Fluid Monobloc
Important Technical Data
Minimum operating pressure 0.5 bar
Maximum operating pressure 5.5 bar*
Whilst assembling this product take care not to accidentally loosen any
screwed assemblies. PTFE tape can be used to ensure watertight joins
on threaded connections, do not over tighten connections or allow
pipes to be twisted or folded.
Maximum hot water temperature 70°C*
Recommended hot water temperature 46°C
The installation should be periodically checked for damage, if the
property is left unattended for a prolonged period we recommend
isolating water supplies.
Note: If these temperatures or pressures are exceeded,
even for short periods, damage can result. In these
instances a thermostatic mixing or pressure reducing
valve should be installed.
Hot and cold supply pressures should be as closely
balanced as possible for best results. Supply pipes
should maintain the maximum diameter until
immediately before the fitting. The differential between
the hot and cold water supply temperatures should be
sufficient to allow correct mixing function.
All Abode taps are either WRAS approved or
manufactured in accordance with recognised European
standards. Please ensure that your Abode product is
fitted in accordance with Local Water Byelaws. Where
hot and cold water mix within any product, then suitable
non return valves should be installed to the hot and cold
supplies to prevent backflow.
Fluid Monobloc
Abode is a registered trademark of Abode Home Products Limited. All
errors and omissions excepted.
Manufacturers Product Reference
©Abode
4/2016
5 Year warranty
Terms and Conditions
In the unlikely event that you should experience any
defect in the materials or workmanship of your new
Abode mixer within 5 years of purchase, the
purchaser’s sole remedy shall be the replacement
(at the manufacturer’s discretion) of all or any part of
the product that is defective. All working parts and
valves are guaranteed for a period of 5 years from
purchase. Decorative surface finishes and O-rings
are guaranteed for 1 year from the date of purchase
provided that our advice concerning care has been
observed and no scouring agents have been used.
This is provided that the mixer or tap has been used
for normal domestic purposes and that the care,
installation and maintenance instructions have been
observed. The warranty extends to the original
purchaser only.
Marks, scuffs and scratches caused by improper
installation or accidental damage are not covered by
this guarantee. Neither are shade variations or any
damage or defect caused by incorrect installation or
abuse of the fitting.
As we are continuously improving and developing
our range of products, finishes & colours, in the
event of a valid claim, we may not be able to provide
an identical replacement for the defective product
throughout the guarantee period. Where an identical
product is no longer available, we will supply the
nearest equivalent from our then current product
range. In assessing your claim, we must be given
the opportunity to inspect the product as installed
prior to removal. Any product returns must be
packaged as received and complete.
No other warranties, express or implied, are made,
including merchantability or fitness for a particular
purpose. Under no circumstances shall the
manufacturer be liable for any loss or damage
arising from the purchase, use or inability to use this
product, or for any special, indirect, incidental or
consequential damages. No liability is accepted for
consequential damage to other household fixtures,
fittings or furnishings arising from this claim, even if
attached to the product. No installer, dealer, agent or
employee of Abode Home Products Limited has the
authority to modify the obligations or limitations of
this warranty.
Care Instructions for your Kitchen Sink Mixer
Abode Home Products Limited, Unit L, Zenith Park, Whaley Road, Barnsley, S75 1HT.
Tel: 01226 283434 Fax: 01226 282434 www.abode.eu
All errors and omissions excepted.
To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp
cloth. A solution of warm water and a mild liquid detergent may be used where necessary, and then the
fitting rinsed thoroughly and wiped dry. Any other cleaning action will invalidate your warranty.
If the mixertap has a diffuser it should be unscrewed and cleaned periodically in warm water.
Abrasive cleaners, scouring cleaners and acidic cleaners must not be used under any circumstances. Avoid contact
with all solvents (including chlorinated solvents, ketones or acetones as these may result in surface deterioration or
etching). Also avoid contact with any harsh household chemicals such as oven cleaners, drain cleaners, rust
removers, paint strippers and toilet bowl cleaners, bar keepers friend or Brasso.
Please leave these instructions for your customer.
Parts and Contents
Installation
Key
Description
Qty
A
Mixertap body
1
B
Upper seal
1
C
Fixing stud
1
D
White triangular stabiliser
(for stainless steel sinks only)
1
E
Lower Gasket
1
F
Metal horseshoe
1
1.
Screw the fixing stud (C) into the base of the tap (A).
2.
Screw the tail pipes (H&I) into the base of the tap (A).
3.
Pass the upper seal (B) over the fixing stud (C) and tail pipes (H&I), locate the upper seal (B) centrally on
the base of the mixertap (A).
4.
Place the mixertap (A) onto the sink or worktop and pass the tail pipes (H&I) and fixing stud (C) through
the taphole. With the tap in place check that the tails (H&I) meet the hot and cold water feeds. If further
adjustment to the plumbing is required do this now. Note: do not twist, stretch or kink the tail pipes.
5.
If fitting the tap to a stainless steel sink the white triangular stabiliser (D) can be placed where shown to
help to stabilise the weight of the tap. Otherwise stabiliser (D) can be ignored.
6.
Pass the lower gasket (E) and then metal horseshoe (F) over fixing stud (C) and around tail pipes (H&I).
7.
Fasten the fixing nut (G) securely onto the fixing stud (C) fixing the tap into its correct location.
8.
Connect the hot and cold water tail pipes (H&I) to the water supply pipes using 15mm compression
fittings or similar.
After installation
G
Fixing nut
1
H
Cold water tail pipe
(With integral NRV)
1
Once you have visually checked the installation of the new tap and all connections, ensure that all other fittings are
closed except the new tap which should be left open.
Turn on your water heating system and ensure that your mains stopcock is open. Reconnect both the hot and cold
water supplies to this fitting.
Check the function of flow and function of hot, cold and mixed water.
I
Hot water tail pipe
(With integral NRV)
1
Turn off the tap and check carefully for any leaks around all connections on the fitting and adjoining plumbing.
If possible return to the installation after a longer period to double check for slower leaks.
Installation Instructions:
Preparation
All parts should be removed from their packaging and inspected for any transport damage and completeness prior to
installation; you should read these instructions throughout before commencing installation. We do not accept responsibility for
problems that may occur through improper installation. Always ensure you have sufficient hot and cold water pressure
available to allow correct function before specifying or installing this product.
You should ensure that the product will both fit into the depth of the mounting surface available and reach the required outlet
position before installation.
Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any
remaining solder, swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or
damage to the workings of the mixertap.
We strongly recommend installing particle filters and isolation valves to both the hot and cold feed pipes in an accessible
position. This will help to prevent premature failure of the valves and ease any future maintenance.
Shut off your water heating system and ensure that your mains stopcock is closed. Ensure both the hot and cold water
supplies are isolated before commencing installation.
This mixertap requires a 35mm∅ tap hole, if replacing an existing tap, remove the tap & clean the end of the feed pipes using
wire wool the tap hole area should be free from dirt and sealant. Loosely position the tap and tail pipes to check if any
alteration to the existing pipework is required, if this is the case do this now.
If pressure testing equipment is available check the installation to the maximum recommended pressure.
Clean the tap to remove any marks created during installation as instructed then place a bag over the product to
protect the tap until it is ready for use.