coriflex led - Light Culture

coriflex led - Light Culture
CORIFLEX LED
WITH MRX TECH­NOLOGY
FOR OFFICE A
­ PPLICATIONS
Complete glare elimination. With TRILUX technology.
Thanks to new TRILUX technology (MRX, Micro-Reflector-Technology) the direct
light is completely glare-free, and with the further developed UGR19 optic it is also
suitable for especially challenging lighting situations for example in offices or the
­educational sector.
One system. Many applications.
The highly flexible, modular kit system with corner connection modules, tracks,
sensor modules and either direct/indirect or purely direct light adapts individually
to customer requirements and applications.
One component. Half the installation time.
Only one component needs to be installed because of integration of the track,
gear tray and optic into the luminaire. This reduces assembly time by 50 %.
Clever. A continuous line in next to no time.
With the help of the Plug & Play click system, Coriflex LED is rapidly and reliably
­connected to a continuous line. The compact 1-metre elements ensure more flexibility
with planning and also simplify handling.
CoRIFLEX LED
88
92
LED rapid mounting luminaire
50
1130
Coriflex LED
92
88
50
1130
150
II
Safety class
IP40
Protection rating
IK02/0.2 J
IK code/impact resistance
650 °C
Glow wire resistance
Eta LB
1.00
DIN 5040
C41
6549
Mounting methods
Fixing either via wire or chain suspension or
direct to ceiling. Modules replaced without tools.
In combination with blind modules, the position of
continuous line modules can be changed without
tools within a continuous line.
Optical system
Optical system consists of a PMMA refractor-reflector system with centrally integrated high power
LEDs. With MRX micro reflectors for VDU-compliant
lighting in compliance with EN 12464-1 via limited
luminance L ≤ 1500 cd/m² or L ≤ 3000 cd/m² for
beam angles above 65° all round, with L ≤ 3000
cd/m² suitable for computer screens with positive
polarity and self- luminance greater than 200 cd/m².
Direct glare limitation in accordance with UGR<19.
LED system
···H1···3500··· Direct distribution module 3500 lm,
connected load 33 watts, luminous efficiency of
luminaire 106 lm/W. Limit luminance L ≤ 3000 cd/m².
···H2···5500··· Direct/indirect distribution module
5500 lm, indirect luminous flux 2000 lm, connected
load 52 watts, luminous efficiency of luminaire
106 lm/W. Limit luminance L ≤ 3000 cd/m².
···830··· Light colour warm white (ww), colour
­temperature 3000 K, colour rendering index Ra > 80.
···840··· Light colour neutral white (nw), colour
­temperature 4000 K, colour rendering index Ra > 80.
Luminous flux degradation L80/B10 after 50,000
operating hours at 35°C ambient temperature.
www.trilux.com/
coriflex-led/
Luminaire body
Outer module housing of extruded aluminium with
precise, flat visible surfaces and fine edge radii.
Inner support profile, of sheet steel. Luminaire body
powder-coated. Module length: 1130 mm.
···01··· Colour white.
···03··· Colour silver-grey.
···I2··· Colour black.
Electrical connection
Factory pre-wired with 7 heat-resistant 2.5 mm²
single conductors. Modules can be interconnected
to a continuous line without tools, the electrical
connection is self-actuating. Free selection of phase
conductor also with inserted gear tray possible at
all times without tools. Connection to ceiling-sided
mains cable possible via integrated 7-pole plug
terminal to 2.5 mm² in all continuous line modules.
Electrical version
···ET··· With electronic transformer, switchable.
···ETDD··· With electronic transformer, digitally
dimmable (DALI).
Energy efficiency example
Office
Old system
LLB
Old system
ECG
Old system
ECG
New system
LED
Luminaire
Old recessed luminaire
T8 – 4 x 18 LLB
TCT 1 x 26 LLB
84 W + 31 W
4+3
429 W
1,180 kWh
€ 406*
Old recessed luminaire
T8 – 4 x 18 ECG
TCT 1 x 26 ECG
76 W + 28 W
4+3
388 W
1,076 kWh
€ 367*
Old recessed luminaire
T5 – 414 ECG
TCT 1 x 26 ECG
61 W + 28 W
4+3
328 W
902 kWh
€ 309*
Coriflex
Coriflex LED – 5,400 lm
+ InperlaLigra – 2,000 lm
52 W + 21 W
2+2
146 W
402 kWh
€ 138*
Power consumption per luminaire
Number of luminaires in building
Total power consumption
Kilowatt hours p.a.
Energy costs ¶ p.a.
Energy saving potential
Saved kilowatt hours p.a.
Energy saving ¶ p.a.
CO2 saving p.a.
* Based on a nominal price of € 0.25 per kWh in 2014 and an annual inflation rate of 5% over 15 years (each with 2,750 hrs.) of service life.
T8 – LLB
66 %
778 kWh
€ 269*
0.37 tonnes
T8 – ECG
63 %
674 kWh
€ 228*
0.33 tonnes
T5 – ECG
55 %
500 kWh
€ 172*
0.23 tonnes
14/43-GB-int. 092 083
Luminaire type
Rapid mounting LED luminaire as continuous line
version.
···H1-E··· Version as single luminaire or continuous
line start module, direct distribution.
···H1-LM··· Version as central luminaire or conti­
nuous line end module, direct distribution.
···H2-E··· Version as single luminaire or continuous
line start module, direct/indirect distribution.
···H2-LM··· Version as central luminaire or conti­