Smart SenSor - MPEC Technology Ltd

Smart SenSor - MPEC Technology Ltd
mpec
VTi21
Mounting
Flexible mounting
options and compact
size allow installation
almost anywhere.
Smart Sensor
Split Core
Split core
technology
means no need
to disconnect or
modify existing
wiring.
Indications
Sensor health and
serial data activity
at a glance.
Analogue &
Serial Ouput
Docking
Sensors
Industry standard
4-20mA output &
RailDAQ RS485 serial
interface out of the box.
Transducers can
be unclipped
from the sensor
housing and
installed up to 3m
away for ultimate
installation
flexibility.
Wide Range
Power Supply
DC power from 12V to 24V.
Differential Inputs
Programmable input sensitivity allows
detection of currents as small as 0.2 mA.
Industrial
Performance
Tested to European railway
environmental and EMC standards.
Isolated from Earth to 1kV.
Introducing the VTi21 Smart Sensor
The VTI21 has been designed for the monitoring of railway assets that require high-speed sampling and/or multiple input
channels. The VTI21 contains an on-board microprocessor that takes raw incoming waveforms and derives computed values
that are most relevant from a condition based maintenance perspective. The VTI21 can derive many output parameters from
the source waveforms and all of these parameters can be output over the RS485 data link to a connected MPEC data logger.
Master-Slave Operation:
Connect up to 7 x VTi21 per SA380TX
4-20mA Operation:
Point-to-Point Operation via Industry
Standard 4-20mA Output
mpec
AC Vane Relay
Perfect for determining the true instantaneous torque of AC vane relays, plus phase relationship,
RMS coil currents and waveform quality outputs.
EbiTrack / TI21
Monitor two track circuits, measuring quantities such as sideband ratio, average current and centre
frequency.
FS2500 / FS2600
Monitor two track circuits, measuring quantities such as sideband currents, average current inband and out-of-band RMS currents and spectral content.
High Voltage Impulse
Monitor two track circuits, measuring average current, duty cycle, frequency and pulsed power.
AC Switch Machine
General Purpose AC
Monitoring
Monitor single phase or three phase AC switch machines. The VTi21 will report waveforms for all
phases and provide direction of switch movement.
Simply monitor the AC draw of any two conductors in any circuit of interest.
part of the
group
Specifications
Ordering Information
Application
Product Code
NR Cat. No.
VT1 AC Vane Relay
VTI21-VT1
0086/036423
TI21 Track Circuit
VTI21-TI21
0086/036424
FS2500 Track Circuit
VTI21-FS25
0086/036425
FS2600 Track Ciircuit
VTI21-FS26
0086/036426
VTI21-HVI
0086/036427
AC Sensing 2.5A RMS
VTI21-ACS-001
0086/036428
AC Sensing 20A RMS
VTI21-ACS-020
0086/036429
BRK-GEN
0086/036430
HVI Track Circuit
BR930 / Q Style Bracket
Output Parameters
Application
Outputs
VT1 AC Vane
Relay
Vane Torque, Phase Angle, Local Coil Current, Control Coil Current, Chatter (Waveform
quality)
TI21 / FS2500 /
FS2600 Track
Circuit1
Center Frequency, Center Frequency Current,
Lower Side Band Current, Upper Side Band
Current, In Band Current, Spectrogram,
Loudest Frequency, Broad-Band Current.
HVI Track
Circuit1
Average Current, Positive Peak Current,
Negative Peak Current, Pulse Frequency, Total
RMS Current
AC Switch
Machine
Phase 1 RMS Current, Phase 2 RMS Current,
Virtual 3rd Phase RMS Current, Phase 1 leads
Phase 2 (True/False). Phase 2 leads Phase 1
(True/False)
Current Transducer
Model
Magnalab SCT-0400-030 (ACS-020)
Magnelab SCT-0400-001 (Other Variants)
Output
11.1 mV / A (ACS-020)
330mV / A (Other Variants)
Accuracy
<1%
Bandwidth
5 Hz to >25 kHz
Phase Error
<2 Degrees
Analogue Inputs
Bandwidth
25 kHz
Range
+/- 1.25 V Differential Input
Resolution
74 μV to 2.4 mV
(Programmable Gain)
Accuracy
<1%
Analogue Output
Bandwidth
250 Hz
Range
4-20mA Current Loop
Resolution
19.5 μA
Accuracy
<1%
Serial Ouput
Physical Layer
EIA RS485
Baud Rate
115,200 bps
Protocol Layer
MPEC RailDAQ
Note 1: 4-20mA output only available for one track circuit per VTi21.
RS485 output available for two track circuits per VTi21.
Amber Channel is available on the 4-20 mA Interface.
All listed channels available on the RS485 interface.
Contact
For further information or to find a local distributor, please
contact MPEC at the address below:
Power Supply
Voltage
12 V to 24 V DC
Power
Consumption
12V 4-20mA Mode: 0.7W
12V RS485 Mode: 0.5W
24V 4-20mA Mode: 1.1W
24V RS485 Mode: 0.8W
Environmental
mpec
part of the
Wyvern House
Railway Terrace
Derby
group
UK
DE1 2RU
Tel: +44 (0) 1332 363 979
Email: sales@mpec.co.uk
Isolation from
Earth
>1 M Ohm at 1 kV DC
EMC Certification
EN50121-4
IP Rating
4X
IK Rating
06
Temperature
Range
-25 to +85 C
Dimensions
Transducers
Docked
67 (L) x 42 (W) x 52 (H) mm
Transducer Undocked
67 (L) x 42 (W) x 23 (H) mm
Transducer
26 (L) x 26 (W) x 40 (H) mm