Our Multi-Function Speech Unit reproduces high quality announcements from actual
voice recordings and drives our display unit products via our 4-wire network.
The Multi-Function Speech Unit is of single circuit board construction and requires no
additional encoder boards. It is usually installed in the lift control panel, where it
interfaces to the appropriate lift control signals. The unit intelligently interprets these
signals and generates corresponding voice announcements whilst simultaneously
transmitting control information to any display or ancillary units connected onto our
serial data network.
ONLY ONE MULTI-FUNCTION SPEECH UNIT IS REQUIRED PER LIFT.
Standard Phrase
Library
PLEASE SEE THE MALE (APPENDIX A) & FEMALE (APPENDIX B) PHRASE
LIBRARY LISTS AT THE BACK OF THIS CATALOGUE
Announcement
Capabilities
Maximum playback time: 2 minutes of continuous speech
Maximum number of announcements: limited only by playback time
Maximum individual phrase length: 2 minutes
Standard Features
Male or Female voice (replace 'g' in part number with 'M' - male,'F' - female)
16 opto-isolated control signal inputs
Choice of control signal voltages (specify when ordering, see Appendix C)
Custom allocation of control signal inputs (see Appendix D)
Electrical Detail
Continuous power supply:12vdc to 37vdc or 12vac to 24vac
Power supply consumption:360mA @ 12vdc
General
Unit supplied loose complete with a loudspeaker.
Optional Items
Input expansion units (additional control signal inputs: 8 or 16-way)
DIN Rail mounting kit
Inductive Loop Driver
Hush mode (secondary volume control, selected via a control signal input)
Increased playback time
Serial data input (RS-485) for networking
Custom recordings (full studio recordings & digitisation service)
Digitisation service (conversion of your recordings to MFSP24 format)
Stainless steel faceplate & mild steel backbox for loudspeaker
Battery back-up systems
COPYRIGHT 2003 STENTORGATE LTD
MFSP24/0311
1.0.1
BACK
HOME
Speech Unit
RMVU24-g
4-Wire Network
(Remote Network Speech Unit)
Description
Our remote speech unit (RMVU24-g) reproduces high quality announcements from actual voice
recordings.
Any number of remote speech units can be connected onto our 4-wire network, along with any of our
indicator products, at any location throughout a building.
The unit announces in response to commands serially transmitted from one of our control units,
responding to signals in the lift controller, and from directly wired signals connected to the remote
speech unit itself. This design enables signals located locally to the remote speech unit, landing push
signals for example, and control panel signals to be used as stimulus for announcements.
The flexibility of our remote speech unit’s design allows for even greater disability access provision;
up
and down landing call acceptance can be announced, lift status messages can be announced
when a landing call button is pressed, for example: ‘Lift out of service’ (announced at any floor
when a landing button is pressed) and ‘Lift doors are open’ (announced only at the arrival floor when
a landing button is pressed). The unit can even be used as an arrival/departure direction announcer
giving voice or tonal indication of next travel direction.
Standard
Phrases
PLEASE SEE THE MALE (APPENDIX A) AND FEMALE (APPENDIX B) PHRASE LIBRARY LISTS
AT THE BACK OF THIS CATALOGUE
Announcement Maximum playback time & phrase length: 2 minutes of continuous speech
Maximum number of announcements: limited only by playback time
Capabilities
Standard
Features
Male or Female voice (replace ‘g’ in part number with ‘M’-male, ‘F’-female)
4 opto-isolated control signal inputs
Electrical
Detail
Continuous power supply: 12vdc to 37vdc or 12vac to 24vac
Power supply consumption: 200mA @12vdc
General
Unit supplied loose with a loudspeaker
Optional Items Custom recordings (full studio recordings & digitisation service)
Digitisation service (conversion of your recordings to RMVU24 format)
Stainless steel faceplate & mild steel backbox
THIS UNIT CONNECTS ONTO OUR 4-WIRE NETWORK; THEREFORE, A CONTROL UNIT MUST BE ORDERED FOR EACH
LIFT
COPYRIGHT 2000 STENTORGATE LTD
RMVU/2010
1.0.2
BACK
HOME
Inductive Loop Driver
INDUCTIVE LOOP DRIVER
100V LINE
MATCHING
TRANSFORMER
N35A001F
LINE
8 OHMS
10 W
110/240vac
POWER
INPUT
POWER
INPUT
OUTPUT
CHANNEL.B
POWER
INPUT
FUSE
POWER
VOLTAGE
SELECTOR
VOLUME
CHANNEL.B
LOUDSPEAKER
INDUCTIVE LOOP
DRIVER
AUX.LINE
INPUT
D1
D2
D1
DATA
OUT
D2
OUTPUT
CHANNEL.A
VOLUME
CHANNEL.A
LINE
INPUT
LOUDSPEAKER
INDUCTIVE
LOOP
LIFT CAR
FUSE 1
A
FUSE 2
A
POWER OUT
1A 2A
Description
1B 2B
POWER
IN
1 2
Our inductive loop driver receives 100v line amplified voice signals, generated
by our voice unit, and plays the sound back through two separate channels;
one for a loudspeaker and one for an inductive loop.
Both voice output channels are independently volume controllable allowing the
installer to select larger amounts of power output (up to 6W) for the inductive
loop whilst trimming the loudspeaker output to acceptable levels.
The standard wire loop supplied with the unit must be mounted around the
perimeter of the lift car; ideally, either in the ceiling or in the floor of the lift.
The loop generates an electric field that can be obscured by large amount of
steel, so care must be taken when locating the loop.
Standard Features
Single input channel, two output channels (independently controllable)
Selectable power supply voltage (240vac or 110vac – fused on PCB)
Maximum 6W audio output power
Electrical Detail
Continuous power supply:240vac or 110vac selectable
Max. Power supply consumption:12W
General
Unit supplied mounted in a steel enclosure with a loose wire loop and line
transformer for speech unit output conversion.
Optional Items
PCB mounted loop for proximity loop applications
Emergency telephone & voice unit compatible driver
Auxiliary input channel (for other audio source input)
24v dc power supply option
Inductive loop identifier engraved faceplate
OPYRIGHT 2002 STENTORGATE LTD
INDLOOP/0212
1.0.3
BACK
HOME
Appendix B
Female Phrase List - Page 1 of 2
Relevant to the following parts:
MFSP24-g & RMVU-g
1.
DOOR OPERATION ANNOUNCEMENTS
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
1.13
1.14
2.
3.5
3.6
3.7
3.8
4.3
5.
7.17
7.18
8.
LIFT OVERLOADED, PLEASE REDUCE THE LOAD
PLEASE REDUCE THE LOADLIFT OVERLOADED, WILL
THE LAST PASSENGER PLEASE USE THE NEXT LIFT
LIFT OVERLOADED. PLEASE REDUCE WEIGHT IN LIFT
8.15
9.
5.3
5.4
5.5
5.6
5.7
LIFT OUT OF SERVICE
THIS LIFT IS NOW OUT OF SERVICE, PLEASE EXIT THE
LIFT – THANK YOU
THIS LIFT IS NOT IN SERVICE
THIS LIFT IS NOW OUT OF SERVICE PLEASE LEAVE
THIS LIFT IS BEING TAKEN OUT OF SERVICE, PLEASE
LEAVE NOW.
DO NOT ENTER THIS LIFT
PLEASE USE ANOTHER LIFT
ALARM ANNOUNCEMENTS
6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9
DO NOT PANIC. PRESS ALARM BUTTON FOR 5
SECONDS TO ACTIVATE IN-LIFT AUTOMATIC
TELEPHONE
PLEASE STAY CALM
PLEASE STAY CALM, HELP IS COMING
HELP HAS BEEN CALLED
SECURITY HAS BEEN CALLED
ALARM CALL ACKNOWLEDGED
LIFT ALARM ACTIVATED, PLEASE AWAIT ASSISSTANCE
ALARM RECEIVED, LIFT TELEPHONE TO RIGHT HAND
SIDE OF DOORS
ALARM RECEIVED. LIFT TELEPHONE TO LEFT HAND
SIDE OF DOORS
LIFT APPROACHING THE ....
EXIT TO THE LEFT
EXIT TO THE RIGHT
VACATE THE LIFT AT THE ......
THIS FLOOR FOR .....
NEXT FLOOR
TURN LEFT FOR ....
TURN RIGHT FOR ....
LIFT ARRIVING AT….
PLEASE VACATE THE LIFT
PLEASE EVACUATE THE CAR
PLEASE EVACUATE AT THE NEXT FLOOR
VACATE THE LIFT AT THE NEXT FLOOR
PLEASE LEAVE THE BUILDING BY THE NEAREST
AVAILABLE EXIT
PLEASE ALLOW PRIORITY ACCESS FOR WHEELCHAIR
USERS
LANDING SPECIFIC ANNOUNCEMENTS
9.1
9.2
9.3
9.4
9.5
9.6
10.
LIFT UNDER ATTENDANT'S CONTROL
LIFT UNDER MAINTENANCE CONTROL
LIFT UNDER ENGINEER'S CONTROL
LIFT UNDER GOODS CONTROL
LIFT UNDER PRIORITY CONTROL
LIFT UNDER MEDICAL CONTROL
LIFT ON PRIORITY CONTROL
LIFT ON SERVICE CONTROL
EVACUATION CONTROL
LIFT UNDER EVACUATION CONTROL
EMERGENCY CONTROL
LIFT UNDER CAR PREFERENCE CONTROL
LIFT ON OVERRIDE CONTROL
OVERRIDE CONTROL
LIFT RETURNING TO THE …… FLOOR ON OVERRIDE
CONTROL
EXTENDED DOOR TIME ACTIVATED. PLEASE PRESS
DOOR CLOSE OR FLOOR BUTTON TO CANCEL
LIFT REQUIRED FOR EMERGENCY SERVICE. PLEASE
EXIT AT THE NEXT LEVEL
LIFT UNDERGOING MAINTENANCE
ARRIVAL ANNOUNCEMENTS
8.1
8.2
8.3
8.4
8.5
8.6
8.7
8.8
8.9
8.10
8.11
8.12
8.13
8.14
LIFT UNDER FIREMAN'S CONTROL
FIRE SERVICE ONLY
LIFT RETURNING TO THE FIRE SERVICE FLOOR
LIFT RETURNING TO THE ....... UNDER FIREMANS
CONTROL
FIRE ALARM, LIFT RETURNING TO THE..
FIRE ALARM ACTIVATED. LIFT RETURNING TO EXIT
FLOOR. PLEASE LEAVE BY NEAREST AVAILABLE EXIT
THIS LIFT IS ON FIREMANS CONTROL. PLEASE DO NOT
USE IT
LIFT ON FIREFIGHTING CONTROL
OUT OF SERVICE ANNOUNCEMENTS
5.1
5.2
6.
7.16
OVERLOAD MESSAGES
4.1
4.2
SPECIAL SERVICE ANNOUNCEMENTS
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.10
7.11
7.12
7.13
7.14
7.15
LIFT GOING UP
LIFT GOING DOWN
NEXT LIFT UP
NEXT LIFT DOWN
THIS LIFT IS GOING UP
THIS LIFT IS GOING DOWN
LIFT TRAVELLING DOWN
LIFT TRAVELLING UP
FIRE SERVICE ANNOUNCEMENTS
3.1
3.2
3.3
3.4
4.
7.
DIRECTION ANNOUNCEMENTS
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
3.
DOORS CLOSING
DOORS OPENING
REAR DOORS OPENING
REAR DOORS CLOSING
FRONT DOORS OPENING
FRONT DOORS CLOSING
PLEASE CLOSE THE GATES
STAND CLEAR OF THE DOORS
MIND THE DOORS
PLEASE DO NOT OBSTRUCT THE DOORS
DOORS ABOUT TO CLOSE
REMOVE OBSTRUCTION FROM THE DOORS
PLEASE REMOVE OBSTRUCTION FROM THE DOORS
PLEASE CLOSE BOTH LANDING AND CAR GATES
UP CALL ACCEPTED
DOWN CALL ACCEPTED
CALL ACCEPTED
THIS CALL HAS BEEN ACCEPTED. THE LIFT WILL
ARRIVE SHORTLY
THE LIFT HAS ARRIVED AT THIS FLOOR
THE LIFT DOORS HAVE OPENED
MISCELLANEOUS ANNOUNCEMENTS
10.1
10.2
10.3
10.4
10.5
10.6
10.7
10.8
10.9
10.10
10.11
10.12
10.13
10.14
10.15
10.16
PLEASE MIND THE STEP
CAUTION! LIFT OUT OF LEVEL, MIND THE STEP
LIFT FAILED TO START, PLEASE PRESS THE DOOR
OPEN PUSH
ATTENTION! ......
CAUTION! LIFT AUTOMATICALLY RE-LEVELS
CAUTION! LIFT RELEVELLING
PLEASE PRESS A BUTTON FOR THE REQUIRED FLOOR
LIFT DEPARTING IN .... SECONDS
LIFT DEPARTING IN .... MINUTES
MAINTENANCE ONLY
STAFF ONLY
PLEASE DO NOT SMOKE
LIFT PREPARING TO DEPART
LIFT REQUIRED AT ANOTHER FLOOR
DO NOT PANIC
LIFT RETURNING TO EXIT LEVEL
30.0.3
BACK
HOME
Appendix B
Female Phrase List – Page 2 of 2
11.
FLOOR MARKINGS
FLOOR….
….FLOOR
LEVEL…..
….LEVEL
DECK ….
…..DECK
BASEMENT
SUB BASEMENT
UPPER BASEMENT
LOWER BASEMENT
LOWER MEZZANINE
UPPER MEZZANINE
MEZZANINE
LOWER GROUND
UPPER GROUND
GROUND
1ST - 79TH
0 - 99
A - Z
GARAGE
CAR PARK
SHOPS
MALL
SHOPPING LEVEL
RESTAURANT
COURTS
PENTHOUSE
ROOF
MAIN ENTRANCE
ENTRANCE HALL
RECEPTION
MAIN RECEPTION
LOBBY
EXIT
STREET LEVEL
BOOKING HALL
REFECTORY
MINUS .....
PLUS .....
LIBRARY
COMPUTER CENTRE
PUBLIC TOILETS
SECURITY OFFICE
PLATFORM
TICKET HALL
TICKET OFFICE
CONCOURSE LEVEL
STAGE
SHOPPING LEVEL
BRIDGE
PLATFORMS …. AND …..
TOP FLOOR
BOTTOM FLOOR
WALK WAY
BRIDGE LINK
INTERMEDIATE LEVEL
OVERBRIDGE LEVEL
MAIN EXIT
FOOD HALL
FOOD COURT
PLAZA
FOYER
UPPER FOYER
LOWER FOYER
RETAIL LEVEL
30.0.4
BACK
HOME
Appendix C
Control Signal Voltages
Relevant to the following parts: MFSP24-g & MFSP24-CC
The control signal voltages generated by the lift controller must be compatible with the ranges listed in the table
below:
Control Signal Voltage
Current Consumption
Signal Type
12v +/- 6v ac/dc
5.5mA
AC and DC
24v +/- 6v ac/dc
5.1mA
AC and DC
100v +/- 20v dc
4.5mA
DC ONLY
110v +/- 10v ac
4.7mA
AC ONLY
240v +/- 10v ac
3.4mA
AC ONLY
The number of different control signal voltages permitted on one unit depends upon the type of unit purchased. See the
table below for details:
Type of Unit
Number of Signal Commons
Standard Unit (16 inputs)
5
Standard Unit + 8 Input Expansion Unit
6
Standard Unit + 16 Input Expansion Unit
7
Signalling Parameters
Relevant to the following parts: MFSP24-g & MFSP24-CC
Active Signal States
Each signal can be either open or closed circuit active (specify on ordering). Indicator
messages will remain on as long as the signal input is active. Speech announcements
are made once upon initial activation of the signal input; they are self triggered.
Position Signals
Discrete signalling requires:
n inputs for n floors
Binary & Gray Code signalling requires: 2 inputs for 1-3 floors
3
4
5
6
inputs
inputs
inputs
inputs
for
for
for
for
1-7 floors
1-15 floors
1-31 floors
1-63 floors
Directional Signals
Running arrows require 2 inputs
Intended next travel direction (hall lantern control) requires 2 inputs
(used for both speech and hall lantern control)
Floor Announce
To trigger floor announcement on arrival at floor 1 input is required
Miscellaneous
Announcements
and Messages
Require one input per feature. If a single feature requires both speech
and indicator messages only one input is required
COPYRIGHT 2005 STENTORGATE LTD
APPENDIXC/0605
30.0.5
BACK
HOME
Speech & Indicator Job Specification Sheet
Order Number
Site Reference
Customer
Contact
Floor Legend List
(List all floors served. Including phantom floors if relevant)
Date
Number of
Lifts
Floor Signal Coding Scheme
Floor Signal Voltages
Active Floor Signal State
Discrete
12v/24v
ac/dc
100v dc
Open Circuit
Binary (lowest
floor binary 0)
Binary (lowest
floor binary 1)
Gray Code (lowest
floor Gray 0)
Gray Code (lowest
floor Gray 1)
Floor Selector
Arrow Function
Closed Circuit
110v ac
240v ac
Arrow Style
(block or stick)
Arrow
on Car?
Arrow on
Landings ?
Signal Voltages
(specify)
Active Signal
State (OC/ CC)
Lift Running Arrow
Override Onward
Direction Arrow
Simultaneous Onward
Direction Arrow
Hall Arrival Chime
1x Gong Up,
1x Gong Down
1x Gong Up,
2x Gong Down
Ding Dong
Car Arrival Chime
1x Gong Up,
1x Gong Down
1x Gong Up,
2x Gong Down
Ding Dong
Messages & Voice Announcements
Speech ? On
(list voice announcements & scrolling (Y/N)
Car ?
messages)
(Y/N)
Car Passing Chime ? (Y/N)
On
Landings ?
(Y/N)
Signal
Voltage ?
(specify)
Active Signal
State ?
(OC/CC)
Active Signal States:
OC = Open Circuit (signal valid when no current flows between signal input and common return)
CC = Closed Circuit (signal valid when current flows between signal and common return)
Speech & Indicator Specification Sheet (Continuation Page)
Order Number
Site Reference
Customer
Contact
Floor Legend List
(List all floors served. Including phantom floors if relevant)
Messages & Voice Announcements
Speech ? On
(list voice announcements & scrolling (Y/N)
Car ?
messages)
(Y/N)
Date
Number of
Lifts
On
Landings ?
(Y/N)
Signal
Voltage ?
(specify)
Active Signal
State ?
(OC/CC)
Active Signal States:
OC = Open Circuit (signal valid when no current flows between signal input and common return)
CC = Closed Circuit (signal valid when current flows between signal and common return)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising