Powershield SafeGuard PSG 750A
$72-00 + GST
Powershield Defender PSD1200
$160-00 + GST
Reynolds Automation Controls Pty Ltd
10 Roosevelt Street, Coburg,
VIC 3058 Australia
Phone: +61 3 9355 7422
Fax: +61 3 9355 7944
Email: info@reynolds-automation.com.au
URL: www.reynolds-automation.com.au
The
Defender
range
uses
Automatic
Voltage
Regulation (AVR) to minimise the effects of fluctuations
Defender Range
in input voltage protecting your valuable equipment
from power line disturbances.
The stylish LCD display, user replacable batteries
and six Australian sockets makes the Defender the
features
complete package at this level.
• Surge Protection, Best in its Class
applications include:
• Excellent microprocessor control guarantees high reliability
• home office equipment
• work stations
• rack equipment
• point of sale equipment
• home theatre (no fan)
• Australian outlets for UPS and Surge protection (x3)
• Australian outlets for Surge protection only (x3)
• Buck and boost AVR for voltage stabilization
• User replaceable batteries
• Silent Operation (No fans included)
• Auto restart when AC returns
• Off-mode charging
• Cold start function
• USB communication with sophisticated NetGuard® software
THE AUSTRALIAN UPS COMAPANY
www.powershield.com.au
DEFENDER LINE
PSD1600
PSD1200
Model
1200 VA / 720 W
Capacity
Topology
1600 VA / 960 W
Line Interative
INPUT
Voltage
240Vac (Nominal)
Voltage Range
177-290 Vac
50/60Hz ±5Hz (Auto sensing)
Frequency Range
OUTPUT
Output Voltage
240Vac ±10%
AC mode tracks utility. Battery Mode 50Hz ±1%
Frequency
50Hz or 60Hz ±1Hz
Frequency Range (Batt. Mode)
6ms (Typical)
Transfer Time
Simulated Sine Wave
Waveform (Batt. Mode)
Australian Outlets - UPS & Surge Protection
3
3
Australian Outlets - Surge Protection
3
3
12V* 7AH (x2)
12V*9AH (x2)
BATTERY
Battery Type & Number
6 hours recover to 90% capacity
Typical Recharge Time
4 min
13 min
Backup Time (50% Load)
PROTECTION
Overload, discharge, thermal, short circuit and overcharge protection
Full Protection
936 Joules / 19500Amps
Surge Protection
COMMUNICATIONS & MANAGEMENT
Interface
USB Interface
Software
PowerShield NetGuard® Supports Windows®, Linux, Unix, and MAC
LCD Alarm
AC Mode, Battery Mode, Low Battery (Batt. Mode), Fault, Overload
Audible Alarm
Battery Mode, Low Battery (Batt. Mode), Fault, Overload
PHYSICAL
(397 x 146 x 205)mm
Dimensions (D x W x H)
11.1kg
Net Weight
11.5kg
OPERATING ENVIRONMENT
0-40°C
Temperature
0-90% (RH Non-condensing)
Humidity
<5dB (No Fan)
Noise Level
COMPLIANCE
EN62040-1-1 2003. IEC60950-1: 2001
Safety
EMC
EN62040-2 2006
RoHS
Directive 2011/65/EU
* Product specifications are subject to change without further notice
3
1
2
6
5
4
Smart LCD
1. Input voltage
2. Output voltage
3. AC mode indicator
4. Battery mode indicator
5. Load level indicator, flashing indicates overloa
6. Battery capacity indicator, flashing indicates low battery level
PSD1200
PSD1600
www.powershield.com.au
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising