PCSAS620-112 WorkSight System

PCSAS620-112 WorkSight System
PCSAS620-112 WorkSight® System
10335 W Emerald St
Boise, ID 83704
Phone 1.208.323.1000
QUICK INSTALLATION GUIDE
1
Before You Start
Contents:
WS6220 Sensor (1)
Sensor Mounting Hardware: 4 each - 1 1/4” x 10-24 Bolts,
Locking Hex Nuts, and Flat Washers
PVP760 Camera System (1)
(1) PVP710 Monitor
(1) CPK732 Camera / Cable
(1)CPC700 Camera
(1) DDC023C Cable
Mounting Hardware, (2) Monitor brackets, (1) Camera bracket, (4)
Trigger Wires, power adapter, and sun shield (not shown)
SAS Alarm (1) 87-112dB Alarm (Safety Alert System)
Cables (2)
WSAS INT Cable 4’/1.2M (1)
WS610PT Transition Cable 30’ / 9.1M (1)
SAS Connector Kit
(1) each DT06-4S connector and W4S lock wedge
(3) 0462-201-16141 Deutsch pins, (1) 114017 sealing plug
User Manuals and Drill Template
2
Mount Sensor
Select a location for the sensor approximately 3ft/1M from the ground.
Ideally the sensor should be centered on the rear of the vehicle. The
sensor face should be perpendicular to the ground with the ‘PreView’
graphic oriented as shown in install diagram.
Important!
Before the PreView Sensor is permanently installed to the vehicle,
verify the selected location provides a clear detection zone.
Temporarily attach the sensor in the proposed location, apply power to
the system, and verify nothing is detected.
Mounting
Using the drill template, scribe position marks through the holes and
drill 1/4” (6mm) holes centered at the marks. A 1 1/2” diameter
clearance hole is required for the sensor connector and the mating cable.
Secure the sensor to the vehicle with the supplied hardware. Apply a
maximum of 22 in-lbs to secure the sensor.
DOC. # 3700162B
3
Vehicle shown for reference
Mount / Install Alarm
SAS—Safety Alert System. Remove existing back up alarm and
mount the SAS Alarm in the same location or in close proximity.
Connect SAS INT cable to alarm, power, and to WS610T.
4
Powered by
5
5
Install WS610T / Camera Cables
2
Routing the cables should start at the back of the vehicle and end in
the cab. Allow a small service loop in the cable at the sensor or
camera and secure the cable every few feet (~1M) with tie wraps. To
enter the cab, drill a 1” (24mm) hole and feed the cables through.
Route the remaining length of cable to the Monitor. Install SAS
connector kit to WS610PT, detailed below .
4
Note orientation:
THIS SIDE UP
Critical Note!
The sensor mating connector is fully waterproof if mated
properly. The connectors with a collar (coupling ring)
must be turned to the right until they lock with the
mating connector. The connectors with a latch(es) must
click (locking mating connectors together). Do not route
cable next to heat sources or area that may see abrasion or
rock and debris damage. Bundle and store any excess
cable.
White = Pin 3
Black = Pin 2
5
2
PVP710
WS6220
4
WS610PT
3
CPC700
SAS ALARM
WSAS-INT
DDC023C
Red = Pin 1
Wire Connections
Wiring Diagram
Sealing Plug = Pin 4
Install terminals on the 3 wires, install pins and sealing
plug in the connector, and add lock wedge. Use
appropriate Deutsch crimp tool set for 18awg wires.
5
Back Page
WS610PT
Mount Monitor and Camera
Contact Technical Support with Questions:
Mount the monitor in a location easily viewed by the driver. Use
supplied hardware. Wiring detailed on the back of this document.
Telephone: 844.787.2327
Web: www.PreViewRadar.com
Email: support@preco.com
Mount the camera on the rear of the vehicle to achieve the best
possible view of the area. Use the supplied hardware.
The quick install guide is only a supplement to the product manuals. Please read all of the
manuals for complete information and instructions before installing the product.
1
3
PCSAS620-112 WorkSight® System
10335 W Emerald St
Boise, ID 83704
Phone 1.208.323.1000
QUICK INSTALLATION GUIDE
Initial System Power Up and Test
The PreView® system is a blind spot collision warning system
designed to supplement other safety practices and/or devices. The
machine operator is always the first line of defense when safely
operating a vehicle.
Vehicle shown for reference
Once the sensor, camera system, and SAS alarm are installed, wired and connected, power
should be applied to test system operation. The monitor should power up and display the
camera view. The vehicle must be placed in reverse to power up the sensor. The SAS
alarm should also begin sounding and should either change tone (SAS97DT) or increase in
volume (SAS) with the detection of an object. Any detection will be indicated on the
monitor, check for any objects that may be detected by the sensor. If possible, move the
sensor so it does not detect the object(s). If it is not possible to relocate the sensors
contact Preco Electronics, Inc™.
If for some reason the system is malfunctioning, the
will change to a yellow
triangle indicating a failure. Refer to the Troubleshooting section in the monitor manual to
determine the error and potential causes.
Once the system has been installed and verified, the detection zone should be tested. The
test should be performed with two people, one who remains in the cab (the operator), and
one who walks through the sensor field to the rear of the vehicle (the assistant). The
operator engages the parking brake, presses the vehicle brake, and places the vehicle in
reverse. The assistant then walks through the detection zone while the operator notes
where the monitor displays a detection. An accurate detection zone can be mapped by
moving about the rear of the vehicle and noting when the monitor displays a detection. The
assistant could also map the detection area instead of the operator by noting where the alarm
either changes tone (SAS97DT) or increases in volume (SAS). NOTE: Assistant should
TESTING / MAINTENANCE
Test the PreView® Radar System every day for functionality and performance
prior to vehicle operation, refer to the sensor manual.
Caution: The tilt angle of the sensors will determine
the detection zone of the radar.
Connect Monitor CAM 1
Connector to reverse
PVP710
WS610PT
wear hearing protection to prevent hearing damage as the SAS alarm is very
loud.
APPROXIMATE
PATTERN SHOWN
FOR 20’ SENSOR
MONITOR OVERLAY GRAPHICS
SENSOR POWER
SAS Connector Kit
installed on WS610T
detailed on front page
Connect DC Power to Monitor
DC connector, and red/black
wires to ignition and ground
WSAS-INT
DETECTING OBJECT(S)
Red +, Black -, To
existing Back-Up
Alarm Circuit (Power)
CPC700
DDC023C
DOC. # 3700162B
WS6220
Connect Cable to CAM 1
Connector on Monitor
NO SENSOR COMMUNICATION
Reference Monitor Manual
for additional information
Powered by
DETECTION AREA
NOT TO SCALE
2
SAS ALARM
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising