CERTIFIKAT Mall

CERTIFIKAT Mall
EU-type Examination Certificate
0402 – MID – 459701
Issued to
Teltek i Örebro AB Argongatan 83, 703 74 Örebro, Sweden.
In respect of (type of instrument)
An electronic automatic checkweigher and/or weigh price labeller. The weighing instrument
may be of either single or multi-interval type.
In accordance with
The Measuring Instruments Regulations STAFS 2016:1 and The Regulations and Guidelines
concerning automatic weighing instruments STAFS 2006:7, implementing in the NB’s country
law the Directive 2014/32/EU of 26 February 2014 on measuring instruments (MID).
Applicable essential requirements of directive 2014/32/EU
- Annex I, Essential requirements
- Annex VIII (MI-006), Automatic weighing instruments
Harmonised standards and normative documents used
Applicable parts of the following normative documents referred to in the Official Journal of the
European Union 2006/C 269/01, OIML R51, edition 2006, Automatic catchweighing
instruments.
Further applied documents
- WELMEC 2.6, Guide for the testing of automatic catchweighing instruments (Issue 3)
- WELMEC 7.2, Software Guide (Issue 1)
- WELMEC 8.16-1 Issue 2
Rated operating conditions
Measurand:
weight of discrete load of packages
Mechanic environment class:
NA
Accuracy class:
XIII(1), Y(a)
Electromagnetic environment class: E1 or E2
Measurement range:
15-60000 g
Climatic environment:
+5 to +40°C
Miscellaneous
Valid until December 15, 2026. This certificate replaces earlier issues. The certificate was
originally issued 15th December 2006.
The principal characteristics, approval conditions are set out in the appendix hereto, which forms part of the
approval documents and consists of 4 pages. All the plans, schematic diagrams and documentations are recorded
under reference files P604914, P502257, P802327, PX14451 and PX22438.
2016-12-15
SP Technical Research Institute of Sweden
Certification - Notified Body No. 0402
Lennart Aronsson
Bengt Gutfelt
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 1.
EU-type Examination Certificate
Appendix
The instruments / measuring systems must correspond with the following specifications:
1
Design of the instrument
1.1
Construction
The instrument is designed to weigh prepackages dynamically. It comprises a self-indicating
and price computing weighing machine with associated label printer and mechanical handling
facilities.
Via the infeed conveyor the product to be weighed is transported to the weighing unit. The
product is, after the weighing, transported via the outfeed conveyor either to the labeller or to
the sorting device. Infeed and outfeed conveyors are optional.
Operating modes: weigh price labeller, checkweigher or both.
1.2
Class
Measurand sensor
Load cell
C3
C6
C6
C3
C3
C3
C3
C3
Huntleigh 1015
Huntleigh 1130
Huntleigh 1130
Huntleigh 1130
Huntleigh 1130
Flintec PCB
Flintec PCB
Flintec PCB
Capacity
(kg)
e (g)
≥
5
7
20
7
20
50
100
250
0.1
0.2/0.5
0.5/1.0
0.5/1.0
1.0/2.0
1.0/2.0
2.0/5.0
5.0/10.0
Min (g)
≥
15
20
35
20
35
125
350
1750
Max (g)
≤
600
1200/3000
3000/6000
1500/3000
3000/6000
6000/12000
12000/30000
30000/60000
1.3 Measurand processing
Hardware
The weighing instrument consists of a load cell, conveyor system, display and control unit. A
photocell is placed immediately before the weighing conveyor.
Software
The validation of software was based on the essential requirements given in MID and WELMEC
Guide 7.2. A report with number P502257A-01, dated 2006-11-15 was issued and is held by
SP.
Software version
The following program versions are approved:
Type of program
Program version
Measuring module HM91
1.0
Checksum
51345
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 2.
EU-type Examination Certificate
Appendix
1.4
Indication of the measurement results
To the control unit it is possible to use different displays and interfaces.
Type
Display/Interface
C20
LED display
C60
TFT display
C80
Windows embedded PC
All members of the Teltek Cxx family share the same design and software. The control unit
consists of a digital data processing unit.
1.5
Optional equipment and functions subject to MID requirements
- Initial zero setting
- Automatic zero setting
- Semi automatic zero setting, static mode only
- Automatic zero tracking, static mode only
- Preset tare
- Dynamic setting function, only adjustable during set up
- Belt speed setting
- The type C80 consists of a presentation computer which is connected to 1-4 weighing units.
There are three models:
1:
Single model
One presentation computer connected with up to 4 weighing units weighing separately.
Function
At the bottom of the menu (see picture 1) one of the weighing units (or all four) are
selected.
After choosing for example weighing unit 1, data for this unit will be presented on the screen
as seen below in picture 1.
Picture 1A Menu single model with weighing unit number one selected.
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 3.
EU-type Examination Certificate
Appendix
Picture 1B Menu single model with all weighing unit number selected.
2:
Dual to Single model
One presentation computer connected to 2 weighing units. In the article register you can
select if the presented weight is summarized from both weighing units (single mode selected,
see picture 2A) or weights from both weighing units shown (dual mode selected, see picture
2B).
Picture 2B Arrangement of weighing units
for dual to single model with dual mode selected.
Picture 2A Arrangement of weighing units
for dual to single model with single mode
selected.
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 4.
EU-type Examination Certificate
Appendix
3:
DualWeigher model
One presentation computer connected to 2 weighing units. In the article register you can
select if load are to be weighed on weighing unit 1 or 2.
Picture 3 Arrangement of weighing units for dualweigher mode.
1.6
Technical documentation
The operating manual includes technical specifications and for example how to get access to
the checksum. Dynamic settings are protected by a password not available to the user.
1.7
Integrated equipment and functions not subject to MID
See operating manual
2
Technical data
2.1
Rated operating conditions
Measurand
Solid packages within the measuring range, weight expressed in g.
Measurement range
Maximum capacity,
Minimum capacity,
Verification scale interval, class XIII(1)
Number of verification scale intervals, class XIII(1)
Verification scale interval, class Y(a)
Number of verification scale intervals, class Y(a),
Maximum belt speed,
Max ≤ 60 000 g
Min ≥15 g
e ≥ 0,1 g
n ≤ 6000
e≥1g
n ≤ 3000
≤ 75 m/min
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 5.
EU-type Examination Certificate
Appendix
Accuracy class
XIII(1), Y(a)
Environments / influence quantities
Climatic:
+5 to +40°C
Mechanic:
NA
Electromagnetic:
class E1, E2
2.2
Other operating conditions
Not applicable.
3
Interfaces and compatibility conditions
The instrument may use the following protective interfaces for data communication:
- centronics parallel
- RS232
- RS485
- current loop, 20 mA (can bus, profibus)
- ethernet
- USB
4
Requirements on production, putting into use and utilisation
4.1
Requirements on production
No special requirements identified.
4.2
Requirements on putting into use
In order to perform the verification in another location then the place of use the instrument
must be equipped with infeed conveyor and spirit level.
4.3
Requirements for consistent utilisations
No special requirements identified.
5
Control of the measuring tasks of the instrument in use
5.1
Documentation of the procedure
No special measuring tasks are identified.
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 6.
EU-type Examination Certificate
Appendix
6
Security measures
6.1
Sealing
Interfaces
No sealing of interfaces is necessary.
Indicator
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 7.
EU-type Examination Certificate
Appendix
On the control board (measurement computer) the dipswitch, S2, shall be sealed with a
control mark preventing switching of the button.
The checksum shall be checked and noted.
Load cell
The screws (lower) that are locking the load cell to the load receptor shall be sealed either with
control marks or with wire, see Picture 4.
S2/OM1
Picture 4. Sealing of load cell screws, C80 and an example for placement off dipswitch, S2
Descriptive plate
The descriptive plate shall be sealed with control marks.
6.2
Data logger
There is no mandatory requirement to have a data storage device.
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 8.
EU-type Examination Certificate
Appendix
7
Labelling and inscriptions
7.1
Information to be borne by the instrument
The marking on the instrument shall contain the following information:
The descriptive plate mounted on the instrument shall contain the following information:
- name or identification mark of the manufacturer
- serial number and type designation
- number of certificate
- accuracy class
- verification scale interval, e for each weighing unit
- checksum
- maximum rate of operation for each connected weighing unit
- maximum conveyor speed for each connected weighing unit
- maximum capacity, Max for each connected weighing unit
- minimum capacity, Min for each connected weighing unit
- maximum preset tare, PT
- temperature range
- electrical supply
7.2
Conformity marking in accordance to MID article 17
The instrument shall be marked in accordance to MID article 17 which e.g. describes the CEmarking together with M, year of marking and the notified body number.
7.3
Further inscriptions, if necessary
No further inscriptions considered necessary.
Certificate 0402 – MID – 459701, issue 6, dated 2016-12-15
SP Technical Research Institute of Sweden
Box 857, SE-501 15 Borås, Sweden
Phone: +46 10-516 50 00
E-mail: info@sp.se / www.sp.se
This certificate may not be reproduced other than in full, except with the prior
written approval by SP. SPs Certification Rule SPCR 302 has been applied.
The certificate, including appendices consists of 9 pages where this is page 9.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF