Product Description

Product Description
Product Description
MS3200 indicator
Page:1 of 7
Product Type:MS3200
Features:
1.
2.
3.
4.
Compact Dimensions:220×90×40
Material:Aluminum
Display options:5 digital LCD
Capacity/Division
Table 1
CAPACITY
DIVISION1
DIVISION2
DIVISION3
200kg
0.05kg
0.1kg
0.2kg
5.
6.
7.
8.
9.
Power:Rechargeable battery 6×AA / AC adapter 9V 500mA
Power saving(auto shut-off timing selectable:120seconds/180seconds/240seconds/360seconds/Off)
Operating Temperature:5~35℃
Operating Humidity:25%~95%RH
4Keys:HOLD/BMI , UNIT/WEIGHT , ZERO , TARE
HOLD/BMI
Press this key to store weight value
UNIT/WEIGHT
Toggle among KG and LB unit
ZERO
Zero the weight
TARE
Tare the weight
11.
Zero Range (4% to full capacity)
12. Tare Range (100% to full capacity)
13.
Error Message indication:
EEEEE
Ovrload
ErrL
Power on zero count too low
ErrH
Power on zero count too high
ErrE
Eeprom Error
Low battery indication
Prepared by:Lin
Data:2007-01
Version:V3.3
Product Description
MS3200 indicator
14.
15.
16.
17.
18.
19.
Page:2 of 7
Product Type:MS-3200
Two calibration weight units : kg / lb
Open calibration weight
Power on zero-setting range: + 10%
Zero range: + 4% of full capacity
Three modes : Normal mode / Setting mode /Internal Auto Calibration mode
RS232 function
Auto shut off mode
STATE
DESCRIPTION
Low battery indication
EEEEE
ErrH
Time for shut off
NOTE
30 seconds
EEPROM ERROR
30 seconds
Overload
30 seconds
Zero value higher
30 seconds
Zero value lower
30 seconds
Zero tracking
According as time of shut off
Minus weight value
Display of weighing is minus value According as time of shut off
Same weight value
Inclusion
zero
Display of weighing is Same weight
According as time of shut off tracking and minus
value
weight
Differ weight value
Display of weighing is Different
weight value
Prepared by:Lin
Data:2007-01
Inclusion
weight
No Off
Version:V3.3
minus
Product Description
MS3200 indicator
Page:3 of 7
Product Type:MS3200
KEY DESCRIPTIONS:
HOLD
BMI
UNIT
WEIGHT
ZERO
TARE
1. HOLD/BMI:
A.
B.
C.
D.
Press this key to store weight value.
To release Hold feature, Press the HOLD key again.
To release Hold feature and tare the weight, Press the TARE key.
Press and hold this key, the scale will enter to BMI setting.
2. UNIT/WEIGHT:
A. Select weigh units:kg or LB .
B. The next time of powering-on will be showed the last using weighing units.
3. ZERO:
A. When there’s load on the scale , press this key to return to zero.
B. Put a container on the scale, press this key to tare the weight, and the tarred value is stored.
4. TARE:
A. When there’s load on the scale , press this key to return to zero.
B. Put a container on the scale, press this key to tare the weight, and the tarred value is stored.
5. POWER SWITCH:
when the scale is used or not used ,please turn the power on or the power off.
Prepared by:Lin
Data:2007-01
Version:V3.3
Product Description
MS3200 indicator
Page:4 of 7
Product Type:MS3200
Function table:
Press and hold [ HOLD/BMI] to turn the power, and then press continuously [UNIT/WEIGHT] three times, the
display will show the “SET”.
Prepared by:Lin
Data:2007-01
Version:V3.3
Product Description
MS3200 indicator
Page:5 of 7
Product Type:MS3200
THE MEANING OF FUNCTION SETTING
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
AOFF:
Unit:
CAP:
divS:
CAL:
trAn:
t.b.r.:
Grav.:
trd.:
BMI:
Time for auto off (120s / 180s / 240s /360s / off)
Weight units (kg / lb)
Capacity (1 ~ 9999kg )
Division (0.001 ~ 5kg)
Calibration weight (1 ~ 9999kg )
RS232 Transfer
RS232 Transfer band rate
Gravity
Transfer mode
WEIGHT/H2 ( ON/OFF)
Table2—Calibration Weight
1. Press and hold [ZERO] to turn the power on, and then press continuously [UNIT/WEIGHT] three times, the
display will show the “CALukg”.(press [UNIT/WEIGHT] key to selected the calibration unit)
2. Press [ZERO] key, when the display will show AD value, press [ZERO] key, the display will show “SAVE”
and then show calibration weight.
3. Press [ZERO] key again, the display will show “SAVE” and then return to AD value. Now calibration weight is
complete.
BMI function setting
1.
2.
3.
4.
5.
Body on the pan, it should your weght: 80kg
When the display stable, press HOLD to keep the display 80kg
Press and hold the HOLD key, until it display HLT 100, it means to input your height in cm
Press HOLD and UNIT keys until the display 180, it means 180cm
Press TARE, it display 80kg and 25%.
Prepared by:Lin
Data:2007-01
Version:V3.3
Product Description
MS3200 indicator
Page:6 of 7
Product Type:MS3200
RS232 TRANSMIT FUNCTION
1.
2.
3.
4.
5.
When the function trAn set ON,The RS232 is actived
Baud rate is selected 4800 or 9600 when the function t.b.r. set 4800 or 9600 。
RS232 Transmission Agreement:
Mode:Simplex Asynchronous Serial
Baud rate:4800 or 9600
Data Bit:8
Parity Bit:NONE
Stop Bit:1
Data Format:ASCII
Transmission Information Format: 16 Byte ,blank=20H
<STX><Status><+/-><D><D><D><D><D><D><D><U><U><U><U><U><ETX>
Transmission Information Format show:
STX: Start of Transmission=02H
Status:Status bit
Example:*=(2AH)=Stable weight, ~=(7EH)=Unstable Weight
+/-: +=(2BH)=Positive Weight , -=(2Dh)=Negat Weight
DDDDDDD: Value of Weight , 7 ASCII Code
UUUUU: 4 ASCII Code Weight Units: kg or LB
ETX: Stop of Transmission =03H
SETTING THE ACCELERATION TO GRAVITY MODE
1. Press [TARE] and [UNITS] first, then press [ON/OFF], while keeping [TARE] and [UNITS]pressed, the
display will show “SEt”, then press the [UNITS] several times until the display show ”GrAv” press [TARE]
the display show “on” press the [HOLD] the display show “OFF” .When the display show “ON” means
acceleration to gravity is actived. When the display show “OFF” means acceleration to gravity is inactived.
2. When acceleration to gravity is actived press [ON/OFF] turn the power off, then press [ON/OFF] turn the
power on, then press [UNITS] key 3 seconds enter to acceleration to gravity mode .1). when the display
show “C9.○ 00” ( ○ for flash digit ) first setting the local gravity.2). press [TARE] key again, rightward
flash digit, 3).press [ HOLD ] key, increase digit input the gravity value, press [UNITS] the display enter to
another local acceleration to gravity mode.
3. When the display show “U9.○ 00” ( ○ for flash digit) repeat the steps 1)-3) .press [UNITS] the display
will return the normal weighing mode.
Prepared by:Lin
Data:2007-01
Version:V3.3
Product Description
MS3200 indicator
Page:7 of 7
Product Type:MS3200
interface:
1:signal interface:
(microphone socket)
Pin 1(red)-------E+(positive source)
Pin 2(blue)-------S+(positive signal)
Pin 3(black)-------E-(negative source)
Pin 4 (white)-------S-(negative signal)
Pin 5(no)
no sign
-------GND
2:Rechargeable battery socket:
AC/DC 9V――――――inner positive ,external negative
3:RS232 interface:DB9
Prepared by:Lin
Data:2007-01
Version:V3.3
Was this manual useful for you? yes no