the input
and output audio levels at both the DCN system
site and the site of the remote interpreter as well
as being able to mute the microphone at the site
of the remote interpreter.
2.
The limiter of the Analog Audio Input/Output
Module LBB 3513/00 must be OFF.
3.
For optimal results ensure the echo cancellation
function of the CODEC video conferencing system is OFF.
4.
Attenuation of the output level of the Analog
Audio Input/Output Module LBB 3513/00 to
the CODEC video conferencing system is prob-
Remote Interpreter
DCN System site
Video Conference System
(CODEC)
LBB 3513/00
DCN System
with
Interpretation
DCN
Line-OUT
Cabling
CONTROL
Attenutator
-12dB
Audio
Line-IN
External
Microphone
or
Headset
Speaker/
Headphone
Audio
Line-OUT
Line-IN
Video Conference System
(CODEC)
REMOTE
Optional
(non-standard device)
ENC.
ISDN
RS 232
DEC.
DCN Camera System
Video-OUT
ISDN
1- 3
ISDN
lines
RS 232
Optional
Video-IN
Including
Remote Control Device
Video-OUT
VIDEO
MONITOR
ENC.
VIDEO OUT
VIDEO
MONITOR
DEC.
Selectors and
Indicators
(incoming channel
selection etc..)
Custom Built equipment
Figure 9 Application for remote interpretation with video conferencing
A monitor or TV-set is used at both the DCN system
site and the site of the remote interpreter. At both sites a
video conferencing set-up menu is included for dialling,
and setting-up the video and audio requirements e.g. at
DCN system site: video sent to remote interpreter or
video of the remote interpreter, at Remote Interpreter
site: display of own video and video of speaking delegate via DCN controlled cameras.
BOSCH Security System | April 03 | 3922 988 92512 en
5.
6.
ably required (i.e. 12 dB attenuator depending
on the type of video conferencing system)
Delay of received remote language channel with
respect to DCN output to remote interpreter of
several hundred milliseconds (actual value system dependent)
Simultaneous transmission of Analog Audio
Input/Output Module data is in most systems
possible via one or more available RS-232 data
ports.
en | 12
DCN Analog Audio Input/Output Module | LBB 3513/00 |
7.
Functions for selection of incoming languages
via a remote selector, remote status indicators
for channel assignment, error and engaged indication, analog input/output audio muting etc.
can be made available to the remote interpreter
through project solutions. Project solutions
require dedicated hardware for control (selectors, LED indicators etc.) and coding/decoding
at both sites into and from an RS-232 serial bit
stream. At the DCN system site all connections
are made to the Analog Audio Input/Output
Module LBB 3513/00. For functionality refer to
Section 5.1.
4.2 Music Distribution
Figure 10 shows a typical application for music distribution. Refer also to Fig. 6.
The DCN system can be used partly or fully for the distribution of mono music channels. Listening to the distributed music is through DCNs language channel selectors type
LBB 3524/xx and LBB 3526/xx or through IR receivers
using the Infrared language distribution system.
The number of channels available depends on the type
of Central Control Unit (CCU) and whether the unit is
used in a stand-alone or PC controlled system. The
maximum number of channels available is as follows:
NOTE:
For more information and support the BOSCH
Security Systems Customer Service and Technical
Support group can be contacted through your
local BOSCH sales organization.
●
●
●
11 in a stand-alone system using CCU type
LBB 3500/00
15 in a PC controlled system using CCU type
LBB 3500/10.
11 in a Multi-CCU system using CCU type
LBB 3500/30.
NOTE:
For more information and support the BOSCH
Security Systems Customer Service and Technical
Support Group can be contacted through your
local BOSCH sales organization.
DCN System site
DCN System
with
Interpretation
LBB 3513/00
LBB 3513/00
LBB 3500/xx
DCN Trunk cable
DCN Trunk cable
Line-OUT
Line-IN
LBB 3513/00
Line-OUT
Line-OUT
1
2
Line-IN
n
Line-IN
DCN Trunk cable
Personal
Computer
(optional)
Input 1
CCU LBB 3500/00: max. 11 channels
CCU LBB 3500/10: max. 15 channels
1
DCN
equipment
(if used)
Input 2
2
n
Language channel selectors LBB 3524/xx, LBB 3526/xx
and/or IR Language Distribution System (LDS)
Figure 10 Application for music distribution
BOSCH Security System | April 03 | 3922 988 92512 en
Input n
en | 13
DCN Analog Audio Input/Output Module | LBB 3513/00 |
4.3
The audio from the other DCN system (DCN system
(site 2)) can be taken from the outputs of one or more
Audio Media Interface Units LBB 3508/00 as required.
The maximum number of inputs is as follows:
Distribution of other DCN system audio
Figure 11 shows a typical application for the distribution
of audio signals from another DCN system (DCN
System site 2).
●
Audio signals from another DCN system such as language channels and floor audio can be inserted into a
DCN system for distribution via the language channels.
This application is ideally suited when 2 systems have to
be coupled for occasional listening to the same interpretations.
●
max. 11 for stand-alone and Multi-CCU systems
max. 15 for PC controlled systems
NOTE:
For more information and support the BOSCH
Security Systems Customer Service and
Technical Support Group can be contacted
through your local BOSCH sales organization.
DCN System (site 1)
LBB 3513/00
LBB 3500/xx
DCN System
with
Interpretation
Line-OUT
DCN trunk cabling
Line-IN
LBB 3513/00
LBB 3513/00
Line-OUT
1
Line-OUT
2
Line-IN
n
Line-IN
LBB 3500/00: max. 11 channels
LBB 3500/10: max. 15 channels
Input 1
LDS
Language Distribution
System
(wired + Infrared (IR))
Input 2
Digital Congress Network
Installation and Operating Manual
Audio output
Input n
Refer to Chapters
2 and 3
Bosch
Security Systems
Audio Media
Interface Unit
LBB 3508/00
DCN System (site 2)
Figure 11 Application for distribution of other DCN system audio
BOSCH Security System | April 03 | 3922 988 92512 en
DCN System
with
Interpretation
DCN Trunk cabling
DCN Analog Audio Input/Output Module | LBB 3513/00 |
5.
en | 14
Connectors
5.1 25-pole Sub-D connector (REMOTE)
Refer to Fig. 1(6) and Fig. 12
Pinning
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
+5V
Remote
Engaged LED
Ground
Audio output channel (bit 4)
Audio output channel (bit 2)
Audio output channel (bit 0)
Mute audio input switch
Audio input channel (bit 3)
Audio input channel (bit 1)
Reserved for future use
Limiter switch
Error LED
Ground
Audio input LED
Audio output LED
Mute audio output switch
Audio output channel (bit 3)
Audio output channel (bit 1)
Ground
Audio input channel (bit 4)
Audio input channel (bit 2)
Audio input channel (bit 0)
Limiter LED
Reserved for future use
(limited)
(active low)
(reserved)
(LSB)
(active low)
(active low)
(active low)
(reserved)
(LSB)
5.2 3-Pole XLR Connector (INPUT/OUTPUT)
Refer to Fig. 1 (2) (3)
Symmetrical
Pinning
1
2
3
Asymmetrical
Description
Ground
+ signal
- signal
Between Pin 1 (ground) and pin 2 (+signal) or 1 Ground Pin 3 (- signal)
The output level is 6 dB lower than for a symmetrical output connection.
The input level remains at -3 dB (limiter OFF), -24dB (limiter ON).
5.3 6-Pole DIN connector (DCN)
Refer to Fig, 1 (4) (5) and DCN Installation & Operating Manual
BOSCH Security System | April 03 | 3922 988 92512 en
en | 15
DCN Analog Audio Input/Output Module | LBB 3513/00 |
OUTPUT CHANNEL
SELECTOR
X6
SUBD25
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
0
MUTE INPUT SWITCH
+5V
4
3
2
1
MUTE OUTPUT SWITCH
F
+5V
8
4
2
1
6 5 7
AUD_IN_LED
ENGAGAGED_LED
AUD_OUT_LED
MUTE_OUTPUT OUT4
OUT3
OUT2
OUT1
OUT0
INPUT CHANNEL
SELECTOR
MUTE_INPUT IN4
IN3
IN2
IN1
IN0
0
4
3
2
1
F
8
4
2
1
6 5 7
LIMIT_LED
LIMIT_SWITCHTEST
ERROR
LIMITER SWITCH
5 1 2 3 4
RED
ERROR
YELLOW
LIMITER
RED
AUDIO OUTPUT
YELLOW
ENGAGED
RED
AUDIO INPUT
NOTE:
According to the above diagram, when connecting remote selectors for input and output channel
selection and limiter switch, the on-board switches are disabled. However both the on-board LEDs and
the remote panel LEDs will be active.
Figure 12 - Proposal for remote control panel LBB 3513/00
BOSCH Security System | April 03 | 3922 988 92512 en
en | 16
DCN Analog Audio Input/Output Module | LBB 3513/00 |
6.
-
Electrical data and requirements
Supply voltage
Current consumption (approx.)
Audio input impedance (symmetrical)
Audio input attenuation (blocked)
Nominal audio input level (limiter off)
Nominal audio input level (limiter on)
Maximum audio input level
Audio output impedance (symmetrical)
Audio output attenuation (blocked)
Nominal audio output level (-9 dBFS)
Maximum audio output level (0 dBFS)
Maximum cable length for remote control
Current consumption for LEDs connected to
the Remote control
- Frequency response
:
:
:
:
:
:
:
:
:
:
:
:
17 - 40 V
40 mA at 40 V, 50 mA at 17 V
>10 kOhm (no transformer)
>80 dB at 1 kHz
-3dBV
-24 dBV
6 dBV
<600 Ohm at 1 kHz
> 80 dB at 1 kHz
1 dBV
10 dBV (22 dBV for PA-channel)
25 m
:
:
5 mA
equal to transmission link freq. response of DCN
system
BOSCH Security System | April 03 | 3922 988 92512 en
DCN Analog Audio Input/Output Module | LBB 3513/00 |
BOSCH Security System | April 03 | 3922 988 92512 en
en | 17
For more information please visit www.boschsecuritysystems.com
© 2003 Bosch Security Systems B.V.
Data subject to change without notice
April 03 | 3922 988 92512 en
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project