1Safety Information
This apparatus has been designed and tested in accordance with BS EN 61010-1,
and has been supplied in a safe condition. This manual contains some information warnings which must be followed to ensure safe operation, and to retain
the apparatus in a safe condition.
This apparatus does not incorporate components liable to explode or implode
during normal operating conditions. In normal operating conditions this apparatus does not liberate injurious or poisonous gases.
Sound levels of this apparatus after installation in a rack are below 85 dBA,
as required by EN 61010-1. However local regulations may have a lower limit
or the system as a whole may exceed the local limit. In this case appropriate
action should be taken, ie of use of any protective equipment required by local
regulations.
This apparatus is of installation category 2.
5
6
This apparatus is capable of delivering harmful levels of
radio frequency power. Ensure at all times during operation that the RF output is properly terminated with an
adequately rated termination or transducer, and that the
cables and connectors attached to the apparatus are in
good condition.
The mains plug shall only be inserted in a socket outlet
provided with a protective earth contact. The protective
action must not be negated by the use of an extension
cord without a protective conductor.
The opening of covers or removal of parts is likely to
expose live parts.
This apparatus must be disconnected from all voltage
sources before it is opened for adjustment, replacement,
maintenance or repair.
Make sure that only fuses of the required rated current
and of the specified type are used for replacement. The
use of makeshift fuses and the short-circuiting of fuse
holders is prohibited.
CBA 100M-400 User Manual
2Introduction
CBA 100M-400 Introduction
The CBA 100M-400 is an amplifier capable of supplying 400 watts into a 50
ohm load over the frequency range 10 kHz to 100 MHz, during the course of
EMC tests on electrical equipment. The amplifier is designed with sufficient
gain such that it may be used with normal output levels of signal sources. A
safety interlock on the rear panel is also provided, which will mute the amplifier
when grounded.
The unit is powered from a switched mode power supply for high efficiency,
high power factor and wide voltage range operation. The unit is air cooled with
integral fans, and is protected against faulty cooling by excess temperature
sensing.
A front panel indicator is provided to indicate over-temperature. The amplifier is
designed for rugged operation into a variety of loads. The amplifier is primarily
intended for use as a power source for EMC susceptibility testing, but is also
applicable to other systems requiring a wide-band linear amplifier.
This amplifier is designated as ‘professional equipment’ and should not be
operated by untrained staff.
As this product has the capability to generate high levels of RF energy it is not
intended for use in a residential environment.
Potential or theoretical hazards.
7
8
Threat
Precaution
Exposure of personnel to high RF fields Ensure that the antenna is inside a
produced by an antenna connected to screened enclosure and fit an interlock
the output of the amplifier.
to the entry door to prevent access
while the amplifier is operating.
RF burns caused by contact with the Ensure that the antenna is inside a
antenna connected to the output of screened enclosure and fit an interlock
the amplifier.
to the entry door to prevent access
while the amplifier is operating.
Amplifier self oscillation caused by This is an unlikely but theoretical
feedback from un-terminated con- possibility. Always ensure that the
amplifier input is terminated either
nectors.
by the system signal generator or by
a suitable RF load/attenuator before
switching the amplifier on.
Arcing due to high RF voltages present Always ensure that the output of the
at the output connector.
amplifier is terminated either by the
system antenna or a suitable high
power RF load or attenuator.
CBA 100M-400 User Manual
3Unpacking and installation
3.1 Unpacking
The CBA 100M-400 package should contain:
10 kHz to 100 MHz Amplifier
Power cable (UK) Power cable (USA / JAPAN)
Power cable (EUROPE)
Spare fuse T 10 A time delay 20 mm
CBA 100M-400 Operating manual (this document)
Calibration report
CBA 100M-400
If any signs of damage are found, no attempt should be made to install the
instrument, which should be returned to Teseq or their agent. If the shipping
carton has been damaged, retain the shipping carton and packing material
for the carrier’s inspection. Check that the equipment is complete as in the
packing list above.
3.2 Installation
This instrument must be earthed.
9
10
4Operation
4.1 Front panel
Mains switch
Operating the mains switch will apply power to the amplifier gain stages and
fan.
Power indicator
This indicator will illuminate when the mains switch is turned on, and power is
available from the mains.
Fault indicator
Should the amplifier be subject to a failing in the cooling system, either by a
fan failure, inadequate air supply or excess ambient temperature, this indicator
will illuminate and the amplifier gain stages will all be turned off. This action is
non-latching, so the gain stages will switch on again when the amplifier has
cooled down.
RF input (depending on model)
The RF input will accept a signal from an RF generator. This input must be
within the operating frequency range of the amplifier. An amplitude of up to 0
dBm will be sufficient to saturate the amplifier. Operation outside the specified
frequency range should not be attempted, and may subject the amplifier to
undue internal stress.
RF output (depending on model)
This connector must be suitably terminated at all times during operation. Ensure
that the cable and load are all capable of handling the power available, which
may be as much as 600 watts. On no account operate the amplifier without a
proper termination or with defective cables or connectors. The centre conductor of the rf output represents a severe burn hazard to personnel.
CBA 100M-400 User Manual
Air inlet
The amplifier depends upon a free air supply for cooling. Ensure that the front
air inlet is not restricted.
4.2 Rear panel
Mains input
The mains input is an IEC 60320 type. The cable attached to the mains input
must be rated at 10 A to ensure proper operation at the minimum line voltage
of 85 Vac. The fuse-holder is integral with this mains connector. Use 10 A antisurge (T).
Input/output connectors (depending on model)
The RF input and output connectors may optionally be placed on the rear
panel.
Fan outlet
The amplifier depends upon a free air supply for cooling. Ensure that the fan
outlets are not restricted.
11
12
5Specification
The following specification applies over the operational temperature and frequency range unless otherwise stated, and does not include the characteristics
of connecting cables.
Frequency range (instantaneous) Rated output power Output power at 1 dB gain compression Gain Third order intercept point Gain variation with frequency Harmonics at 300 W output power Output impedance Stability
Output VSWR tolerance Input VSWR RF connector style Safety interlock USB interface 0.01–100 MHz
400 W minimum
300 W minimum
57 dB
67 dBm
±2 dB
Better than -20 dBc
50 Ohms
Unconditional
Infinity:1
2:1
Type N female
BNC female, s/c to mute
Optional
EMC and safety
Conducted and radiated emissions Conducted and radiated immunity Mains harmonic currents Voltage fluctuations and flicker
Safety EN 61326 class A
EN 61326: 1997 table 1
EN 61000-3-2
EN 61000-3-3
EN 61010-1
CBA 100M-400 User Manual
Power
Supply voltage (1-phase)
Supply frequency range Supply power Mains connector 184-264 Vac
45-63 Hz
<2 kVA
IEC 320
Environmental
Operating temperature range 0-40°C
Mechanical
Case dimensions Weight
13
19 inch, 9U case, 570 mm deep
33 kg
Options (select at time of ordering)
341-200 Rack mountable with rear panel mounted input/output connectors
Notes
1 The third order intercept point is a nominal value, as its calculation depends
upon the power level at which distortion measurements are made.
2 Output VSWR tolerance is specified for excitation within the permitted levels
and frequency range.
14
6Warranty
Hardware
Teseq Limited (the company) warrants its amplifiers to be free from defects in
workmanship and materials, under normal use and service, for three years from
the date of purchase from the company or its authorised agent.
If a product does not operate as warranted during the warranty period, the
company shall, at its option, repair the defective product or part, deliver an
equivalent product or part to replace the defective item, or refund the purchase
price paid for the defective product. Transportation of the defective product or
part to the factory or service centre is to be pre-paid by the customer. All products that are replaced will become the property of the company. Any replaced
or repaired product or part has a ninety (90) day warranty or the remainder of
the initial warranty period, whichever is longer.
All information in this manual is given in good faith. However, the company shall
not be liable for any loss or damage whatsoever arising from the use of this
manual, the product described in it or any errors or omissions in either.
CBA 100M-400 User Manual
NOTES
15
16
Headquarters
Teseq AG
4542 Luterbach, Switzerland
T + 41 32 681 40 40
F + 41 32 681 40 48
sales @ teseq.com
www.teseq.com
Manufacturer
Teseq AG
4542 Luterbach, Switzerland
T + 41 32 681 40 40
F + 41 32 681 40 48
sales @ teseq.com
China
Teseq Company Limited
T + 86 10 8460 8080
F + 86 10 8460 8078
chinasales @ teseq.com
France
Teseq Sarl
T + 33 1 39 47 42 21
F + 33 1 39 47 40 92
francesales @ teseq.com
Germany
Teseq GmbH
T + 49 30 5659 8835
F + 49 30 5659 8834
desales @ teseq.com
Japan
Teseq K.K.
T + 81 3 5725 9460
F + 81 3 5725 9461
japansales @t eseq.com
Singapore
Teseq Pte Ltd.
T + 65 6846 2488
F + 65 6841 4282
singaporesales @ teseq.com
Switzerland
Teseq AG
T + 41 32 681 40 50
F + 41 32 681 40 48
sales @ teseq.com
Taiwan
Teseq Ltd.
T + 886 2 2917 8080
F + 886 2 2917 2626
taiwansales @ teseq.com
UK
Teseq Ltd.
T + 44 845 074 0660
F + 44 845 074 0656
uksales @ teseq.com
USA
Teseq Inc.
T + 1 732 417 0501
F + 1 732 417 0511
Toll free +1 888 417 0501
usasales @ teseq.com
© December 2010 Teseq®
Specifications subject to change
without notice. Teseq® is an ISOregistered company. Its products are
designed and manufactured under
the strict quality and environmental
requirements of the ISO 9001. This
To find your local partner within document has been carefully checked.
Teseq®’s global network, please go to However, Teseq® does not assume
www.teseq.com
any liability for errors or inaccuracies.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising