Owner`s Guide - Euramco Safety

Owner`s Guide - Euramco Safety
All Purpose-Battery Ventilator
®
Owner's Guide
MADE IN THE USA
Use with all
US Firefighting
literature
Euramco Group | San Diego | Luxembourg | Dubai | Ningbo
READ MANUAL BEFORE STARTING FOR THE FIRST TIME!
Thank you for purchasing the RAMFAN® EX50Li battery powered multi-purpose ventilator
manufactured in the USA by Euramco Safety, Inc.
For more than 30 years Euramco Safety has been on the cutting edge of industrial, fire,
and marine ventilation products. Each of our blower/exhausters, smoke ejectors, PPV
& LSV fans and accessories represent the finest technologies available. Every product is
constructed to demanding and exact specifications for quality, performance, and reliability.
When human life depends on having a fan that can deliver clean, safe air, you have only
one choice you can trust: RAMFAN.
Explore our website and online catalog at www.euramco.com and discover how RAMFAN
can make a difference in the field!
All product information in the publication is based on the most current information
available at the time of printing. Euramco Safety, Inc. reserves the right to make changes at
anytime without notice.
PRIOR TO FIRST USE
1. Operate on AC voltage, 85-264V, 50/60 Hz 1Φ, for charging and discharging.
2. The unit is suitable for use on Ground Fault protected circuits.
3. Should the provided AC connector be unsuitable, replace with desired connector
containing a grounding circuit. Check continuity from ground terminal to motor shell.
4. Place batteries into holders and connect to IP66 connectors, Fully charge prior to
first use.
5. This fan is for emergency service use. Charge fully between runs. Create a charging protocol.
6.
To charge, turn the speed control fully to the left (OFF) and then connect to AC outlet. Indicator lights will illuminate, and then go off. When charging commences, indicator lights will show state of charge. Charging should complete in 3-4 hours, with the
indicator lights turning green.
7. For DC operation with AC disconnected, hold the wake button until
indicator lights come on showing battery state. Advance speed control.
8. For AC operation, advance speed control.
2
CONTENTS
Warning Labels & Safety Precautions....................................................................................... 4
Specifications............................................................................................................................ 4
Control Panel............................................................................................................................ 4
Unit Description............................................................................................................................. 5
Battery Operation .................................................................................................................... 5
AC Operation ........................................................................................................................... 6
Charging ................................................................................................................................... 6
Battery ...................................................................................................................................... 7
Maintenance .................................................................................................................................. 7
3
Warning Labels & Safety Precautions
● Electrical shock hazard. Do not open enclosures.
● Operate and repair by trained
● DO NOT START with signs of visible damage.
explosive atmospheres.
personnel only.
ground AC power receptacle.
● Heat sink becomes hot during opera-
● Wear ear protection when close by.
● Keep body parts and loose objects away ● Always use grounded plug and properly ● Blower is not intended for operation in ● Do not move while running.
from intake of fan.
tion and charging. LED lights become hot during use. Do not touch.
● Use with approved, good condition LB9106
Hot Surface!
Do Not Touch Heat Sink or Lights
extension cord with ground connector.
0-150 ft (0-50m)
AWG 14 (2.50 mm)
>150 ft (> 50m)
AWG 12 (4.00 mm)
Specifications
EX50LI 18"/46 cm
Weight
45 lbs
20 kg
Dimensions
21 x 12 x 20.6 in
534 x 304 x 523 cm
Power AC
Line (85-264V 1Φ)
650w
Operating Temp
Range
-4°F to 105°F/-20°C to 40°C
Charge Temp
Range
32°F to 105°F/0°C to 40°C
20.6"
21"
"
12
Control Panel
2
4
1
4
3

Battery Wake button

LED Scene Light

Battery Indicator Lights (L&R)

Speed Control
Unit Description
The EX50Li is a multi-purpose 18"/46cm ventilator powered by battery(s) or 85-264v single
phase AC. The flexible frame configuration allows for PPV, Smoke Ejector or ducted blower
use in both normal, horizontal and hanging positions. The fan can be tilted from 0-36°
within the frame in PPV mode.
The motor, motor controller and batteries are water-resistant, IP66 rated.
The motor is a variable-speed BLDC motor controlled by a microprocessor integrated with
a power supply, dual battery chargers and an LED light driver.
The EX50Li will run with one or two 40v 6Ah Li-ion battery packs. Each pack yields about
23 min of operation at full power. Extended operation is achieved by reducing speed. The
batteries may be swapped during operation.
AC voltage can be applied while running on batteries and the ventilator will auto-switch
to AC power. Conversely, the AC power can be removed and the unit will auto-switch to
battery power, if sufficient charge remains.
The integrated battery chargers will charge one or two fully discharged battery packs in
4 hours or less.
LED scene lights are integrated into the fan shroud and have a high-low-off switch.
Hold to change.
The integrated controller is EMI-protected to prevent interference with radio
communication.
A simple Control Panel on the top of controller controls all functions.
Battery Operation
1. When AC is disconnected and Speed control is off, the controller and battery(s)
will enter a sleep mode to conserve the battery power after 60 minutes of no activity.
2. To wake, push and briefly hold Wake button on control panel. Indicator lights will show battery status. The unit will return to sleep mode if not used within 10 minutes.
3. If Speed control is not in off position, return to off, and then advance as desired.
4.
Blower will run on one or two battery packs. Two packs are used simultaneously and discharge evenly. Runtime is doubled with two packs. Indicator lights show battery charge state as in table. Indicator lights will turn red, then flash red as end of charge approaches. Batteries will disconnect at the end of their charge and blower will stop.
5. Battery(s) may be swapped for charged batteries at any time.
6. Reduce run speed to minimum required to increase runtime.
5
AC Operation
1. Connect blower to AC source.
2. Indicator lights will come on and will show battery charge.
3. Indicator lights will be solid green while running on AC, not showing battery charge.
4. When fan is stopped, indicator lights will show battery charge. The fan will begin charging after 15 min of idle time.
5. Speed control must be off or turned to off before unit will run; a safety precaution to prevent unwanted fan start.
6. Advance the Speed control as desired.
7. Batteries do not charge while fan is on.
Charging
1. If both battery(s) and AC are connected, the battery(s) will begin charging after 15
minutes of idle time.
2.
Indicator lights will show charge state during charging (See insert). Charging should complete in about 4 hours, with the Indicator lights turning green. Should the Speed control be turned on during the charge, charging will stop and the fan will start. Charging will begin again after 15 min of idle time.
3. After charging is complete, the chargers will maintain the battery(s) by keeping the blower connected to AC.
4. In service storage. Keep batteries topped by keeping blower connected to AC. Battery charge lights will go out as the controller and batteries are programmed to reduce
leakage to a bare minimum. Use wake up button to check charge state.
Indicator Lights during charge:
GREEN
6
ORANGE
FLASHING
RED
EMPTY
Green
>38v (80 - 100% charge)
Orange
>33v and 38v (20 - 80% charge)
1 sec Flashing red
>27v and 33v (20% charge)
½ sec (Quick) Flash Red
Failure to charge in 7 hrs <=36v
LIGHTS GO OFF
Low Voltage Cutout Battery <=27v
Green
>38v (80 - 100 charge)
Orange
>33v and 38v (20 - 80% charge)
1 sec Flashing red
>27v and 33v (20% charge)
½ sec (Quick) Flash Red
Failure to charge in 4 hrs <=36v
LIGHTS GO OFF
Low Voltage Cutout Battery <=27v
Battery
1. RAMFAN R2-360-AH-U lithium-ion battery packs are rated 40v 6Ah. The cells are
Samsung 18650 rated 3Ah.
2. Factors affecting Performance and Cycle life.
● Battery packs will last significantly longer when run in pairs; there will be a lower amp draw on each cell.
● The number of discharge/charge cycles depends on how far down batteries are dis
charged; called the depth of discharge (DoD). Two battery packs with an average runtime of 20 minutes (50% DoD) or less will last significantly longer than two battery packs with an average runtime of 40 minutes (100% DoD).
● As delivered, two new battery packs can power the blower for about 46 minutes. This decreases as the cycles pileup as shown in the table. Battery(s) will need to be replaced as they age.
● Keep the blower attached to AC while not being used. This will keep them charged and lengthen their service life. An idle battery will slowly lose charge and possibly become unusable.
● The number of discharge/charge cycles depends on Depth of discharge. Depth of discharge is the average capacity used per discharge. For example, 2 batteries with a 40 min capacity used for 20 minutes on average will be a 50% Depth of discharge (DoD). 1 battery with 20 min capacity run 20 minutes will be 100% DoD. The pair will last longer.
Depth of Discharge in minutes-2 packs
Discharge/Charge Cycles (Life)*
46 min.
250-500
20 min.
800+
10 min.
1500+
* Estimate only. Battery packs lose capacity as they are used. This number represents the number of cycles,
after which the battery capacity has reduced to 60-70% of starting capacity, commonly time to replace. If
battery capacity reaches less than what the user requires replace with new.
Maintenance
● DO NOT disassemble blower for maintenance reasons.
● Do not loosen screws on control box without contacting Euramco customer service. They are torqued to a setting to achieve water tightness.
● Clean fan periodically to remove accumulated dust or particles from fan guards, impeller blade and heats ink in rear of controller (ribbed). Use only biodegradable detergents. If power washing, avoid controller housing especially gaskets and control panel.
● Contact factory for replacement parts and installation instructions.
● Properly dispose of battery packs when necessary. Contact your local hazardous materials on e-waste collection department for details or proper disposal of lithium-ion batteries.
7
SM-EX50LI
032417
USA
2746 Via Orange Way
Spring Valley, CA 91978 USA
Toll Free: (800) 472-6326
Phone: +1 (619) 670-9590
Fax: +1 (619) 670-7345
theteam@euramcosafety.com
LUXEMBOURG
68, Avenue de la libérté
1931 Luxembourg
Luxembourg
Phone: +352-26008055
Fax: +352-26008056
theteam@euramcosafety.com
MIDDLE EAST – UAE
Jebel Ali FTZ
Phone: +1 (619) 670-9590 x114
Fax: +1 (619) 670-7345
theteam@euramcosafety.com
CHINA
A11, No. 1 Jinxi Road
Qingshuipu, Zhenhai, Zhejiang
Ningbo, China 315221
Phone: +86-574-87979390
Fax: +86-574-87979391
saleschina@euramcosafety.com