LEDstat Dimmer - Wandsworth Electrical

LEDstat Dimmer - Wandsworth Electrical
LEDstat Dimmer
Part No.
329
Primary Range
Dimming
Terminal
Switch input, Live, Load
Input Rated Voltage
230V
Capacity-Minimum Load
5W
Capacity-Maximum Load
100W Trailing Edge
75W Leading Edge
Technical Features:


Designed to control mains dimmable LED lamps or
luminaries.
Input Voltage Tolerance
+5% -10%
Nominal Frequency
50Hz
Standby Power
<0.5w
Operating Temperature
0°C to 70°C
Surge Voltage
1KV
Contact Gap
(ɛ) Electronic Control
Dimensions (mm)
24.5 x 62 x 23
Dims up to 100W of LED lamps in trailing edge mode:

20 x 5W = 100W.

16 x 6W = 96W.

14 x 7W = 98W.

In Leading Edge mode the maximum capacity decreases by 25%.

MAX 75W Leading Edge.

MAX 100W Trailing Edge.

Minimum load down to 5W of load, such as LED, CFL
(compact fluorescent light bulbs) & MV (Mains Voltage) halogen bulbs.

Soft start feature helps extend lamp life.

Manually select dimmer mode (Leading or Trailing
edge).
Standards & Approval
BS EN 60669-2-1

Set minimum light level via the potentiometer.
Minimum Box Depth
35mm

Can be used as part of a multi-way dimming operation
allowing you to switch and dim the lights from multiple
points via Wandsworth’s retractive switches or toggles.

Electronic ON/OFF Auto Detect - Intelligent Dimmer
Module.

Built in thermal overload protection.

Designed to fit in a 35mm BS4662:2006 flush wall box.
Please dispose of electronic equipment responsibly
S13011 12-07-16 ISSUE 3
LEDstat Dimmer
The device is designed for single-phase installation, and must be installed in accordance with applicable
UK and European standards. The device should be connected according to the connection diagram in this
operating manual. Installation, connection, and setup should be carried out by a qualified electrician.
DO NOT disassemble device as it may cause an electric shock and will invalidate the guarantee. Before
installation, ensure the mains power is isolated and connection cables are not live.
For technical support contact us via:
Wandsworth Group Ltd., Ritchie House, Woking Business Park, Albert Drive, Woking, GU21 5JY
Tel 01483 713400
IMPORTANT – PLEASE READ BEFORE INSTALLATION:
Loading:
The LEDstat intelligent dimmer can control up to 100W of the following lighting types:

Incandescent lamps.

Mains halogen.

Mains directly dimmable LED lamps.

Mains directly dimmable CFL lamps.

Dimmable LV electronic transformers.
Installation:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Isolate the mains supply.
Remove the retaining screws and carefully withdraw accessory from wall box to reveal connections at rear.
Check that no mains voltage is present within existing accessory by use of 240 volt test-lamp (if available).
Disconnect all cables noting their respective connections.
Bend back the top and bottom wall box mounting lugs if present.
Ensure the wall box is free from dust and debris.
Connect accessory – see connection Diagram.
Check all connections thoroughly.
Mount accessory, taking care not to trap any cables beneath plate fixing screws. Do not over-tighten the fixing
screws. This may cause damage which could invalidate the warranty.
Switch on mains supply at fuse box and check operation of accessory.
10.
Number of
Nominal plate
dimmer switchsize
es per plate
MAX Loading
per plate
(Trailing Edge)
MAX Loading per
plate
(Leading Edge)
1
86 x 86
100W
75W
2
86 x 86
200W
150W
3
146 x 86
300W
225W
4
146 x 86
400W
300W
S13011 12-07-16 ISSUE 3
LEDstat Dimmer
Initial Start Up Settings:
The following instructions are to enable the first time set up or when the dimmer has been disconnected from the
mains supply (e.g. power cut). We recommend that all lamps in the circuit are of the same type and manufacturer.
Icons indicate when the dimmer needs your input.
Switch on dimmer on by pushing control knob
Allow dimmer to go through auto detect cycle. The light levels will raise and lower AUTOMATICALLY.
When complete the dimmer will either emit one long audible beep or three beeps, depending on load
type.
Dimmer will AUTOMATICALLY power off.
Turn dimmer on by pushing the control knob.
Turn control knob clockwise to raise lighting level.
At full light level dimmer emits beep.
Turn control knob anticlockwise to lower to minimum setting
At lowest level the dimmer will emit an audible beep.
Manually Setting Minimum Light Level:
Should you not be happy with the minimum light level, this can be manually adjusted by the following procedure.
With dimmer in the OFF POSITION press and hold the knob continuously
Dimmer will come on and rise to full light level, then light level will lower and lamps will go out.
Immediately turn the knob clockwise. The lamps will come back on. Adjust to required minimum lighting
level
Once your desired minimum brightness level is achieved. Push the dimmer knob once to store the setting.
Lamps will turn off:
This action EXITS the manual programming mode.
S13011 12-07-16 ISSUE 3
LEDstat Dimmer
LEDSTAT Trouble Shooting
Fault:
1. The lights do not come on:
a.
b.
c.
d.
The dimmer module may be incorrectly wired, require resetting or have been overloaded.
Please check the module is correctly wired and ensure there are no short circuits. The dimmer has short circuit protection and will buzz repeatedly if a short circuit is detected.
Please reset the dimmer module. Disconnect and reconnect the mains supply to the lighting circuit at the consumer unit or fuse box by switching off the appropriate MCB or RCBO for a minimum of 5 seconds.
If the dimmer seems unusually warm it may have been permanently damaged due to overloading. Please
refer to troubleshooting for “The dimmer plate is getting usually hot” before replacing the dimmer.
If none of the above is successful please refer to your Wandsworth supplier or electrical contractor.
2. The lamps flicker.
The dimmer module may be operating in the wrong mode, possibly following a power cut or interruption to the mains
supply.
a.
Please disconnect and reconnect the mains supply to the lighting circuit at the consumer unit or fuse box by
switching off the appropriate MCB for a minimum of 5 seconds. The dimmer should then auto detect the dimming mode next time it is operated.
b.
If this is not successful the dimming mode may need to be set manually. Please refer to “Manually setting
minimum light level” on page 3 in the user guide.
c.
The lamps may not be fully compatible with the dimmer module. Please consult your Wandsworth supplier or
contractor.
3. The dimmer plate is getting unusually hot.
Please note all dimmer modules generate some heat as a small amount of the energy used is dissipated by the module. Up to 40°C (60°C for a plastic plate) above ambient temperature is considered acceptable under EN BS 60669-2
-1.
a.
Ensure the load is below the recommended maximum (100w for trailing edge mode, 75w for leading edge
mode).
b.
Some older leading edge LED lamps and drivers have a very high inrush current which may require the dimmer to dissipate excessive heat. In this case you may need to reduce the number of fittings or change the
lamp and/or Driver
Maintenance:
No decorative, abrasive or domestic cleaning products should come into contact with the accessory (



It should not be used in areas of high humidity (bathrooms etc.), nor within reach of a water source.
This equipment should be connected to a mains supply of the appropriate voltage (indicated on the product).
Care should be taken not to overload the equipment maximum amperage (indicated on the product/packaging).
If you are unsure consult a qualified electrician before installation. No liability can be accepted if the product is installed
or used in any other way than for which it is designed.
Tel: +44(0)1483 713 400
Email: sales@wandsworthgroup.com
S13011 12-07-16 ISSUE 3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising