HYDRIM C61 washer-disinfector brochure

HYDRIM C61 washer-disinfector brochure
A new wave in automated
instrument washing and disinfection
Introducing the new HYDRIM G4 WD series
Taking control of your
infection control
The hazards of manual cleaning
Hand scrubbing is increasingly less used
because it exposes staff to the hazards
of skin punctures and can affect the
productivity of the practice as it takes
time away from patient care.
The limitations of
ultrasonic cleaning
Ultrasonic cleaning is also used but its
effectiveness compared to automated
washing has long been under question.
Ultrasonic cleaning requires subsequent
rinsing before sterilization, adding steps
to sterilization efficiency.
The challenge in both these methods
is the effect on human resources. As
Mark Tholen writes in Dental Economics,
“Decontaminating, washing, rinsing,
and drying instruments are extremely
labor intensive and dramatically reduce
the throughput speed of instrumentation
through sterilization.”*
He points to the automated washer
as the single greatest labor-saving device
in a dental office, concluding that,
“when [a washer is] used in combination
with cassettes, approximately one hour
of labor can be saved for every nine
procedural set-ups that are processed
through sterilization.”*
How automated washer-disinfectors in dental
practices improve the sterilization process
The use of automated instrument washer-disinfectors (WD)
is growing worldwide as regulatory authorities and dentists
endorse and adopt what has come to be understood as
the most effective and consistent means of cleaning and
disinfecting instruments before sterilization.
Cleaning and Disinfection are the important first step in the
sterilization chain.
Delivering consistent,
validated cleaning results
Consistent repeatable cycles are a key
advantage to using automated washers
because this offers the user control.
It ensures every set of instruments
receives the same validated cleaning
process, and cycle data is recorded
to provide accurately detailed and
consistent documentation that
establishes an accountability baseline
for instrument cleaning.
* Tholen, Mark, 10 Ideas to Increase Production and Decrease
Expenses in Sterilization. (www.dentaleconomics.com/articles/print/volume-99/issue-10/features/increase-productionand-decrease-expenses-in-sterilization.html)
2
1
HYDRIM meets the Internet
The HYDRIM G4 is equipped with a web interface that enables
online access and offers a platform with endless possibilities.
connect
The HYDRIM G4 is capable
of communicating directly
with service personnel
or anyone you choose.
Should the HYDRIM G4 ever
need attention, diagnostic
information can be sent via
email to pre-selected dealer
service reps, significantly
reducing down time.
protect
A high-resolution, 65K color touch
screen offers a vivid display of
messages, current cycle
information and customizable
colors all with extraordinary
clarity. Fully adjustable contrast
levels let you optimize the screen
to the lighting in your steri-center,
and it’s 2.5-inch by 3-inch
dimensions allow easy viewing
of cycle information.
Patient safety relies on attention
to detail. The HYDRIM G4
supports verifiable processes
that are PIN protected with
user-defined IDs so that staff
members can be required
to authorize a cycle. This
encourages extra attention
to process and creates a
safer environment for both
staff and patient.
collect
With each cycle, information must be stored to protect your
office and your patients. The integrated data logger stores
all cycle information for the lifetime of the unit. A USB port
allows for the manual
retrieval of cycle history. The
10/100 Base-T Ethernet
connection puts your PC in
direct contact with your
HYDRIM G4 and the RS232
serial printer port allows you
to connect with an external
printer.
2
HYDR
HYDRIM c61 wd G4
washer-disinfector
Benefits
specifications
n Designed
Size:
in accordance with
ISO 15883-1 and -2, the international
standard for washer-disinfectors
n The
unit can be installed on the
countertop or built into a steri-center
under the counter
n Large
chamber volume – 6 full sized
IMS cassette capacity, the HYDRIM
C61wd can turn over 120 instruments
in just 60 minutes – start to dry
n G4
web portal interface includes
data storage, service logs and remote
access capabilities
n Validated
cycles to ensure repeatable
washing and disinfection performance
n HIP
cleaning solution is stored the unit,
so no extra storage space requirements
n Improved
serviceability, reliability and
minimal maintenance requirements
n Robust
n Vivid
stainless steel exterior
Dimensions: (w x h x d) Depth with door open: Weight: 598 x 520 x 526mm
(23.5” x 20.5” x 20.7”)
82.9 cm 32.6”
44kg / 97lbs
Cycle Times*
Rinse and Hold Regular Wash + Dry Heavy Duty Wash with Disinfection + 5 mins
26 mins. + 10 mins.
42 mins. + 10 mins.
Water Consumption Per Cycle:
Rinse and Hold Regular Wash Heavy Duty Wash & Disinfection 7.6 litres / 1.7 gallons
11.5 litres / 3 gallons
11.5 litres / 3 gallons
Electrical Connection
Electrical Rating:
Running noise: 208-240V, 12A, 60 Hz
< 65 dB
Water and Drain Connections
Hot and Cold Water Tap Connection 3/4” Garden hose, male
Recommended Hot Water Temperature 60°C / 140°F
Cold Water Temperature < 30°C / 86°F
Inlet Water Pressure 1 - 10 bar / 14.5 - 145 psi
Drain 2 cm / 3/4”
color touch screen
n Active
*Actual cycle times will vary with incoming water temperature and pressure.
drying with a HEPA filter
Manufactured in Canada
Accessories
Two basket rack
p/n 01-113257
16” x 6”x 16”
(407 x 154 x 37mm)
3
Six cassette rack
p/n 01-113251
16 x 15 x 5”
(424 x 390 x 137mm)
Four double stacked cassette
p/n 01-113252
16 x 15 x 5”
(424 x 390 x 137mm)
Three cassette, two basket rack
p/n 01-113253
16” x 15” x 5”
(424 x 390 x 137mm)
RIM
Click here
to watch the
video.
Cycles
Ten tray two basket rack
p/n 01-113254
16” x 15” x 5”
(424 x 390 x 137mm)
Large basket
p/n/ 01-113547
8.5 x 7” x 2”
(217 x 172 x 54mm)
Basket with hinged lid
p/n 01-113547
8.5” x 7” x 2”
(217 x 172 x 54 mm)
HIP ULTRA
cleaning solution
p/n CS-HIPC
(8 X 750ML)
4
HYDR
HYDRIM M2 G4
washer-disinfector
Benefits
specifications
n Designed
Size:
in accordance with ISO
15883-1 and -2, the international
standard for washer-disinfectors
Dimensions: (w x h x d) Depth with door open: Weight: n HYDRIM
M2 G4 can process 1,500
instruments in a 10-hour day
n Under
counter steri-center installation,
but can also be a freestanding unit
n G4
web portal interface includes
data storage, service logs and
remote access capabilities
cycles to ensure repeatable
washing and disinfection performance
cleaning solution is stored in
the unit, so no extra storage space
requirements
n Vivid
Rinse and Hold 9 mins
Regular Wash + Dry 31 mins. + 20 mins.
Heavy Duty Wash with Disinfection + Dry 51 mins. + 20 mins.
Rinse and Hold Regular Wash Heavy Duty Wash 11.5 litres / 3 gallons
19 litres / 4.75 gallons
25 litres / 6.25 gallons
Electrical Rating:
Running noise: 230-240VAC ±10%, 60 Hz, 12A
< 65 dB
Water and Drain Connections
port for data storage
stainless steel exterior
color touch screen
n Active
n HIP
n Robust
Electrical Connection
8” x 11” IMS cassette capacity
n USB
Cycle Times*
Water Consumption Per Cycle:
n Validated
n Ten
600 x 850 x 600 mm
(23.75” x 33.5” x 23.75”)
1200 mm / 47”
80 kg / 176 lbs.
drying with a HEPA filter
Hot and Cold Water Tap Connection 3/4” Garden hose, male
Recommended Hot Water Temperature 60°C / 140°F
Cold Water Temperature < 30°C / 86°F
Inlet Water Pressure 1 - 10 bar / 14.5 - 145 psi
Drain 2 cm / 3/4”
*Actual cycle times will vary with incoming water temperature and pressure.
Manufactured in Canada
Accessories
Hinged instrument rack
p/n 01-110409S
7.5” x 4” x 4.3”
(192 x 100 x 109 mm)
5
Basket with hinged lid, 1/4 size
p/n 01-109966S
6” x 8.5” x 2”
(159 x 216 x 54 mm)
Hygiene basket, 1/4 size
p/n 01-109967S
6” x 8.5” x 2
(159 x 216 x 44mm)
STATIM 2000 Basket
p/n 01-107240
11” x 7” x 1.5”
(275 x 178 x 42mm)
RIM
Cycles
STATIM 5000 Basket
P/N/ 01-107241
13.5” x 7” x 1.5”
(373 x 178 x 42 mm)
Long Basket
p/n 01-108232
18” x 6” x 1.5”
(442 x 150 x 42 mm)
Cleaning Solution
Bottle
CS-HIPL
Case of 2 x 3.8 L
5-Cassette Rack, Full Size
p/n 01-109963S
19” x 13 x 6”
(480 x 355 x 158 mm)
5-Cassette Rack, Half Size
p/n 01-109964S
19” x 7” x 6 “
(480 x 168 x 158 mm)
6
STATIM® 5000 G4
BRAVO™
Cassette autoclave
Cassette autoclave
Vacuum chamber autoclave
OPTIM® 33TB
STATMATIC™
STATMATIC™ PLUS*
Surface cleaner and disinfectant
Automatic handpiece
maintenance unit
Automatic handpiece
maintenance unit
SANAO™*
STATIS®*
STATMAT
Handpieces
Hign speed handpieces
Silicone mat for STATIM autoclaves
Manufactured by:
SciCan Ltd.
1440 Don Mills Rd., Toronto, Ontario M3B 3P9
Phone (416) 445-1600 • Fax (416) 445-2727
Toll Free 1-800-667-7733 • custservice.ca@scican.com
*Manufactured by:
SciCan GmbH
Wangener Strasse 78
88299 Leutkirch GERMANY
Tel.: +49 (0)7561 98343 - 0
Fax: +49 (0)7561 98343 - 699
Follow us on:
Facebook: I love STATIM
Twitter: @SciCan_EU
www.scican.com
STATIM, STATIS, OPTIM and HYDRIM are registered trademarks of SciCan Ltd. Your Infection Control Specialist, STATFlow, BRAVO, SANAO & STATMATIC are trademarks of SciCan Ltd. SD-418 EN
STATIM® 2000 G4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising