bravo4 inis [UL] en 29000112 r003.p65

bravo4 inis [UL] en 29000112 r003.p65
Transient immunity ................................ 2.4kV @ 1.2 joules
White light immunity ................. 20,000 Lux at the detector
Series
Quad Motion Detector
INSTALLATION INSTRUCTIONS
FEATURES
• QUAD element low noise sensor
• Four interchangeable lenses
• High level static protection
• High level transient protection
• High level white light immunity
• Excellent RF immunity
• Temperature compensation
• Energy analysis circuit
• Dual channel processing
• LED on / off jumper
• Vertical adjustment
• SMD construction
• Super quiet operation
• Wall / corner mounting
• Small size
• Blends with any decor
INTRODUCTION
The Bravo4 is a general purpose quad PIR designed to provide
reliable motion detection for large residential and commercial
applications.
Exceptional design care and factory testing ensure years of trouble
free performance. Immunity against false alarms from RF, static,
electrical transient and white light are all designed in features.
Energy analysis, dual channel signal processing, temperature
compensation and large multi-beam lens design means the human
target will not slip by unnoticed even on a hot summer day.
Four interchangeable lenses, wall or corner mounting and vertical
adjustment provide application versatility, and your client will
appreciate the small size and elegant simplicity of the case design.
SPECIFICATIONS
Operating voltage .................................... 9.5VDC-14.5VDC
Coverage angle (wall-to-wall lens) ................ 90° minimum
Vertical adjustment ........................ +5° to -10° (see charts)
Mounting heights ............................. 6' to 10' (nominal 7.5')
2m to 3m (nominal 2.3m)
6 ft
1.8 m
4' to 5' (pet alley only)
1.2m to 1.5m (pet alley only)
BEAM PATTERN CHART
ILLUSTRATES THE CENTRE
LINE OF EACH BEAM PAIR
NOTE: White light and RF Immunity not verified by UL.
CENTRE
LINE
COVERAGE
Wall to Wall lens (BV-L1) 50' L × 60' W (16m × 18m)
Corridor lens (BV-L2)
60' L × 5' W (18m × 1.5m)
Curtain lens (BV-L3)
50' L × 4.4' W (16m × 1.3m)
Pet Alley lens (BV-L4)
50' L × 60' W (16m ×18m)
60 ft
18.3 m
SIDE VIEW
60 ft
18.3 m
DIMENSIONS
3.5"H × 2.5"W × 1.87"D (89mmH × 64mmW × 48mmD)
CURTAIN LENS
SIDE VIEW
COLOUR
TOP VIEW
White case with light gray lens
SHIPPING WEIGHT
50 ft
15.2 m
6 oz. (190 g)
50 ft
15.2 m
MODELS
BV-400UL
Form A alarm contact
BV-401UL
Form A alarm contact & tamper switch
BV-402UL
Form C alarm contact & tamper switch
WALL-TO-WALL LENS
TOP VIEW
L2
30 ft
9.1 m
L3
15 ft
4.6 m
Standby current ......................................................... 18mA
Current in alarm ......................................................... 16mA
MOUNTING
To open the case, use a small flat blade screwdriver and gently
push in the tab at the bottom of the case and pull the cover
straight out at the bottom. Loosen the PCB screw, and push the
board up as far as it will go. Using a small screwdriver, remove
the appropriate knockouts for the mounting screws. Remove
the left and/or right wiring entrance knockouts located at the top
of the backplate. Mount the backplate using the appropriate
mounting screws (not supplied).
MOUNTING HEIGHT CHART
L4
Contact rating (alarm & tamper) ............. 100mA @ 24VDC
0 ft
0 m
Alarm contact resistor in common .................. 10 ohm ¼W
Operating temperature .................................... 0°C to 49°C
(32°F to 120°F)
15 ft
4.6 m
Storage temperature .................................... -40°C to 60°C
(-40°F to 140°F)
30 ft
9.1 m
Operating humidity ........... 5% to 95% RH non-condensing
50 ft
15.2 m
Storage humidity ............... up to 99% RH non condensing
Static immunity ............................................................ 25kV
TOP VIEW
Walk detection speed ............. 0.5' to 10'/s (0.15m - 3m/s)
Supply voltage ripple ............................. 3.0V pp @ 12VDC
RF immunity .............. 20 V/m over range 0.01MHz-1.2GHz
CORRIDOR LENS
SIDE VIEW
50 ft
15.2 m
HEIGHT
ft / m
SETTING FOR FULL RANGE
WALL/WALL CORRIDOR
CURTAIN
10’ / 3 m
0.00
-0.25
0.00
8’ / 2.4 m
+0.50
+0.25
0.00
7’ / 2.1 m
+0.75
+0.25
0.00
6’ / 1.8 m
+1.00
+0.50
0.00
PET ALLEY
5’ / 1.5 m
0.00
4’ / 1.2 m
0.00
LOCATING THE DETECTOR
WALK TESTING
Select a detector location that will provide the coverage
required keeping in mind the following potential problems
Limited Warranty
Reflective Surfaces Do not aim the detector at reflective
surfaces such as mirrors or windows as this may distort the
coverage pattern or reflect sunlight directly onto the detector.
Once the detector has been set up, walk test the entire area
where coverage is desired. Should the coverage be incomplete,
re-adjust or relocate the detector to obtain full coverage. Once
coverage is as required, the alarm LED may be disabled by
setting J1 to OFF.
Air Flow Avoid locations that are subject to direct high air flow
such as near an air duct outlet.
IMPORTANT NOTE: Upon installation, the unit should be
thoroughly tested to verify proper operation.
Moisture Do not locate the detector near sources of steam or
oil.
The detector should be walk tested weekly by the end user and
yearly by the installer.
Sun Do not aim the detector such that it will receive direct or
reflected (mirror) sunlight,
Pets If there are pets on the premises, use the pet alley lens.
Obstructions Do not limit the coverage by large objects
within the detection area such as plants or filing cabinets.
VERTICAL ADJUSTMENT
Using the Mounting Height Chart, set the vertical adjustment to
obtain the desired coverage. Ensure that the PCB retaining
screw is tightened just enough to prevent board movement.
DM-C and DM-W
Detector Mounting Brackets
Use the optional DM-W Wall Mount and DM-C Ceiling Mount
brackets to solve difficult placement problems. The DM-W and
DM-C mount to either the wall or ceiling and allow for full vertical
and horizontal positioning of the motion detector - the detector
can be tilted up or down and rotated through 90° to obtain the
best position for optimal coverage. The Bravo PIR has been
designed to be fully compatible with the DM-W and DM-C
brackets. Contact your DSC distributor for more information.
JUMPER J1 will enable/disable the alarm LED. If J1 is OFF,
the LED will not operate on alarm. If J1 is ON the LED will
operate on alarm.
WIRING KNOCKOUTS
NOTE: The corridor lens should not be used in corridors that
are less then 5' in width and the installation should be carefully
checked to ensure that the beams are aimed directly down the
centre of the corridor.
WIRING
NO NC C
LED
TAMPER
CONTACT
100 mA
24 VDC
POWER
20 mA
12 VDC
LED NO NC C
J1
Contacts shown with power applied
and no alarm
NOTE: This unit is UL Listed
and should be connected to a
listed control unit or power
supply providing at least 4
hours of standby power.
J1 ON = LED ON
J1 OFF = LED OFF
RELAY
TAMP 12V GND
ALARM
CONTACTS
100 mA
24 VDC
The foregoing warranty shall apply only to the original purchase, and is and shall
be in lieu of any and all other warranties, whether expressed or implied and of all
other obligations or liabilities on the part of Digital Security Controls Ltd. Digital
Security Controls Ltd. neither assumes, nor authorizes any other person purporting
to act on its behalf to modify or to change this warranty, nor to assume for it any other
warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd. be liable for any direct, indirect or
consequential damages, loss of anticipated profits, loss of time or any other losses
incurred by the buyer in connection with the purchase, installation or operation or
failure of this product.
Motion detectors can only detect motion within the designated areas as shown in
their respective installation instructions. They cannot discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area
protection. They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion
which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass
doors or windows. Any type of tampering whether intentional or unintentional
such as masking, painting, or spraying of any material on the lenses, mirrors,
windows or any other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the ambient temperature rises near or
above body temperature or if there are intentional or unintentional sources of heat
in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on.
Warning: Digital Security Controls Ltd. recommends that the entire system be
completely tested on a regular basis. However, despite frequent testing, and due
to, but not limited to, criminal tampering or electrical disruption, it is possible for
this product to fail to perform as expected.
Important Information: Changes or modifications not expressly approved by
Digital Security Controls Ltd. could void the user’s authority to operate this
equipment.
LOOSEN SCREW FOR
VERTICAL ADJUSTMENT
TAMP 12V GND
Digital Security Controls Ltd. warrants that for a period of 12 months from the date
of purchase, the product shall be free of defects in materials and workmanship under
normal use and that in fulfilment of any breach of such warranty, Digital Security
Controls Ltd. shall, at its option, repair or replace the defective equipment upon
return of the equipment to its repair depot. This warranty applies only to defects in
parts and workmanship and not to damage incurred in shipping or handling, or
damage due to causes beyond the control of Digital Security Controls Ltd. such as
lightning, excessive voltage, mechanical shock, water damage, or damage arising
out of abuse, alteration or improper application of the equipment.
PIR SENSOR
TAMPER
SWITCH
+1
0
-1
-2
10Ω
0.25W
CORNER MOUNT
KNOCKOUTS
VERTICAL
ADJUSTMENT
SCALE
WALL MOUNT
KNOCKOUTS
CHANGING LENSES
The Bravo4 is supplied with the “wall-to-wall” lens. To
change the lens, release the top tab and pull the lens holder
out. This action releases the lens. Insert the lens with the
GROOVES FACING INWARD. The bottom of the lens is
indicated by two triangular indentations. Ensure that the lens
is centred left to right then reinstall the lens holder. The lens
holder will snap into place sealing the lens into position.
©2002 Digital Security Controls Ltd.
Toronto, Canada • www.dsc.com • 1-800-387-3630
Printed in Canada 29000112 R003
Direct all comments and suggestions concerning
DSC publications to pubs@dscltd.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising