Flo DMX-control of motorised dimmer shutter and

Flo DMX-control of motorised dimmer shutter and
Manual
RJNET
For Compact followspot range
• 1159B – Victor
• 1459B – Flo
DMX-control of motorised dimmer
shutter and lamp ignition
RJNET version: V1.2
Valid since: 21/07/09
DN40974700
Robert Juliat S.A.S. Route de Beaumont, F60530 Fresnoy-en-Thelle - phone : +33 (0)3 44 26 51 89 - fax : +33 (0)3 44 26 51 89 - info@robertjuliat.fr
Robert Juliat U.S.A. 48 Capital Drive, Wallingford, CT 06492 – USA - phone : (203) 294 0481 - fax : (203) 294 0482 - info@robertjuliatamerica.com
Summary :
1
2
3
4
5
6
User instructions ..........................................................................................................................1
Presentation.................................................................................................................................2
2.1 RJNET ...................................................................................................................................2
2.2 Optional accessories ..............................................................................................................2
Installation ...................................................................................................................................3
3.1 Mechanics..............................................................................................................................3
3.2 Electrical ................................................................................................................................3
3.2.1
Power supply. ................................................................................................................4
3.2.2
DMX ..............................................................................................................................4
3.2.3
RJBUS...........................................................................................................................4
3.3 Accessories............................................................................................................................5
3.3.1
P1FCAN ........................................................................................................................5
3.3.2
Scroller colour changers.................................................................................................5
Operation.....................................................................................................................................6
4.1 Lamp......................................................................................................................................6
4.1.1
Lamp ignition .................................................................................................................6
4.1.2
Lamp hour counter.........................................................................................................6
4.1.3
Lamp strike counter........................................................................................................6
4.2 Dimmer shutter.......................................................................................................................6
4.2.1
Control ...........................................................................................................................6
4.2.2
Master control ................................................................................................................6
4.2.3
Emergency mode...........................................................................................................7
4.3 RJNET control board ..............................................................................................................7
4.3.1
Display and controls.......................................................................................................7
4.3.2
Menus and parameters ..................................................................................................8
4.3.3
Feedback information...................................................................................................10
4.4 Remote control by DMX protocol : ........................................................................................11
Service ......................................................................................................................................12
5.1 Preventive maintenance .......................................................................................................12
5.1.1
Frequency....................................................................................................................12
5.1.2
General cleaning..........................................................................................................12
5.1.3
General visual check....................................................................................................12
5.1.4
Wiring & Connections...................................................................................................12
5.1.5
PSU LED .....................................................................................................................13
5.1.6
Light sensor .................................................................................................................13
5.1.7
Shutter limit stop ..........................................................................................................13
5.2 Analyse ................................................................................................................................13
5.3 Spare parts...........................................................................................................................14
Troubleshooting .........................................................................................................................14
Robert Juliat reserve the right to change
or alter any of the items detailed on this page,
to increase or improve manufacturing techniques without prior notice.
1 User instructions
GENERAL INSTRUCTIONS
1. Not for residential use.
2. In addition to the instructions indicated on this page, relevant health and safety requirements
of the appropriate EU Directives must be adhered to at all times.
3. This fixture is in compliance with section 17 – Lighting appliance for theatre stages, television,
cinema and photograph studios. Standards NF EN 60598-1 and NF EN60598-2-17.
4. This fixture is rated as IP20, and is for indoor use only.
SERVICE
1. These fixtures must only be serviced by a qualified technician.
2. Disconnect from mains supply before servicing.
3. Use only with correct power supply.
4. Regularly remove dust from the product.
PLEASE NOTE
These products have been built to conform to European standards relating to professional lighting
equipment. Any modification made to our products will void the manufacturers' warranty.
-1-
2 Presentation
2.1
RJNET
Functions :
1.
2.
3.
4.
2.2
RJNET control board
Dimmer local control
Followspot power connector
Data and accessories connectors
5.
6.
7.
8.
9.
10.
PSU Lamp hour counter
PSU lamp switch
PSU mains LED
PSU mains breaker
PSU power connector
PSU lamp on LED
Optional accessories
1
2
Reference
P1FCAN
Contact RJ
1
-2-
Description
Dimmer remote control for RJNET
215x215mm gel frame holder for scroller
3 Installation
3.1
Mechanics
•
•
•
3.2
No hardware installation is required. The network is already installed with the follow spot.
For followspot installation: please refer to followspot manual.
Maximum ambient temperature: 40°C.
Electrical
RJNET Dimmer*
Followspots
Dimmer local control
CONTROL BOARD
Dimmer
local control
DMX Passes Through the Module
No data conversion —> faster transmission
Module continues to receive DMX
even if the control board crashes
Parameters
DMX address
DMX control
Feedback
DMX
RJNET
24V PSU
CANBUS
DMX
Dimmer local control
DMX control
DMX Console
P1FCAN local controller
To control the dimmer from the
followspot location
Additional accessories
using 24V PSU & DMX*
* Contact RJ for compatibility
-3-
For followspot electrical connection: please refer to followspot manual.
3.2.1
•
•
•
3.2.2
•
•
Power supply.
RJNET includes a 24V – 60W PSU.
Electrical connection is made in the lamp house of using the main power supply of the
followspot. No external connection is required.
RJNET is powered on when PSU main breaker is on.
DMX
Remote control uses USITT DMX 512-A protocol.
Input and output connections are using XLR 5-pin connectors.
XLR 5-pin Description for DMX
Pin 2
Pin 3
Pin 4
Pin 1
st
Cable
definition
1 conductor
Foil &
Braided of 1st twisted
Shield pair
Designation
3.2.3
•
•
nd
st
Pin 5
nd
2 conductor
of 1st twisted
pair
1 conductor
of 2nd twisted
pair
2 conductor
of 2nd twisted
pair
DMX (+)
unused
unused
DMX (-)
RJBUS
P1FCAN controller or additional accessories are using RJBUS connection.
External RJBUS connector is XLR 7-pin.
Pin 1
XLR 7-pin Description for external RJBUS Accessories
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
st
1
conductor
st
of 1
twisted
pair
nd
2
conductor of
st
1 twisted
pair
Pin 7
Housing
nd
2
st
1 conductor
conductor of
nd
of 2 twisted
nd
2 twisted
pair
pair
Cable
definition
Data
Conductor
Color cable
black
green
yellow
pink
gray
blue
red
Green /
yellow
Designation
0V
DMX (-)
DMX (+)
CAN Low
Can High
0V
+24V
Ground
-4-
Power
Conductor
Power
Conductor
Power
Conductor
3.3
Accessories
3.3.1
P1FCAN
OK
NO
OK
OK
•
•
•
3.3.2
•
•
•
•
PF1CAN controller can be attached to the handle thanks to the clips provided, or mounted to
the housing with the included magnets.
Warning: Never use the PF1CAN on the lamp house.
Connect the XLR7 connector to the RJBUS connector.
Switch has to be on dimmer position to operate from the PF1CAN.
Scroller colour changers
24Volt/DMX controlled accessories like scroller colour changers can be connected to the
XLR7-connector (RJBUS).
Warning: maximum load = 30W.
Adaptor XLR7- to XLR4- is required by using pins 1-2-3-5-7.
Front gel frame holder is available for standard scroller colour changer; please contact Robert
Juliat for details.
-5-
4 Operation
4.1
Lamp
4.1.1 Lamp ignition
Lamp can be ignited (switched on) by using:
• local switch on power supply unit.
• local value on RJNET control board (cf. 4.3.2)
• remote control by DMX protocol (cf. 4.4)
à If the power supply unit switch is on, it's not possible to turn off the lamp by RJNET control board or
by DMX.
4.1.2
Lamp hour counter
• on power supply unit (PSU)
• on RJNET control board (cf. 4.3.1)
à Power supply units can be swapped with other followspots. Refer to RJNET control board hour
counter to have accurate information about the lamp.
4.1.3 Lamp strike counter
Number of strikes of the lamp (ignition) is given by the RJNET control board in the TEST menu
(cf.4.3.2).
4.2
Dimmer shutter
4.2.1 Control
Dimmer shutter (light intensity) can be controlled by using :
• local value on RJNET control board
• local control handle
• P1FCAN local controller
• remote control by DMX protocol
à HTP mode (Highest Takes Precedence): dimmer shutter value will be the highest value of the four
sources.
Dimmer shutter is controlled on 16bits mode:
Luminous Flux
Closed
25%
50%
75%
100%
16bits DMX Value
0
16383
32767
49151
65535
4.2.2 Master control
In order to supervise the operator from the console, a 3rd DMX channel is used: Master control.
This channel limits the maximum value of the dimmer shutter.
By using this function, it's possible to obtain synchronised fades with several spots or to give intensity
limits (minimum and maximum) to the operator. Master is only active when DMX is detected.
Local handle,
DMX 16Bits
Master control
Local value
Dimmer aperture
(DMX Ch.1 & 2)
(DMX Ch.3 )
or P1FCAN
0%
0%
0 —> 100%
0%
0%
100%
0 —> 100%
0 —> 100%
0%
50%
0 —> 100%
0 —> 50%
20%
80%
0 —> 100%
20 —> 80%
-6-
4.2.3 Emergency mode
By unplugging the DMX IN connector, the following message will be displayed:
“Push select to reset DMX values”
à By pushing select, DMX values will be deactivated until DMX comes back, so local control values
(local control handle, RJNET, P1FCAN) will control the module from 0 to 100%.
4.3 RJNET control board
The RJNET control board allows:
• set-up DMX address
• reset each module independently without turning off the unit
• see feedback information
• do tests and adjusts local values
4.3.1
Display and controls
1
2
3
4
5
6
7
display
exit
+
select
reset
Data
Display
Exit the current menu option and/or go back
Scrolls through menus and/or Decrease blinking data value
Scrolls through menus and/or Increase blinking data value
Enter the current menu option and/or valid
Hard CPU reset
DMX LED feedback
Main view activated after 5 seconds of inactivity:
Dimmer control :
Highest command detected
d: DMX
a: Local control (handle)
p: P1FCAN
l: Local value
M: Master
Dimmer level
(bargraph)
Dimmer value
(%)
Lamp:
Sun = ON
Moon= OFF
If « * » flickering :
Value on mode control
Lamp hour counter
-7-
Master value
4.3.2
Menus and parameters
Select
Access to followspot main parameters.
F I X T U R E
P A R A M E T E R S
R J
H M I
F O L L O WS P O T
D M X
Select
-
c h a n n e l
0 0 1
Select
D M X
+
P o w e r
U p
O F F
-
Select
+
D M X
-
DMX address of the first channel.
M o d e
P o w e r
U p
O F F
Select
Select
D M X
Select
OFF
ON
B a c k l i g h t
O F F
-
Select
+
Select
O f f - T i m e
Display backlight switches off automatically
after X secondes of inactivity.
Value (-/+)
OFF
ON
F l a s h
L i g h t
Select
+
Select
F e e d b a c k
O F F
F l a s h
L i g h t
OFF
ON
-8-
Function
Display backlight always on
Display backlight switches off
after X secondes
Display backlight flashes when problem is
detected on RJNET.
Value (-/+)
-
Function
Access to the DMX address of
the 1st channel only
Possibilty to address each DMX
channel independantly
O f f - T i m e
B a c k l i g h t
O F F
F e e d b a c k
O F F
Function
Manual ignition
Automatic ignition
Allows to set-up independent DMX address for
each channel.
Value (-/+)
P a t c h
O F F
Function
DMX address
Lamp switches on (ignition) automatically
when unit is powered on.
Value (-/+)
OFF
ON
M o d e
P a t c h
O F F
+
Value (-/+)
1 à 512
c h a n n e l
0 0 1
Function
Disable display
backlight feedback
Enable display
backlight feedback
Access to each DMX channel:
• local values adjustment
• Individual DMX addressing
• Feedback information (see 4.3.3)
M O D U L E S
P A R A M E T E R S
R J
H M I
F O L L O WS P O T
DMX address
Select
M . c o n t r l
O n
s t a g e
Feedback
Status 4.3.3
Select
Lamp status
0 0 1
L p
0 d
O F F
1 2 h
Access to main control channel :
Lamp
counter
Highest value
M . c o n t r
C h a n n e l
l
0 0 1
L p
0 d
O F F
0 0 h
Value (-/+)
1 à 512
Function
Followspot DMX address
M . c o n t r
C h a n n e l
l
0 0 1
L p
0 d
O F F
0 0 h
Value (-/+)
OFF
ON
Function
Lamp OFF
Lamp ignition (see 4.1)
-
Select
+
DMX address
D i m m e r
0 0 2
0 0 3
0 0 4
O n
s t a g e
0 d
0 d
0 d
Feedback
Status 4.3.3
Select
Access to dimmer shutter channel:
Highest value
Highest command
Select
Select
Select
D i m . H i B
C h a n n e l
0 0 2
0 0 3
0 0 4
0 l
0 l
0
Dimmer (High Byte)*
D i m . L o B
C h a n n e l
0 0 2
0 0 3
0 l
0 l
0 0 4
0 l
Dimmer fine (Low Byte)*
D i m . M s t
C h a n n e l
0 0 2
0 0 3
0 l
0 l
0 0 4
0 l
Master function *
Value (-/+)
1 à 512
Function
Channel DMX address*
*if DMX patch activated
Select
D i m . H i B
L o c a l
V
0 0 2
0 0 3
0 0 4
0 l
0 l
0
Dimmer (High Byte)
Select
D i m . H i B
L o c a l
V
0 0 2
0 0 3
0 0 4
0 l
0 l
0
Dimmer fine (Low Byte)
Select
D i m . M s t
L o c a l
V
0 0 2
0 0 3
0 l
0 l
Master function
0 0 4
0 l
Value (-/+)
0 à 255
Function
Channel level
-9-
T E S T / V E R S I O N
R J
H M I
F O L L O WS P O T
Select
S e l e c t
f o r
t e s t
M . c o n t r l
V X - X X
Test and reset of functions.
Information about system version.
RJNET test
VX-XX: RJNET version
i n g
•
-
Select
-
+
+
S e l e c t
D i m m e r
-
Select
P r o t o c o l
1 2 3 4 5 . 6 h
f o r
t e s t
V X - X X
x x x x
x x x x
x x x x
x x x x
D M X
0 1 2 s
1 2
1 2 3 4 °
•
•
•
Prototocol: protocol detected and number
of channel received
12345.6h: lamp hour counter
012s: lamp strike (ignition) counter
1234°: RJ data
Dimmer shutter reset and test
VX-XX: dimmer version
i n g
x x x x
x x x x
x x x x
x x x x
Contact RJ service centre with this information
in case of failure
+
S e l e c t
t o
g o
b a c k
F A C T O R Y
S e t t i n g
t o
I N F O R M A T I O N
R J
H M I
F O L L O WS P O T
Push select to reset all parameters and go
back to factory settings
RJ contact details
www.robertjuliat.fr
Select
info@robertjuliat.fr
Select
P H : + 3 3 ( 0 ) 4 4 2 6 5 1 8 9
Select
4.3.3
Feedback information
•
Error data LED indicator:
Ø Green = DMX 512 detected
Ø Red = DMX problem
•
If DMX 512 not detected, the following message will be displayed on the screen:
“Push select to reset DMX values”
By pushing select, DMX values will be deactivated until DMX comes back, so local control values
(local control handle, RJNET, P1FCAN) will control the module from 0 to 100%.
Master control is automatically deactivated when DMX is disconnected.
•
Thanks to RJNET, it’s possible to have feedback information for the following functions (modules):
Ø RJNET control board (M. control)
Ø Dimmer shutter
- 10 -
In MODULE PARAMETERS menu:
Function
D i m m e r
0 0 2
0 0 3
0 0 4
O n
s t a g e
0 d
0 d
0 d
Feedback
Status 4.3.3
Highest value
Highest command
Ø Highest command and value:
Current value recognized by the dimmer shutter (highest value of the 5 sources - HTP mode)
Symbol
Command
DMX
d
Local control (handle)
a
P1FCAN
p
Local value
l
Master
M
Ø Feedback status :
Current status of the function
Symbol
Discon.
On stage
Failure
Command
Module not detected by the system
No problem detected
Problem detected on the module
à In case of failure on module: push select to reset the module.
In the main view:
If Feedback Flash Light function is activated in FIXTURES PARAMETERS menu, backlight of
the display will flash until any button pressed. Details and reset can be done from the
MODULE PARAMETERS menu or by DMX.
