01. VS375CVS400CVS575CVS600C - OPTI
Value Series
For personal computers and SOHO
VS375C/ VS400C/ VS575C/ VS600C
* 3 UPS outlets + 3 surge protected outlets
* Integrated protection for telephone / modem / LAN card
* Cold start capability
* 1050 Joules surge energy rating
* RS232 communication port
* Easy battery replacement
* 4 hours recharge time
* Smart power management software
* Auto restart & self-diagnostics
* VS375C
* VS400C
VS575C
VS600C
The VSC Series UPS are perfect for your personal and small office computers. They protect systems against
blackouts, sags, and surges. The smallest and lightest in its class, this high frequency and high efficiency UPS
provides complete protection for a workstation and its peripherals.
Specifications
Model Name
Topology
On-battery Output Waveform
Maximum Capacity (VA/W)
INPUT
Nominal Input Voltage
Nominal Input Frequency
Input Voltage Range
Input Protection
OUTPUT
Nominal Output Voltage
Output Voltage Regulation
Transfer Time (Typical)
Start on Battery
Auto Restart
Number of Outlets
PROTECTION
Data line Surge Protection
Surge Energy Rating
Normal Mode Noise Suppression
BATTERY
User Replaceable Batteries
Typical Backup Time**
Recharge Time to 90% (Typical)
COMMUNICATIONS INTERFACE
Communication Port***
ADVANCE WARNING / DIAGNOSTICS
Front Panel
Audible Alarms
ENVIRONMENTAL
Operation Temperature
Audible Noise
PHYSICAL
Dimensions (Physical/Packing)
(in)
(L×W×H)
(mm)
Weight (Net/Gross)
(lbs)
(kg)
CONFORMANCE
Approvals
Font Panel
VS375C / VS400C
VS575C / VS600C
Standby
Simulated Sine Wave
375VA / 225W
575VA / 345W
VS375C/ VS575C
1
100/110/120Vac or 220/230/240Vac*
50Hz / 60Hz Auto Sensing
Rated Voltage +/- 20%
Fuse
100/110/120Vac or 220/230/240Vac*
Rated Voltage +/- 5% (on battery)
4 ms
Yes
Yes
3 Battery Backup+3 Surge Protection (US)
3 Battery Backup+3 Surge Protection (IEC)
1
2
3
4
< 4 Hours
ON/OFF, Test/Silence
AC Mode
Battery Mode
Battery Fault
Rear Panel
RJ11 / RJ45
1050 Joules
Full time EMI/RFI filtering
12V / 3Ah × 1
7~12 min
2
3
4
1
2
12V / 3.8Ah × 1
10~15 min
4
3
5
RS232
100V
110V
120V
Power Status /AC Mode / Battery Mode / Battery Fault / Overload
Battery Mode / Battery Low / Battery Fault / Overload
1
0~40°C / 32~104°F
< 40 dBA
2
7.9×3×6.9 / 9.6×5×9.8
200×77×175 / 248×127×250
5.1 / 6.4
5.3 / 6.6
2.3 / 2.9
2.4 / 3.0
4
3
5
220V
230V
240V
UL / cUL(1X0V) ; CE , C-Tick , A-Tick , GOST-R(2X0V)
CS 73 0B
Specifications are subject to change without notices.
* Models of these nominal voltages are available, however each model is present to certain nominal voltage, which is not
user-changeable.
** Typical backup time represents backup time for load equivalent to one PC and one 15" LCD monitor. Values here are
for reference only.
*** You can purchase RS232 to USB cable.
Backup Time (Typical)
Simulated
Sine Wave
1
2
3
4
5
RJ45/ RJ11
AC Input
RS232
Bypass
UPS Outlet
VS375C / VS400C 7~12 mins
VS575C / VS600C 10~15 mins
1.
Standby UPS
Series
Line Interactive
UPS Series
On-Line UPS
Series
Stabilizer
Series
Inverter Series
Surge Series
Power Storage
Series