comelit, why?
WHY CHOOSE COMELIT LED
SYSTEMS?
A careful evaluation is essential above all with regard
to these new applications being presented to market
as innovative solutions.
Without an adequate knowledge and a highly professional approach there is the risk of losing all of the
advantages that characterise this technology which
has been identified as the lighting of the future.
It is therefore fundamental to identify: the best dissipation system, a product suitable to the application, an
analysis of the working conditions and the choice of
the best power supply.
Comelit with its highly professional and historic experience, presents itself as an ideal partner to find and
apply the best solutions for each new project.
The high standard of quality, the accurate choice of
the raw materials to be used, the strict checks on the
product, the respect of all related international standards, guarantee an optimal performance and efficiency making Comelit LED systems into products of
the highest quality and reliability.
3
led, why?
ENERGY SAVING
The energy use of a LED lamp is noticeably lower, considering the same amount of light emitted, in comparison with that of other light sources. This prerogative
has been further improved by Comelit by means of a
purposely built light control sensor, which allows the
modification from maximum intensity, in dark conditions,
to total switch off, in the presence of sufficient ambient
light.
EFFICIENCY AND LONGEVITY
One of the main characteristics of LEDs is that of having a life expectancy which is much higher than of
other light sources. Comelit LED systems are guaranteed for 50 000 hours.
POST SALES
The high efficiency and longevity of the LED, means
a radical reduction in the costs for maintenance and
post sales, guaranteeing in this way to the user a big
saving in terms of management and assistance costs.
4
standards
STANDARDS
EN62471 2008 Photobiological safety of lamps and
lamp systems
EN61347-2-13 Lamp controlgear. Particular requirements for d.c. or a.c. supplied electronic controlgear
for LED modules
EN62384 DC or AC supplied electronic control gear
for LED modules. Performance requirements
EN 62031 LED modules for general lighting. Safety
specifications
IEC 60529 degrees of protection provided by enclosures (IP code)
5
SPOT LIGHT
55
SPOT LIGHT
Parabola with flat profile
55
VERSION A FLAT SERIES
TORSION SPRING
THROUGH HOLE 56/58 mm
Torsion spring guarantees hold on applications with panels up to 30 mm thickness
PROPERTIES
Parabola with deep or flat profile manufactured in polycarbonate. Easy fixing system wih torsion
spring. Led high luminosity technology, long life and available in different colours. Heat sink in aluminium studied for efficient heat elimination. Free wire connection with 35 cm standard length. Ring with
external finish avaliable in different colours. Standard protection grade IP54. Standard protection
grade IP65 supplied on request (obtained with O-Ring). Total absence of UV rays emission. Power
supply with constant current (FEMTO LED COMELIT)
APPLICATION
On all panels provided with through hole and max 30mm thickness
NOTES
For correct usage of led lamp for your application please contact Comelit technical staff
7
Parabola with flat profile
SPOT LIGHT
55
VERSION B FLAT SERIES
TAPE SPRING
panel cut template (mm)
THROUGH HOLE 56/58 mm and ANTIROTATION
Tape spring guarantees hold and antirotation on applications with metalic panels up to 2mm
thickness
PROPERTIES
Parabola with deep or flat profile manufactured in polycarbonate. Easy fixing system with tape
spring. Led high luminosity technology, long life and available in different colours. Heat sink in aluminium studied for efficient heat elimination. Free wire connection with 35 cm standard length. Ring with
external finish available in different colours. Standard protection grade IP54. Protection grade IP65
supplied on request (with O-Ring). Total absence of UV rays emission. Power supply with constant
current (FEMTO LED COMELIT)
APPLICATION
On metallic panels with through holes and thickness up to 2mm with antirotation. On dead holes
with P>15mm
NOTES
For correct usage of led lamp for your application please contact the Comelit technical staff
8
55
VERSION C FLAT SERIES
TAPE SPRING
SPOT LIGHT
Parabola with flat profile
DEAD HOLE 56/58 mm
H>14mm
This kind of tape spring guarantees hold on wood panels with dead holes. A minimum hole depth
of 14mm is required
PROPERTIES
Parabola with deep or flat profile manufactured in polycarbonate. Easy fixing system with tape
spring. Led high luminosity technology, long life and available in different colours. Heat sink in aluminium studied for efficiìent heat elimination. Free wire connection with 35 cm standard length. Ring
with external finish available in different colours. Standard protection grade IP54. Protection grade
IP65 supplied on request (with O-Ring). Total absence of UV rays emission. Power supply with constant current (FEMTO LED COMELIT)
APPLICATION
In particular on panels with dead holes with hole depth of at least 14mm
NOTES
For correct usage of led lamp for your application please contact the Comelit technical staff
9
2
2
2
1
1
1
n°
Led
1OA60021
1OA60020
1OA60019
1OA60021
1OA60020
1OA60019
cod.
Led Code
80
80
80
80
80
80
degrees
Emission Angle
2800-3200
3900-4500
5700-6500
2800-3200
3900-4500
5700-6500
K
Temp. colour
3
3
3
2,5
2,5
2,5
W
Power
450
450
450
700
700
700
mA
Current
155
170
200
115
135
150
lm
Minimum Luminous Flux
175
192
226
130
153
170
lux
Average ill. (60
cm)
10
GENERAL DATA:
Ta = 50°C
Tc (max) = 90°C
Life expectancy L70 : 50000 hours
SPOT LIGHT
55
CHARACTERISTICS OF THE SOURCE OF LIGHT
CHARACTERISTIC OF THE SOURCE OF LIGHT
Spot light with 1 LED 100 lmMIN @350 mA powered at 700 mA; 6000°K
Lumen emitted by the light
source
l [lm]
Emitted angle s.l.
Lens efficiency
ϑ/2 [°]
40,0
0,90
150,0
SPOT LIGHT
AVERAGE LUX DEPENDING ON: DISTANCE OF THE LIGHT SOURCE-SURFACE,
EMISSION ANGLE, LUMEN EMITTED
55
LIGHT CHARACTERISTICS GRAPH
AVERAGE LUX (H, lm, J)
Distance from surface
Lighted surface
Average Lux L (H, lm, J)
N°
H (1,5) [m]
S (1,5) [m2]
r (1,5) [m]
L [lux]
1
2
3
4
5
0,60
0,75
1,00
1,25
1,50
0,80
1,24
2,21
3,46
4,98
0,50
0,63
0,84
1,05
1,26
170
109
61
39
27
150,0 lm
170 lux
0,80 m2
109 lux
1,24 m2
61 lux
2,21 m2
0,60m
40°
0,75m
ϑ/2
1,00m
39 lux
3,46 m2
27 lux
4,98 m2
H5
1,25m
S5
1,50m
r5
Lux and Lumen are two different ways to meassure the flow of light. Lumen tells you the "Quantity"
of light. Lux is a value depending on an area. One Lumen is the light value of one sqm at one Lux,
the same on a area of one sqcm 10 000 Lux.
11
SPOT LIGHT
55
LIGHT CHARACTERISTICS GRAPH
AVERAGE LUX DEPENDING ON: DISTANCE OF THE LIGHT SOURCE-SURFACE,
EMISSION ANGLE, LUMEN EMITTED
CHARACTERISTIC OF THE SOURCE OF LIGHT
Spot light with 1 LED 80 lmMIN @350 mA powered at 700 mA; 3000°K
Lumen emitted by the light
source
l [lm]
Emitted angle s.l.
Lens efficiency
ϑ/2 [°]
40,0
0,90
115,0
AVERAGE LUX (H, lm, J)
Distance from surface
Lighted surface
Average Lux L (H, lm, J)
N°
H (1,5) [m]
S (1,5) [m2]
r (1,5) [m]
L [lux]
1
2
3
4
5
0,60
0,75
1,00
1,25
1,50
0,80
1,24
2,21
3,46
4,98
0,50
0,63
0,84
1,05
1,26
130
83
47
30
21
115,0 lm
130 lux
0,80 m2
83 lux
1,24 m2
47 lux
2,21 m2
0,60m
40°
0,75m
ϑ/2
1,00m
30 lux
3,46 m2
21 lux
4,98 m2
H5
1,25m
S5
1,50m
r5
Lux and Lumen are two different ways to meassure the flow of light. Lumen tells you the "Quantity"
of light. Lux is a value depending on an area. One Lumen is the light value of one sqm at one Lux,
the same on a area of one sqcm 10 000 Lux.
12
SPOT LIGHT
30
30
SPOT LIGHT
DOT SERIES LAMPS
Lamp with a LED lens made in IP54 or IP65 versions.
The main characteristic of this product is the possibility
to decide the angle of the light, choosing between
various types of lenses.
The total absence of the emission of UV rays and
thanks to the aluminium heat-sink a high level of heat
dissipation is guaranteed. External rings in different colours and finishes are available.
15
SPOT LIGHT
30
DOT SERIES - VERSION E
VERSION E - screw clamping
THROUGH HOLE
30,5
This particular lamp uses screw fixing system with milled washer. The maximum thickness of the panel that
the system is able to clamp is 13mm
PROPERTIES
Uses a LED lens. Easy screw fixing system using milled washer. Led high luminosity technology, long life and
available in different colours. Heat sink in aluminium studied for efficient heat elimination. Free end wire
connection with 35 cm standard length. Ring with external finish available in different colours. Standard
protection grade IP54. Protection grade IP65 supplied on request (with O-Ring). Total absence of UV
rays emission. Power supply with constant current (FEMTO LED COMELIT)
APPLICATION
On panels with thinkness under 13mm
NOTES
For correct usage of led lamp for your application please contact the Comelit technical staff
16
SPOT LIGHT
30
DOT SERIES - VERSION B
TAPE SPRING
VERSION B - tape spring for metallic panels
THROUGH HOLE
30,5 and ANTIROTATION
Tape spring guarantees hold and antirotation on metallic panel applications thickness up to 2mm
PROPERTIES
Uses a LED lens. Easy fixing with tape spring. Led high luminosity technology, long life and available in
different colours. Heat sink in aluminium studied for efficient heat elimination. Free wire connection with
35 cm standard length. Ring with external finish available in different colours. Standard protection
grade IP54. Protection grade IP65 supplied on request (with O-Ring). Total absecnce of UV rays
emission. Power supply with constant current (FEMTO LED COMELIT)
APPLICATION
On all sheet steel panels up to a thickness of 2mm
NOTES
For correct usage of led lamp for your application please contact Comelit technical staff
17
SPOT LIGHT
30
DOT SERIES - VERSION C
TAPE SPRING
VERSION C - tape spring with high thickness
THROUGH HOLE 30,5 AND DEAD HOLE H>29MM
Tape spring guarantees hold on applications with min. thickness 13mm panels with through hole. In
case of dead holes the depth of the hole must be at least 29mm
PROPERTIES
Uses a LED lens. Easy fixing system with tape spring. Led high luminosity technology, long life and available in different colours. Heat sink in aluminium studied for efficient heat elimination. Free wire connection with 35 cm standard lenght. Ring with external finish available in different colours. Standard
protection grade IP54. Protection grade IP65 supplied on request (with O-Ring). Total absence of
UV rays emission. Power supply with constant current (FEMTO LED COMELIT)
APPLICATION
On panels with thickness above 13mm
NOTES
For correct usage of led lamp for your application please contact the Comelit technical staff
18
20
SPOT LIGHT
25
25
SPOT LIGHT
MINIDOT SERIES LAMP
Lamps with LED lens made in only IP54 version, even on
this product it is possible to decide the angle of the
light, choosing between various types of lenses.