4.4
Remote control by DMX protocol :
DMX Channel
Mode
control
1
Dimmer
2
3
4
DMX value
134*
135*
144*
145*
150*
220*
225*
230*
235*
240*
245*
250*
253*
255*
Function
DIMMER Test
DIMMER Reset
CONTROL BOARD Test
CONTROL BOARD Reset
RJNET Reset
Local command = ON
Local command = OFF (DMX only)
Feedback flash light = OFF
Feedback flash light = ON
Backlight off-time = OFF
Backlight off-time = ON
Lamp OFF
Lamp at 50%
Lamp ON
Dimmer (High Byte)
0 - 65535
Dimmer fine (Low Byte)
0 - 255
Dimmer Master
*Value has to be maintained for 3 seconds to activate the function.
Value 0 is required to activate second function.
- 11 -
5 Service
5.1
Preventive maintenance
5.1.1 Frequency
General maintenance should be performed at least once a year, or more frequently if the equipment is
operated in adverse conditions (smoke, heat, humidity, touring, etc.).
5.1.2 General cleaning
Remove dust from the unit (air vents, printed circuit cards, etc.).
5.1.3
•
•
•
•
5.1.4
•
•
•
•
General visual check
No trace of heat.
No loose contacts.
No missing parts.
Tighten mechanical assemblies (screws, bolts and nuts, ground connections, etc.).
Wiring & Connections
Cable terminal screw: Visually check, tighten if necessary (do not over tighten).
Electronic connectors: Visually check the position and the locking clips (if needed).
Printed circuit board: Visually check all the components mounted in the sockets on the card.
Jumper: Visually check if they are correctly mounted:
Dimmer card :
Jumper on: W1 – W2 – W6 – W5
Control board :
Jumper on: W1 – W4 – W5 – W8
Dimmer card
Control board card
- 12 -
5.1.5 PSU LED
3 red LED are located on each electronic card (RJ NET control board and motor).
LED on indicates PSU is OK.
5.1.6 Light sensor
Remove dust from the light sensor conduct.
5.1.7 Shutter limit stop
Remove dust from shutter limit stops.
5.2 Analyse
In there is still a problem after the Troubleshooting procedures (Cf. 6.), contact RJ distributor with the following
information:
• Model and serial number of the followspot.
• RJNET version*.
• Dimmer version*.
• Data given by the dimmer test*.
• Description of the problem.
*Values available in the TEST/VERSION menu (Cf. 4.3.2)
- 13 -
5.3
Spare parts
Code
1159P20015
CE0636C278
CE0682C250
ME03M37001
ME03002001
COT0002201
6
Description
Control handle potentiometer with cable
DMX driver for Control board card (U6) and Motor card (U7)
CANBUS driver for Control board card (U5) and Motor card (U10)
375mA fuse for Control board card (F1)
2A fuse for Motor card (F1)
Jumper
Troubleshooting
Please refer to followspot manual concerning light or PSU problems.
SYMPTOMS
DMX LED feedback
is red
Protocol detected
in M.contrl test is
Impossible to
DMX ERROR
command the
fixture by DMX
No response
Only mode control
is activated by
DMX
POSSIBLE CAUSES
DMX data wiring
Check connectors and data cable
DMX protocol
problem
Check data signal
DMX address
Check DMX address of the 1st channel in
FIXTURE PARAMETERS menu
DMX patch on
Disable DMX Patch function I FIXTURE
PARAMETERS menu
DMX value sent by
DMX
Impossible to completely close the
dimmer with the local handle
Impossible to completely open the
dimmer with the local handle
Impossible to switch the lamp off by
RJNET control board or by DMX
Local value on
RJNET control board
PF1CAN controller
has been
disconnected with
value different from 0
Iris closed
Master value sent by
DMX
Power supply unit
switch is on
Problem detected by control board
DMX LED feedback is red even if
DMX unplugged
SOLUTIONS
Faulty data driver
component
- 14 -
Disconnect DMX and push select to reset
DMX. Check if DMX value on Master control
channel
Check on dimmer view that no local value is
entered (symbol: “l”)
Connect the P1FCAN controller and turn
the button to 0
Open manually the iris
Disconnect DMX and push select to reset
DMX. Check if DMX value on Master control
channel
Switch off the lamp with power supply unit
switch
Go to MODULES PARAMETERS, check if
M.Contrl or Dimmer are in failure mode. If
yes, push select on corresponding view.
Contact RJ service centre to change the
componant
Was this manual useful for you? yes no