CX-Series CCTV/DATA Coax Protector __ CX- - -

CX-Series CCTV/DATA Coax Protector __ CX- - -
CCTV/DATA Coax Protector
CX-Series
FEATURES
Three-Stage Series Hybrid
Sneak / Fault Current Protection
Low Insertion Loss
Shielded Case
Stand Alone Mounting Plate included or can
be used in conjunction with EDCO part #(s)
RM4POS or RMRM
Rack Mount Option available as RM CX
The CX-Series is a coax line protector that utilizes a three-stage hybrid design topology. These units address
over-voltage transients with gas discharge and silicon avalanche devices. In addition, sneak and fault currents
are mitigated with PTC technology, which consists of resettable fuses. The PTC’s increase resistance several
orders of magnitude when overcurrents exceed safe levels. A normal state resumes when overcurrents are
removed. The ability to self-restore in this manner significantly increases suppressor performance and
survivability.
SPECIFICATIONS
ORDERING INFORMATION
__ CXFrequency Range:
Insertion Loss:
Characteristic Impedance:
Connectors:
Clamping Voltage:
Peak Surge Current:
Response Time:
Temperature:
UL Listed:
0 to 20MHz
0.1db @10MHz
(typical)
50 / 75 ’s
BNC-Type
See Chart
20kA @ 8x20 s
<1ns
-40 C to +85 C
UL 497B
-
-
(RM)
Rack Mount
Option
Clamp Voltage
6 volts…06
12 volts…12
15 volts…15
18 volts…18
*75 volts…75
*90 volts…90
*Not UL listed
Connectors
BNC type…BNC
F type….. F
Listed
497B
(empty)
Standard
(I )
Isolated
Shield from
Ground
X…50
Y…75
NEED HELP? Call 1-800-648-4076
© EDCO 2000
1805 N.E. 19th Avenue
(352) 732-3029
Page 1 of 2
P.O. Box 1778
FAX (352) 867-1237
E-mail us at: edco@edcosurge.com
Ocala, Florida 34478
Sales: 1-800-648-4076
Internet: http://www.edcosurge.com
81035
’s
’s
CCTV/DATA Coax Protector
CX-Series
CX SERIES: HEAD-END EQUIPMENT PROTECTION
Step 1
Make sure that specific model number chosen features the appropriate connector style and
impedance matching (50 or 75 ohm).
Step 2.
A. Connect the CX SERIES in line with the coaxial cable. The side labeled “EQUIP” should be
connected to the adjacent head-end equipment.
B. Connect incoming coaxial cable to the side of the CX-SERIES labeled “CABLE”.
C. Connect a ground wire (10-12 AWG) between the CX-SERIES ground terminal and the AC
power ground of head-end equipment. Keep this wire as short and straight as possible.
CX SERIES: CAMERA END PROTECTION
Step 3.
A. Connect the CX-SERIES in line with the coaxial cable. The side labeled “EQUIP” should be
connected to the adjacent camera.
B. Connect incoming coaxial cable to the side of the CX-SERIES labeled “CABLE”.
C. Connect a ground wire (10-12 AWG) between the CX-SERIES ground terminal and either
the AC power ground or equipment building ground at the camera location. Keep this wire as
short and straight as possible.
cx
HEAD-END
EQUIPMENT
cx
(Keep ground wire
as short as possible)
CAMERA
(Keep ground wire
as short as possible)
To AC Power Ground
Or Building Ground
To AC Power Ground
Read and Understand These Instructions:
CATV-145A
Step 1. Follow step 2 of CX-SERIES above.
These protectors are intended for indoor use on communication loop circuits
which have been isolated from the Public Switch Telephone Network.
The communication loop circuits shall not be exposed to accidental contact
with the electric light or power conductors. The protectors shall be installed per
the applicable requirements of the National Electric Code, ANSI/NFPA 70.
NEED HELP? Call 1-800-648-4076
© EDCO 2000
1805 N.E. 19th Avenue
(352) 732-3029
Page 2 of 2
P.O. Box 1778
FAX (352) 867-1237
E-mail us at: edco@edcosurge.com
Ocala, Florida 34478
Sales: 1-800-648-4076
Internet: http://www.edcosurge.com
81035