The total absence of the emission of UV rays is guaranteed. External rings in different colours and finishes
are available.
20
SPOT LIGHT
25
MINIDOT SERIES - VERSION B
TAPE SPRING
VERSION B - tape spring for metallic panels
THROUGH HOLE 26 AND ANTIROTATION
Tape spring guarantees hold and antirotation on metallic panel applications thickness up to 2mm
PROPERTIES
Uses a Led lens. Easy fixing system with tape spring. Led high luminosity technology, long life and available in different colours. Heat sink in aluminium studied for efficient heat elimination. Free wire connection
with 35 cm standard length. Ring with external finish available in different colours. Extremely small front
thickness of the external ring 1 mm. Standard protection grade IP54. Total absence of UV rays emission.
Power supply with constant current (FEMTO LED COMELIT)
APPLICATION
On all sheet steel panels up to a thickness of 2mm
NOTES
For correct usage of led lamp for your application please contact the Comelit technical staff
21
22
25
4
447 lux
0,26 m2
199 lux
0,59 m2
112 lux
1,05 m2
72 lux
1,64 m2
50 lux
2,36 m2
ϑ
60°
5
212 lux
0,55 m2
94 lux
1,24 m2
53 lux
2,21 m2
34 lux
3,46 m2
24 lux
4,98 m2
ϑ
80°
1125 lux
0,10 m2
500 lux
0,23 m2
281 lux
0,42 m2
180 lux
0,65 m2
125 lux
0,94 m2
ϑ
40°
3
LED LAMP 6000°K; 90° APERTURE ANGLE
3031 lux
0,04 m2
1347 lux
0,09 m2
758 lux
0,15 m2
485 lux
0,24 m2
337 lux
0,35 m2
ϑ
25°
2
8595 lux
0,01 m2
3820 lux
0,03 m2
2149 lux
0,05 m2
1375 lux
0,09 m2
995 lux
0,12 m2
ϑ
15°
1
130,0 lm
lumen emitted
ϑ/2
1,50 m
1,25 m
1,00 m
0,75 m
0,50 m
0m
distance from surface
AVERAGE LUX VARIES ACCORDING TO: emitted lumeni, distance between luminous source-surface, emission angle and lens efficiency
SPOT LIGHT
23
4
309 lux
0,26 m2
138 lux
0,59 m2
77 lux
1,05 m2
50 lux
1,64 m2
34 lux
2,36 m2
ϑ
60°
5
146 lux
0,55 m2
65 lux
1,24 m2
37 lux
2,21 m2
23 lux
3,46 m2
16 lux
4,98 m2
ϑ
80°
779 lux
0,10 m2
346 lux
0,23 m2
195 lux
0,42 m2
125 lux
0,65 m2
87 lux
0,94 m2
ϑ
40°
3
LED LAMP 3000°K; 90° APERTURE ANGLE
2098 lux
0,04 m2
933 lux
0,09 m2
525 lux
0,15 m2
336 lux
0,24 m2
233 lux
0,35 m2
ϑ
25°
2
5950 lux
0,01 m2
2645 lux
0,03 m2
1488 lux
0,05 m2
952 lux
0,09 m2
661 lux
0,12 m2
ϑ
15°
1
90,0 lm
lumen emitted
ϑ /2
SPOT LIGHT
25
1,50 m
1,25 m
1,00 m
0,75 m
0,50 m
0m
distance from surface
AVERAGE LUX VARIES ACCORDING TO: emitted lumeni, distance between luminous source-surface, emission angle and lens efficiency
SPOT LIGHT
25
LIGHT CHARACTERISTICS GRAPH
AVERAGE LUX VALUES DEPENDING ON: DISTANCE OF THE SOURCE OF
LIGHT TO THE LIGHTING AREA, THE ANGLE OF EMISSION AND THE NUMBER
OF LUMEN EMITTED
CHARACTERISTICS OF THE SOURCE OF LIGHT
Spot light 1 LED 80 lmMIN @350 mA powered at 700 mA; 6000°K
LUMEN EMITTED BY THE
LIGHT SOURCE
l [lm]
OVAL LENS EFFICIENCY
EMITTED ANGLE s.l.�
ϑ/2 [°]
22,5
130,0
ϑ/2 [°]
12,5
0,9
AVERAGE LUX (H, lm, θ)
Distance from surface
N°
H (1,5) [m]
Lighted Surface
S (1,5) [m2]
a (1,5) [m]
b (1,5) [m]
Average Lux
L (H, lm, ϑ)
L [lux]
1
0,50
0,07
0,21
0,11
2
0,75
0,16
0,31
0,17
3
1,00
0,29
0,41
0,22
4
1,25
0,45
0,52
0,28
5
1,50
0,65
0,62
0,33
* in case of the oval lens the emission angle considers two values ϑ/2 e ß/2
1622
721
406
260
180
130,0 lm
1622 lux
0,07 m2
721 lux
0,16 m2
0,50m
0,75m
406 lux
0,29 m2
1,00m
260 lux
0,45 m2
180 lux
0,65 m2
H5
1,25m
S5
a5
1,50m
b5
Projection on a flat surface
ϑ/2 = 22,5° ß/2 = 12,5°
Lux and Lumen are two different ways to meassure the flow of light. Lumen tells you the “Quantity”
of light. Lux is a value depending on an area. One Lumen is the light value of one sqm at one Lux,
the same on a area of one sqcm 10 000 Lux.
24
CHARACTERISTICS OF THE SOURCE OF LIGHT
Spot light 1 LED 67 lmMIN @350 mA powered at 700 mA; 3000°K
LUMEN EMITTED BY THE
LIGHT SOURCE
l [lm]
OVAL LENS EFFICIENCY
EMITTED ANGLE s.l.�
ϑ/2 [°]
22,5
130,0
ϑ/2 [°]
12,5
0,9
AVERAGE LUX (H, lm, θ)
Distance from surface
N°
H (1,5) [m]
Lighted Surface
S (1,5) [m2]
a (1,5) [m]
b (1,5) [m]
SPOT LIGHT
AVERAGE LUX VALUES DEPENDING ON: DISTANCE OF THE SOURCE OF
LIGHT TO THE LIGHTING AREA, THE ANGLE OF EMISSION AND THE NUMBER
OF LUMEN EMITTED
25
LIGHT CHARACTERISTICS GRAPH
Average Lux
L (H, lm, ϑ)
L [lux]
1
0,50
0,07
0,21
0,11
2
0,75
0,16
0,31
0,17
3
1,00
0,29
0,41
0,22
4
1,25
0,45
0,52
0,28
5
1,50
0,65
0,62
0,33
* in case of the oval lens the emission angle considers two values ϑ/2 e ß/2
1123
499
281
180
125
90,0 lm
1123 lux
0,07 m2
499 lux
0,16 m2
0,50m
0,75m
281 lux
0,29 m2
1,00m
180 lux
0,45 m2
125 lux
0,65 m2
H5
1,25m
S5
a5
1,50m
b5
Projection on a flat surface
ϑ/2 = 22,5° ß/2 = 12,5°
Lux and Lumen are two different ways to meassure the flow of light. Lumen tells you the “Quantity”
of light. Lux is a value depending on an area. One Lumen is the light value of one sqm at one Lux,
the same on a area of one sqcm 10 000 Lux.
25
PCB LED
PCB LED
PCB LED
A vast array of LED strips available in continuous
evolution and extension.
For every application, Comelit chooses the LED
with the best performance for the purpose.
The choice is made identifying the right LED to
be used, considering the application and the
working conditions and of the economic objective to be reached.
The thing that remains unchanged for all Comelit
LED strips is the care in the design and checks in
the manufacturing processes.
28
PCB LED
MPS Metal Core SERIES PCB STRIP [C80]
HIGH EFFICIENCY [HE] -700 mA
SERIES
LED N°
TEMP. COLOUR °K
POWER [W]
LUMEN MIN
MPS C
MPS F
MPS D
MPS C
MPS F
MPS D
MPS C
MPS F
MPS D
5
4
3
5
4
3
5
4
3
3000
3000
3000
4000
4000
4000
6000
6000
6000
11
9
6,6
11
9
6,6
11
9
6,6
580
470
350
680
540
410
780
620
470
PROPERTIES
Ambient Temperature 0 ÷ 50° C. (*) = Power through current generator [SE] 350mA [HE] 700mA.
All values measured at ta=25°C. Life projection of the Led atTc=80°C > 30 000 hours. Do not
exceed the Tc temperature (if the maximum temperature is exceeded, the life of the module is greatly
reduced). High power LED. Dimmable by pulse with modulation (PWM). Broad 90° light distribution for
uniform illumination. Polarity reverse protection. Connection method: connectors (see drawing). Wiring
of extensions with special connectors supplied by Comelit. Connection to the heatsink by screws or
adhesive conductive tapes.
APPLICATIONS
Safety lighting, general lighting, effect lighting and shelf lighting
NOTES
Please contact the technical offices of Comelit spa if you have a question about the correct use of
the Metal Core PCB Strip
29
PCB LED
MPS Metal Core SERIES PCB STRIP [CC5]
HIGH EFFICIENCY [HE] -700 mA
SERIES
LED N°
TEMP. COLOUR °K
POWER [W]
LUMEN MIN
MPS A
MPS B
MPS A
MPS B
5
3
5
3
3000
3000
6000
6000
12,5
7,5
12,5
7,5
500
300
700
420
PROPERTIES
Ambient Temperature 0 ÷ 50° C. (*) = Power through current generator [SE] 350mA [HE] 700mA.
All values measured at ta=25°C. Life projection of the Led atTc=80°C > 30 000 hours. Do not
exceed the Tc temperature (if the maximum temperature is exceeded, the life of the module is greatly
reduced). High power LED. Dimmable by pulse with modulation (PWM). Broad 90° light distribution for
uniform illumination. Polarity reverse protection. Connection method: connectors (see drawing). Wiring
of extensions with special connectors supplied by Comelit. Connection to the heatsink by screws or
adhesive conductive tapes.
APPLICATIONS
Safety lighting, general lighting, effect lighting and shelf lighting
NOTES
Please contact the technical offices of Comelit spa if you have a question about the correct use of
the Metal Core PCB Strip
30
ALUMINIUM PROFILES / TUBES
Detail of bar connection system for assembling in series
Detail of connection for corners
Profile fixing through brackets screwed on the wall
ALUMINIUM PROFILES / TUBES
EXTRUDED PROFILE H=20mm H=26mm
Connection example between profiles through direct cable
(see standard connection)
Connection example between profiles through MULTIPLUG [S2]
(see standard connection)
Beyond different kind of LEDs, it is possible to choose between
transparent and opalescent screen
33
ALUMINIUM PROFILES / TUBES
EXTRUDED PROFILE H=20mm H=26mm
extruded profile H=20
for PCB FLEX
closed end piece
for end of profile H20/H26
blocking plaque
closed end piece
2x screws 2.2x6.5mm
34
extruded profile H=26
for PCB STRIP and/or PCB FLEX
end piece with through hole for cable for power
supply and/or extensions profiles H20/H26
fixing plaque
min n°2 every profile
hole for screw
3,5
blocking plaque
end piece with through
hole for cable
2x screws 2.2x6.5mm
ALUMINIUM PROFILES / TUBES
ALUMINIUM PROFILES / TUBES
Cable-holding nut with washer
Water-tight end cover with o-ring
Fixing brackets
37
ALUMINIUM PROFILES / TUBES
IP67 LED TUBES
Inside the polycarbonate tube an aluminium bar (H=26) is installed on which are applied the LEDs.
Base on the requirements of the user, it is possible to install any type of LED obtaining in this way a
highly functional product and extremely flexible for diverse applications. The length of the tube “L”
varies based on the number and type of LED to be used. Its design concept allows the user to direct
the light even after installation, the possibility to rotate by 360° gives the possibility to obtain the best
lighting for the application. For these characteristics we described above, this product is highly recommended for all installations in open air and in environments where there is the presence of dust and
water vapour (eg. warehouses, industrial kitchens, etc.). To the end of presenting a product of a high
quality standard, Comelit has certified its grade of IP67 protection (IEC 60529).
CHARACTERISTICS
Tube in transparent polycarbonate.
Input cable with double sheathing in PVC or neoprene for outdoor use.
Input end cover in grey plastic with PG for holding the cable.
Closing end cover in grey plastic.
Possibility for connecting further tubes using two input end covers with PG.
Standard grade of protection IP67.
APPLICATIONS
Outdoors, wet or dusty environments, presence of chemical agents etc.
NOTES
Please contact Comelit’s technical department for the correct use of our LED tube in your application
38
STANDARD CONNECTORS
STANDARD CONNECTORS
Connectors
Multi-plug connectors
Bar connection system
41
CURRENT GENERATORS FOR LED
CURRENT GENERATORS FOR LED
CURRENT GENERATOR
n° 1 LED max (700mA) - Model ALD070045E
Case
Polymer PA6.6 -V0
Standard colour WHITE
Input / Output
Terminal block 2 poles
Wire sec. 0,5 ÷ 1,5 mm ²
INPUT SPECIFICATIONS
Voltage
Frequency
Current input
Peak current
Protection
230 (Vac)
50/60 (Hz)
70 (mA)
< 30 (A) @ 25 °C
fuse track and wire resistor
OUTPUT SPECIFICATIONS
Voltage max
LED power supply
Power
Input variation
Load variation
Ripple
Protection
4,5 (Vdc) ± 5%
0,7 (A)
3,15 (W)
< 0,5%
< 4%
< 150 (mV) @ 20 mHz
short circuit
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
Switching frequency
Hold-up-time
Dielectric strenght I/O
Leakage current
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
120 (KHz)
> 40 (msec) @ 90 Vac 50 Hz
3750 Vac
< 0,2 (mA)
50000 (h)
REFERENCE STANDARDS
Safety
EMC
Emission immunity
NOTES
SYMBOLS
44
EN 61347-1
EN 61347-2-13
EN 61547 ; EN 55015
Case
Polymer PA6 -V2
Standard colour
GREY RAL 7035
Input / Output
Terminal block 2 poles
Wire sec. 0,5 ÷ 1,5 mm ²
INPUT SPECIFICATIONS
Voltage
Frequency
Current input
Peak current
Protection
230 (Vac)
50/60 (Hz)
150 (mA)
< 30 (A) @ 25 °C
fuse track and wire resistor
CURRENT GENERATORS FOR LED
CURRENT GENERATOR
from 2 to 6 LED max (700mA) - Model ALD070250E
OUTPUT SPECIFICATIONS
Voltage max
LED power supply
Power
Input variation
Load variation
Ripple
Protection
25 (Vdc) ± 5%
0,7 (A)
17,5 (W)
< 0,5%
< 4%
< 150 (mV) @ 20 mHz
short circuit
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
Switching frequency
Hold-up-time
Dielectric strenght I/O
Leakage current
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
120 (KHz)
> 40 (msec) @ 90 Vac 50 Hz
3750 Vac
< 0,2 (mA)
100000 (h)
REFERENCE STANDARDS
Safety
EMC
Emission immunity
EN 61347-1
EN 61347-2-13
EN 61547 ; EN 55015
NOTES
for input / output cable it is advisable in order to guarantee the functioning of the strain relief to use: H03VVH2-F 2x0,75
mm
SYMBOLS
45
CURRENT GENERATORS FOR LED
CURRENT GENERATOR
from 2 to 6 LED max (700mA) - Model ALD070250A
Case
Polymer PA6 -V2
standard colour
GREY RAL 7035
Input / Output
Terminal block 2 poles
wire sec. 0,5 ÷ 1,5
INPUT SPECIFICATIONS
Voltage
Frequency
Current input
Peak current
Protection
120 (Vac)
50/60 (Hz)
300 (mA)
< 30 (A) @ 25 °C
fuse track and wire resistor
OUTPUT SPECIFICATIONS
Voltage max
LED power supply
Power
Input variation
Load variation
Ripple
Protection
25 (Vdc) ± 5%
0,7 (A)
17,5 (W)
< 0,5%
< 4%
< 150 (mV) @ 20 mHz
short circuit
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
Switching frequency
Hold-up-time
Dielectric strenght I/O
Leakage current
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
120 (KHz)
> 40 (msec) @ 90 Vac 50 Hz
3750 Vac
< 0,2 (mA)
100000 (h)
REFERENCE STANDARDS
Safety
EMC
Emission immunity
EN 61347-1
EN 61347-2-13
EN 61547 ; EN 55015
NOTES
for input / output cable it is advisable in order to guarantee the functioning of the strain relief to use: H03VVH2-F 2x0,75
mm
SYMBOLS
46
Case
Polymer PA6 -V2
Standard colour
GREY RAL 7035
Input / Output
Terminal block 2 poles
wire sec. 0,5 ÷ 1,5 mm ²
INPUT SPECIFICATIONS
Voltage
Frequency
Current input
Peak current
Protection
230 (Vac)
50/60 (Hz)
150 (mA)
< 30 (A) @ 25 °C
fuse track and wire resistor
CURRENT GENERATORS FOR LED
CURRENT GENERATOR
from 2 to 9 LED max (500mA) - Model ALD050320E
OUTPUT SPECIFICATIONS
Voltage max
LED power supply
Power
Input variation
Load variation
Ripple
Protection
32 (Vdc) ± 5%
0,5 (A)
16,0 (W)
< 0,5%
< 4%
< 150 (mV) @ 20 mHz
short circuit
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
Switching frequency
Hold-up-time
Dielectric strenght I/O
Leakage current
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
120 (KHz)
> 40 (msec) @ 90 Vac 50 Hz
3750 Vac
< 0,2 (mA)
100000 (h)
REFERENCE STANDARDS
Safety
EMC
Emission immunity
EN 61347-1
EN 61347-2-13
EN 61547 ; EN 55015
NOTES
for input / output cable it is advisable in order to guarantee the functioning of the strain relief to use: H03VVH2-F 2x0,75
mm
SYMBOLS
47
CURRENT GENERATORS FOR LED
CURRENT GENERATOR
from 3 to 15 LED max - Model ALS5807E
Case
Polymer PA6 -V2
standard colour
GREY RAL 7035
Input / Output
Terminal block 2/4 poles
wire sec. 0,5 ÷ 2,5 mm ²
INPUT SPECIFICATIONS
Voltage
Frequency
Current input
Peak current
Protection
230 (Vac)
50/60 (Hz)
400 (mA)
< 30 (A) @ 25 °C
fuse track and wire resistor
OUTPUT SPECIFICATIONS
Voltage max
LED power supply
Power
Input variation
Load variation
Ripple
Protection
60 (Vdc) ± 5%
0,7 (A)
40,0 (W)
< 0,5%
< 4%
< 150 (mV) @ 20 mHz
short circuit
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
Switching frequency
Hold-up-time
Dielectric strenght I/O
Leakage current
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
120 (KHz)
> 40 (msec) @ 90 Vac 50 Hz
3750 Vac
< 0,2 (mA)
50000 (h)
REFERENCE STANDARDS
Safety
EMC
Emission immunity
NOTES
SYMBOLS
48
EN 61347-1
EN 61347-2-13
EN 61547 ; EN 55015
POWER SUPPLY AC/DC PER LED
Power Supply
AC/DC 230Vac/24Vdc 96W - AC/DC 230Vac/48Vdc 96W
MODEL
DC VOLTAGE
CONSTANT CURRENT REGION
RATED CURRENT
48 V
18-24 V
36-48 V
4A
2A
96 W
RIPPLE & NOISE (Max)
150 mVp-p
200 mVp-p
VOLTAGE ADJ RANGE (SVR1)
20,4-24 V
40,8-48 V
CURRENT ADJ RANGE (SVR2)
3-4 A
1,5-2 A
VOLTAGE TOLLERANCE
±3,0%
LINE REGULATION
SETUP, RISE TIME
±2,0%
1200 ms, 80 ms/230VAC - 1200 ms, 80 ms/115VAC at full load
HOLD UP TIME (Typ.)
60 ms/230VAC 30 ms/115VAC at full load
VOLTAGE RANGE
90-264 vac 127-370 VDC
FREQUENCY RANGE
47 - 63 Hz
POWER FACTOR (Typ)
PF>0,95/230VAC PF>0,95/115VAC at full load PF≥0,9 AT 75 - 100% load
EFFICIENCY (Typ)
AC CURRENT (Typ)
87%
COLD START 40A / 230VAC
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP
WORKING HUMIDITY
ENVIRONMENT
95-102%
Protection type constant current limiting recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
27-34 V
52-64 V
Protection type: shut down and latch off o/p voltage, re-power on to recover
90°C±10°C (RTH2)
Protection type: shut down o/p voltage, re-power on to recover
-30 +50°C (refer to output load derating curve)
20 - 95% RH non-condensing
-40 +80°C, 10 - 95% RH
TEMP COEFFICIENT
±0,03% / °C (0 - 50 °C)
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
50
<0,75 mA / 240 VAC
STORAGE TEMP, HUMIDITY
VIBRATION
SAFETY & EMC
87%
12V:0,8A/115VAC 0,4A/230VAC 15V:0,9A/115VAC 0,45A/230VAC 20V 48V:1,1A/115VAC 0,55A/230VAC
INRUSH CURRENT (Typ)
PROTECTION
±2,0%
±1,0%
LOAD REGULATION
INPUT
PLN-100-48
24 V
96 W
RATED POWER
OUTPUT
PLN-100-24
10 - 500Hz, 2G 12min/1 cycle, period for 72 min each along X, Y, Z axes
UL1310 Class 2, EN61347-1, EN61347-2-13 indipendent, UL60950-1, TUV EN 60950-1,
UL879 (listed in UL Sign Components Manual SAM CAN/CSA C22.2 No. 223-M91 except for
48V, IP64 approved)
I/P-O/P:3,75KVAC I/P-FG:1,88KVAC O/P-FG 0,5KVAC
I/P-O/P:100M Ohms / 500VDC / 25°C / 70%RH
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C (>75% load); EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, light industry level (surge
4KV) criteria A
MODEL
DC VOLTAGE
CONSTANT CURRENT REGION
PLN-60-24
48 V
16,8-24 V
33,6-48 V
RATED CURRENT
2,5 A
1,3 A
CURRENT RANGE
0 - 2,5 A
0 -1,3 A
RATED POWER
RIPPLE & NOISE (max)
OUTPUT
VOLTAGE ADJ, RANGE
CURRENT ADJ RANGE
60W
62,5W
2,7 Vp-p
4,6 Vp-p
24-26V
43,6-51,8V
Can be adjusted by internal potential meter SVR1
3% -25% Can be adjusted by internal potential meter SVR2
VOLTAGE TOLERANCE
±10%
LINE REGULATION
±3,0%
LOAD REGULATION
SETUP, RISE TIME
±5,0%
1500 ms / 230VAC - 3000 ms / 115VAC at full load
VOLTAGE RANGE
90-264 vac 127-370 VDC
FREQUENCY RANGE
POWER FACTOR
INPUT
EFFICIENCY (Typ)
47 - 63 Hz
PF≥0,9 at 75 - 100% load, 115VAC / 230VAC
86%
AC CURRENT
40A / 230VAC
LEAKAGE CURRENT
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP
WORKING HUMIDITY
ENVIRONMENT
<0,75 mA / 240 VAC
95-102%
110% (max)
Protection type constant current limiting recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
28-32 V
54-60 V
Protection type: shut down o/p voltage, re-power on to recover
90°C±10°C (tsw1) detect on heatsink of power transitor
Protection type: shut down o/p voltage, recovers automatically after temperature goes down
-30 +50°C (refer to output load derating curve)
20 - 95% RH non-condensing
STORAGE TEMP, HUMIDITY
-40 +80°C, 10 - 95% RH
TEMP COEFFICIENT
±0,03% / °C (0 - 50 °C)
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & EMC
87%
0,8A/115VAC - 0,4A/230VAC
INRUSH CURRENT (Max)
PROTECTION
PLN-60-48
24 V
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
POWER SUPPLY AC/DC PER LED
Power Supply
AC/DC 230Vac/24Vdc 60W - AC/DC 230Vac/48Vdc 60W
10 - 500Hz, 2G 12min/1 cycle, period for 72 min each along X, Y, Z axes
UL1310 Class 2, TUV EN 61347-1, EN 61347-2-13, CAN/CSA C22.2 No. 223-M91 except
for 48V, IP64 approved)
I/P-O/P:3,75KVAC I/P-FG:1,88KVAC O/P-FG 0,5KVAC
I/P-O/P:100M Ohms / 500VDC / 25°C / 70%RH
Compliance to EN55015, EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class C (>75% load); EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, light industry level (surge
4KV) criteria A
51
CONSTANT CURRENT LED DRIVER
CONSTANT CURRENT LED DRIVER
CONSTANT CURRENT LED DRIVER
from 2 to 12 led max INPUT 8 ÷ 48 Vdc 700mA
Input (A)
el. cable outside 3,6mm grey
2x sec. 0,34 mm ² BI-MA
Output (B)
el. cable outside 3,6mm grey
Connection Plug
Housing / partition
alluminium bar H26
opaque cover
Accessories
Mounting Plate
STEP-DOWN VOLTAGE REGULATION UNIT DESIGNED TO OPERATE AND REGULATE
HIGH POWER LED
All values are based on a room temperature of 25°C
INPUT SPECIFICATIONS
Voltage
Input filter
Protection
8÷48 (Vdc)
Capacitive
Protection diode against polarity inversion
OUTPUT SPECIFICATIONS
Voltage
LED power supply
Max Power
LED power supply stability @ max load
Power LED current tolerance @ max load
Efficiency @ max load
Short circuit protection
3÷44 (Vdc)
0,7 (A)
30,0 (W)
± 1% max
± 2% max
96% max
Voltage regulation on nominal values
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
Switching frequency
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
150 (KHz)
100000 (h)
NOTES
All connections of the side A must be done before electrical power is applied
It is not allowed disruppt the connection between the power supply unit and the side A
In case the system is connected to a battery, a peak current protection has to be provided
SYMBOLS
54
from 2 to 12 led max INPUT 8 ÷ 48Vdc 700 mA
Input (A)
el. cable outside 3,6mm grey
2x sec. 0,34 mm ² BI-MA
Output (B)
el. cable outside 3,6mm grey
Connection Plug
Housing / partition
alluminium bar H26
opaque cover
Accessories
Mounting Plate
CONSTANT CURRENT LED DRIVER
CONSTANT CURRENT LED DRIVER-LIGHT SENSOR
STEP-DOWN VOLTAGE REGULATION UNIT DESIGNED TO OPERATE AND REGULATE
HIGH POWER LED
All values are based on a room temperature of 25°C
INPUT SPECIFICATIONS
Voltage
Input filter
Protection
8÷48 (Vdc)
Capacitive
Protection diode against polarity inversion
OUTPUT SPECIFICATIONS
Voltage
LED power supply
Max Power
LED power supply stability @ max load
Power LED current tolerance @ max load
Efficiency @ max load
Short circuit protection
3÷44 (Vdc)
0,7 (A)
30,0 (W)
± 1% max
± 2% max
96% max
Voltage regulation on nominal values
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
Switching frequency
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
150 (KHz)
100000 (h)
NOTES
All connections of the side A must be done before electrical power is applied
It is not allowed disruppt the connection between the power supply unit and the side A
In case the system is connected to a battery, a peak current protection has to be provided
SYMBOLS
55
CONSTANT CURRENT LED DRIVER DIMMER
CONSTANT CURRENT LED DRIVER
from 2 to 12 led max INPUT 8 ÷ 48 Vdc 700mA
Input (A)
el. cable outside 3,6mm grey
2x sec. 0,34 mm ² BI-MA
Output (B)
el. cable est 3,6mm grey
Connection Plug
Housing / partition
alluminium bar H26
smoked cover
Accessories
Mounting Plate
STEP-DOWN VOLTAGE REGULATION UNIT DESIGNED TO OPERATE AND REGULATE
HIGH POWER LED
All values are based on a room temperature of 25°C
INPUT SPECIFICATIONS
Voltage
Input filter
Protection
8÷48 (Vdc)
Capacitivo
Protection diode against polarity charge
OUTPUT SPECIFICATIONS
Voltage
LED power supply
Max Power
LED power supply stability @ max load
Power LED current tolerance @ max load
Efficiency @ max load
Short circuit protection
3÷44 (Vdc)
0,7 (A)
30,0 (W)
± 1% max
± 2% max
96% max
Voltage regulation on nominal values
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
Switching frequency
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
150 (KHz)
100000 (h)
NOTES
All connections of the side A must be done before electrical power is applied
It is not allowed to disrupt the connection between the power supply unit and the side A
In case the system is connected to a battery, a peak current protection has to be provided
SYMBOLS
56
strip Led 12 ÷ 24 Vdc INPUT 12 ÷ 24 Vdc
Input (A)
el. cable outside 3,6mm grey
2x sec. 0,34 mm ² BI-MA
Output (B)
el. cable outside 3,6mm grey
2x sec. 0,34 mm ² BI-MA
Housing / partition
alluminium bar H26
smoked cover
Accessories
Mounting Plate
CONSTANT CURRENT LED DRIVER
DIMMER WITH MEMORY
STEP-DOWN VOLTAGE REGULATION UNIT DESIGNED TO OPERATE AND REGULATE
HIGH POWER LED
All values are based on a room temperature of 25°C
INPUT SPECIFICATIONS
Voltage
Input filter
Protection
12÷24 (Vdc)
Not present
Protection diode against polarity charge
OUTPUT SPECIFICATIONS
Voltage
Rugulation
Max Power
Short circuit protection
12÷24 (Vdc)
PWM 0÷100% Duty Cycle
2 (A)
Not present
GENERAL SPECIFICATIONS
Operating temperature
Storage temperature
No load voltage
Humidity
MTBF
0 ÷ 40 (°C)
0 ÷ 60 (°C)
< 0,5 (W)
90 (%)
100000 (h)
NOTES
All connections of the side A must be done before electrical power is applied
It is not allowed to disrupt the connection between the power supply unit and the side A
In case the system is connected to a battery, a peak current protection has to be provided
SYMBOLS
57
NOTE
NOTE
via Maestri del Lavoro 1
I - 60022 Castelfidardo An
tel. +39 071 782491
fax +39 071 7824923
info@comelit.com
www.comelit.com
LED SYSTEM
Graphic design, layout and cover design:
YOURPARTNERS - Comunicazione, Grafica, Web
Photography:
Alessandro Cattabrini
Technical graphs:
Comelit technical study
All rights reserved. Not allowed to be reproduced in any
form or by any means, including photocopying, recording
and processing information, without authorization of the
copyright holder.
The specifications given in this catalog are subject to possible change without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising