Smoke and Carbon Monoxide Alarm

Smoke and Carbon Monoxide Alarm
User Guide for Model i12010SCO
Combination
Smoke and
Carbon Monoxide
Alarm
• 120V AC
• Sealed 3V Lithium Battery
Backup
• 2-LED Display
• Peak Level Memory
• Test/Hush® button
• Voice Message System
10 YEAR SMOKE AND
CARBON MONOXIDE ALARM
GREENSTANDBY
For questions concerning your Smoke and Carbon Monoxide
Alarm, please call our Product Support Line at 1-800-880-6788.
For your convenience, write down the following information. If you call
our Product Support Line, these are the first questions you will be asked:
Alarm Model Number
(located on back of the alarm):
Date of Manufacture
(located on back of the alarm):
Date of Purchase:
Where Purchased:
READ AND SAVE THIS USER GUIDE
P/N 2550-7201-00 EN
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1
Product View . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 4-7
Installation Instructions
Step 1: Installation Instructions:
A. Recommended Installation Locations . . Pages 8-10
B. Where Not to Install . . . . . . . . . . . . . . . Page 10
Step 2: Wiring Instructions . . . . . . . . . . . . . . . . Page 11-12
Step 3: Mounting Instructions.. . . . . . . . . . . . . . Page 13-14
Step 4: Testing the Alarm. . . . . . . . . . . . . . . . . . Page 14
Operating Instructions
Interconnect Feature . . . . . . . . . . . . . . . . . . . . . Page 15
HUSH Control Feature . . . . . . . . . . . . . . . . . . . . Page 15-16
Reset Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 16
Peak Level Memory . . . . . . . . . . . . . . . . . . . . . . Page 16
LED Indicator Operation . . . . . . . . . . . . . . . . . . . Page 17
Tamper Resist Feature . . . . . . . . . . . . . . . . . . . . Page 17-18
What to do if the Alarm Sounds
Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 18-19
Carbon Monoxide Alarm . . . . . . . . . . . . . . . . . . Pages 20
Alarm Removal/Battery . . . . . . . . . . . . . . . . . . . Pages 21-22
DEACTIVATION OF ALARM . . . . . . . . . . . . . . . . . Page 22
General Alarm Maintenance . . . . . . . . . . . . . . . Pages 23-24
End of Product Life Notification . . . . . . . . . . . . . Page 23
Carbon Monoxide Safety Information
General CO Information . . . . . . . . . . . . . . . . . . Page 24
Possible Sources . . . . . . . . . . . . . . . . . . . . . . . . Page 24
CO Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . Page 25
Symptoms of CO Poisoning . . . . . . . . . . . . . . . Page 25-26
Fire Safety Information
Escape Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26
Fire Prevention . . . . . . . . . . . . . . . . . . . . . . . . . . Page 27
Industry Safety Standards
National Fire Protection Association . . . . . . . . . Page 27-28
California State Fire Marshall . . . . . . . . . . . . . . . Page 28
Consumer Product Safety Commission. . . . . . . . Page 28
NRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 28
Limited Warranty and Service Information. . . . Pages 29-30
Product Registration . . . . . . . . . . . . . . . . . . . . . . Page 30
Introduction
Thank you for purchasing the Kidde Combination Smoke and
Carbon Monoxide Alarm model # i12010SCO. This alarm is
suitable as a Single Station and/or Multiple Station (24 devices)
alarm. This alarm has a ten-year limited warranty. Please take a
few minutes to thoroughly read this user guide, and save for
future reference. Teach children how to respond to the alarms,
and that they should never play with the unit. Your Kidde
Smoke/CO Alarm was designed to detect both smoke and
carbon monoxide from any source of combustion in a residential
environment. It is not designed for use in a recreational vehicle
(RV) or boat. If you have any questions about the operation or
installation of your alarm, please call our toll free Product Support
Line at 1-800-880-6788. The guide on Page 27 will help you
determine the correct location of safety products that will help
keep your home a safer place.
1
Product View
FRONT
VOICE SPEAKER
RED AND GREEN LED
10 YEAR SMOKE AND
CARBON MONOXIDE ALARM
GREENSTANDBY
ALARM SOUNDER
2
Product View
BACK
3
Features
• Loud 85 decibel alarm.
• Permanent independent smoke and carbon monoxide sensors.
• Smoke alarm takes precedence when both smoke and
carbon monoxide are present.
• Powered by 120V AC (60 Hz, 7.5mA max) wire-in connector
and sealed 3V Lithium battery backup.
• Interconnectable to other Kidde/Nighthawk brand smoke and
CO alarms (see page 15 for details).
• Alarm/Voice message warning system that alerts you of the
following conditions in the manner described below, thus
eliminating any confusion over which alarm is sounding:
FIRE: The alarm/voice pattern is three long alarm beeps
followed by the verbal warning message “FIRE!” This pattern
is repeated until the smoke is eliminated. The red LED light will
flash while in alarm/voice mode.
CARBON MONOXIDE: The alarm/voice pattern is four short
alarm beeps followed by the verbal warning message
“WARNING! CARBON MONOXIDE!". This continues until the
unit is reset or the CO is eliminated. While powered by battery
only, after four minutes the alarm/voice pattern will sound
once every minute. The red Light Emitting Diode (LED) light will
flash while in alarm/voice mode.
LOW BATTERY: If the battery is low, the red LED light will flash
and the unit will “chirp” one time, followed by the warning
message “LOW BATTERY.” This alarm contains a sealed 3V
Lithium battery, which will last the life of the alarm. No need
to replace batteries. This cycle will occur once every minute and
will continue for at least seven days. Under battery power, the
"LOW BATTERY" voice only occurs once every 15 minutes.
• Voice Message System that alerts user to the following
conditions:
– Only for smoke alarm Hush
System announces “HUSH MODE ACTIVATED” when
the unit is first put into HUSH Mode.
– Only for smoke alarm Hush
4
Features
System announces “HUSH MODE CANCELLED” when
unit resumes normal operation after Hush Mode has
been cancelled.
– Only if button is pushed
System announces “CARBON MONOXIDE PREVIOUSLY
DETECTED” when the unit has detected CO
concentrations of 100 ppm or higher.
– System announces “PUSH TEST BUTTON” when the unit
is powered up, reminding user to activate the Test
Button.
• End of Life Hush. At end of product life, the button can be
pushed to silence the end of life "chirp" for approximately
3 days at a time, for a maximum of 30 days life extension.
• One “chirp” every 30 seconds coupled with a green LED flash
twice a second is an indication that the alarm is
malfunctioning. If this occurs call the Product Support Line at
1-800-880-6788.
• Test/Reset button performs functions.(See page 14).
• HUSH Control Feature that silences the unit during nuisance
alarm situations (see page 15).
• Peak Level Memory Feature which alerts user when the unit
has detected CO concentrations of 100 ppm or greater (see
page 16).
• Alarm Memory Feature that gives visual indication when an
alarm has sensed a hazardous condition.
• Green and red LED lights that indicate normal operation and
alarm status (see page 17 for details).
• Tamper Resist Feature that deters children and others from
removing the alarm (see page 17).
5
Features and General Information
Smoke Alarm
The smoke alarm monitors the air for products of combustion
that are produced when something is burning or smoldering.
When smoke particles in the smoke sensor reach a specified
concentration, the alarm/voice message warning system will
sound, and be accompanied by the flashing red LED light. The
smoke alarm takes precedence when both smoke and carbon
monoxide are present.
!
WARNING: PLEASE READ CAREFULLY AND
THOROUGHLY
NFPA 72 states: Life safety from fire in residential occupancies is
based primarily on early notification to occupants of the need to
escape, followed by the appropriate egress actions by those
occupants. Fire warning systems for dwelling units are capable of
protecting about half of the occupants in potentially fatal fires.
Victims are often intimate with the fire, too old or young, or
physically or mentally impaired such that they cannot escape
even when warned early enough that escape should be possible.
For these people, other strategies such as protection-in-place or
assisted escape or rescue are necessary.
• Smoke alarms are devices that can provide early warning of
possible fires at a reasonable cost; however, alarms have
sensing limitations. Ionization sensing alarms may detect
invisible fire particles (associated with fast flaming fires) sooner
than photoelectric alarms. Photoelectric sensing alarms may
detect visible fire particles (associated with slow smoldering
fires) sooner than ionization alarms. Home fires develop in
different ways and are often unpredictable. For maximum
protection, Kidde recommends that both Ionization and
Photoelectric alarms be installed.
• A battery powered alarm must have a battery of the specified
type, in good condition and installed properly.
• Smoke alarms must be tested regularly to make sure the
batteries and the alarm circuits are in good operating
condition.
• Smoke alarms cannot provide an alarm if smoke does not
reach the alarm. Therefore, smoke alarms may not sense fires
starting in chimneys, walls, on roofs, on the other side of a
closed door or on a different floor.
6
Features and General Information
• If the alarm is located outside the bedroom or on a different
floor, it may not wake up a sound sleeper.
• The use of alcohol or drugs may also impair one’s ability to hear
the smoke alarm. For maximum protection, a smoke alarm
should be installed in each sleeping area on every level of a
home.
• Although smoke alarms can help save lives by providing an
early warning of a fire, they are not a substitute for an
insurance policy. Home owners and renters should have
adequate insurance to protect their lives and property.
Carbon Monoxide (CO) Alarm
The Carbon Monoxide (CO) alarm monitors the air for the
presence of CO. It will alarm when there are high levels of CO
present, and when there are low levels of CO present over a
longer period of time (see page 21 for alarm times). When a CO
condition matches either of these situations, the alarm/voice
message warning system will sound, and be accompanied by the
flashing red LED light. The carbon monoxide sensor uses an
electrochemical technology.
! CAUTION: This alarm will only indicate the presence of
carbon monoxide gas at the sensor. Carbon monoxide gas
may be present in other areas.
Individuals with medical problems may consider using warning
devices which provide audible and visual signals for carbon
monoxide concentrations under 30 ppm.
7
Installation Instructions
Step 1
Installation Guide:
IMPORTANT: THIS ALARM MUST BE MOUNTED ON A
CEILING OR WALL. IT WAS NOT DESIGNED FOR USE AS A
TABLETOP DEVICE! INSTALL ONLY AS DETAILED!
A. Recommended Installation Locations:
Kidde Safety recommends the installation of a Smoke/CO Alarm
in the following locations. For maximum protection we suggest
an alarm be installed on each level of a multilevel home,
including every bedroom, hallways, finished attics and
basements. Put alarms at both ends of bedroom, hallway or large
room if hallway or room is more than 30 ft (9.1m) long. If you
have only one alarm, ensure it is placed in the hallway outside of
the main sleeping area, or in the main bedroom. Verify the alarm
can be heard in all sleeping areas.
Locate an alarm in every room where someone sleeps with the
door closed. The closed door may prevent an alarm not located
in that room from waking the sleeper. Smoke, heat and
combustion products rise to the ceiling and spread horizontally.
Mounting the alarm on the ceiling in the center of the room
places it closest to all points in the room. Ceiling mounting is
preferred in ordinary residential construction. When mounting an
alarm on the ceiling,
locate it at a minimum
of 4” (10cm) from the
side wall (see figure
1). If installing the
alarm on the wall, use
an inside wall with the
top edge of the alarm
at a minimum of 4”
(10cm) and a maximum
of 12” (30.5cm) below
the ceiling (see figure
1).
8
FIGURE 1
Installation Instructions
Sloped Ceiling Installation:
The following information is from the National Fire Protection
Association and is listed in Fire Code 72.
Install Smoke Alarms on sloped, peaked or cathedral ceilings at,
or within 3 ft (0.9m) of the highest point (measured horizontally).
NFPA 72 states “Smoke alarms in rooms with ceiling slopes
greater than 1 ft to 8 ft (.3 m-2.4 m) horizontally shall be located
on the high side of the room”.
NFPA 72 states “A row of alarms shall be spaced and located
within 3 ft (0.9 m) of the peak of the ceiling measured
horizontally” (see figure 2).
Install Smoke Alarms on tray-shaped ceilings (coffered ceilings)
on the highest portion of the ceiling or on the sloped portion of
the ceiling within 30.5 cm (12”) vertically down from the highest
point (see figure 2).
ANYWHERE IN
THIS AREA
30 cm (12”)
FIGURE 2
Mobile Homes:
Modern mobile homes have been designed and built to be
energy efficient. Install Smoke/CO alarms as recommended
above (refer to Recommended Installation Instructions and figure
1). In older mobile homes that are not well insulated, extreme
9
Installation Instructions
heat or cold can be transferred from the outside to the inside
through poorly insulated walls and roof. This may cause a
thermal barrier, which can prevent smoke from reaching an alarm
mounted on the ceiling. In such mobile homes install your
Smoke/CO Alarm on an inside wall with the top edge of the
alarm at a minimum of 4 inches (10cm) and a maximum of 12
inches (30.5cm) below the ceiling (see figure 2). If you are not
sure about the insulation in your mobile home, or if you notice
that the outer walls and ceiling are either hot or cold, install your
alarm on an inside wall ONLY!
THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE
WITH THE NATIONAL FIRE PROTECTION ASSOCIATION’S
STANDARD 72 (National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269).
WARNING - This product is intended for
!
use in ordinary indoor locations of family
living units. It is not designed to measure
compliance with Occupational Safety and
Health Administration (OSHA) commercial
or industrial standards.
B. Where Not to Install:
Do not install in garages, kitchens, furnace rooms or
bathrooms! INSTALL AT LEAST 5 FEET AWAY FROM ANY
FUEL BURNING APPLIANCE.
Do not install within 3 ft (.9m) of the following: The door to a
kitchen, or a bathroom that contains a tub or shower, forced air
supply ducts used for heating or cooling, ceiling or whole house
ventilating fans, or other high air areas. Avoid excessively dusty,
dirty or greasy areas. Dust, grease or household chemicals can
contaminate the alarm's sensors, causing it to not operate
properly.
Place the alarm where drapes or other objects will not block the
sensor. Smoke and CO must be able to reach the sensors to
accurately detect these conditions. Do not install in peaks of
vaulted ceilings, “A” frame ceilings or gabled roofs. Keep out of
damp and humid areas.
10
Installation Instructions
Install at least one (1) foot away from fluorescent lights,
electronic noise may cause nuisance alarms. Do not place in
direct sunlight and keep out of insect infested areas. Extreme
temperatures will effect the sensitivity of the Smoke/CO Alarm.
Do not install in areas where the temperature is colder than 40
degrees Fahrenheit (4.4˚ Celsius) or hotter than 100 degrees
Fahrenheit (37.8˚ Celsius), such as garages and unfinished attics.
Do not install in areas where the relative humidity (RH) is above
95%. Place away from doors and windows that open to the
outside.
Step 2
Wiring Instructions:
! WIRING REQUIREMENTS
• This smoke alarm should be installed on a U.L. listed or
recognized junction box. All connections should be made by a
qualified electrician and all wiring used shall be in accordance
with articles 210 and 300.3(B) of the U.S. National Electrical
Code ANSI/NFPA 70, NFPA 72 and/or any other codes having
jurisdiction in your area. The multiple station interconnect
wiring to the alarms must be run in the same raceway or cable
as the AC power wiring. In addition, the resistance of the
interconnect wiring shall be a maximum of 10 ohms.
• The appropriate power source is 120 Volt AC Single Phase
supplied from a non-switchable circuit, which is not protected
by a ground fault interrupter.
• Smoke alarms are not to be used with detector guards unless
the combination (alarm and detector guard) have been
evaluated and found suitable for that purpose.
•
! WARNING: The alarm cannot be operated from power
derived from a square wave, modified square wave or modified
sine wave, inverter. These types of inverters are sometimes
used to supply power to the structure in off grid installations,
such as solar or wind derived power sources. These power
sources produce high peak voltages that will damage the
alarm.
11
Installation Instructions
WIRING INSTRUCTIONS FOR AC QUICK CONNECT HARNESS
!
CAUTION! TURN OFF THE MAIN POWER TO THE
CIRCUIT BEFORE WIRING THE ALARM.
• For alarms that are used as single station, DO NOT CONNECT
THE RED WIRE TO ANYTHING. Leave the red wire insulating
cap in place to make certain that the red wire cannot contact
any metal parts or the electrical box.
• When alarms are interconnected, all interconnected units must
be powered from a single circuit.
• A maximum of 24 Kidde Safety devices may be interconnected
in a multiple station arrangement. The interconnect system
should not exceed the NFPA interconnect limit of 12 smoke
alarms and/or 18 alarms total (smoke, CO, Smoke/ CO
Combination, heat, etc.). This Smoke/CO combination alarm
must be counted as a smoke alarm when determining the
number of units on an interconnect line. With 18 alarms
interconnected, it is still possible to interconnect up to a total
of 6 remote signaling devices and /or relay modules (see page
15 for details on interconnecting Kidde devices).
