US Part Number: F3531 - Digi-Star

US Part Number: F3531 - Digi-Star
US Part Number: F3531
Digi-Star EZ2000/EZ2000V
Table of contents
Table of contents
1. About the product.............................................................................................................................. 1
1.1 Features of Models EZ2000 and EZ2000V............................................................................... 1
1.2 Operating specifications............................................................................................................ 1
1.3 Housing ...................................................................................................................................... 1
2. System operation............................................................................................................................... 2
TURNING ON THE SCALE ............................................................................................................ 2
TURNING OFF THE SCALE .......................................................................................................... 2
TO ZERO BALANCE THE SCALE ................................................................................................. 2
TO SELECT GROSS MODE ............................................................................................................ 3
TO SELECT NET MODE ................................................................................................................. 3
TO SELECT HOLD MODE .............................................................................................................. 3
TO EXIT HOLD MODE.................................................................................................................... 4
TO CANCEL HOLD MODE ............................................................................................................. 4
USING FUNCTION&SELECT KEYS............................................................................................. 4
ADD WEIGHT TO WEIGH MEMORY............................................................................................ 5
RECALL WEIGH MEMORY............................................................................................................ 5
PRINT WEIGHT MEMORY............................................................................................................. 5
CLEAR WEIGH MEMORY .............................................................................................................. 5
WEIGH AVERAGING ...................................................................................................................... 6
TO PRINT (OPTIONAL FEATURE) ............................................................................................... 6
REMOTE DISPLAY OPTION .......................................................................................................... 6
TR OPTION: RADIO CONTROL ..................................................................................................... 6
TO START THE MIXER TIMER ..................................................................................................... 7
TO CLEAR THE MIX TIMER ALARM ........................................................................................... 7
TO RESTART THE MIX TIMER ..................................................................................................... 7
3. Mounting and connection ................................................................................................................. 8
INDICATOR MOUNTING ............................................................................................................... 8
POWER CONNECTION................................................................................................................... 8
LOADCELL CONNECTION ............................................................................................................ 8
LIGHTNING PROTECTION ........................................................................................................... 9
TECHNICAL MANUAL ................................................................................................................... 9
CALIBRATION ................................................................................................................................. 9
4. Adjusting indicator to match another scale .................................................................................. 10
CONNECTING EZ INDICATOR TO OTHER LOAD CELLS ..................................................... 11
TO CHANGE SETUP & CALIBRATION NUMBERS ................................................................. 11
TO RETURN TO WEIGH MODE .................................................................................................. 12
Always keep this manual by your scale indicator
All rights reserved. Reproduction of any part of this manual in any form whatsoever without Digi-Star’s express written permission is
forbidden. The contents of this manual are subject to change without notice. All efforts have been made to assure the accuracy of the
contents of this manual. However, should any errors be detected, Digi-Star would greatly appreciate being informed of them. The above
notwithstanding, Digi-Star can assume no responsibility for any errors in this manual or their consequence.
Copyright ! 2000 Digi-Star.
Fort Atkinson, Wisconsin (USA)
Digi-Star Model EZ2000/EZ2000V
1. About the product
1. About the product
1.1 Features of Models EZ2000 and EZ2000V
"
"
"
"
"
"
"
"
Scrolling Help Messages for easy operation
Large 1.7" display (1" for EZ2000) for greater readability
Front panel calibration without simulator or weights
Expanded self diagnostic test capability
SELECT and FUNCTION keys to simplify appearance and allow for future expansion
A HOLD feature to hold the weight stable while moving the scale system
Fiber-optic back lighting for extremely long life
New powerful microprocessor and expanded memory
1.2 Operating specifications
"
"
"
"
Temperature range:
Power requirements:
Power on:
Power off:
-20#F to 140#F
10.2Vdc - 16Vdc
160mA, 4L.C. 350$
1mA
1.3 Housing
"
"
"
"
"
Size (l×h×w):
Weight (unpacked):
Display EZ2000:
10" × 7.4" × 5"
4.5 lbs
6-digit alpha numeric LCD, fiberoptic back lighting
Display height EZ2000 = 1"
Display height EZ2000V = 1.7"
Environmental enclosure: IP65, IEC529
Connectors:
AMP, gold plated contacts
1
Digi-Star Model EZ2000/EZ2000V
2. System operation
2. System operation
!
!
EZ2000 shown - EZ2000V operation is the same.
LB and KG annunciators are located along right hand edge of the 2000V display.
TURNING ON THE SCALE
Press
.
A brief message will be displayed (such as HELLO).
The scale then enters the GROSS weighing mode.
HELLO
GROSS mode displays the weight change since the
unit was last ZERO/BALANCED.
a second time during normal system
Pressing
operation starts the self test.
TURNING OFF THE SCALE
TO ZERO BALANCE THE SCALE
2
ZERO
1
Press
.
Press
and then within three seconds, press
.
The ZERO key will "balance off" empty trailer, bin,
or platform weight.
The ZERO message is displayed and the scale is
placed in the GROSS mode.
Pressing only the ZERO key will cause the
message: TO ZERO/BALANCE PRESS NET/ GROSS - THEN ZERO
to be displayed.
If the supply power is below the low battery
threshold (10.5 Volts),the message INDICATOR CANNOT BE
ZERO/BALANCED-LOW BATTERY VOLTAGE is displayed. The
message LO BAT will be periodically shown on the
display (approx. every five seconds) to alert the
operator of the low battery condition.
Loss of power does not affect the Zero/Balance or
Setup/Calibration values.
2
Digi-Star Model EZ2000/EZ2000V
TO SELECT GROSS MODE
2. System operation
GROSS mode displays the weight change
since the unit was last Zero/Balanced.
Press
9850
%
TO SELECT NET MODE
%
0
.
!
The scale is in GROSS mode if there is a
flashing arrow (% ) pointing toward the word
Gross, next to the display.
NET mode displays the weight change after a
TARE has been performed. TARE creates a
temporary zero at that weight value.
Press
to set a temporary "zero" point and
enter the NET mode.
or
if in GROSS mode, press
.
The NET/GROSS key is an alternating action key.
If the scale is in the GROSS mode, pressing the
NET/GROSS key will place it in the NET mode. If
the scale is in the NET mode, pressing the
NET/GROSS key will place it in the GROSS mode.
If the TARE function has not been previously
performed, the unit will stay in the GROSS mode
and the message FOR NET MODE PRESS TARE will scroll
across the display.
! The scale is in NET mode if there is a flashing
arrow (% ) pointing toward the word Net, next to
the display.
TO SELECT HOLD MODE
HOLD
HOLD mode prevents the displayed weight
from changing due to “zero shift” while
moving the scale. Use of this mode is
optional.
Press
to "hold" the displayed weight and
enter the HOLD mode.
! The scale is in HOLD mode if the word HOLD is
flashing on the display and the flashing HOLD WEIGHT
is only displayed for a brief time.
3
Digi-Star Model EZ2000/EZ2000V
2. System operation
TO EXIT HOLD MODE
Press
At this time the scale adjusts the Zero/Balance to
maintain the gross weight displayed. Small
changes in weight can occur while moving the
scale system to new locations for loading or
unloading. This change us called "zero shift" and
is due to several factors including terrain changes
and mechanical stresses.
9850
TO CANCEL HOLD MODE
Press
.
Cancelling the Hold mode prevents the scale from
adjusting the Zero/Balance and returns the system
to the normal weighing mode. Use this if you
choose Hold Mode in error.
HOLD
USING FUNCTION & SELECT KEYS
HOLD
.
The FUNCTION key provides additional features
to the operation of the scale. The FUNCTION key
is similar to the F1 key of a computer. The
SELECT key is used to determine what operation
will occur when the FUNCTION key is pressed.
2
to display the current operation of the
Press
1 FUNCTION key.
Continue to press
is displayed.
until the desired operation
! The FUNCTION key maintains this operation
until
is pressed again.
Now press the
operation.
key to perform the displayed
For example, if the word TIMER is displayed, then pressing the FUNCTION key will activate the
Mix Timer. If the message M+ is displayed, then pressing the FUNCTION key will cause the scale
to perform the Memory Plus (M+) operation.
The FUNCTION key operation is stored in non-volatile memory. This allows the scale to
remember the operation of the FUNCTION key even when the unit is turned OFF.
Press the SELECT key once to display the operation currently assigned to the FUNCTION key.
4
Digi-Star Model EZ2000/EZ2000V
2. System operation
ADD WEIGHT TO WEIGH MEMORY
Press the
key to assign the M+ operation to
the FUNCTION key.
key to perform the Memory Plus
Press the
(M+) operation.
M+
2
1
RECALL WEIGH MEMORY
Press the
key to assign the RM operation to
the FUNCTION key.
key to perform the Recall Memory
Press the
(RM) operation.
RM
2
1
PRINT WEIGH MEMORY (OPTION)
9850
The total amount stored in weigh memory will be
displayed.
Press the
(RM) value.
2
key to display the Recall Memory
Then press the
is still displayed.
1
CLEAR WEIGH MEMORY
CM
M+ will be displayed, followed by the amount to be
added to the weigh memory. RM will be displayed
next, followed by the total amount stored in the
weigh memory.
(Optional RM & M+ Keys on the 2000V - See Front
Cover Image).
key while the weigh memory
The PRINT key causes the unit to print the weigh
memory and return to the normal weighing modes.
Press the
key to assign the CM operation to
the FUNCTION key.
key to perform the Clear Memory
Press the
(CM) operation.
2
1
5
Digi-Star Model EZ2000/EZ2000V
2. System operation
WEIGH AVERAGING
RM
Press
key to assign the RM operation to the
FUNCTION key.
key twice within three seconds to
Press the
perform
the
weigh
averaging operation.
2×
2
1
The COUNT or number of weight values added to the
weigh memory will be displayed first. Then the
message AVERAG is displayed, followed by the
average weight value.
To print the average weight value, press the
key while the average weight is still displayed.
1258
Average weight print sample shown below:
10JA00 12:01P
5CT 1258LB AV
TO PRINT: (OPTIONAL FEATURE)
9850
Press the
printer.
key. Scale data will be sent to the
The weight will be printed automatically whenever
the TR is used.
Sample output format shown below:
10JA00 12:01P
123456LB GR
REMOTE DISPLAY (OPTION)
A Remote Display is available for viewing weights
at convenient locations. The Remote Display
includes a visual alarm light which can be used
with the TR option listed below.
TR OPTION: RADIO CONTROL
The transmitter/Receiver (TR) option uses a small
hand held transmitter to allow the operator to
remotely control the scale. The TR option allows
the operator to perform TARE and GROSS
functions.
6
Digi-Star Model EZ2000/EZ2000V
2. System operation
TO START THE MIXER TIMER
00:05:00
Press the
key to assign the TIMER operation
to the FUNCTION key.
Then press the
currently set.
3
2
1
key to see the Mix Time
While the Mix Time is displayed and a number is
flashing, the FUNCTION and SELECT keys can
be used to change the displayed value.
) increments the “flashing”
The SELECT key (
) selects which
digit and the FUNCTION key (
digit of the display is flashing.
key. Once the correct time has
Now press the
been entered or if the time displayed is acceptable,
stores the time and starts the Mix
pressing
Timer.
The display now reads HOURS, MINUTES and
SECONDS (HH:MM:SS), separated by colons that
flash every second.
The Mix Timer “counts downward” until 00:00:00
time is displayed. At this time, the alarms are
activated and the display begins flashing. This
continues until the Mix Timer Alarm is cleared
TO CLEAR THE MIX TIMER ALARM
9850
1
Press the
key or the
key. The scale clears
the Mix Timer alarms and enters the weighing
mode.
or
1
TO RESTART THE MIX TIMER
9850
Press the
key followed by the
key to start
the Mix Timer using the time previously entered.
2
1
7
Digi-Star Model EZ2000/EZ2000V
3. Mounting and connection
3. Mounting and connection
INDICATOR MOUNTING
LOAD CELL CONNECTION
The indicator is easily attached to the
Indicator Mounting Bracket by hooking the
top over the plate and securing the bottom
with two (2) bolts (size# 10 x 24 x 3/4") and
nuts.
The indicator is designed to operate with
strain gage load cells. The system will
normally be supplied with a “J-BOX” cable
going between the indicator and the load cell
junction box. Extension Kits are available
from your dealer in various lengths.
To connect the load cells, attach the junction
box cable to the J902 connector on the
bottom panel of the scale. Connect the load
cell cables to the junction box as shown
below.
POWER CONNECTION
Warning!
Always disconnect the indicator power cord
before “jump starting” or fast charging a
battery.
Disconnect all indicator leads before
welding on equipment. Failure to do so can
cause surges which will damage the scale.
The power cable should be connected
directly to a vehicle battery or regulated
power supply. The scale end of the power
cable is attached to the J901 connector
located on the bottom panel of the scale.
Connect the RED wire from the power
cable to +12VDC and the BLACK wire to
GROUND. The indicator is fused
internally at 4 amps.
Wire Color
RED
BLACK
ORANGE
BLUE
Wire Function
Battery (+12Vdc)
GROUND
NA
NA
Terminal Color
WHITE
GREEN
RED
BLACK
SHIELD
Description
SIGNAL +
SIGNAL EXCITATION +
EXCITATION SHIELD
! Follow color key on circuit board to insure
proper connection of load cell wires.
Serial
Port
Cable
(Optional)
Remote Junction Power
Display
Box
Cable
Cable
Cable
(Optional)
8
Digi-Star Model EZ2000/EZ2000V
3. Mounting and connection
CALIBRATION
LIGHTNING PROTECTION
Additional protection can be achieved with
the proper installation of grounding rods.
Please call (920) 563-9700 and request
Digi-Star Form F3050.
Warning!
This indicator was calibrated at the factory
to weigh accurately with your system.
Additional calibration is not necessary under
normal conditions.
TECHNICAL MANUAL
Technical Manual available upon request.
Please call (920) 563-9700 and request
Digi-Star Manual for New EZ2.
The Short Form Setup & Calibration
procedure allows you to change the
“SETUP” and “CAL” numbers of the
indicator. You may want to perform this
procedure if;
1. The indicator is being connected to
different load cells, or
2. You want to adjust the calibration to
match another scale system.
Before continuing, first write down the
current SETUP and CAL numbers of your EZ
indicator. These numbers are displayed
during the Self Test.
To run the self test:
With the indicator already ON, press the
key to start the Self Test. Press the
key
to "pause" the Self Test while numbers are
again to "resume".
displayed. Press
SETUP # ___________ CAL # ____________
Keep this information for future reference.
!
Do not attempt to calibrate the scale if
the indicator is not reading stable weights.
The calibration procedure will not fix
instability, inconsistencies, or flashing
"RANGE" messages.
9
Digi-Star Model EZ2000/EZ2000V
4. Adjusting indicator to match another scale
4. Adjusting indicator to match another scale
Sometimes two different scales are used to
weigh the same load. When this is done,
the weight measured by each scale may not
be the same. This can be caused by one or
both of the two scales being slightly out of
calibration. This indicator has the ability
to match any other scale, even if that scale
is not calibrated.
Scale Information sheet
To match your EZ scale (Scale A) to
another scale (Scale B) you must determine
the Calibration Multiplier. To do this,
place a load on Scale A (feed wagon, etc...)
and write down the weight displayed.
Repeat several times to determine the
average weight. Next, place the same load
on Scale B and again write down the
weight displayed.
Scale A
Scale B
Original
SETUP #
CAL #
Scale Matching Work Sheet
1 trial
B÷A
Scale Matching Example
B÷A
+
+
=x
x ÷ 3 trials = Cal. Multiplier
____________ = ______________ × ______________
It is important to use an average of several
weights before calibrating the scale.
Scale B
Scale A
3 trial
New EZCAL# = Orig. EZCAL# × Cal.Multiplier
Repeat several times to determine the
average weight. Use the following formula
to determine the Calibration Multiplier for
the EZ’s "CAL" number:
Original
SETUP #
CAL#
2 trial
127060
23980
1 trial
2 trial 3 trial
30,000
30,580 28,000
29,440
29,800 27,500
1.020 + 1.026 + 1.018 = 3.064
3.064 ÷ 3 trials = 1.021
Cal. Multiplier
New EZCAL# = Orig. EZCAL# × Cal.Multiplier
24484
=
23980
×
1.021
You should not modify your "SETUP"
number. Only your "CAL" number.
Follow the instructions: TO CHANGE THE
SETUP/CALIBRATION NUMBERS shown on
the next page.
10
Digi-Star Model EZ2000/EZ2000V
CONNECTING EZ INDICATOR TO
OTHER LOAD CELLS
SETUP
4. Adjusting indicator to match another scale
You will need the number and type of load cells
used in the new scale system. You will also need
the current "SETUP" and "CAL" as described
above. Once you have written down this
information, contact your nearest Scale Service
Center for new "SETUP" and "CAL" numbers.
Follow the instructions “To Change the Setup /
Calibration Numbers” shown below.
Press and hold the
key, then press the
key, to enter Short Form Setup & Calibration.
TO CHANGE THE SETUP &
CALIBRATION NUMBERS
SETUP
127060
127061
The first message displayed is SETUP.
Next, the actual SETUP number is displayed.
! Press the
key for additional help
information during Setup and Calibration.
If the correct SETUP number is displayed, press
the
key to advance to the CAL number.
1. Press the
key to cause the “flashing” digit
to count upward.
2. Press the
flashing.
key to select which digit is
When the correct SETUP number is displayed,
key to advance to the CAL number.
press the
This displays the CAL message,
followed by the CAL number.
CAL
23980
!
The CAL number is not a weight. It is a
reference value the indicator uses to determine the
weight. This number directly affects the accuracy
of the scale system.
Change the CAL number using the same method
described in Steps 1& 2. When the display shows
key. This
the correct number, press the
causes the number to be stored permanently in the
indicator and returns the indicator to the weighing
mode.
11
Digi-Star Model EZ2000/EZ2000V
4. Adjusting indicator to match another scale
TO RETURN TO WEIGH MODE
To exit setup without changing any values, press
and hold the
12
key, then press the
key.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF