Slim DMX Wall Washer

Slim DMX Wall Washer
/17 Wall Washer
 Product Name
Wall Washer
(single color and R/G/B)
 Item No.
5023, 5024, 5025, 5026
 Product Introduction
A. We use high power 2W LED as the light source, R/G/B type can bring excellent light effects and
brilliant colors.
B. There are two parts for the wall washer, first part is light body and the other one includes power
supply and controller box, which makes this wall washer different with other wall washers.
C. It has smaller weight and stable quality and it is easy for maintance. Wall washers can be
connected by 3-pin cable hand in hand, so very easy for installation.
D. There are 14 kinds of build-in programs which can be operated at the DMX windown. This wall
washer can also be controlled by outside DMX 512 controller or super DMX Console to achieve more
different lighting effects.
 Application
It can be widely used for all kinds of wall lighting decoration, as well as in stage, meeting room,
ancient building crowd, and civilization plaza etc.
 Technique Parameter:
Wall washer
Item
Part No.
5023
5024
5025
R/G/B (2w)
5026
Single color 2W LED
LED Source
12pcs
24 pcs
12 pcs
Lens angle
50 degree
Input Voltage
AC100~240V,50~60Hz
Max Power
23.6W
Control Way
Weight ( net weight)
46W
24W
24 pcs
45.4W
Build-in Control mode, Control box,
2.3kg
3.5kg
2.3kg
3.5kg
 Working temperature
Environment temperature
-20℃ ~ +45℃
IP Rank
IP65
 Connection Ports
One power supply input terminal,
3-pin male connector
One power supply output terminal,
3-pin female connector
One standard DMX signal input terminal,
3-pin male connector
One standard DMX signal input terminal,
3-pin female connector
One 4-wire and 3-loop signal input terminal, 4-pin female connector ( connected with body of
light )
 Function for Buttons of DMX Windown under wall washer.
R/G/B wall washer has 14 kinds of working mode, which can be operated by pressing the two
buttons. Once is for increas and the other is for decrease.
 Instruction for the numbers in the DMX window.
001-512, slave mode. Under this mode, the light is operated by mater controller. (DMX 512
controller, SD card DMX controller or DMX Super console can work as the master controller)
H-1~H-d: master mode. Once the light is under this mode, all the other lights connected will follow
with this light.
 Mode Instruction:
001~512:DMX Address
H-1:Static Red
H-2:Static Green
H-3:Static Blue
H-4:Static Yellow
H-5:Static Cyan
H-6:Static Purple
H-7:Static White
H-8:7 colors jumping, red, green, blue, yellow, cyan, purple, white
H-9:3 colors jumping, red, green, blue
H-A:7 colors gradually changing, red, green, blue, yellow, cyan, purple, white
H-b:3 colors gradually changing, red, green, blue,
H-C:7 colors flashing, red, green, blue, yellow, cyan, purple, white
H-d:3 colors gradually changing, red, green, blue
 Outline Dimensional Drawing
" L" is the total length of item, 0.5m Slim wall washer: L=507mm, 1m Slim wall washer: L=993mm
107.5
70.8
34.6
66
L
373
60W DMX controller
45.6
 The Connection method
Method one:
Controller
3-pin connector
DMX signal connect each other
NO.1
NO.2
waterproof tail
NO.n
Signal
distributor
AC100~240V
high voltage connect each other
3-pin connector
DMX signal connect each other
3-pin connector
NO.1
AC100~240V
DMX signal connect each other
3-pin connector
NO.1
Signal
distributor
NO.n
high voltage connect each other
3-pin connector
AC100~240V
waterproof tail
NO.2
3-pin connector
NO.2
high voltage connect each other
waterproof tail
NO.n
Method two:
Controller
DMX signal connect each other
3-pin connector
NO.1
NO.2
NO.n
high voltage connect each other
3-pin connector
waterproof tail
AC100~240V
Signal
distributor
NO.1
AC100~240V
Signal
distributor
DMX signal connect each other
3-pin connector
3-pin connector
NO.n
high voltage connect each other
waterproof tail
DMX signal connect each other
3-pin connector
AC100~240V
NO.2
NO.1
3-pin connector
NO.2
NO.n
high voltage connect each other
waterproof tail
Data of different part No. as follow (In the case of non-extending signal wire and power wire that can
bear max power)
5015
5017
40 sets
5016
5018
20 sets
 Attention:
A. Please do as the request of application instruction when the items are used.
B. Every wall washer takes up 3 DMX addresses, the address of the first wall washer plus 3 is the
address of the second wall washer.
C. If the lighting effects of a group of wall washer are the same, it means the addresses of all wall
washers in this group must be the same.
D. When setting up the address of wall washer, it should be setted from smaller number to bigger
number.
E. The max number of DMX address for the wall washers can't exceed 510.
F. There should be only one master for all wall washers connecting in one group (the master can
be a wall washer in master control mode, or a DMX controller or super DMX console)
G. When many wall washers connect together, the connection should be done according to "
product connection diagram"
H. The connection cable between two DMX controllers or between DMX controller and RGB
Amplifier can’t exceed 100m; The distance from DMX controller or Amplifier to the last wall
washer connected can’t exceed 100m.
(Indoor and outdoor use)
 Warning
1.When the product is in the packing box, please do not connect the power ;
2 Please do not connect the high-voltage power supply before installation, and make sure that the
equipment connects ground;
3.Replace any protection cover once it is broken;
4. Pay attention to keep far from fire, electricity and shake.
5. Please read the instruction carefully before installing the product , and preserve this document
for future reference.
 Installation Guide
1. The power and signal output connector of the light wall washer in one series connection should
connect with waterproof tail;
2. Please confirm that there is no short circuit between the input and output port of the general
cable. The internal components of the controller may be destroyed once connecting with
electricity when short circuit exists.
 Notes:
1. Please cut off the power before installing or demounting the light fixtures;
2. Please replace with new ones once the light body is damaged.
 Problems and solutions:
1. If the light cannot light up, please check whether it connects with power supply well and
whether the switch is on.
2. If the light turn on and off frequently, please check whether the connection between power and
lamp is fixed enough.
Note: Please contact professionals in case of above solutions do not work; please try to contact
professionals instead of open the light at once.
Pls contact manufacturer for related information like maintance or the environment request,
etc. If there is any change in the future, sorry that we will not inform.
If you have any question about the specification, please contact professionals or
manufacture.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising