Titan Neo P Series
Professional Series
Green
Power
Environmental
Friendly
Energy
Saving
Titan Neo P Series
True Double Conversion Online UPS
•
User Friendly LCD Display
•
Microprocessor Control Optimizes Reliability
•
Input Power Factor Correction
•
0.8 Output Power Factor
•
Wide Input Range (110V - 300V)
•
ECO Mode for Energy Saving (1K-3K Model only)
•
Generator Compatible
•
Comes with USB Port , RS232 Port, SNMP Slot & Power Management
Software
&
Boost
Buck AVR
• Boost & •
Buck AVR
3
JAPAN
Warranty
YUASA
• Long Back-up •
Time
• Software •
• 3 Years •
Warranty
Professional Series
3
4
5
5
5
5
4
4
3
3
3
4
6
1. AC Input Socket
2. Output Socket
6
6
6
3. Intelligent Slot
2
2
7
5. RS-232 Communication Port
8
7
2
1
1
4. USB Communication Port
8
1
6. External Battery Connection
2
7
7
(KS Model Only)
1
7. Input Circuit Breaker
Titan Neo P 1K/2K
Titan Neo P 1KS/2KS
Titan Vista Neo P3K
Titan Vista Neo P3KS
(Back View)
(Back View)
(Back View)
(Back View)
8. Input/Output Terminal
Technical Specification:
MODEL
Titan Neo P 1K
CAPACITY ( VA/W )
Titan Neo P 1KS
Titan Neo P 2K
1000VA/800W
Titan Neo P 2KS
Titan Neo P 3K
2000VA / 1600W
INPUT
NOMINAL VOLTAGE
Titan Neo P 3KS
3000VA / 2400W
100/110/115/120/127VAC or 200/208/220/230/240VAC
55 - 150VAC or 110 - 300VAC (Based on load at 50%)
VOLTAGE RANGE
85 - 140VAC or 160 - 280VAC (Based on load at 100%)
40 ̴ 70Hz
FREQUENCY RANGE
PHASE
Single Phase with Ground
≥ 0.99 @ Nominal Voltage (100% Load)
INPUT POWER FACTOR
OUTPUT
OUTPUT VOLTAGE
100/110/115/120/127VAC or 200/208/220/230/240VAC
OUTPUT POWER FACTOR
0.8
± 1%
VOLTAGE REGULATION (Batt. Mode)
47 ̴ 53Hz or 57 ̴ 63Hz
FREQUENCY RANGE (Synchronized Range)
50Hz ± 0.25Hz or 60Hz ±0.3Hz
FREQUENCY RANGE (Batt. Mode)
CURRENT CREST RATIO
TOTAL HARMONIC DISTORTION (THDv)
3 :1
≤ 3% @ Linear Load ; ≤ 6% @ Non-Linear Load
WAVEFORM
Pure Sinewave
Zero
TRANSFER TIME (AC to DC)
TRANSFER TIME (Inverter to Bypass)
4 ms (Typical)
OUTPUT SOCKET
BATTERY
SEALED LEAD ACID MAINTENANCE FREE BATTERY CSB/YUASA/PANASONIC Japan Battery
12V 9AH x 2pcs
BACKUP TIME (Depending on Load)
15 - 20 minutes
RECHARGE TIME
4 Hours to 90%
CHARGING CURRENT (MAX)
3 x British Socket + 1
1 x British + 1 Terminal Block
Terminal Block
2 x British Socket
1A
Depending on the
capacity of External
Batteries
12V 9AH x 4pcs
Max 6A
1A
15 - 20 minutes
4 Hours to 90%
Depending on the
capacity of External
Batteries
12V 9 AH x 6pcs
Max 6A
1A
15 - 20 minutes
Depending on the capacity
of External Batteries
4 Hours to 90%
Max 6A
STATUS INDICATION
LCD DISPLAY
AUDIBLE ALARM
Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, UPS Fault
Battery Mode, Low Battery, UPS Fault, Overload
COMMUNICATION
Support Window Family, Linux, Sun Solaris, IBM Aix, Compaq True 64, FreeBSD, HP-UX, MAC
POWER MANAGEMENT SOFTWARE
- Automatically Shut-down, Saves Application Data Before Exit
- Power Flow Display for Monitoring UPS Status
- Schedules System Shutdown/Restart
- Warning Notification Via E-Mail/Pager/Broadcast
- Remote Monitor/Control via LAN
- Safety Shutdown Multi System
INTERFACE
USB Port or RS 232 Port
SNMP Slot
Yes
SURGE PROTECTION & FILTERING
SPIKE, SURGE & LIGHTNING PROTECTION
Yes
OVERLOAD, SHORT CIRCUIT PROTECTION
Yes
- Records Logs for Analysis
PHYSICAL
0-40°C, 20 - 90% Rela ve Humidity (Non-Condensing)
OPERATING ENVIRONMENT
NOISE LEVEL
< 50dB @ 1 Meter
282 x 145 x 220
DIMENSION (DxWxH)mm
WEIGHT (KG)
9.8
WARRANTY
UPS WARRANTY
*Specification subjects to change without prior notice
www.RightPowerUPS.com.my
397 x 145 x 220
4.1
17
6.8
421 x 190 x 318
397 x 145 x 220
27.6
7.4
3 Years Full Warranty Include Parts & Labour . 2 Years Warranty for Battery
Professional Series
3 5
4
2
7
4
3
5
8
2
7
6
1. Input/Output Terminal
8
1
2. Intelligent Slot
3. USB Communication Port
4. RS-232 Communication Port
6
5. External Battery Connection
6. Input Circuit Breaker
1
7. Emergency Power Off (EPO)
8. Maintenance Bypass Switch (Optional)
Titan Vista Neo P 6K/10K
Titan Vista Neo P 6KS/10KS
(Back View)
(Back View)
Technical Specification:
MODEL
Titan Neo P 6K
CAPACITY ( VA/W )
INPUT
NOMINAL VOLTAGE
Titan Neo P 6KS
FREQUENCY RANGE
PHASE
INPUT POWER FACTOR
OUTPUT
OUTPUT VOLTAGE
OUTPUT POWER FACTOR
VOLTAGE REGULATION (Batt. Mode)
FREQUENCY RANGE (Synchronized Range)
FREQUENCY RANGE (Batt. Mode)
CURRENT CREST RATIO
TOTAL HARMONIC DISTORTION (THDv)
WAVEFORM
TRANSFER TIME (AC to DC)
TRANSFER TIME (Inverter to Bypass)
OUTPUT SOCKET
BATTERY
SEALED LEAD ACID MAINTENANCE FREE BATTERY CSB/YUASA/PANASONIC Japan Battery
BACKUP TIME (Depending on Load)
RECHARGE TIME
CHARGING CURRENT (MAX)
STATUS INDICATION
LCD DISPLAY
AUDIBLE ALARM
COMMUNICATION
INTERFACE
SNMP Slot
EMERGENCY POWER OFF (EPO)
SURGE PROTECTION & FILTERING
SPIKE, SURGE & LIGHTNING PROTECTION
OVERLOAD, SHORT CIRCUIT PROTECTION
PHYSICAL
OPERATING ENVIRONMENT
NOISE LEVEL
DIMENSION (DxWxH)mm
WEIGHT (KG)
WARRANTY
UPS WARRANTY
Titan Neo P 10KS
10KVA/8,000W
208/220/230/240VAC
110 - 300VAC (Based on load at 50%)
176VAC -300VAC (Based on load at 100% Load)
46Hz ̴ 54Hz or 56Hz 64Hz
Single Phase with Ground
≥ 0.99 @ Nominal Voltage (100% Load)
VOLTAGE RANGE
POWER MANAGEMENT SOFTWARE
Titan Neo P 10K
6KVA/4,800W
208/220/230/240VAC
0.8
± 1%
46Hz ̴ 54Hz or 56Hz 64Hz
50Hz ± 0.1Hz or 60Hz ±0.1Hz
3 :1
≤ 3% @ Linear Load ; ≤ 6% @ Non-Linear Load
Pure Sinewave
Zero
Zero
Terminal Block
12V 9AH x 12pcs
15 - 20 minutes
9 Hours to 90%
12V 9AH x 16pcs
Depending on the capacity of
External Batteries
Depending on the capacity of
External Batteries
15 - 20 minutes
9 Hours to 90%
1A/2A
Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, UPS Fault
Battery Mode, Low Battery, UPS Fault, Overload
Support Window Family, Linux, Sun Solaris, IBM Aix, Compaq True 64, FreeBSD, HP-UX, MAC
- Automatically Shut-down, Saves Application Data Before Exit
- Power Flow Display for Monitoring UPS Status
- Schedules System Shutdown/Restart
- Warning Notification Via E-Mail/Pager/Broadcast
- Remote Monitor/Control via LAN
- Safety Shutdown Multi System
- Records Logs for Analysis
USB Port or RS 232 Port
Yes
Yes
Yes
Yes
0-40°C, 0 - 95% Relative Humidity (Non-Condensing)
< 55dB @ 1 Meter
369 x 190 x 573
61
*Specification subjects to change without prior notice
www.RightPowerUPS.com.my
< 58dB @ 1 Meter
369 x 190 x 318
12
442 x 190 x 688
66
3 Years Full Warranty Include Parts & Labour. 2 Years Warranty for Battery
442 x 190 x 318
16