DriveGuard Sounders
DriveGuard Sounders
CT-A1 Indoor Sounder
The CT-A1 Sounder is an indoor sounder that installs in a single-gang electric box.
Works with DriveGuard Basic and Ultra systems (which use CT-2B and CF-2C control
units respectively, see pages 4 & 5 of Reseller Catalog).
Three Buttons On Plate interact with lights and sensor when used
with the DriveGuard Ultra (CF-2C, see page 5 of Reseller Catalog):
“ON”: Turns lights on, putting them on timer
“RESET”: Turns lights off if they have not timed out
“EXIT”: Turns sensor probe off so car can pass by and not trip the system
(Note: these three buttons are non-functional when used with the DriveGuard
Basic system (which uses CT-2B control unit, see page 4 of Reseller Catalog).
CT-A1 Indoor Sounder
• Full function with added features
• Mounts in single-gang elec. box
• Triple zone allows multiple monitoring • Decorative cover hides screws
• Steacly, fast-pulse, slow-pulse tones • Screw terminal hook up
• Volume control with muting
• Includes set of screws
CT-11 Outdoor Sounder
This is a weather-proof sounder with a piezo-type Mallory Sonalert® for mounting in an outdoor single gang electric box. It It is excellent for areas such as pools,
greenhouses, barns, etc. Length of tone can be adjusted; manual volume control.
CT-11 Outdoor Sounder
• Weather-proof for outdoors
• 90 dB with manual volume control
• Mounts in single-gang elec. box
• Screw terminal hook up
• Pulsating tone
• Includes gasket seal and screws
AA-1 Alarm Alert
This is a universal sounder that has a piezo-type Mallory Sonalert® audible signal device.
It is suitable for any security alarm panel, home automation panel, etc. Requires just
two wires: power positive and power negative. It has volume control; may be muted.
Technical Specifications
CT-A1
CT-11
AA-1
Req. Power
10 - 20 VDC
10 - 20 VDC
10 - 20 VDC
Alarm Current
20 mA max.
25 mA max.
20 mA max.
Dimensions
4½” x 3” x 1”
4½” x 3” x 1”
4½” x 3” x 1”
Weight
1 lb.
1 lb.
1 lb.
Max. Volume
70 dB
90 dB
70 dB
AA-1 Alarm Alert
Preferred Technologies Group
www.cartell.com
800-223-4743
Sounder Installation Instructions
Introduction
Both of the Cartell control units can operate up to twelve
sounders. All our sounders mount in a single-gang electrical box
for flush mounting. All connections are made to a screw terminal
on the back of the sounder’s circuit board. We suggest you use
CAT-5 wire. Solder-tin the ends of the wires before connecting to
the sounder and control unit to avoid corrosion. After you have
run cable from the control unit to the sounder, always connect the
wire to the sounder first and then to the control unit.
Note: After connecting wires to the sounder, and
before connecting the sounder to the control unit,
measure the resistance between the colored wire you
choose to connect to the sonalert and the colored
wire you choose to connect to ground. The resistance
should never be less than 75 ohms total. Resistance
less than 75 ohms shows damage to the wire between
the control unit and sounder (e.g., a staple through the
wire) and will damage the power supply.
CT-A1 Installation Instructions
Refer to the introduction above. First make the connections at the
CT-A1 plate and then to the control unit as follows:
• C onnect one colored wire to the terminal marked “G.” At the
control unit, test the resistance as noted above. Then proceed to
connect this wire to terminal 8 (CT-2B) or to terminal 15 (CF-2C).
• Connect another colored wire to the terminal marked “S”
(for steady tone) or “P1” (for pulsating fast tone) or “P2” (for
pulsating slow tone). At the control unit, test the resistance as
noted above. Then proceed to connect this wire to terminal 9
(CT-2B) or to terminal 14 (CF-2C).
• Connect a third colored wire to the terminal marked “V.” At the
control unit, this wire should be connected to terminal 3 (CT-2B)
or to terminal 6 (CF-2C).
If you are using a CF-2C control unit, three more connections
should be made:
• C onnect a colored wire to the terminal marked “E” on the CT-A1
to terminal 9 on the CF-2C.
• Connect a colored wire to the terminal marked “R” on the CT-A1
to terminal 10 on the CF-2C.
• Connect a colored wire to the terminal marked “M” on the CT-A1
to terminal 8 on the CF-2C.
Note: all three sounders work with
both the CF-2C and CT-2B control units
CT-11 Installation Instructions
Refer to the introduction. First make the connections at the CT-11
plate and then to the control unit as follows:
• C onnect one colored wire to the terminal marked “−”. At the
control unit, test the resistance as noted above. Then proceed to
connect this wire to terminal 8 (CT-2B) or to terminal 15 (CF-2C).
• Connect another colored wire to the terminal marked “+”. At the
control unit, test the resistance as noted above. Then proceed to
connect this wire to terminal 9 (CT-2B) or to terminal 14 (CF-2C).
AA-1 Installation Instructions
The AA-1 works with any security or home automation panel and
with Cartell’s two conrol units (CT-2B and CF-2C).
Refer to the introduction. First make the connections at the
AA-1 plate and then to the security (or other) panel. The AA-1
requires two wires, one for power positive, the other for power
negative. Connect power positive from security panel to the
terminal marked SON on the AA-1. Connect power negative from
the security panel to the terminal marked GND on the AA-1. Test
resistance positive to negative as described in the introduction
and finish by connecting wires to the security panel per the
installation instructions provided with said system.
When used with the Cartell control units, first make the
connections at the AA-1 plate and then to Cartell’s control units as
follows:
• C onnect one colored wire to the terminal marked “GND” on the
AA-1. At the control unit, test the resistance as noted in the
introduction. Then proceed to connect this wire to terminal 8
(CT-2B) or to terminal 15 (CF-2C).
• Connect another colored wire to the terminal marked “SON” on
the AA-1. At the control unit, test the resistance as noted in the
introduction. Then proceed to connect this wire to terminal 9
(CT-2B) or to terminal 14 (CF-2C).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
12 VAC EAR +
+18 PHOTO MAN EXIT RE- NC COM NO SON GND GND RD SH BK
GND 12 VDC VDC CELL ON DEL SET
OUT
CF-2C Terminal
EXTRA
ANNUNCIATOR
RELAY
+
CONTACTS
Preferred Technologies Group
www.cartell.com
1 2 3 4 5 6 7 8 9 10 11 12
+
16 TS NC C NO
8-31 VAC VDC
10-41 VDC OUT
CT-2B Terminal
800-223-4743
+ RD SH BK
PROBE
(or other sensing
device w/ resistor,
see CT-2B manual)
Was this manual useful for you? yes no