• The maximum wire run distance between the first and last unit
in an interconnected system is 1000 feet.
FUSE OR CIRCUIT BREAKER
BLACK
RED
BLACK
WHITE
First
Alarm
RED
WHITE
CONNECTOR
Additional
Alarm
CONNECTOR
Kidde Relay Module
SM120X, CO120X
or both
Optional
Accessory
Additional
Alarm
FIGURE 3 Interconnect Wiring Diagram
WIRES ON ALARM HARNESS
Black
CONNECTED TO
Hot Side of AC Line
White
Neutral Side of AC Line
Red
Interconnect Lines (Red Wires) of
Other Units in the Multiple Station
Set up
12
Installation Instructions
• Figure 3 illustrates interconnection wiring.
Improper
connection will result in damage to the alarm, failure to
operate, or a shock hazard.
• Make certain alarms are wired to a continuous (non-switched)
power line. NOTE: Use standard UL Listed household wire (as
required by local codes) available at all electrical supply stores
and most hardware stores.
Step 3
Mounting Instructions:
! CAUTION: YOUR SMOKE/CO ALARM IS SEALED AND
THE COVER IS NOT REMOVABLE!
1. To help identify the date to replace the unit, write the "Replace
by" date (10 years from initial power up) in permanent marker
in the space provided on the side of the alarm. See Alarm
Replacement section for additional information.
2. Remove the mounting bracket from the back of the alarm by
holding the mounting bracket and twisting the alarm in the
direction indicated by the “OFF”arrow on the alarm cover.
3. After selecting the proper location for your Smoke/CO Alarm,
as described on Pages 8-10, and wiring the AC QUICK
CONNECT harness as described
in the WIRING INSTRUCTIONS
(NOTE: AC power should be
turned off at this stage), attach
the mounting bracket to the
electrical box. To ensure aesthetic
alignment of the alarm with the
hallway, or wall, the “A” line on
the mounting bracket must be
FIGURE 4
parallel with the hallway when
Installing AC Quick
ceiling mounted, or horizontal
Connect
when wall mounted.
4. Pull the AC QUICK CONNECTOR through the center hole in
the mounting bracket and secure the bracket, making sure
that the mounting screws are positioned in the small ends of
the keyholes before tightening the screws.
5. Remove the cardboard square from the connector pins and
plug the AC QUICK CONNECTOR into the back of the alarm (see
13
Installation Instructions
figure 4), making sure that the locks on the connector snap into
place. Then push the excess wire back into the electrical box
through the hole in the center of the mounting bracket.
6. Install the alarm on the mounting bracket and rotate the
alarm in the direction of the “ON” arrow on the cover until
the alarm ratchets into place (this ratcheting function allows
for aesthetic alignment). Note: The alarm will mount to the
bracket in 4 positions (every 90 degrees). NOTE: Installing the
alarm on the mounting bracket will automatically activate the
battery backup.
7. Turn on the AC power. The green AC Power On Indicator
should be lit when the alarm is operating from AC power.
8. Two labels are included with your alarm. They have important
information on what to do in case of an alarm. Add the
phone number of your emergency service provider (Fire
Department or 911) in the space provided. Place one label
next to the alarm after it is mounted, and one label near a
fresh air source such as a door or window.
Step 4
Testing the Alarm
! CAUTION: Due to the loudness (85 decibels) of the
alarm, always stand an arms length away from the unit
when testing.
After installation, TEST THE UNIT’S ELECTRONICS by pressing and
releasing the test/reset button. You will then hear the following
sequence of "beeps" and verbal warnings:
Three long beeps.
Verbal warning: "FIRE!"
Three long beeps.
Four quick beeps.
Verbal warning: “WARNING! CARBON MONOXIDE”
Four quick beeps
Single beep to reset
Weekly testing is required! If at anytime it does not perform as
described, verify power is connected correctly. Clean dust and
other buildup off the unit. If it still doesn’t operate properly call
the Product Support Line at 1-800-880-6788.
14
Operating Instructions
Interconnect Feature
Your Combination Smoke/CO Alarm is interconnectable to other
multiple station Kidde, Nighthawk and Kidde/Fyrnetics products:
• When compatible smoke alarms and heat alarms are
interconnected to your Smoke/CO Alarm, they will only
respond to a smoke related event.
• When mixing compatible models with battery backup with models
without battery backup, be advised that the models without battery
backup will not respond during an AC power failure.
• This unit is only approved to interconnect with other
Kidde/Nighthawk products. It is NOT approved to interconnect
with any other brand of detection product.
• This alarm is interconnect compatible with the following alarms
and accessories:
–Smoke alarms: 1235, 1275, 1276, 1285, i12020, i12020A,
i12040, i12040A, i12060, i12060A, i4618, i4618A,
KN-SMFM-I, RF-SM-ACDC, PE120, P12040, Pi2000, Pi2010,
i12080, i12080A, KN-COSM-I, KN-COSM-IB, KN-COSM-IBA
Kidde/Firex: i4618, i4618A
– Heat alarm: HD135F
– CO alarms: KN-COB-IC, KN-COP-IC, KN-COPE-I
– Relay modules: SM120X, CO120X
– Strobe Light: SL177i, SLED177i
• For more information about compatible interconnect units and
their functionality in an interconnect system, visit our web site
at www.kidde.com.
Smoke HUSH Control Feature
The HUSH feature has the capability of temporarily desensitizing
the smoke alarm circuit for approximately 9 minutes. This feature
is to be used only when a known alarm condition, such as smoke
from cooking, activates the alarm. When the unit is in alarm,You
can put your Smoke/CO Alarm in HUSH mode by pushing the
test/reset button. If the smoke is not too dense, the alarm will
silence immediately, the unit will verbally announce “HUSH
MODE ACTIVATED”, and the green LED will flash every 2 seconds
for approximately 9 minutes. This indicates that the smoke alarm
is in a temporarily desensitized condition. Your Smoke/CO Alarm
will automatically reset after approximately 9 minutes. When the
unit returns to normal operation after being in HUSH mode, it
will verbally announce “HUSH MODE CANCELLED”, and sound
the alarm if smoke is still present. The HUSH feature can be used
repeatedly until the air has been cleared of the condition causing
the alarm. While the unit is in HUSH mode, pushing the test/reset
button on the alarm will also end the HUSH period.
15
Operating Instructions
NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL
FEATURE AND SOUND A CONTINUOUS ALARM.
! CAUTION: BEFORE USING THE ALARM HUSH FEATURE,
IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A
SAFE CONDITION EXISTS.
Reset Feature
If the the Smoke/CO Alarm is sounding a CO alarm, pressing the
test/reset button will silence the alarm.
If the CO condition that caused the alert continues, the alarm will
reactivate within 200 seconds (follow the action plan on page
20).
CO Peak Level Memory
If the green LED is blinking once every 10 seconds, the unit has
detected a hazardous CO condition. If the CO sensor has detected a
CO level of 100 PPM or higher since last reset, it will be recorded by
the Peak Level Memory function. To access the Peak Level Memory
press the test/reset button. If a reading of 100 PPM or higher has
been recorded, the unit will announce “Carbon Monoxide Previously
Detected.” If you’ve been away from home this feature allows you
to check if there was a CO reading of 100, or higher, during your
absence. Pushing the test/reset button resets the memory. It’s also
reset when the power is removed. Note: the green LED blinking
portion of CO Peak Level Memory is disabled when the unit is on
battery power only.
LED Indicator Operation
Red LED
The red LED will flash as described below under the following
conditions:
--During smoke or CO alarm, with every beep
--During testing (same as alarm)
--Low battery, single flash with chirp
--End of product life, double flash every 30 seconds with chirp
--Unit error mode, single flash with chirp
--Unit error mode, a Fault Code is flashed every 30 seconds (can
be observed and reported to customer service for
troubleshooting).
16
Operating Instructions
Green LED
The green LED will flash as described below under the following
conditions:
– Standby Condition (powered by AC and battery backup):
The LED will be constantly on.
– Standby Condition (powered by only battery backup):
The LED will flash every 60 seconds..
– Alarm Memory Condition: The LED will flash every
second during alarm. When the alarm condition goes
away, the originating alarm unit will flash the LED every
16 seconds until the test/reset button is pressed, thus
resetting the alarm.
– CO Peak Memory (10 second flash rate), AC powered
only. Indicates CO greater than 100PPM was detected.
Press Test button to announce Peak message and clear
Peak Memory.
– Initiating Alarm condition (1 second flash rate), indicates
the unit initiated an alarm.
– Trouble Fault/Error mode (1/2 second flash rate), AC
powered only. Helps owner locate the mysterious
chirping unit
– HUSH MODE Condition: The LED will flash every 2
seconds while the alarm is in HUSH mode.
Tamper Resist Feature
To make your smoke/CO alarm tamper resistant, a tamper resist
feature has been provided. Activate the tamper resist feature by
breaking off the four posts in the square holes in the trim ring
(see figure 5A). When the posts are broken off, the tamper resist
tab on the base is allowed to engage the mounting bracket.
Rotate the alarm onto the mounting bracket until you hear the
tamper resist tab snap into place, locking the alarm on the
mounting bracket. Using the tamper resist feature will help deter
children and others from removing the alarm from bracket.
NOTE: To remove the alarm when the tamper resist tab is
engaged, press down on the tamper resist tab, and rotate the
alarm off of the bracket (see figure 5B).
17
Operating Instructions
A
A
Posts
FIGURE 5A
FIGURE 5B
NEVER IGNORE THE SOUND OF THE ALARM!
Determining what type of alarm has sounded is easy with your
Combination Smoke/CO Alarm. The voice message warning
system will inform you of the type of situation occurring. Refer
to the Features section on pages 4-7 for a detailed description of
each alarm pattern.
What To Do If The Alarm Sounds
When the smoke alarm sounds:
Smoke alarms are designed to minimize false alarms. Cigarette
smoke will not normally set off the alarm, unless the smoke is
blown directly into the alarm. Combustion particles from cooking
may set off the alarm if located too close to the cooking area.
Large quantities of combustible particles are generated from
spills or when broiling. Using the fan on a range hood which
vents to the outside (non recirculating type) will also help remove
these combustible products from the kitchen.
18
What To Do If The Alarm Sounds
If the alarm sounds, check for fires first. If a fire is discovered
follow these steps. Become thoroughly familiar with these items,
and review with all family members!
• Alert small children in the home.
• Leave immediately using one of your planned escape routes
(see page 26). Every second counts, don’t stop to get dressed
or pick up valuables.
• Before opening inside doors look for smoke seeping in around
the edges, and feel with the back of your hand. If the door is
hot use your second exit. If you feel it’s safe, open the door
very slowly and be prepared to close immediately if
smoke and heat rush in.
• If the escape route requires you to go through smoke, crawl
low under the smoke where the air is clearer.
• Go to your predetermined meeting place. When two people
have arrived one should leave to call 911 from a neighbor’s
home, and the other should stay to perform a head count.
• Do not reenter under any circumstance until fire
officials give the go ahead.
• There are situations where a smoke alarm may not be
effective to protect against fire as stated in the NFPA
Standard 72. For instance:
a) smoking in bed
b) leaving children unsupervised
c) cleaning with flammable liquids, such as gasoline
The CO sensor meets the alarm response time requirements of UL
standard 2034. Standard alarm times are as follows:
At 70 PPM, the unit must alarm within 60-240 minutes.
At 150 PPM, the unit must alarm within 10-50 minutes.
At 400 PPM, the unit must alarm within 4-15 minutes.
This carbon monoxide alarm is designed to detect carbon
monoxide gas from ANY source of combustion. It is NOT
designed to detect any other gas.
Fire Departments, most utility companies and HVAC contractors
will perform CO inspections, some may charge for this service.
It’s advisable to inquire about any applicable fees prior to having
the service performed. Kidde Safety will not pay for, or reimburse,
the owner or user of this product, for any repair or dispatch calls
related to the alarm sounding.
19
What To Do If The Alarm Sounds
When the carbon monoxide alarm sounds:
!
WARNING - Actuation of your CO
Alarm indicates the presence of Carbon
Monoxide (CO) which can kill you.
If alarm signal sounds:
1) Operate the test/reset button
PHONE NUMBER
2) Call your emergency
services (Fire Dept. or 911)
3) Immediately move to fresh air - outdoors or by an open
door/window. Do a head count to check that all persons
are accounted for. Do not reenter the premises nor move
away from the open door/window until the emergency
services responders have arrived, the premises has been
aired out, and your alarm remains in its normal
condition.
4) After following steps 1-3, if your alarm reactivates
within a 24 hour period, repeat steps 1-3 and call a
PHONE NUMBER
qualified appliance technician
to investigate for sources of
CO from fuel burning equipment and appliances, and
inspect for proper operation of this equipment. If
problems are identified during this inspection have the
equipment serviced immediately. Note any combustion
equipment not inspected by the technician and consult
the manufacturer’s instructions, or contact the
manufacturer’s directly, for more information about CO
safety and this equipment. Make sure that motor
vehicles are not, and have not been, operating in an
attached garage or adjacent to the residence.
Never restart the source of a CO problem until it has been
fixed. NEVER IGNORE THE ALARM!
20
Battery Information
Alarm Removal
IF TAMPER RESIST FEATURE HAS BEEN ACTIVATED, REFER
TO TAMPER RESIST FEATURE DESCRIPTION ON PAGE 17 FOR
REMOVAL INSTRUCTIONS.
Remove the alarm from the mounting bracket by rotating the
alarm in the direction of the “OFF” arrow on the cover.
Battery (Non-Replaceable)
If any form of battery failure is detected the red LED light will
flash and the unit will “chirp” one time, followed by the warning
message “LOW BATTERY”. This cycle will occur once every
minute, and will continue for at least seven days. On battery
power, the "LOW BATTERY" voice occurs once every 15 minutes.
Replace alarm immediately!.
THE UNIT MUST BE DEACTIVATED (see “Deactivation of
Alarm” section) and replaced within 7 days of the first
occurrence of the “Low Battery Warning” to provide
continuous alarm protection.
If the red LED light flashes along with a chirp every 30
seconds, as described above, and if the green LED flashes
twice per second (AC power only) your unit has
malfunctioned. Call our toll free Product Support Line at
1-800-880-6788 for instructions on how to return the unit.
End of Life Notification
Ten (10) years after unit is first powered, this alarm will beep two
times every 30 seconds to indicate it is time to replace the alarm.
REPLACE IMMEDIATELY! End of Life Hush can be activated
by pushing the test button to silence the End of Life chirp
for approximately 3 days at a time for a maximum of 30
day life extension.
21
DEACTIVATION OF ALARM
! WARNING:
a. Deactivation of the alarm is permanent. Once the
alarm has been deactivated, it cannot be reactivated!
b. Once deactivated, the alarm will NO LONGER DETECT
SMOKE or Carbon Monoxide.
c. Once the alarm is deactivated the battery will be
depleted and the alarm will no longer function.
d. Once the alarm has been deactivated, it cannot be
mounted onto the mounting plate or reactivated.
TO DEACTIVATE THE ALARM:
Remove the alarm from the mounting plate by rotating
it in the direction indicated by the arrows on the cover
of the alarm.
On back side of alarm, locate the area on
product label.
Break through label with a screw driver.
Slide the tab to the “OFF” location. This will
deactivate the alarm, stop the low battery “chirp”
and render the alarm safe for disposal by draining
the battery.
!
22
WARNING! Failure to turn off alarm as instructed prior
to disposal may create potential for lithium battery
related fire or hazard.
General Maintenance
To keep your Smoke/CO Alarm in good working order, please follow
these simple steps:
• Verify the unit's alarm and LED lights operation by pushing the
test/reset button once a week.
• Remove the unit from mounting bracket and vacuum the alarm
cover and vents with a soft brush attachment once a month to
remove dust and dirt. REINSTALL IMMEDIATELY AFTER CLEANING
AND THEN TEST USING THE TEST/RESET BUTTON!
• Never use detergents or other solvents to clean the unit.
• Avoid spraying air fresheners, hair spray, or other aerosols near the
Smoke/CO Alarm.
Do not paint the unit. Paint will seal the vents and interfere with the
sensor’s ability to detect smoke and CO. Never attempt to
disassemble the unit or clean inside. This action will void your
warranty.
Move the Smoke/CO Alarm and place in another location prior to
performing any of the following:
•
•
•
•
Staining or stripping wood floors or furniture
Painting
Wall papering
Using adhesives
Storing the unit in a plastic bag during any of the above projects will
protect the sensors from damage. Do not place near a diaper pail.
! WARNING: Reinstall the Smoke/CO Alarm as soon as possible
to assure continuous protection.
When household cleaning supplies or similar contaminates are used,
the area must be well ventilated. The following substances can
effect the CO sensor and may cause false readings and damage to
the sensor:
Methane, propane, iso-butane, iso-propanol, ethyl acetate,
hydrogen sulfide, sulfide dioxides, alcohol based products, paints,
thinner, solvents, adhesives, hair spray, after shave, perfume, and
some cleaning agents.
23
General Maintenance
Carbon Monoxide Safety Information
General CO Information
Carbon monoxide (CO) is a colorless, odorless, and tasteless
poison gas that can be fatal when inhaled. CO inhibits the
blood’s capacity to carry oxygen.
Possible Sources
CO can be produced when burning any fossil fuel: gasoline,
propane, natural gas, oil and wood. It can be produced by any
fuel-burning appliance that is malfunctioning, improperly
installed, or not ventilated correctly. Possible sources include
furnaces, gas ranges/stoves, gas clothes dryers, water heaters,
portable fuel burning space heaters, fireplaces, wood-burning
stoves and certain swimming pool heaters. Blocked chimneys or
flues, back drafting and changes in air pressure, corroded or
disconnected vent pipes, and a loose or cracked furnace
exchanger can also cause CO. Vehicles and other combustion
engines running in an attached garage and using a charcoal/gas
grill or hibachi in an enclosed area are all possible sources of CO.
The following conditions can result in transient CO situations:
Excessive spillage or reverse venting of fuel-burning appliances
caused by outdoor ambient conditions such as: Wind direction
and/or velocity, including high gusts of wind, heavy air in the vent
pipes (cold/humid air with extended periods between cycles),
negative pressure differential resulting from the use of exhaust
fans, simultaneous operation of several fuel-burning appliances
competing for limited internal air, vent pipe connections vibrating
loose from clothes dryers, furnaces, or water heaters,
obstructions in, or unconventional, vent pipe designs which can
amplify the above situations, extended operation of unvented
fuel-burning devices (range, oven, fireplace, etc.), temperature
inversions which can trap exhaust gasses near the ground, car
idling in an open or closed attached garage, or near a home.
23
General Maintenance
CO Safety Tips
Every year have the heating system, vents, chimney and flue
inspected and cleaned by a qualified technician. Always install
appliances according to manufacturer’s instructions and adhere
to local building codes. Most appliances should be installed by
professionals and inspected after installation. Regularly examine
vents and chimneys for improper connections, visible rust, or
stains, and check for cracks in furnace heat exchangers. Verify
the color of flame on pilot lights and burners is blue. A yellow or
orange flame is a sign that the fuel is not burning completely.
Teach all household members what the alarm sounds like and
how to respond.
Symptoms of CO Poisoning
Initial carbon monoxide poisoning symptoms are similar to the flu
with no fever and can include dizziness, severe headaches,
nausea, vomiting and disorientation. Everyone is susceptible but
experts agree that unborn babies, pregnant women, senior
citizens and people with heart or respiratory problems are
especially vulnerable. If symptoms of carbon monoxide poisoning
are experienced seek medical attention immediately.
CO poisoning can be determined by a carboxyhemoglobin test.
The following symptoms are related to CARBON MONOXIDE
POISONING and should be discussed with ALL members of the
household:
1. Mild Exposure: Slight headache, nausea,vomiting, fatigue
(often described as “Flu-like” symptoms).
2. Medium Exposure: Severe throbbing headache,
drowsiness, confusion, fast heart rate.
3. Extreme Exposure: Unconsciousness, convulsions,
cardiorespiratory failure, death.
The above levels of exposure relate to healthy adults. Levels
differ for those at high risk. Exposure to high levels of carbon
monoxide can be fatal or cause permanent damage and
disabilities. Many cases of reported carbon monoxide poisoning
indicate that while victims are aware they are not well, they
become so disoriented they are unable to save themselves by
24
Carbon Monoxide Safety Information
either exiting the building, or calling for assistance. Also, young
children and household pets may be the first effected.
Familiarization with the effects of each level is important.
Fire Safety Information
Escape Plan
Familiarize everyone with the sound of the smoke alarm and train
them to leave the home when they hear it. Practice a fire drill at
least every six months, including fire drills at night. Ensure that
small children hear the alarm and wake when it sounds. They
must wake up in order to execute the escape plan. Practice
allows all occupants to test your plan before an emergency. You
may not be able to reach your children. It is important they know
what to do. Know two ways out of every room (door & window)
and identify a meeting place outside the home where everyone
will gather once they have exited the residence. When two
people have reached the meeting place, one should leave to call
911 while the second person stays to account for additional
family members.
Establish a rule that once you’re out, you never reenter
under any circumstance!
Current studies have shown smoke alarms may not awaken all
sleeping individuals, and that it is the responsibility of individuals
in the household that are capable of assisting others to provide
assistance to those who may not be awakened by the alarm
sound, or to those who may be incapable of safely evacuating
the area unassisted.
Fire Prevention
Never smoke in bed, or leave cooking food unattended. Teach
children never to play with matches or lighters!
Train everyone in the home to recognize the alarm pattern, voice
message warning and to leave the home using their escape plan
when it’s heard.
Know how to do “Stop, Drop and Roll” if clothes catch on fire,
and how to crawl low under smoke. Install and maintain fire
extinguishers on every level of the home and in the kitchen,
basement and garage. Know how to use a fire extinguisher prior
to an emergency. Second level and higher occupied rooms with
windows, should have an escape ladder.
25
Carbon Monoxide Safety Information
Industry Safety Standards
NFPA (National Fire Protection Association)
For your information, the National Fire Protection Association’s
Standard 72, reads as follows:
Smoke Detection. Where required by applicable laws, codes, or
standards for the specified occupancy, approved single- and
multiple-station smoke alarms shall be installed as follows: (1) In
all sleeping rooms. (2) Outside of each separate sleeping area, in
immediate vicinity of the sleeping rooms. (3) On each level of the
dwelling unit, including basements Exception: In existing oneand two-family dwelling units, approved smoke alarms powered
by batteries are permitted.
Smoke Detection - Are More Smoke Alarms Desirable? The
required number of smoke alarms might not provide reliable early
warning protection for those areas separated by a door from the
areas protected by the required smoke alarms. For this reason, it
is recommended that the householder consider the use of
additional smoke alarms for those areas for increased protection.
The additional areas include the basement, bedrooms, dining
room, furnace room, utility room, and hallways not protected by
the required smoke alarms. The installation of smoke alarms in
kitchens, attics (finished or unfinished), or garages is not normally
recommended, as these locations occasionally experience
conditions that can result in improper operation.
California State Fire Marshall
Early warning fire detection is best achieved by the installation of
fire detection equipment in all rooms and areas of the household
as follows: A smoke alarm installed in each separate sleeping
area (in the vicinity, but outside the bedrooms), heat or smoke
detectors in the living rooms, dining rooms, bedrooms, kitchens,
hallways, attics, furnace rooms, closets, utility and storage rooms,
basements and attached garages.
Consumer Product Safety Commission
The Consumer Product Safety Commission (CPSC) recommends
26
Fire Safety Information
the use of at least one CO
Alarm per household, located
near the sleeping area.
NRC
Ionization type smoke alarms
use a very small amount of a
radioactive element in the
sensing chamber to enable
detection of visible and
invisible combustion products.
The radioactive element is
safely contained in the
chamber and requires no
adjustments or maintenance.
This smoke alarm meets or
exceeds
all
government
standards. It is manufactured
and distributed under license
from the U.S. Nuclear Regulatory Commission.
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help
Limited Warranty
27
Industry Safety Standards
TEN YEAR LIMITED WARRANTY
KIDDE warrants that the enclosed alarm will be free from defects
in material and workmanship or design under normal use and
service for a period of ten years from the date of purchase. The
obligation of KIDDE under this warranty is limited to repairing or
replacing the alarm or any part which we find to be defective in
material, workmanship or design, free of charge, upon sending
the alarm with proof of date of purchase, postage and return
postage prepaid, to Warranty Service Department, KIDDE, 1016
Corporate Park Dr., Mebane, NC 27302.
This warranty shall not apply to the alarm if it has been damaged,
modified, abused or altered after the date of purchase or if it fails
to operate due to improper maintenance or inadequate AC or
DC power. Any implied warranties arising out of this sale,
including but not limited to the implied warranties of
description,merchantability and fitness for a particular purpose,
are limited in duration to the above warranty period. In no event
shall the Manufacturer be liable for loss of use of this product or
for any indirect, special, incidental or consequential damages, or
costs, or expenses incurred by the consumer or any other user of
this product, whether due to a breach of contract, negligence,
strict liability in tort or otherwise. The Manufacturer shall have
no liability for any personal injury, property damage or any
special, incidental, contingent or consequential damage of any
kind resulting from gas leakage, fire or explosion.
Since some states do not allow limitations of the duration of an
implied warranty or do not allow the exclusion or limitation of
incidental or consequential damages, the above limitations or
exclusions may not apply to you. While this warranty gives you
specific legal rights, you may also have other rights which vary
from state to state.
Also, KIDDE makes no warranty, express or implied, written or
oral, including that of merchantability or fitness for any particular
purpose, with respect to the battery.
The above warranty may not be altered except in writing signed
by both parties hereto.
Your Kidde Combination Smoke & CO Alarm is not a substitute
28
Warranty and Service Information
for property, fire, disability, life or other insurance of any kind.
Appropriate insurance coverage is your responsibility. Consult
your insurance agent.
Removal of the front cover will void the warranty.
This alarm is not intended to alert hearing impaired
individuals or individuals with mild to severe hearing loss.
During the specified warranty period Kidde Products will repair or
replace, at its discretion any defective Kidde Combination Smoke
& CO Alarms that are returned in a postage paid package to the
following address: Kidde Products Attn: Warranty Returns, 1016
Corporate Park Dr., Mebane, NC 27302, USA. Please include
your name, address and phone number along with a brief
description of what is wrong with the unit. For further assistance
please call our toll free Product Support Line at 1-800-880-6788.
Damage from neglect, abuse or failure to adhere to any of the
enclosed instructions will result in termination of the warranty,
and the unit will not be replaced or repaired.
This user guide and the products described herein are
copyrighted, with all rights reserved. Under these copyright laws,
no part of this user guide may be copied for use without the
written consent of Kidde. If you require further information
please contact out Product Support Line at 1-800-880-6788 or
write us at: Kidde Products, 1016 Corporate Park Dr., Mebane,
NC 27302.
Our internet address is www.kidde.com.
29
QUESTIONS OR FOR MORE INFORMATION
Call our Product Support Line at 1-800-880-6788 or contact
us at our website at www.kidde.com
Kidde 1016 Corporate Park Drive, Mebane, NC 27302
Custom Assembled in China with U.S. and Foreign Components
Was this manual useful for you? yes no
Thank you for your participation!